메뉴 건너뛰기




Volumn 16, Issue 3, 2003, Pages 292-305

Soft copy display requirements for digital mammography

Author keywords

Digital mammography; Human computer interaction; Image processing; Pan; Softcopy image display; Zoom

Indexed keywords

CLINICAL LABORATORIES; COMPUTER AIDED DIAGNOSIS; COMPUTER SOFTWARE; CORRELATION METHODS; DATA REDUCTION; DISPLAY DEVICES; HUMAN COMPUTER INTERACTION; IMAGE PROCESSING; INTERFACES (COMPUTER); RADIOLOGY;

EID: 2442427227     PISSN: 08971889     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10278-003-1659-6     Document Type: Review
Times cited : (9)

References (26)
  • 1
    • 0020317119 scopus 로고
    • Breast Cancer Detection Demonstration Project: Five-year summary report
    • Baker LH: Breast Cancer Detection Demonstration Project: five-year summary report. CA Cancer J Clin 32:194-225, 1982
    • (1982) CA Cancer J Clin , vol.32 , pp. 194-225
    • Baker, L.H.1
  • 2
    • 0031060826 scopus 로고    scopus 로고
    • A pilot study of eye movement during mammography interpretation: Eye-tracker results and workstation design implications
    • Beard DV, Bream P, Pisano ED, et al: A pilot study of eye movement during mammography interpretation: eye-tracker results and workstation design implications. J Digit Imaging 10:14-20, 1997
    • (1997) J Digit Imaging , vol.10 , pp. 14-20
    • Beard, D.V.1    Bream, P.2    Pisano, E.D.3
  • 3
    • 0027175555 scopus 로고
    • Interpretation of CT studies: Single-screen workstation versus film alternator
    • Beard DV, Hemminger BM, Perry JR, et al: Interpretation of CT studies: single-screen workstation versus film alternator. Radiology 187:565-569, 1993
    • (1993) Radiology , vol.187 , pp. 565-569
    • Beard, D.V.1    Hemminger, B.M.2    Perry, J.R.3
  • 4
    • 0035088227 scopus 로고    scopus 로고
    • Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection
    • Birdwell RL, Ikeda DM, O'Shaughnessy KF, et al: Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection. Radiology 219:192-202, 2001
    • (2001) Radiology , vol.219 , pp. 192-202
    • Birdwell, R.L.1    Ikeda, D.M.2    O'Shaughnessy, K.F.3
  • 5
    • 0032872797 scopus 로고    scopus 로고
    • Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: An ROC study
    • Chan HP, Sahiner B, Helvie MA, et al: Improvement of radiologists' characterization of mammographic masses by using computer-aided diagnosis: an ROC study. Radiology 212:817-827, 1999
    • (1999) Radiology , vol.212 , pp. 817-827
    • Chan, H.P.1    Sahiner, B.2    Helvie, M.A.3
  • 6
    • 16044370409 scopus 로고    scopus 로고
    • Current status of digital mammography
    • Feig SA, Yaffe MJ: Current status of digital mammography. Semin Ultrasound CT MR 17:424-443, 1996
    • (1996) Semin Ultrasound CT MR , vol.17 , pp. 424-443
    • Feig, S.A.1    Yaffe, M.J.2
  • 7
    • 0034860859 scopus 로고    scopus 로고
    • Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center
    • Freer TW, Ulissey MJ: Screening mammography with computer-aided detection: prospective study of 12,860 patients in a community breast center. Radiology 220:781-786, 2001
    • (2001) Radiology , vol.220 , pp. 781-786
    • Freer, T.W.1    Ulissey, M.J.2
  • 9
    • 0034830244 scopus 로고    scopus 로고
    • Improving the detection of simulated masses in mammograms through two different image-processing techniques
    • Hemminger BM, Zong S, Muller KE, et al: Improving the detection of simulated masses in mammograms through two different image-processing techniques. Acad Radiol 8:845-855, 2001
    • (2001) Acad Radiol , vol.8 , pp. 845-855
    • Hemminger, B.M.1    Zong, S.2    Muller, K.E.3
  • 10
    • 0027737472 scopus 로고
    • Establishing a histologic basis for false-negative mammograms
    • Hollingsworth AB, Taylor LD, Rhodes DC: Establishing a histologic basis for false-negative mammograms. Am J Surg 166:643-648, 1993
    • (1993) Am J Surg , vol.166 , pp. 643-648
    • Hollingsworth, A.B.1    Taylor, L.D.2    Rhodes, D.C.3
  • 11
    • 0033277470 scopus 로고    scopus 로고
    • Influence of film and monitor display luminance on observer performance and visual search
    • Krupinski E, Roehrig H, Furukawa T: Influence of film and monitor display luminance on observer performance and visual search. Acad Radiol 6:411-448, 1999
    • (1999) Acad Radiol , vol.6 , pp. 411-448
    • Krupinski, E.1    Roehrig, H.2    Furukawa, T.3
  • 12
    • 0034010317 scopus 로고    scopus 로고
    • Improved mammographic interpretation of masses using computer-aided diagnosis
