메뉴 건너뛰기




Volumn 35, Issue 11, 2002, Pages 1439-1450

Slide track analysis of eight contemporary hip simulator designs

Author keywords

Euler angle; Hip simulator; Multidirectional motion; Slide track; Wear

Indexed keywords

CALCULATIONS; COMPUTER SIMULATION; HIP PROSTHESES; WAVEFORM ANALYSIS;

EID: 0036844166     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0021-9290(02)00171-9     Document Type: Article
Times cited : (62)

References (18)
  • 1
    • 0033252596 scopus 로고    scopus 로고
    • A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
    • Barbour P.S., Stone M.H., Fisher J. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates. Journal of Engineering in Medicine. 213:1999;455-467.
    • (1999) Journal of Engineering in Medicine , vol.213 , pp. 455-467
    • Barbour, P.S.1    Stone, M.H.2    Fisher, J.3
  • 2
    • 0033755919 scopus 로고    scopus 로고
    • Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation
    • Bennett D.B., Orr J.F., Baker R. Movement loci of selected points on the femoral head for individual total hip arthroplasty patients using three-dimensional computer simulation. Journal of Arthroplasty. 15:2000;909-915.
    • (2000) Journal of Arthroplasty , vol.15 , pp. 909-915
    • Bennett, D.B.1    Orr, J.F.2    Baker, R.3
  • 4
    • 0036274703 scopus 로고    scopus 로고
    • Analysis of polyethylene particles produced in different wear conditions in vitro
    • Calonius O., Saikko V. Analysis of polyethylene particles produced in different wear conditions in vitro. Clinical Orthopaedics and Related Research. 399:2002;219-230.
    • (2002) Clinical Orthopaedics and Related Research , vol.399 , pp. 219-230
    • Calonius, O.1    Saikko, V.2
  • 6
    • 0024040573 scopus 로고
    • Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints
    • Dowson D., Jobbins B. Design and development of a versatile hip joint simulator and a preliminary assessment of wear and creep in Charnley total replacement hip joints. Engineering in Medicine. 17:1988;111-117.
    • (1988) Engineering in Medicine , vol.17 , pp. 111-117
    • Dowson, D.1    Jobbins, B.2
  • 7
    • 0032605321 scopus 로고    scopus 로고
    • A multi-station hip joint simulator study of the performance of 22mm diameter zirconia-ultra-high molecular polyethylene total replacement hip joints
    • Goldsmith A.A.J., Dowson D. A multi-station hip joint simulator study of the performance of 22. mm diameter zirconia-ultra-high molecular polyethylene total replacement hip joints Journal of Engineering in Medicine. 213:1999;77-90.
    • (1999) Journal of Engineering in Medicine , vol.213 , pp. 77-90
    • Goldsmith, A.A.J.1    Dowson, D.2
  • 9
    • 0014574695 scopus 로고
    • Measurement of hip-joint motion during walking - Evaluation of an electrogoniometric method
    • Johnston R.C., Smidt G.L. Measurement of hip-joint motion during walking - evaluation of an electrogoniometric method. Journal of Bone and Joint Surgery. 51-A:1969;1083-1094.
    • (1969) Journal of Bone and Joint Surgery , vol.51 A , pp. 1083-1094
    • Johnston, R.C.1    Smidt, G.L.2
  • 12
    • 0032079093 scopus 로고    scopus 로고
    • Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties
    • Ramamurti B.S., Estok D.M., Jasty M., Harris W.H. Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties. Journal of Orthopaedic Research. 16:1998;365-369.
    • (1998) Journal of Orthopaedic Research , vol.16 , pp. 365-369
    • Ramamurti, B.S.1    Estok, D.M.2    Jasty, M.3    Harris, W.H.4
  • 13
    • 0030339155 scopus 로고    scopus 로고
    • A three-axis hip joint simulator for wear and friction studies on total hip prostheses
    • Saikko V. A three-axis hip joint simulator for wear and friction studies on total hip prostheses. Journal of Engineering in Medicine. 210:1996;175-185.
    • (1996) Journal of Engineering in Medicine , vol.210 , pp. 175-185
    • Saikko, V.1
  • 14
    • 0032616832 scopus 로고    scopus 로고
    • Type of motion and lubricant in wear simulation of polyethylene acetabular cup
    • Saikko V., Ahlroos T. Type of motion and lubricant in wear simulation of polyethylene acetabular cup. Journal of Engineering in Medicine. 213:1999;301-310.
    • (1999) Journal of Engineering in Medicine , vol.213 , pp. 301-310
    • Saikko, V.1    Ahlroos, T.2
  • 15
    • 0036205442 scopus 로고    scopus 로고
    • Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators
    • Saikko V., Calonius O. Slide track analysis of the relative motion between femoral head and acetabular cup in walking and in hip simulators. Journal of Biomechanics. 35:2002;455-464.
    • (2002) Journal of Biomechanics , vol.35 , pp. 455-464
    • Saikko, V.1    Calonius, O.2
  • 18
    • 0002265178 scopus 로고    scopus 로고
    • Investigations on the wear couple Biolox forte/Biolox forte and earlier alumina materials
    • W. Puhl. Stuttgart: Ferdinand Enke Verlag
    • Walter A. Investigations on the wear couple Biolox forte/Biolox forte and earlier alumina materials. Puhl W. Performance of the Wear Couple Biolox Forte in Hip Arthroplasty. 1997;123-135 Ferdinand Enke Verlag, Stuttgart.
    • (1997) Performance of the Wear Couple Biolox Forte in Hip Arthroplasty , pp. 123-135
    • Walter, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.