1
-
-
0036205442
-
Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators
-
Saikko, V. and Calonius, O. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. J. Biomechanics, 2002, 35, 455-464.
-
(2002)
J. Biomechanics
, vol.35
, pp. 455-464
-
-
Saikko, V.1
Calonius, O.2
-
2
-
-
0036844166
-
Slide track analysis of eight contemporary hip simulator designs
-
Calonius, O. and Saikko, V. Slide track analysis of eight contemporary hip simulator designs. J. Biomechanics, 2002, 35, 1439-1450.
-
(2002)
J. Biomechanics
, vol.35
, pp. 1439-1450
-
-
Calonius, O.1
Saikko, V.2
-
3
-
-
0141680572
-
Force track analysis of contemporary hip simulators
-
Calonius, O. and Saikko, V. Force track analysis of contemporary hip simulators. J. Biomechanics, 2003, 36, 1719-1726.
-
(2003)
J. Biomechanics
, vol.36
, pp. 1719-1726
-
-
Calonius, O.1
Saikko, V.2
-
4
-
-
0242659323
-
An improved method of computing the wear factor for total hip prostheses involving the variation of relative motion and contact pressure with location on the bearing surface
-
Saikko, V. and Calonius, O. An improved method of computing the wear factor for total hip prostheses involving the variation of relative motion and contact pressure with location on the bearing surface. J. Biomechanics, 2003, 36, 1819-1827.
-
(2003)
J. Biomechanics
, vol.36
, pp. 1819-1827
-
-
Saikko, V.1
Calonius, O.2
-
6
-
-
0027015657
-
A five-station hip joint simulator for wear rate studies
-
Saikko, V., Paavolainen, P, Kleimola, M., and Slätis, P. A five-station hip joint simulator for wear rate studies. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1992, 206, 195-200.
-
(1992)
Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine
, vol.206
, pp. 195-200
-
-
Saikko, V.1
Paavolainen, P.2
Kleimola, M.3
Slätis, P.4
-
7
-
-
0030339155
-
A three-axis hip joint simulator for wear and friction studies on total hip prostheses
-
Saikko, V. A three-axis hip joint simulator for wear and friction studies on total hip prostheses. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1996, 210, 175-185.
-
(1996)
Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine
, vol.210
, pp. 175-185
-
-
Saikko, V.1
-
8
-
-
0032616832
-
Type of motion and lubricant in wear simulation of polyethylene acetabular cup
-
Saikko, V. and Ahlroos, T. Type of motion and lubricant in wear simulation of polyethylene acetabular cup. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1999, 213, 301-310.
-
(1999)
Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine
, vol.213
, pp. 301-310
-
-
Saikko, V.1
Ahlroos, T.2
-
9
-
-
0242709585
-
Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator
-
Saikko, V., Calonius, O., and Keränen, J. Effect of extent of motion and type of load on the wear of polyethylene in a biaxial hip simulator. J. Biomed. Mater. Res. (Appl. Biomater.), 2003, 65B, 186-192.
-
(2003)
J. Biomed. Mater. Res. (Appl. Biomater.)
, vol.65 B
, pp. 186-192
-
-
Saikko, V.1
Calonius, O.2
Keränen, J.3
-
10
-
-
0021938897
-
Degradation and wear of ultra-high-molecular-weight polyethylene
-
(Eds A. C. Fraker and C. D. Griffin), ASTM STP 859, (American Society for Testing and Materials, Philadelphia, Pennsylvania)
-
McKellop, H. A. and Clarke, I. C. Degradation and wear of ultra-high-molecular-weight polyethylene. In Corrosion and Degradation of Implant Materials: Second Symposium (Eds A. C. Fraker and C. D. Griffin), ASTM STP 859, 1985, pp. 351-368 (American Society for Testing and Materials, Philadelphia, Pennsylvania).
-
(1985)
Corrosion and Degradation of Implant Materials: Second Symposium
, pp. 351-368
-
-
McKellop, H.A.1
Clarke, I.C.2
-
11
-
-
0014574695
-
Measurement of hip-joint motion during walking - Evaluation of an electrogoniometric method
-
Johnston, R. C. and Smidt, G. L. Measurement of hip-joint motion during walking - evaluation of an electrogoniometric method. J. Bone Jt Surg., 1969, 51A, 1083-1094.
-
(1969)
J. Bone Jt. Surg.
, vol.51 A
, pp. 1083-1094
-
-
Johnston, R.C.1
Smidt, G.L.2
-
12
-
-
0022516387
-
Three-dimensional electrogoniometric gait recording
-
Isacson, J., Gransberg, L., and Knutsson, E. Three-dimensional electrogoniometric gait recording. J. Biomechanics, 1986, 19, 627-635.
