메뉴 건너뛰기




Volumn 15, Issue 4, 2005, Pages 317-331

Analysis of the effects of different materials in a tooth implant-supported fixed prosthesis using finite element method

Author keywords

Dental implant; FEA; Fixed prosthesis; Modeling; Three dimensional

Indexed keywords

COMPUTER SIMULATION; DEFLECTION (STRUCTURES); DEFORMATION; DENTAL PROSTHESES; ELASTIC MODULI; FINITE ELEMENT METHOD; MATHEMATICAL MODELS; STRESS ANALYSIS; STRESS CONCENTRATION;

EID: 22244493952     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (37)
  • 2
    • 0035434691 scopus 로고    scopus 로고
    • The influence of plaque and/or excessive loading on marginal soft and hard tissue reactions around Branemark implants: A review of literature and experience
    • E. De Smet, D. van Steenberghe, M. Quirynen and I. Naert, The influence of plaque and/or excessive loading on marginal soft and hard tissue reactions around Branemark implants: a review of literature and experience, International Journal of Periodontics and Restorative Dentistry 21 (2001), 381-393.
    • (2001) International Journal of Periodontics and Restorative Dentistry , vol.21 , pp. 381-393
    • De Smet, E.1    Van Steenberghe, D.2    Quirynen, M.3    Naert, I.4
  • 4
    • 1642377232 scopus 로고    scopus 로고
    • Theoretical and experimental analysis of a piezoelectric tactile sensor for use in endoscopic surgery
    • Accepted for publication, to appear in
    • J. Dargahi and S. Najarian, Theoretical and experimental analysis of a piezoelectric tactile sensor for use in endoscopic surgery, Sensor Review, Accepted for publication, to appear in 24(1) (2004).
    • (2004) Sensor Review , vol.24 , Issue.1
    • Dargahi, J.1    Najarian, S.2
  • 5
    • 0346848861 scopus 로고    scopus 로고
    • Optimization of the geometry of total knee implant in the sagittal plane using FEA
    • J. Dargahi, S. Najarian and S. Amiri, Optimization of the geometry of total knee implant in the sagittal plane using FEA, Bio-Medical Materials and Engineering 13(4) (2003), 439-449.
    • (2003) Bio-Medical Materials and Engineering , vol.13 , Issue.4 , pp. 439-449
    • Dargahi, J.1    Najarian, S.2    Amiri, S.3
  • 8
    • 0035027388 scopus 로고    scopus 로고
    • Improvement of the Pennes equation in the analysis of heat transfer phenomenon in blood perfused tissues
    • S. Najarian and A. Pashaee, Improvement of the Pennes equation in the analysis of heat transfer phenomenon in blood perfused tissues, Biomedical Sciences Instrumentation 38 (2001), 185-190.
    • (2001) Biomedical Sciences Instrumentation , vol.38 , pp. 185-190
    • Najarian, S.1    Pashaee, A.2
  • 11
    • 0026892027 scopus 로고
    • Stress distribution around dental implant: Influence of superstructure, length of implants, and height of mandible
    • H.J. Meijer, J.H. Kuiper, F.J. Starmans and F. Bosman, Stress distribution around dental implant: influence of superstructure, length of implants, and height of mandible, Journal of Prosthetic Dentistry 68 (1992), 96-102.
    • (1992) Journal of Prosthetic Dentistry , vol.68 , pp. 96-102
    • Meijer, H.J.1    Kuiper, J.H.2    Starmans, F.J.3    Bosman, F.4
  • 12
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite-element analysis in implant dentistry: A review of the literature
    • J.P. Geng, K.B.C. Tan and G.R. Liu, Application of finite-element analysis in implant dentistry: a review of the literature, Journal of Prosthetic Dentistry 85 (2001), 585-598.
    • (2001) Journal of Prosthetic Dentistry , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.C.2    Liu, G.R.3
  • 14
    • 0030224418 scopus 로고    scopus 로고
    • Comparison of stress distribution around vertical and angled implants with finite-element analysis
    • S. Canay, N. Hersek, I. Akpinar and Z. Asik, Comparison of stress distribution around vertical and angled implants with finite-element analysis, Quintessence International 27 (1996), 591-598.
    • (1996) Quintessence International , vol.27 , pp. 591-598
