메뉴 건너뛰기




Volumn 219, Issue 6, 2005, Pages 437-448

A 12-station anatomic hip joint simulator

Author keywords

CoCr; Hip joint simulator; Large diameter metal on metal articulation; Ultra high molecular weight polyethylene; Validation

Indexed keywords

ABSORPTION SPECTROSCOPY; ATOMIC SPECTROSCOPY; BEARINGS (MACHINE PARTS); BURNISHING; COBALT ALLOYS; FILMS; HEATING; LUBRICANTS; LUBRICATION; TRIBOLOGY; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS; HIP PROSTHESES; JOINT PROSTHESES; METALS; SIMULATORS;

EID: 27744560273     PISSN: 09544119     EISSN: 09544119     Source Type: Journal    
DOI: 10.1243/095441105X34419     Document Type: Article
Times cited : (66)

References (40)
  • 1
    • 0036205442 scopus 로고    scopus 로고
    • Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators
    • Saikko, V. and Calonius, O. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. J. Biomechanics, 2002, 35, 455-464.
    • (2002) J. Biomechanics , vol.35 , pp. 455-464
    • Saikko, V.1    Calonius, O.2
  • 2
    • 0036844166 scopus 로고    scopus 로고
    • Slide track analysis of eight contemporary hip simulator designs
    • Calonius, O. and Saikko, V. Slide track analysis of eight contemporary hip simulator designs. J. Biomechanics, 2002, 35, 1439-1450.
    • (2002) J. Biomechanics , vol.35 , pp. 1439-1450
    • Calonius, O.1    Saikko, V.2
  • 3
    • 0141680572 scopus 로고    scopus 로고
    • Force track analysis of contemporary hip simulators
    • Calonius, O. and Saikko, V. Force track analysis of contemporary hip simulators. J. Biomechanics, 2003, 36, 1719-1726.
    • (2003) J. Biomechanics , vol.36 , pp. 1719-1726
    • Calonius, O.1    Saikko, V.2
  • 4
    • 0242659323 scopus 로고    scopus 로고
    • An improved method of computing the wear factor for total hip prostheses involving the variation of relative motion and contact pressure with location on the bearing surface
    • Saikko, V. and Calonius, O. An improved method of computing the wear factor for total hip prostheses involving the variation of relative motion and contact pressure with location on the bearing surface. J. Biomechanics, 2003, 36, 1819-1827.
    • (2003) J. Biomechanics , vol.36 , pp. 1819-1827
    • Saikko, V.1    Calonius, O.2
  • 7
    • 0030339155 scopus 로고    scopus 로고
    • A three-axis hip joint simulator for wear and friction studies on total hip prostheses
    • Saikko, V. A three-axis hip joint simulator for wear and friction studies on total hip prostheses. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1996, 210, 175-185.
    • (1996) Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine , vol.210 , pp. 175-185
    • Saikko, V.1
  • 9
    • 0242709585 scopus 로고    scopus 로고
    • Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator
    • Saikko, V., Calonius, O., and Keränen, J. Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator. J. Biomed. Mater. Res. (Appl. Biomater.), 2003, 65B, 186-192.
    • (2003) J. Biomed. Mater. Res. (Appl. Biomater.) , vol.65 B , pp. 186-192
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 10
    • 0021938897 scopus 로고
    • Degradation and wear of ultra-high-molecular-weight polyethylene
    • (Eds A. C. Fraker and C. D. Griffin), ASTM STP 859, (American Society for Testing and Materials, Philadelphia, Pennsylvania)
    • McKellop, H. A. and Clarke, I. C. Degradation and wear of ultra-high-molecular-weight polyethylene. In Corrosion and Degradation of Implant Materials: Second Symposium (Eds A. C. Fraker and C. D. Griffin), ASTM STP 859, 1985, pp. 351-368 (American Society for Testing and Materials, Philadelphia, Pennsylvania).
    • (1985) Corrosion and Degradation of Implant Materials: Second Symposium , pp. 351-368
    • McKellop, H.A.1    Clarke, I.C.2
  • 11
    • 0014574695 scopus 로고
    • Measurement of hip-joint motion during walking - Evaluation of an electrogoniometric method
    • Johnston, R. C. and Smidt, G. L. Measurement of hip-joint motion during walking - evaluation of an electrogoniometric method. J. Bone Jt Surg., 1969, 51A, 1083-1094.
    • (1969) J. Bone Jt. Surg. , vol.51 A , pp. 1083-1094
    • Johnston, R.C.1    Smidt, G.L.2
  • 12
    • 0022516387 scopus 로고
    • Three-dimensional electrogoniometric gait recording
    • Isacson, J., Gransberg, L., and Knutsson, E. Three-dimensional electrogoniometric gait recording. J. Biomechanics, 1986, 19, 627-635.
    • (1986) J. Biomechanics , vol.19 , pp. 627-635
    • Isacson, J.1    Gransberg, L.2    Knutsson, E.3
  • 13
    • 0025424645 scopus 로고
    • Measurement of lower extremity kinematics during level walking
    • Kadaba, M. P., Ramakrishnan, H. K., and Wootten, M. E. Measurement of lower extremity kinematics during level walking. J. Orthop. Res., 1990, 8, 383-392.
    • (1990) J. Orthop. Res. , vol.8 , pp. 383-392
    • Kadaba, M.P.1    Ramakrishnan, H.K.2    Wootten, M.E.3
  • 16
    • 0042126909 scopus 로고    scopus 로고
    • The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls
    • Liao, Y.-S., McKellop, H., Lu, Z., Campbell, P, and Benya, P. The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls. Biomaterials, 2003, 24, 3047-3059.
    • (2003) Biomaterials , vol.24 , pp. 3047-3059
    • Liao, Y.-S.1    McKellop, H.2    Lu, Z.3    Campbell, P.4    Benya, P.5
  • 17
    • 0035892402 scopus 로고    scopus 로고
    • Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multidirectional motion pin-on-disk device
    • Saikko, V., Calonius, O., and Keränen, J. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multidirectional motion pin-on-disk device. J. Biomed. Mater Res., 2001, 57, 506-512.
    • (2001) J. Biomed. Mater. Res. , vol.57 , pp. 506-512
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 18
    • 0031725906 scopus 로고    scopus 로고
    • Metal release from total hip articulations in vitro: Substantial from CoCr/CrCr, negligible from CoCr/PE and alumina/PE
    • Saikko, V., Nevalainen, J., Revitzer, H., and Ylinen, P. Metal release from total hip articulations in vitro: substantial from CoCr/CrCr, negligible from CoCr/PE and alumina/PE. Acta Orthop. Scand., 1998, 69, 449-454.
    • (1998) Acta Orthop. Scand. , vol.69 , pp. 449-454
    • Saikko, V.1    Nevalainen, J.2    Revitzer, H.3    Ylinen, P.4
  • 19
    • 0036274703 scopus 로고    scopus 로고
    • Analysis of polyethylene particles produced in different wear conditions in vitro
    • Calonius, O. and Saikko V. Analysis of polyethylene particles produced in different wear conditions in vitro. Clin. Orthop., 2002, 399, 219-230.
    • (2002) Clin. Orthop. , vol.399 , pp. 219-230
    • Calonius, O.1    Saikko, V.2
  • 24
    • 0022108301 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. II: A microscopical study of the surfaces of Charnley polyethylene acetabular sockets
    • Atkinson, J. R., Dowson, D., Isaac, G. H., and Wroblewski, B. M. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. II: a microscopical study of the surfaces of Charnley polyethylene acetabular sockets. Wear, 1985, 104, 217-224.
    • (1985) Wear , vol.104 , pp. 217-224
    • Atkinson, J.R.1    Dowson, D.2    Isaac, G.H.3    Wroblewski, B.M.4
  • 25
    • 0024040573 scopus 로고
    • Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints
    • Dowson, D. and Jobbins, B. Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints. Engng Medicine, 1988, 17(3), 111-117.
    • (1988) Engng. Medicine , vol.17 , Issue.3 , pp. 111-117
    • Dowson, D.1    Jobbins, B.2
  • 26
    • 2442447086 scopus 로고    scopus 로고
    • Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis
    • Saikko, V., Calonius, O., and Keränen, J. Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis. J. Biomed. Mater Res. (Appl. Biomater.), 2004, 69B, 141-148.
    • (2004) J. Biomed. Mater Res. (Appl. Biomater.) , vol.69 B , pp. 141-148
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 28
    • 0042564752 scopus 로고    scopus 로고
    • Tribochemical reaction on metal-on-metal hip joint bearings: A comparison between in-vitro and in-vivo results
    • Wimmer, M. A., Sprecher, C., Hauert, R., Täger, G., and Fischer, A. Tribochemical reaction on metal-on-metal hip joint bearings: a comparison between in-vitro and in-vivo results. Wear, 2003, 255, 1007-1014.
    • (2003) Wear , vol.255 , pp. 1007-1014
    • Wimmer, M.A.1    Sprecher, C.2    Hauert, R.3    Täger, G.4    Fischer, A.5
  • 30
    • 9444289847 scopus 로고    scopus 로고
    • Tissue reaction to metal on metal total hip prostheses
    • Doorn, P. F., Mirra, J. H., Campbell, P. A., and Amstutz, H. C. Tissue reaction to metal on metal total hip prostheses. Clin. Orthop., 1996, 329S, 187-205.
    • (1996) Clin. Orthop. , vol.329 S , pp. 187-205
    • Doorn, P.F.1    Mirra, J.H.2    Campbell, P.A.3    Amstutz, H.C.4
  • 31
    • 0035045395 scopus 로고    scopus 로고
    • Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
    • Firkins, P. J., Tipper, J. L., Saadatzadeh, M. R., Ingham, E., Stone, M. H., Farrar, R., and Fisher J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed. Mater. Engng, 2001, 11, 143-157.
    • (2001) Biomed. Mater. Engng. , vol.11 , pp. 143-157
    • Firkins, P.J.1    Tipper, J.L.2    Saadatzadeh, M.R.3    Ingham, E.4    Stone, M.H.5    Farrar, R.6    Fisher, J.7
  • 33
    • 0037224605 scopus 로고    scopus 로고
    • Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
    • Lhotka, C., Szekeres, T., Steffan, I., Zhuber, K., and Zweymüller, K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J. Orthop. Res., 2003, 21, 189-195.
    • (2003) J. Orthop. Res. , vol.21 , pp. 189-195
    • Lhotka, C.1    Szekeres, T.2    Steffan, I.3    Zhuber, K.4    Zweymüller, K.5
  • 37
    • 0042230975 scopus 로고    scopus 로고
    • Effect of lubricant protein concentration on the wear of ultra-high molecular weight polyethylene sliding against a CoCr counterface
    • Saikko, V. Effect of lubricant protein concentration on the wear of ultra-high molecular weight polyethylene sliding against a CoCr counterface. J. Tribology 2003, 125, 638-642.
    • (2003) J. Tribology , vol.125 , pp. 638-642
    • Saikko, V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.