메뉴 건너뛰기




Volumn 65, Issue 1, 2003, Pages 186-192

Effect of Extent of Motion and Type of Load on the Wear of Polyethylene in a Biaxial Hip Simulator

Author keywords

Dynamic load; Extent of motion; Hip simulator; Polyethylene wear; Total hip prosthesis

Indexed keywords

BODY FLUIDS; LOADS (FORCES); TISSUE; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 0242709585     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.b.10556     Document Type: Article
Times cited : (16)

References (20)
  • 1
    • 0021938897 scopus 로고
    • Degradation and wear of ultra-high-molecular-weight polyethylene
    • Fraker AC, Griffin CD, editors. Philadelphia: American Society for Testing and Materials
    • McKellop HA, Clarke IC. Degradation and wear of ultra-high-molecular-weight polyethylene. In: Fraker AC, Griffin CD, editors. Corrosion and degradation of implant materials: Second symposium, ASTM STP 859. Philadelphia: American Society for Testing and Materials; 1985. pp 351-368.
    • (1985) Corrosion and Degradation of Implant Materials: Second Symposium, ASTM STP 859 , pp. 351-368
    • McKellop, H.A.1    Clarke, I.C.2
  • 2
    • 0014574695 scopus 로고
    • Measurement of hip-joint motion during walking-evaluation of an electrogoniometric method
    • Johnston RC, Smidt GL. Measurement of hip-joint motion during walking-evaluation of an electrogoniometric method. J Bone Joint Surg 1969;51A:1083-1094.
    • (1969) J Bone Joint Surg , vol.51 A , pp. 1083-1094
    • Johnston, R.C.1    Smidt, G.L.2
  • 3
    • 0036844166 scopus 로고    scopus 로고
    • Slide track analysis of eight contemporary hip simulator designs
    • Calonius O, Saikko V. Slide track analysis of eight contemporary hip simulator designs. J Biomech 2002;35:1439-1450.
    • (2002) J Biomech , vol.35 , pp. 1439-1450
    • Calonius, O.1    Saikko, V.2
  • 4
    • 0036205442 scopus 로고    scopus 로고
    • Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators
    • Saikko V, Calonius O. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. J Biomech 2002;35:455-464.
    • (2002) J Biomech , vol.35 , pp. 455-464
    • Saikko, V.1    Calonius, O.2
  • 6
    • 0032616832 scopus 로고    scopus 로고
    • Type of motion and lubricant in wear simulation of polyethylene acetabular cup
    • Saikko V, Ahlroos T. Type of motion and lubricant in wear simulation of polyethylene acetabular cup. Proc Inst Mech Eng Pt H 1999;213:301-310.
    • (1999) Proc Inst Mech Eng Pt H , vol.213 , pp. 301-310
    • Saikko, V.1    Ahlroos, T.2
  • 7
    • 0035876256 scopus 로고    scopus 로고
    • Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon
    • Saikko V, Ahlroos T, Calonius O, Keränen J. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon. Biomaterials 2001;22:1507-1514.
    • (2001) Biomaterials , vol.22 , pp. 1507-1514
    • Saikko, V.1    Ahlroos, T.2    Calonius, O.3    Keränen, J.4
  • 9
    • 0030175572 scopus 로고    scopus 로고
    • Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty
    • Hirakawa K, Bauer TW, Stulberg BN, Wilde AH. Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty. J Biomed Mater Res 1996;31:257-263.
    • (1996) J Biomed Mater Res , vol.31 , pp. 257-263
    • Hirakawa, K.1    Bauer, T.W.2    Stulberg, B.N.3    Wilde, A.H.4
  • 12
    • 0035892402 scopus 로고    scopus 로고
    • Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device
    • Saikko V, Calonius O, Keränen J. Effect of counterface roughness on the wear of conventional and crosslinked ultrahigh molecular weight polyethylene studied with a multi-directional motion pin-on-disk device. J Biomed Mater Res 2001;57:506-512.
    • (2001) J Biomed Mater Res , vol.57 , pp. 506-512
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 13
    • 0036435261 scopus 로고    scopus 로고
    • Wear of conventional and crosslinked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator
    • Saikko V, Calonius O, Keränen J. Wear of conventional and crosslinked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator. J Biomed Mater Res Appl Biomater 2002;63:848-853.
    • (2002) J Biomed Mater Res Appl Biomater , vol.63 , pp. 848-853
    • Saikko, V.1    Calonius, O.2    Keränen, J.3
  • 14
    • 0010861724 scopus 로고    scopus 로고
    • Doctoral dissertation, Acta Polytechnica Scandinavica, Me 153, the Finnish Academies of Technology, Helsinki
    • Ahlroos T. Effect of lubricant on the wear of prosthetic joint materials. Doctoral dissertation, Acta Polytechnica Scandinavica, Me 153, the Finnish Academies of Technology, Helsinki, 2001.
    • (2001) Effect of Lubricant on the Wear of Prosthetic Joint Materials
    • Ahlroos, T.1
  • 16
    • 0026998133 scopus 로고
    • A simulator study of friction in total replacement hip joints
    • Saikko V. A simulator study of friction in total replacement hip joints. Proc Inst Mech Eng Pt H 1992;206:201-211.
    • (1992) Proc Inst Mech Eng Pt H , vol.206 , pp. 201-211
    • Saikko, V.1
  • 17
    • 0022108301 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. II: A microscopical study of the surfaces of Charnley polyethylene acetabular sockets
    • Atkinson JR, Dowson D, Isaac GH, Wroblewski BM. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. II: A microscopical study of the surfaces of Charnley polyethylene acetabular sockets. Wear 1985;104:217-224.
    • (1985) Wear , vol.104 , pp. 217-224
    • Atkinson, J.R.1    Dowson, D.2    Isaac, G.H.3    Wroblewski, B.M.4
  • 18
    • 0022108298 scopus 로고
    • Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. III: The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors
    • Atkinson JR, Dowson D, Isaac GH, Wroblewski BM. Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints. III: The measurement of internal volume changes in explanted Charnley sockets after 2-16 years in vivo and the determination of wear factors. Wear 1985;104:225-244.
    • (1985) Wear , vol.104 , pp. 225-244
    • Atkinson, J.R.1    Dowson, D.2    Isaac, G.H.3    Wroblewski, B.M.4
  • 20
    • 0016881356 scopus 로고
    • Force actions transmitted by joints in the human body
    • Paul JP. Force actions transmitted by joints in the human body. Proc R Soc London Ser B 1976;192:163-172.
    • (1976) Proc R Soc London Ser B , vol.192 , pp. 163-172
    • Paul, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.