-
(1986)
J. Biomechanics
, vol.19
, pp. 627-635
-
-
Isacson, J.1
Gransberg, L.2
Knutsson, E.3
-
13
-
-
0025424645
-
Measurement of lower extremity kinematics during level walking
-
Kadaba, M. P., Ramakrishnan, H. K., and Wootten, M. E. Measurement of lower extremity kinematics during level walking. J. Orthop. Res., 1990, 8, 383-392.
-
(1990)
J. Orthop. Res.
, vol.8
, pp. 383-392
-
-
Kadaba, M.P.1
Ramakrishnan, H.K.2
Wootten, M.E.3
-
14
-
-
0034984126
-
Hip contact forces and gait patterns from routine activities
-
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J., and Duda, G. N. Hip contact forces and gait patterns from routine activities. J. Biomechanics, 2001, 34, 859-871.
-
(2001)
J. Biomechanics
, vol.34
, pp. 859-871
-
-
Bergmann, G.1
Deuretzbacher, G.2
Heller, M.3
Graichen, F.4
Rohlmann, A.5
Strauss, J.6
Duda, G.N.7
-
15
-
-
0037854675
-
Quantitative analysis of serum degradation and its effect on the outcome of hip joint simulator wear testing on UHMWPE
-
Anaheim, California, USA, 1-4 February
-
Wang, A., Polineni, V. K., Essner, A., Stark, C., and Dumbleton, J. H. Quantitative analysis of serum degradation and its effect on the outcome of hip joint simulator wear testing on UHMWPE. In Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society, Anaheim, California, USA, 1-4 February 1999, p. 73.
-
(1999)
Proceedings of the 45th Annual Meeting of the Orthopaedic Research Society
, pp. 73
-
-
Wang, A.1
Polineni, V.K.2
Essner, A.3
Stark, C.4
Dumbleton, J.H.5
-
16
-
-
0042126909
-
The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls
-
Liao, Y.-S., McKellop, H., Lu, Z., Campbell, P, and Benya, P. The effect of frictional heating and forced cooling on the serum lubricant and wear of UHMW polyethylene cups against cobalt-chromium and zirconia balls. Biomaterials, 2003, 24, 3047-3059.
-
(2003)
Biomaterials
, vol.24
, pp. 3047-3059
-
-
Liao, Y.-S.1
McKellop, H.2
Lu, Z.3
Campbell, P.4
Benya, P.5
-
17
-
-
0035892402
-
Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multidirectional motion pin-on-disk device
-
Saikko, V., Calonius, O., and Keränen, J. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multidirectional motion pin-on-disk device. J. Biomed. Mater Res., 2001, 57, 506-512.
-
(2001)
J. Biomed. Mater. Res.
, vol.57
, pp. 506-512
-
-
Saikko, V.1
Calonius, O.2
Keränen, J.3
-
18
-
-
0031725906
-
Metal release from total hip articulations in vitro: Substantial from CoCr/CrCr, negligible from CoCr/PE and alumina/PE
-
Saikko, V., Nevalainen, J., Revitzer, H., and Ylinen, P. Metal release from total hip articulations in vitro: substantial from CoCr/CrCr, negligible from CoCr/PE and alumina/PE. Acta Orthop. Scand., 1998, 69, 449-454.
-
(1998)
Acta Orthop. Scand.
, vol.69
, pp. 449-454
-
-
Saikko, V.1
Nevalainen, J.2
Revitzer, H.3
Ylinen, P.4
-
19
-
-
0036274703
-
Analysis of polyethylene particles produced in different wear conditions in vitro
-
Calonius, O. and Saikko V. Analysis of polyethylene particles produced in different wear conditions in vitro. Clin. Orthop., 2002, 399, 219-230.
-
(2002)
Clin. Orthop.
, vol.399
, pp. 219-230
-
-
Calonius, O.1
Saikko, V.2
-
20
-
-
0028836831
-
The origin of submicron polyethylene wear debris in total hip arthroplasty
-
McKellop, H. A., Campbell, P., Park, S.-H., Schmalzried, T. P., Grigoris, P., Amstutz, H. C., and Sarmiento, A. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin. Orthop., 1995, 311, 3-20.
-
(1995)
Clin. Orthop.
, vol.311
, pp. 3-20
-
-
McKellop, H.A.1
Campbell, P.2
Park, S.-H.3
Schmalzried, T.P.4
Grigoris, P.5
Amstutz, H.C.6
Sarmiento, A.7
-
21
-
-
0036381564
-
Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties
-
Mabrey, J. D., Afsar-Keshmiri, A., Engh, G. A., Sychterz, C. J., Wirth, M. A., Rockwood, C. A., and Agrawal, C. M. Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties. J. Biomed. Mater. Res. (Appl. Biomater.), 2002, 63, 475-483.
