메뉴 건너뛰기




Volumn 17, Issue 5, 1996, Pages 424-443

Current status of digital mammography

Author keywords

[No Author keywords available]

Indexed keywords

BREAST TUMOR; COMPUTER ANALYSIS; COMPUTER ASSISTED DIAGNOSIS; DIGITAL RADIOGRAPHY; ECHOMAMMOGRAPHY; FEMALE; HUMAN; HUMAN TISSUE; IMAGE ANALYSIS; IMAGE PROCESSING; MAMMOGRAPHY; PRIORITY JOURNAL; REVIEW;

EID: 16044370409     PISSN: 08872171     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0887-2171(96)90029-3     Document Type: Article
Times cited : (37)

References (28)
  • 1
    • 0023196389 scopus 로고
    • X-ray characterization of normal and neoplastic breast tissues
    • Johns PC, Yaffe MJ: X-ray characterization of normal and neoplastic breast tissues. Phys Med Biol 32:675-695, 1987
    • (1987) Phys Med Biol , vol.32 , pp. 675-695
    • Johns, P.C.1    Yaffe, M.J.2
  • 2
    • 0025858287 scopus 로고
    • The American College of Radiology Mammography Accreditation Program
    • McLelland R, Hendrick RG, Wilcox P, et al: The American College of Radiology Mammography Accreditation Program. AJR Am J Roentgenol 157:473-479, 1991
    • (1991) AJR Am J Roentgenol , vol.157 , pp. 473-479
    • McLelland, R.1    Hendrick, R.G.2    Wilcox, P.3
  • 5
    • 0037499148 scopus 로고
    • Small field digital mammography with 2048 × 2048 pixel charge-coupled device
    • Karellas A, Harris LJ, D'Orsi CJ: Small field digital mammography with 2048 × 2048 pixel charge-coupled device. Radiology 177(P):288-289, 1990
    • (1990) Radiology , vol.177 , Issue.P , pp. 288-289
    • Karellas, A.1    Harris, L.J.2    D'Orsi, C.J.3
  • 6
    • 0002570816 scopus 로고
    • Photostimulable phosphor radiology design considerations
    • Seibert JA, Barnes GT, Gould RG (eds) Woodbury, NY, American Institute of Physics, Monograph No. 20
    • Kato H: Photostimulable phosphor radiology design considerations, in Seibert JA, Barnes GT, Gould RG (eds): Specification, Acceptance Testing and Quality Control of Diagnostic X-Ray Imaging Equipment. Woodbury, NY, American Institute of Physics, Monograph No. 20, 1994, pp 303-357
    • (1994) Specification, Acceptance Testing and Quality Control of Diagnostic X-Ray Imaging Equipment , pp. 303-357
    • Kato, H.1
  • 7
    • 0004017051 scopus 로고
    • Direct x-ray photoconversion processes
    • Hendee WR, Trueblood JH (eds) Madison, WI, Medical Physics Publishing
    • Rougeot H: Direct x-ray photoconversion processes, in Hendee WR, Trueblood JH (eds): Digital Imaging. Madison, WI, Medical Physics Publishing, 1993, pp 49-96
    • (1993) Digital Imaging , pp. 49-96
    • Rougeot, H.1
  • 9
    • 0025845656 scopus 로고
    • X-ray imaging using amorphous selenium: A photoinduced discharge readout method for digital mammography
    • Rowlands JA, Hunter DM, Araj N: X-ray imaging using amorphous selenium: A photoinduced discharge readout method for digital mammography. Med Phys 18:421-431, 1991
    • (1991) Med Phys , vol.18 , pp. 421-431
    • Rowlands, J.A.1    Hunter, D.M.2    Araj, N.3
  • 10
    • 0029454830 scopus 로고
    • Digital radiology using self-scanned readout of amorphous selenium: Design considerations for mammography
    • Society of Photo-Optical Instrumentation Engineers
    • Zhao W, Rowlands JA, German S: Digital radiology using self-scanned readout of amorphous selenium: Design considerations for mammography. Proc SPIE (Society of Photo-Optical Instrumentation Engineers) 2432:250-259, 1995
    • (1995) Proc SPIE , vol.2432 , pp. 250-259
    • Zhao, W.1    Rowlands, J.A.2    German, S.3
  • 11
    • 0029458793 scopus 로고
    • New digital detector for projection radiography
    • Lee DL, Cheung LK, Jeromin LS: New digital detector for projection radiography. Proc SPIE 2432:237-249, 1995
    • (1995) Proc SPIE , vol.2432 , pp. 237-249
    • Lee, D.L.1    Cheung, L.K.2    Jeromin, L.S.3
  • 12
    • 0027141897 scopus 로고
    • Dynamic range requirements of x-ray detectors for digital mammography
    • Maidment ADA, Fahrig R, Yaffe MJ: Dynamic range requirements of x-ray detectors for digital mammography. Med Phys 20:1621-1633, 1993
    • (1993) Med Phys , vol.20 , pp. 1621-1633
    • Maidment, A.D.A.1    Fahrig, R.2    Yaffe, M.J.3
  • 14
    • 0028212598 scopus 로고
    • Computer vision and artificial intelligence in mammography
    • Vyborny CJ, Giger ML: Computer vision and artificial intelligence in mammography. AJR Am J Roentgenol 162:699-708, 1994
    • (1994) AJR Am J Roentgenol , vol.162 , pp. 699-708
    • Vyborny, C.J.1    Giger, M.L.2
  • 15
    • 0028288299 scopus 로고