    • Canay, S.1    Hersek, N.2    Akpinar, I.3    Asik, Z.4
  • 15
    • 0027792619 scopus 로고
    • A method of selecting the best implant prosthesis design option using three-dimensional finite element analysis
    • M. Kregzde, A method of selecting the best implant prosthesis design option using three-dimensional finite element analysis, Journal of Cranio-Maxillofacial Surgery 8 (1993), 662-673.
    • (1993) Journal of Cranio-Maxillofacial Surgery , vol.8 , pp. 662-673
    • Kregzde, M.1
  • 17
    • 0029678751 scopus 로고    scopus 로고
    • A comparison of stress and strain distribution characteristics of two different rigid implant designs for distal-extension fixed prostheses
    • I. Akpinar, F. Demirel, L. Parnas and S. Sahin, A comparison of stress and strain distribution characteristics of two different rigid implant designs for distal-extension fixed prostheses, Quintessence International 27 (1996), 11-17.
    • (1996) Quintessence International , vol.27 , pp. 11-17
    • Akpinar, I.1    Demirel, F.2    Parnas, L.3    Sahin, S.4
  • 18
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis: A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • E.P. Holmgren, R.J. Seckinger, L.M. Kilgren and F. Mante, Evaluating parameters of osseointegrated dental implants using finite element analysis: a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction, Journal of Oral Implantology 24 (1998), 80-88.
    • (1998) Journal of Oral Implantology , vol.24 , pp. 80-88
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 19
    • 0034303173 scopus 로고    scopus 로고
    • Implant-retained cantilever fixed prosthesis: Where and when
    • C.M. Becker and D.A. Kaiser, Implant-retained cantilever fixed prosthesis: where and when, Journal of Prosthetic Dentistry 84 (2000), 432-435.
    • (2000) Journal of Prosthetic Dentistry , vol.84 , pp. 432-435
    • Becker, C.M.1    Kaiser, D.A.2
  • 20
    • 0038505307 scopus 로고    scopus 로고
    • Cyclic loading of implant-supported prostheses: Changes in component fit over time
    • D.M. Hecker and E. Eckert, Cyclic loading of implant-supported prostheses: changes in component fit over time, Journal of Prosthetic Dentistry 89 (2003), 346-351.
    • (2003) Journal of Prosthetic Dentistry , vol.89 , pp. 346-351
    • Hecker, D.M.1    Eckert, E.2
  • 21
    • 0035011470 scopus 로고    scopus 로고
    • Bone loading pattern around implants in average and atrophic edentulous maxillae: A finite element analysis
    • U. Meyer, D. Vollmer, C. Runte, C. Bourauel and U. Joos, Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite element analysis, Journal of Cranio-Maxillofacial Surgery 29 (2001), 100-105.
    • (2001) Journal of Cranio-Maxillofacial Surgery , vol.29 , pp. 100-105
    • Meyer, U.1    Vollmer, D.2    Runte, C.3    Bourauel, C.4    Joos, U.5
  • 22
    • 0031598192 scopus 로고    scopus 로고
    • Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method
    • F.A. Young, K.R. Williams, R. Draughn and R. Strohaver, Design of prosthetic cantilever bridgework supported by osseointegrated implants using the finite element method, Dental Materials 14 (1998), 37-43.
    • (1998) Dental Materials , vol.14 , pp. 37-43
    • Young, F.A.1    Williams, K.R.2    Draughn, R.3    Strohaver, R.4
  • 23
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prosthesis
    • R. Skalak, Biomechanical considerations in osseointegrated prosthesis, Journal of Prosthetic Dentistry 49 (1983), 843-848.
    • (1983) Journal of Prosthetic Dentistry , vol.49 , pp. 843-848
    • Skalak, R.1
  • 24
    • 0026823748 scopus 로고
    • Determining the force absorption on quotient for restorative materials used in implant occlusal surfaces
    • R.M. Cibirka, M.E. Razzoog, B.R. Lang and C.S. Stohler, Determining the force absorption on quotient for restorative materials used in implant occlusal surfaces, Journal of Prosthetic Dentistry 67 (1992), 361-364.
    • (1992) Journal of Prosthetic Dentistry , vol.67 , pp. 361-364
