메뉴 건너뛰기




Volumn 363, Issue 9406, 2004, Pages 357-362

Non-invasive assessment of hepatic iron stores by MRI

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; BIOACCUMULATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; FEMALE; HUMAN; HUMAN TISSUE; IRON OVERLOAD; LIVER BIOPSY; LIVER LEVEL; MAGNETISM; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; TISSUE DISTRIBUTION;

EID: 0842283228     PISSN: 01406736     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0140-6736(04)15436-6     Document Type: Article
Times cited : (562)

References (30)
  • 2
    • 0033606807 scopus 로고    scopus 로고
    • Iron, atherosclerosis, and ischemic heart disease
    • de Valk B., Marx J.J. Iron, atherosclerosis, and ischemic heart disease. Arch Intern Med. 159:1999;1542-1548.
    • (1999) Arch Intern Med , vol.159 , pp. 1542-1548
    • De Valk, B.1    Marx, J.J.2
  • 3
    • 0032938828 scopus 로고    scopus 로고
    • Elevated parathyroid hormone 44-68 and osteoarticular changes in patients with genetic hemochromatosis
    • Pawlotsky Y., Le Dantec P., Moirand R., et al. Elevated parathyroid hormone 44-68 and osteoarticular changes in patients with genetic hemochromatosis. Arthritis Rheum. 42:1999;799-806.
    • (1999) Arthritis Rheum , vol.42 , pp. 799-806
    • Pawlotsky, Y.1    Le Dantec, P.2    Moirand, R.3
  • 5
    • 0032692722 scopus 로고    scopus 로고
    • Insulin resistance-associated hepatic iron overload
    • Mendler M.H., Turlin B., Moirand R., et al. Insulin resistance- associated hepatic iron overload. Gastroenterology. 117:1999;1155-1163.
    • (1999) Gastroenterology , vol.117 , pp. 1155-1163
    • Mendler, M.H.1    Turlin, B.2    Moirand, R.3
  • 6
    • 0346742414 scopus 로고    scopus 로고
    • Iron overload and public health
    • Deugnier Y., Moirand R. Iron overload and public health. Bull Acad Natl Med. 184:2000;365-373.
    • (2000) Bull Acad Natl Med , vol.184 , pp. 365-373
    • Deugnier, Y.1    Moirand, R.2
  • 7
    • 0002558048 scopus 로고    scopus 로고
    • Haemochromatosis
    • N. McIntyre, J.P. Benhamou, J. Bircher, M. Rizzetto, & J. Rodes. Oxford: Oxford University Press
    • Brissot P., Deugnier Y. Haemochromatosis. McIntyre N., Benhamou J.P., Bircher J., Rizzetto M., Rodes J. Oxford textbook of clinical hepatology. 1999;1379-1391 Oxford University Press, Oxford.
    • (1999) Oxford Textbook of Clinical Hepatology , pp. 1379-1391
    • Brissot, P.1    Deugnier, Y.2
  • 8
    • 0015228412 scopus 로고
    • Measurement of liver-iron concentration in needle-biopsy specimens
    • Barry M., Sherlock S. Measurement of liver-iron concentration in needle-biopsy specimens. Lancet. 1:1971;100-103.
    • (1971) Lancet , vol.1 , pp. 100-103
    • Barry, M.1    Sherlock, S.2
  • 9
    • 0026783157 scopus 로고
    • Magnetic resonance imaging and assessment of liver iron content in genetic hemochromatosis
    • Guyader D., Gandon Y., Robert J.Y., et al. Magnetic resonance imaging and assessment of liver iron content in genetic hemochromatosis. J Hepatol. 15:1992;304-308.
    • (1992) J Hepatol , vol.15 , pp. 304-308
    • Guyader, D.1    Gandon, Y.2    Robert, J.Y.3
  • 10
    • 0024351914 scopus 로고
    • Evaluation of computed tomography in the assessment of liver iron overload: A study of 46 cases of idiopathic hemochromatosis
    • Guyader D., Gandon Y., Deugnier Y., et al. Evaluation of computed tomography in the assessment of liver iron overload: a study of 46 cases of idiopathic hemochromatosis. Gastroenterology. 97:1989;737-743.