    • Leichter I, Fields S, Nirel R, et al: Improved mammographic interpretation of masses using computer-aided diagnosis. Eur Radiol 10:377-383, 2000
    • (2000) Eur Radiol , vol.10 , pp. 377-383
    • Leichter, I.1    Fields, S.2    Nirel, R.3
  • 14
    • 0031128575 scopus 로고    scopus 로고
    • Does intensity windowing improve the detection of simulated calcifications in dense mammograms?
    • Pisano ED, Chandramouli J, Hemminger BM, et al: Does intensity windowing improve the detection of simulated calcifications in dense mammograms? J Digit Imaging 10:79-84, 1997
    • (1997) J Digit Imaging , vol.10 , pp. 79-84
    • Pisano, E.D.1    Chandramouli, J.2    Hemminger, B.M.3
  • 15
    • 0031260633 scopus 로고    scopus 로고
    • The effect of intensity windowing on the detection of simulated masses embedded in dense portions of digitized mammograms in a laboratory setting
    • Pisano ED, Chandramouli J, Hemminger BM, et al: The effect of intensity windowing on the detection of simulated masses embedded in dense portions of digitized mammograms in a laboratory setting. J Digit Imaging 10:174-182, 1997
    • (1997) J Digit Imaging , vol.10 , pp. 174-182
    • Pisano, E.D.1    Chandramouli, J.2    Hemminger, B.M.3
  • 16
    • 0034267949 scopus 로고    scopus 로고
    • Image processing algorithms for digital mammography: A pictorial essay
    • Pisano ED, Cole EB, Hemminger BM, et al: Image processing algorithms for digital mammography: a pictorial essay. Radiographies 20:1479-1491, 2000
    • (2000) Radiographies , vol.20 , pp. 1479-1491
    • Pisano, E.D.1    Cole, E.B.2    Hemminger, B.M.3
  • 17
    • 0036239017 scopus 로고    scopus 로고
    • Interpretation of digital mammograms: Comparison of speed and accuracy of soft-copy versus printed-film display
    • Pisano ED, Cole EB, Kistner EO, et al: Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display. Radiology 223:483-488, 2002
    • (2002) Radiology , vol.223 , pp. 483-488
    • Pisano, E.D.1    Cole, E.B.2    Kistner, E.O.3
  • 18
    • 0033837080 scopus 로고    scopus 로고
    • Radiologists' preferences for digital mammographic display
    • The International Digital Mammography Development Group
    • Pisano ED, Cole EB, Major S, et al: Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group. Radiology 216:820-830, 2000
    • (2000) Radiology , vol.216 , pp. 820-830
    • Pisano, E.D.1    Cole, E.B.2    Major, S.3
  • 20
    • 0032194826 scopus 로고    scopus 로고
    • Contrast limited adaptive histogram equalization image processing to improve the detection of simulated speculations in dense mammograms
    • Pisano ED, Zong S, Hemminger BM, et al: Contrast limited adaptive histogram equalization image processing to improve the detection of simulated speculations in dense mammograms. J Digit Imaging 11:193-200, 1998
    • (1998) J Digit Imaging , vol.11 , pp. 193-200
    • Pisano, E.D.1    Zong, S.2    Hemminger, B.M.3
  • 22
    • 0028538168 scopus 로고
    • A method for determination of optimal image enhancement for the detection of mammographic abnormalities
    • Puff DT, Pisano ED, Muller KE, et al: A method for determination of optimal image enhancement for the detection of mammographic abnormalities. J Digit Imaging 7:161-171, 1994
    • (1994) J Digit Imaging , vol.7 , pp. 161-171
    • Puff, D.T.1    Pisano, E.D.2    Muller, K.E.3
  • 24
    • 0026734920 scopus 로고
    • Digital mammography and related technologies: A perspective from the National Cancer Institute
    • Shtern F: Digital mammography and related technologies: a perspective from the National Cancer Institute. Radiology 183:629-630, 1992
    • (1992) Radiology , vol.183 , pp. 629-630
    • Shtern, F.1
  • 25
    • 0033107788 scopus 로고    scopus 로고
    • Report of Working Group on Digital Mammography: Digital Displays and Workstation Design
    • Shtern F, Winfield DW, Behlen F, et al: Report of Working Group on Digital Mammography: Digital Displays and Workstation Design. Academic Radiology 6:197-218, 1999
    • (1999) Academic Radiology , vol.6 , pp. 197-218
    • Shtern, F.1    Winfield, D.W.2    Behlen, F.3
  • 26
    • 0031372817 scopus 로고    scopus 로고
    • Image quality assessment of monochrome monitors for medical softcopy display
    • Weibrecht M, Spekowius G, Quadflieg P, et al: Image quality assessment of monochrome monitors for medical softcopy display. Proc SPIE 3031:232-244, 1997
    • (1997) Proc SPIE , vol.3031 , pp. 232-244
    • Weibrecht, M.1    Spekowius, G.2    Quadflieg, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.