    • Cibirka, R.M.1    Razzoog, M.E.2    Lang, B.R.3    Stohler, C.S.4
  • 25
    • 0033158247 scopus 로고    scopus 로고
    • Influence of mandibular superstructure shape on implant stresses during simulated posterior biting
    • T.W. Korioth and A.R. Johann, Influence of mandibular superstructure shape on implant stresses during simulated posterior biting, Journal of Prosthetic Dentistry 82 (1999), 67-72.
    • (1999) Journal of Prosthetic Dentistry , vol.82 , pp. 67-72
    • Korioth, T.W.1    Johann, A.R.2
  • 26
    • 0030621894 scopus 로고    scopus 로고
    • Finite element analysis study of the effect of superstructure material on stress distribution in a fixed prosthesis
    • A. Sertgöz, Finite element analysis study of the effect of superstructure material on stress distribution in a fixed prosthesis, International Journal of Prosthodontics 10(1) (1997), 19-27.
    • (1997) International Journal of Prosthodontics , vol.10 , Issue.1 , pp. 19-27
    • Sertgöz, A.1
  • 27
    • 0030208125 scopus 로고    scopus 로고
    • Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant supported prosthesis
    • A. Sertgöz and S. Güvener, Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant supported prosthesis, Journal of Prosthetic Dentistry 76 (1996), 165-169.
    • (1996) Journal of Prosthetic Dentistry , vol.76 , pp. 165-169
    • Sertgöz, A.1    Güvener, S.2
  • 28
    • 84964416539 scopus 로고
    • Cobalt chromium as a framework material in implant supported fixed prostheses: A 3-year follow-up
    • M. Hulterstrom and U. Nilsson, Cobalt chromium as a framework material in implant supported fixed prostheses: A 3-year follow-up, International Journal of Oral Maxillafacial Implants 9 (1994), 165-184.
    • (1994) International Journal of Oral Maxillafacial Implants , vol.9 , pp. 165-184
    • Hulterstrom, M.1    Nilsson, U.2
  • 30
    • 0024836867 scopus 로고
    • The influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentition with implant-supported fixed prostheses occluding with complete dentures
    • D. Lundgren, H. Falk and L. Laurell, The influence of number and distribution of occlusal cantilever contacts on closing and chewing forces in dentition with implant-supported fixed prostheses occluding with complete dentures, International Journal of Oral Maxillafacial Implants 4 (1989), 277-283.
    • (1989) International Journal of Oral Maxillafacial Implants , vol.4 , pp. 277-283
    • Lundgren, D.1    Falk, H.2    Laurell, L.3
  • 33
  • 34
    • 0034011307 scopus 로고    scopus 로고
    • Biaxial residual stress states of plasma-sprayed hydroxyapatite coatings on titanium alloy substrate
    • Y.C. Yang, E. Chang, B.H. Hwang and S.Y. Lee, Biaxial residual stress states of plasma-sprayed hydroxyapatite coatings on titanium alloy substrate, Biomaterials 21 (2000), 1327-1337.
    • (2000) Biomaterials , vol.21 , pp. 1327-1337
    • Yang, Y.C.1    Chang, E.2    Hwang, B.H.3    Lee, S.Y.4
  • 35
    • 0026976828 scopus 로고
    • Finite element stress and strain analysis of the bone surrounding a dental implant: Effect of variations in bone modulus
    • S.E. Clift, J. Fisher and C.J. Watson, Finite element stress and strain analysis of the bone surrounding a dental implant: effect of variations in bone modulus, Proceedings of the Institute of Mechanical Engineering: Part H 206 (1992), 233-241.
    • (1992) Proceedings of the Institute of Mechanical Engineering: Part H , vol.206 , pp. 233-241
    • Clift, S.E.1    Fisher, J.2    Watson, C.J.3
  • 37
    • 0029263858 scopus 로고
    • Biomechanical aspects of two different implant-prosthetic concepts for edentulous maxillae
    • U.R. Benzing, H. Gall and H. Weber, Biomechanical aspects of two different implant-prosthetic concepts for edentulous maxillae, International Journal of Oral Maxillafacial Implants 10 (1995), 188-198.
    • (1995) International Journal of Oral Maxillafacial Implants , vol.10 , pp. 188-198
    • Benzing, U.R.1    Gall, H.2    Weber, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.