-
(2002)
J. Biomed. Mater. Res. (Appl. Biomater.)
, vol.63
, pp. 475-483
-
-
Mabrey, J.D.1
Afsar-Keshmiri, A.2
Engh, G.A.3
Sychterz, C.J.4
Wirth, M.A.5
Rockwood, C.A.6
Agrawal, C.M.7
-
22
-
-
0030331546
-
Wear in retrieved Charnley acetabular sockets
-
Hall, R. M., Unsworth, A., Siney, P., and Wroblewski, B. M. Wear in retrieved Charnley acetabular sockets. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1996, 210, 197-207.
-
(1996)
Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine
, vol.210
, pp. 197-207
-
-
Hall, R.M.1
Unsworth, A.2
Siney, P.3
Wroblewski, B.M.4
-
23
-
-
0032924283
-
Analysis of prosthetic femoral heads retrieved at autopsy
-
Sychterz, C. J., Engh, C. A. Jr., Swope, S. W., McNulty, D. E., and Engh, C. A. Analysis of prosthetic femoral heads retrieved at autopsy. Clin. Orthop., 1999, 358, 223-234.
-
(1999)
Clin. Orthop.
, vol.358
, pp. 223-234
-
-
Sychterz, C.J.1
Engh Jr., C.A.2
Swope, S.W.3
McNulty, D.E.4
Engh, C.A.5
-
24
-
-
0022108301
-
Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. II: A microscopical study of the surfaces of Charnley polyethylene acetabular sockets
-
Atkinson, J. R., Dowson, D., Isaac, G. H., and Wroblewski, B. M. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. II: a microscopical study of the surfaces of Charnley polyethylene acetabular sockets. Wear, 1985, 104, 217-224.
-
(1985)
Wear
, vol.104
, pp. 217-224
-
-
Atkinson, J.R.1
Dowson, D.2
Isaac, G.H.3
Wroblewski, B.M.4
-
25
-
-
0024040573
-
Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints
-
Dowson, D. and Jobbins, B. Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints. Engng Medicine, 1988, 17(3), 111-117.
-
(1988)
Engng. Medicine
, vol.17
, Issue.3
, pp. 111-117
-
-
Dowson, D.1
Jobbins, B.2
-
26
-
-
2442447086
-
Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis
-
Saikko, V., Calonius, O., and Keränen, J. Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis. J. Biomed. Mater Res. (Appl. Biomater.), 2004, 69B, 141-148.
-
(2004)
J. Biomed. Mater Res. (Appl. Biomater.)
, vol.69 B
, pp. 141-148
-
-
Saikko, V.1
Calonius, O.2
Keränen, J.3
-
27
-
-
0029831455
-
In vivo wear of 3 types of metal on metal hip prostheses during 2 decades of use
-
McKellop, H. A., Park, S.-H., Chiesa, R., Doorn, P., Lu, B., Normand, P., Grigoris, P., and Amstutz, H. In vivo wear of 3 types of metal on metal hip prostheses during 2 decades of use. Clin. Orthop., 1996, 329S,128-140.
-
(1996)
Clin. Orthop.
, vol.329 S
, pp. 128-140
-
-
McKellop, H.A.1
Park, S.-H.2
Chiesa, R.3
Doorn, P.4
Lu, B.5
Normand, P.6
Grigoris, P.7
Amstutz, H.8
-
28
-
-
0042564752
-
Tribochemical reaction on metal-on-metal hip joint bearings: A comparison between in-vitro and in-vivo results
-
Wimmer, M. A., Sprecher, C., Hauert, R., Täger, G., and Fischer, A. Tribochemical reaction on metal-on-metal hip joint bearings: a comparison between in-vitro and in-vivo results. Wear, 2003, 255, 1007-1014.
-
(2003)
Wear
, vol.255
, pp. 1007-1014
-
-
Wimmer, M.A.1
Sprecher, C.2
Hauert, R.3
Täger, G.4
Fischer, A.5
-
29
-
-
0035229408
-
The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements
-
Smith, S. L., Dowson, D., and Goldsmith, A. A. J. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215, 161-170.
-
(2001)
Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine
, vol.215
, pp. 161-170
-
-
Smith, S.L.1
Dowson, D.2
Goldsmith, A.A.J.3
-
30
-
-
9444289847
-
Tissue reaction to metal on metal total hip prostheses
-
Doorn, P. F., Mirra, J. H., Campbell, P. A., and Amstutz, H. C. Tissue reaction to metal on metal total hip prostheses. Clin. Orthop., 1996, 329S, 187-205.
-
(1996)
Clin. Orthop.
