Craniofacial Osseointegrated Implant-Induced Strain Distribution: A Numerical Study

Author keywords

Biomechanics; Craniofacial osseointegrated implant; Finite element model; Strain

Indexed keywords

TITANIUM;

EID: 0031086463     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (28)

References (15)
  • 1
    • 0024198247 scopus 로고
    • Bone tissue, interface
    • Roberts WE. Bone tissue, interface. J Dent Educ 1988;52: 804-809.
    • (1988) J Dent Educ , vol.52 , pp. 804-809
    • Roberts, W.E.1
  • 2
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone-dental implant interface
    • Brunski JB. Biomechanical factors affecting the bone-dental implant interface. Clin Mater 1992;10:153-201.
    • (1992) Clin Mater , vol.10 , pp. 153-201
    • Brunski, J.B.1
  • 3
    • 85016033318 scopus 로고
    • Mechanical loading of Brånemark implants affeding interfacial bone modeling and remodeling
    • Hoshaw SJ, Brunski JB, Coechran GVB. Mechanical loading of Brånemark implants affeding interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Coechran, G.V.B.3
  • 4
    • 0023173665 scopus 로고
    • The Mechanostat: A proposed pathogenic mcchanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents
    • Frost HM. The Mechanostat: A proposed pathogenic mcchanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents, Bone Mineral 1987;2:73-85.
    • (1987) Bone Mineral , vol.2 , pp. 73-85
    • Frost, H.M.1
  • 7
    • 0027829234 scopus 로고
    • Nonlinear finite element contact analysis of dental implant components
    • Sakaguchi RL, Borgerson SE. Nonlinear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants 1993;8:655-661.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 655-661
    • Sakaguchi, R.L.1    Borgerson, S.E.2
  • 8
    • 0027792619 scopus 로고
    • A method of selecting the best implant prosthesis design option using three-dimensional Finite element analysis
    • Kregzde M. A method of selecting the best implant prosthesis design option using three-dimensional Finite element analysis. Int J Oral Maxillofac Implants 1993;8:662-673.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 662-673
    • Kregzde, M.1
  • 9
    • 84989001629 scopus 로고
    • Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants
    • Waskewicz GA, Ostrowski JS, Parks VJ. Photoelastic analysis of stress distribution transmitted from a fixed prosthesis attached to osseointegrated implants. Int J Oral Maxillofac Implants 1904;9:405-411.
    • (1904) Int J Oral Maxillofac Implants , vol.9 , pp. 405-411
    • Waskewicz, G.A.1    Ostrowski, J.S.2    Parks, V.J.3
  • 12
    • 0023460248 scopus 로고
    • Finite element analysis of partially edentulous mandible rehabilitated with an osteointegrated cylindrical implant
    • Meroueh KA, Watanabe F, Mentag PJ. Finite element analysis of partially edentulous mandible rehabilitated with an osteointegrated cylindrical implant. J Oral Implantol 1987;2:215-237.
    • (1987) J Oral Implantol , vol.2 , pp. 215-237
    • Meroueh, K.A.1    Watanabe, F.2    Mentag, P.J.3
  • 14
    • 0024740486 scopus 로고
    • Finite element analysis of bone-adapted and bone-bonded endosseons implants
    • Rieger MR, Adams WK, Kinzel GL, Brose MO. Finite element analysis of bone-adapted and bone-bonded endosseons implants. J Prosthet Dent 1989;4:436-440.
    • (1989) J Prosthet Dent , vol.4 , pp. 436-440
    • Rieger, M.R.1    Adams, W.K.2    Kinzel, G.L.3    Brose, M.O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.