    • (1989) Gastroenterology , vol.97 , pp. 737-743
    • Guyader, D.1    Gandon, Y.2    Deugnier, Y.3
  • 11
    • 0020465049 scopus 로고
    • Magnetic-susceptibility measurement of human iron stores
    • Brittenham G.M., Farrell D.E., Harris J.W., et al. Magnetic- susceptibility measurement of human iron stores. N Engl J Med. 307:1982;1671-1675.
    • (1982) N Engl J Med , vol.307 , pp. 1671-1675
    • Brittenham, G.M.1    Farrell, D.E.2    Harris, J.W.3
  • 12
    • 0027945442 scopus 로고
    • Hemochromatosis: Diagnosis and quantification of liver iron with gradient-echo MR imaging
    • Gandon Y., Guyader D., Heautot J.F., et al. Hemochromatosis: diagnosis and quantification of liver iron with gradient-echo MR imaging. Radiology. 193:1994;533-538.
    • (1994) Radiology , vol.193 , pp. 533-538
    • Gandon, Y.1    Guyader, D.2    Heautot, J.F.3
  • 14
  • 15
    • 0030933395 scopus 로고    scopus 로고
    • Natural history of liver fibrosis progression in patients with chronic hepatitis C
    • Poynard T., Bedossa P., Opolon P. Natural history of liver fibrosis progression in patients with chronic hepatitis C. Lancet. 349:1997;825-832.
    • (1997) Lancet , vol.349 , pp. 825-832
    • Poynard, T.1    Bedossa, P.2    Opolon, P.3
  • 16
    • 0036264295 scopus 로고    scopus 로고
    • Theory of nonexponential NMR signal decay in liver with iron overload or superparamagnetic iron oxide particles
    • Jensen J.H., Chandra R. Theory of nonexponential NMR signal decay in liver with iron overload or superparamagnetic iron oxide particles. Magn Reson Med. 47:2002;1131-1138.
    • (2002) Magn Reson Med , vol.47 , pp. 1131-1138
    • Jensen, J.H.1    Chandra, R.2
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1:1986;307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 0025731054 scopus 로고
    • Hepatic iron overload: Paramagnetic pathology
    • Stark D.D. Hepatic iron overload: paramagnetic pathology. Radiology. 179:1991;333-335.
    • (1991) Radiology , vol.179 , pp. 333-335
    • Stark, D.D.1
  • 19
    • 0027285644 scopus 로고
    • Magnetic resonance imaging and different levels of iron overload in chronic liver disease
    • Rocchi E., Cassanelli M., Borghi A., et al. Magnetic resonance imaging and different levels of iron overload in chronic liver disease. Hepatology. 17:1993;997-1002.
    • (1993) Hepatology , vol.17 , pp. 997-1002
    • Rocchi, E.1    Cassanelli, M.2    Borghi, A.3
  • 20
    • 0025230594 scopus 로고
    • Non-invasive quantitation of liver iron-overload by magnetic resonance imaging
    • Kaltwasser J.P., Gottschalk R., Schalk K.P., Hartl W. Non-invasive quantitation of liver iron-overload by magnetic resonance imaging. Br J Haematol. 74:1990;360-363.
    • (1990) Br J Haematol , vol.74 , pp. 360-363
    • Kaltwasser, J.P.1    Gottschalk, R.2    Schalk, K.P.3    Hartl, W.4
  • 21
    • 0025727453 scopus 로고
    • Hepatic iron overload: Quantitative MR imaging
    • Gomori J.M., Horev G., Tamary H., et al. Hepatic iron overload: quantitative MR imaging. Radiology. 179:1991;367-369.
    • (1991) Radiology , vol.179 , pp. 367-369
    • Gomori, J.M.1    Horev, G.2    Tamary, H.3
  • 23
    • 0037964274 scopus 로고    scopus 로고
    • Comparison between signal-to-noise ratio, liver-to-muscle ratio, and 1/ T2 for the noninvasive assessment of liver iron content by MRI
    • Fenzi A., Bortolazzi M., Marzola P. Comparison between signal-to-noise ratio, liver-to-muscle ratio, and 1/T2 for the noninvasive assessment of liver iron content by MRI. J. Magn Reson Imaging. 17:2003;589-592.