, vol.329 S
, pp. 187-205
-
-
Doorn, P.F.1
Mirra, J.H.2
Campbell, P.A.3
Amstutz, H.C.4
-
31
-
-
0035045395
-
Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator
-
Firkins, P. J., Tipper, J. L., Saadatzadeh, M. R., Ingham, E., Stone, M. H., Farrar, R., and Fisher J. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Biomed. Mater. Engng, 2001, 11, 143-157.
-
(2001)
Biomed. Mater. Engng.
, vol.11
, pp. 143-157
-
-
Firkins, P.J.1
Tipper, J.L.2
Saadatzadeh, M.R.3
Ingham, E.4
Stone, M.H.5
Farrar, R.6
Fisher, J.7
-
32
-
-
0242490794
-
Serum cobalt levels after metal-on-metal total hip arthroplasty
-
Brodner, W., Bitzan, P., Meisinger, V., Kaider, A., Gottsauner-Wolf, F., and Kotz, R. Serum cobalt levels after metal-on-metal total hip arthroplasty. J. Bone Jt Surg., 2003, 85A, 2168-2173.
-
(2003)
J. Bone Jt. Surg.
, vol.85 A
, pp. 2168-2173
-
-
Brodner, W.1
Bitzan, P.2
Meisinger, V.3
Kaider, A.4
Gottsauner-Wolf, F.5
Kotz, R.6
-
33
-
-
0037224605
-
Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
-
Lhotka, C., Szekeres, T., Steffan, I., Zhuber, K., and Zweymüller, K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J. Orthop. Res., 2003, 21, 189-195.
-
(2003)
J. Orthop. Res.
, vol.21
, pp. 189-195
-
-
Lhotka, C.1
Szekeres, T.2
Steffan, I.3
Zhuber, K.4
Zweymüller, K.5
-
34
-
-
27744560704
-
In-vitro tribology of large metal-on-metal implants - Influence of the clearance
-
San Francisco, California, USA, 7-10 March
-
Rieker, C. B., Schön, R., Liebentritt, G., Gnepf, P. Roberts, P., and Grigoris, P. In-vitro tribology of large metal-on-metal implants - influence of the clearance. In Proceedings of the 50th Annual Meeting of the Orthopaedic Research Society, San Francisco, California, USA, 7-10 March 2004, p. 123.
-
(2004)
Proceedings of the 50th Annual Meeting of the Orthopaedic Research Society
, pp. 123
-
-
Rieker, C.B.1
Schön, R.2
Liebentritt, G.3
Gnepf, P.4
Roberts, P.5
Grigoris, P.6
-
35
-
-
0346725977
-
Wear evaluation of cobalt-chromium alloy for use in a metal-on-metal hip prosthesis
-
St John, K. R., Zardiackas, L. D., and Poggie, R. A. Wear evaluation of cobalt-chromium alloy for use in a metal-on-metal hip prosthesis. J. Biomed. Mater. Res. (Appl. Biomater.), 2004, 68B, 1-14.
-
(2004)
J. Biomed. Mater. Res. (Appl. Biomater.)
, vol.68 B
, pp. 1-14
-
-
St. John, K.R.1
Zardiackas, L.D.2
Poggie, R.A.3
-
37
-
-
0042230975
-
Effect of lubricant protein concentration on the wear of ultra-high molecular weight polyethylene sliding against a CoCr counterface
-
Saikko, V. Effect of lubricant protein concentration on the wear of ultra-high molecular weight polyethylene sliding against a CoCr counterface. J. Tribology 2003, 125, 638-642.
-
(2003)
J. Tribology
, vol.125
, pp. 638-642
-
-
Saikko, V.1
-
38
-
-
0030331545
-
The importance of multidirectional motion on the wear of polyethylene
-
Bragdon, C. R., O'Connor, D. O.; Lowenstein, J. D., Jasty, M., and Syniuta, W. D. The importance of multidirectional motion on the wear of polyethylene. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 1996, 210, 157-165.
-
(1996)
Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine
, vol.210
, pp. 157-165
-
-
Bragdon, C.R.1
O'Connor, D.O.2
Lowenstein, J.D.3
Jasty, M.4
Syniuta, W.D.5
-
39
-
-
0035232592
-
Hip simulator wear testing according to the newly introduced standard ISO 14242
-
Kaddick, C. and Wimmer, M. A. Hip simulator wear testing according to the newly introduced standard ISO 14242. Proc. Instn Mech. Engrs, Part H: J. Engineering in Medicine, 2001, 215, 429-442.
-
(2001)
Proc. Instn. Mech. Engrs., Part H: J. Engineering in Medicine
, vol.215
, pp. 429-442
-
-
Kaddick, C.1
Wimmer, M.A.2
|