    • Can computers help radiologists read mammograms?
    • Vyborny CJ: Can computers help radiologists read mammograms? Radiology 191:315-317, 1994
    • (1994) Radiology , vol.191 , pp. 315-317
    • Vyborny, C.J.1
  • 16
    • 0026655955 scopus 로고
    • Analysis of cancers missed at screening mammography
    • Bird RE, Wallace TW, Yankaskas BC: Analysis of cancers missed at screening mammography. Radiology 184: 613-617, 1992
    • (1992) Radiology , vol.184 , pp. 613-617
    • Bird, R.E.1    Wallace, T.W.2    Yankaskas, B.C.3
  • 17
    • 0028230453 scopus 로고
    • Benefit of independent double reading in a population-based mammography screening program
    • Thurfjell EL, Lernevall KA, Taube AAS: Benefit of independent double reading in a population-based mammography screening program. Radiology 191:241-244, 1994
    • (1994) Radiology , vol.191 , pp. 241-244
    • Thurfjell, E.L.1    Lernevall, K.A.2    Taube, A.A.S.3
  • 18
    • 0027144471 scopus 로고
    • Computer-aided detection of clustered microcalcifications: An improved method for grouping detected signals
    • Nishikawa RM, Giger ML, Doi K, et al: Computer-aided detection of clustered microcalcifications: An improved method for grouping detected signals. Med Phys 20:1661-1666, 1993
    • (1993) Med Phys , vol.20 , pp. 1661-1666
    • Nishikawa, R.M.1    Giger, M.L.2    Doi, K.3
  • 19
    • 0028373095 scopus 로고
    • Computerized detection of masses in digital mammograms: Investigation of feature-analysis techniques
    • Yin FF, Giger ML, Doi K, et al: Computerized detection of masses in digital mammograms: investigation of feature-analysis techniques. J Digital Imaging 7:18-26, 1994
    • (1994) J Digital Imaging , vol.7 , pp. 18-26
    • Yin, F.F.1    Giger, M.L.2    Doi, K.3
  • 20
    • 0025080985 scopus 로고
    • Improvement in radiologists' detection of clustered microcalcifications on mammograms: The potential of computer-aided diagnosis
    • Chan HP, Doi K, Vyborny CJ, et al: Improvement in radiologists' detection of clustered microcalcifications on mammograms: The potential of computer-aided diagnosis. Invest Radiol 25:1102-1110, 1990
    • (1990) Invest Radiol , vol.25 , pp. 1102-1110
    • Chan, H.P.1    Doi, K.2    Vyborny, C.J.3
  • 21
    • 0028263085 scopus 로고
    • Computer-aided mammographic screening for spiculated lesions
    • Kegelmeyer WP Jr, Pruneda JM, Bourland PD, et al: Computer-aided mammographic screening for spiculated lesions. Radiology 191:331-337, 1994
    • (1994) Radiology , vol.191 , pp. 331-337
    • Kegelmeyer Jr., W.P.1    Pruneda, J.M.2    Bourland, P.D.3
  • 22
    • 0029263789 scopus 로고
    • Computer-ized detection of clustered microcalcifications: Evaluation of performance on mammograms from multiple centers
    • Nishikawa RM, Doi K, Giger ML, et al: Computer-ized detection of clustered microcalcifications: Evaluation of performance on mammograms from multiple centers. Radiographies 15:443-452, 1995
    • (1995) Radiographies , vol.15 , pp. 443-452
    • Nishikawa, R.M.1    Doi, K.2    Giger, M.L.3
  • 23
    • 0027983046 scopus 로고
    • Effect of case selection on performance of computer aided detection schemes
    • Nishikawa RM, Giger ML, Doi K, et al: Effect of case selection on performance of computer aided detection schemes. Med Phys 21:265-269, 1994
    • (1994) Med Phys , vol.21 , pp. 265-269
    • Nishikawa, R.M.1    Giger, M.L.2    Doi, K.3
  • 24
    • 0025625908 scopus 로고
    • Investigation of methods for the computerized detection and analysis of mammographic masses
    • Giger ML, Yin FF, Doi K, et al: Investigation of methods for the computerized detection and analysis of mammographic masses. Proc SPIE 1233:183-184, 1990
    • (1990) Proc SPIE , vol.1233 , pp. 183-184
    • Giger, M.L.1    Yin, F.F.2    Doi, K.3
  • 25
    • 0025787037 scopus 로고
    • Expert learning system network for diagnosis of breast calcifications
    • Patrick EA, Moskowitz M, Mansukhani VT, et al: Expert learning system network for diagnosis of breast calcifications. Invest Radiol 16:534-539, 1991
    • (1991) Invest Radiol , vol.16 , pp. 534-539
    • Patrick, E.A.1    Moskowitz, M.2    Mansukhani, V.T.3
  • 28
    • 0347722165 scopus 로고
    • Experience with a proposed teleradiology system for digital mammography
    • Abdel-Malek A: Experience with a proposed teleradiology system for digital mammography. Proc SPIE 2435:200-209, 1995
    • (1995) Proc SPIE , vol.2435 , pp. 200-209
    • Abdel-Malek, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.