    • (2003) J. Magn Reson Imaging , vol.17 , pp. 589-592
    • Fenzi, A.1    Bortolazzi, M.2    Marzola, P.3
  • 24
    • 0034069361 scopus 로고    scopus 로고
    • Quantification of liver iron concentration with magnetic resonance imaging by combining T1-, T2-weighted spin echo sequences and a gradient echo sequence
    • Kreeftenberg H.G. Jr, Mooyaart E.L., Huizenga J.R., Sluiter W.J., Kreeftenberg H.G. Quantification of liver iron concentration with magnetic resonance imaging by combining T1-, T2-weighted spin echo sequences and a gradient echo sequence. Neth J Med. 56:2000;133-137.
    • (2000) Neth J Med , vol.56 , pp. 133-137
    • Kreeftenberg Jr., H.G.1    Mooyaart, E.L.2    Huizenga, J.R.3    Sluiter, W.J.4    Kreeftenberg, H.G.5
  • 25
    • 0001265554 scopus 로고    scopus 로고
    • Variability in hepatic iron concentration measurement from needle-biopsy specimens
    • Villeneuve J.P., Bilodeau M., Lepage R., Cote J., Lefebvre M. Variability in hepatic iron concentration measurement from needle-biopsy specimens. J Hepatol. 25:1996;172-177.
    • (1996) J Hepatol , vol.25 , pp. 172-177
    • Villeneuve, J.P.1    Bilodeau, M.2    Lepage, R.3    Cote, J.4    Lefebvre, M.5
  • 26
    • 0032197577 scopus 로고    scopus 로고
    • Detection of lipid in abdominal tissues with opposed-phase gradient-echo images at 1·5 T: Techniques and diagnostic importance
    • Outwater E.K., Blasbalg R., Siegelman E.S., Vala M. Detection of lipid in abdominal tissues with opposed-phase gradient-echo images at 1·5 T: techniques and diagnostic importance. Radiographics. 18:1998;1465-1480.
    • (1998) Radiographics , vol.18 , pp. 1465-1480
    • Outwater, E.K.1    Blasbalg, R.2    Siegelman, E.S.3    Vala, M.4
  • 27
    • 0031008411 scopus 로고    scopus 로고
    • MR imaging of diffuse liver disease: Hepatic fat and iron
    • Siegelman E.S. MR imaging of diffuse liver disease: hepatic fat and iron. Magn Reson Imaging Clin N Am. 5:1997;347-365.
    • (1997) Magn Reson Imaging Clin N Am , vol.5 , pp. 347-365
    • Siegelman, E.S.1
  • 28
    • 85030905703 scopus 로고    scopus 로고
    • Detection and quantification of liver iron overload using MRI: Multicentric validation
    • Nov 29-Dec 4, 1998; Chicago, IL, USA. Proceedings in Radiology: 209 (P)
    • Gandon Y. Detection and quantification of liver iron overload using MRI: multicentric validation. Proceedings of the Radiological Society of North America. Nov 29-Dec 4, 1998; Chicago, IL, USA. Proceedings in Radiology: 209 (P).
    • Proceedings of the Radiological Society of North America
    • Gandon, Y.1
  • 29
    • 85030908773 scopus 로고    scopus 로고
    • Quantification of hepatic iron concentration using magnetic resonance imaging
    • Nov 26-Dec 1, 2000; Chicago, IL, USA. Proceedings in Radiology: 217 (P)
    • Alustiza J. Quantification of hepatic iron concentration using magnetic resonance imaging. Proceedings of the Radiological Society of North America. Nov 26-Dec 1, 2000; Chicago, IL, USA. Proceedings in Radiology: 217 (P).
    • Proceedings of the Radiological Society of North America
    • Alustiza, J.1
  • 30
    • 0031707469 scopus 로고    scopus 로고
    • Noninvasive prediction of fibrosis in C282Y homozygous hemochromatosis
    • Guyader D., Jacquelinet C., Moirand R., et al. Noninvasive prediction of fibrosis in C282Y homozygous hemochromatosis. Gastroenterology. 115:1998;929-936.
    • (1998) Gastroenterology , vol.115 , pp. 929-936
    • Guyader, D.1    Jacquelinet, C.2    Moirand, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.