Volumn 5651, Issue , 2005, Pages 204-213

Polymer microfluidic device replacing fluids using only capillary force

Author keywords

Capillary force; Hot embossing; Polymer; Selfwash; Stop valve; Surface tension

Indexed keywords

CAPILLARY FLOW; CHEMICAL MECHANICAL POLISHING; POLYMERS; POLYMETHYL METHACRYLATES; PROTEINS; SURFACE ACTIVE AGENTS; SURFACE TENSION; VALVES (MECHANICAL);

EID: 21844446615     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.582277     Document Type: Conference Paper
Times cited : (2)

References (25)
  • 1
    • 0037096666 scopus 로고    scopus 로고
    • Micro total analysis systems. 1. Introduction, theory, and technology
    • D. R. Reyes, D. lossifidis, P. A. Auroux and A. Manz, "Micro Total Analysis Systems. 1. Introduction, Theory, and Technology", Anal Chem., Vol. 74, no. 12, pp.2623-2636, 2002.
    • (2002) Anal Chem. , vol.74 , Issue.12 , pp. 2623-2636
    • Reyes, D.R.1    Lossifidis, D.2    Auroux, P.A.3    Manz, A.4
  • 2
    • 0037096670 scopus 로고    scopus 로고
    • Micro total analysis systems. 2. Analytical standard operations and applications
    • P. A. Auroux, D. Iossifidis, D. R. Reyes, and A. Manz, "Micro Total Analysis Systems. 2. Analytical Standard operations and applications", Anal Chem., Vol. 74, no. 12, pp.2637-2652, 2002.
    • (2002) Anal Chem. , vol.74 , Issue.12 , pp. 2637-2652
    • Auroux, P.A.1    Iossifidis, D.2    Reyes, D.R.3    Manz, A.4
  • 3
    • 0000466510 scopus 로고    scopus 로고
    • Fluids for Sensor systems
    • S. Shoji, "Fluids for Sensor systems", Topics in Current Chemistry, Vol. 194, pp. 163-188, 1998.
    • (1998) Topics in Current Chemistry , vol.194 , pp. 163-188
    • Shoji, S.1
  • 4
    • 1542786313 scopus 로고    scopus 로고
    • Micro-electro-mechanical systems(MEMS) and fluid flows
    • C. M. Ho and Y. C. Tai, "Micro-electro-mechanical systems(MEMS) and fluid flows", Annu. Rev. Fluid Mech., vol. 30, pp.579-612, 1998.
    • (1998) Annu. Rev. Fluid Mech. , vol.30 , pp. 579-612
    • Ho, C.M.1    Tai, Y.C.2
  • 5
    • 0034908917 scopus 로고    scopus 로고
    • Microfluidics-downsizing large-scale biology
    • P. Mitchell, "Microfluidics-downsizing large-scale biology", Nature Biotechnology, vol. 19, pp.717-721, 2001.
    • (2001) Nature Biotechnology , vol.19 , pp. 717-721
    • Mitchell, P.1
  • 6
    • 1242351491 scopus 로고    scopus 로고
    • Integrated microfluidic devices
    • D. Erickson and D. Li, "Integrated microfluidic devices", Analytica Chimica Acta, vol. 507, pp. 11-26, 2004.
    • (2004) Analytica Chimica Acta , vol.507 , pp. 11-26
    • Erickson, D.1    Li, D.2
  • 7
    • 0032632334 scopus 로고    scopus 로고
    • The fluid mechanics of microdevices-the freeman scholar lecture
    • M. Gad-el-Hak, "The fluid mechanics of microdevices-the freeman scholar lecture", J. of Fluids Engineering, vol 121, pp.5-33, 1999
    • (1999) J. of Fluids Engineering , vol.121 , pp. 5-33
    • Gad-El-Hak, M.1
  • 8
    • 0034319954 scopus 로고    scopus 로고
    • Utilization of surface tension and wettability in the design and operation of microsensors
    • P. G. Wapner and W. P. Huffman, "Utilization of surface tension and wettability in the design and operation of microsensors", Sensors and Actuators B, Vol. 71, pp.60-67, 2000.
    • (2000) Sensors and Actuators B , vol.71 , pp. 60-67
    • Wapner, P.G.1    Huffman, W.P.2
  • 9
    • 1842695585 scopus 로고
    • Wetting: Statics and dynamics
    • P. G. de Gennes, "Wetting: statics and dynamics", Reviews of Modern Physics, vol. 57, no. 3, pp.827-862, 1985.
    • (1985) Reviews of Modern Physics , vol.57 , Issue.3 , pp. 827-862
    • De Gennes, P.G.1
  • 13
    • 0036572852 scopus 로고    scopus 로고
    • Micro-channel filling flow considering surface tension effect
    • D. S. Kim, K. C. Lee. T. H. Kwon and S. S. Lee, "Micro-channel filling flow considering surface tension effect", J. Micromech. Microeng., Vol.12, pp.236-246, 2002.
    • (2002) J. Micromech. Microeng. , vol.12 , pp. 236-246
    • Kim, D.S.1    Lee, K.C.2    Kwon, T.H.3    Lee, S.S.4
  • 15
    • 0031555724 scopus 로고    scopus 로고
    • Imbibition and flow of wetting liquids in noncircular capillaries
    • E. Kim and G. M. Whitesides, "Imbibition and flow of wetting liquids in noncircular capillaries", J. Phys. Chem. B, Vol. 101, pp.855-863, 1997.
    • (1997) J. Phys. Chem. B , vol.101 , pp. 855-863
    • Kim, E.1    Whitesides, G.M.2
  • 19
    • 1242301079 scopus 로고    scopus 로고
    • Rapid droplet mixer for digital microfluidic systems
    • P. Paik, V. K. Pamula and R. B. Fair, "Rapid droplet mixer for digital microfluidic systems", Lab Chip, Vol. 3, pp.253-259. 2003.
    • (2003) Lab Chip , vol.3 , pp. 253-259
    • Paik, P.1    Pamula, V.K.2    Fair, R.B.3
  • 20
    • 0034282965 scopus 로고    scopus 로고
    • Nanoliter liquid metering in microchannels using hydrophobic patterns
    • K. Handique, D. T. Burke, C. H. Mastrangelo and M. A. Burns, "Nanoliter liquid metering in microchannels using hydrophobic patterns", Anal. Chem., Vol. 72, pp.4100-4109, 2000.
    • (2000) Anal. Chem. , vol.72 , pp. 4100-4109
    • Handique, K.1    Burke, D.T.2    Mastrangelo, C.H.3    Burns, M.A.4
  • 22
    • 0035008302 scopus 로고    scopus 로고
    • Micropump driven continuous electrowetting actuation for low voltage and low power operation
    • K. S. Yun, I. J. Cho, J. U. Bu, G. H. Kim, Y. S. Jeon, C. H. Kim and E. Yoon, "Micropump driven continuous electrowetting actuation for low voltage and low power operation", in Proceedings of IEEE MEMS, pp. 487-490, 2001.
    • (2001) Proceedings of IEEE MEMS , pp. 487-490
    • Yun, K.S.1    Cho, I.J.2    Bu, J.U.3    Kim, G.H.4    Jeon, Y.S.5    Kim, C.H.6    Yoon, E.7
  • 23
    • 0031682459 scopus 로고    scopus 로고
    • Liquid micromotor driven by continuous electrowetting
    • J. H. Lee and C. J. Kim, "Liquid micromotor driven by continuous electrowetting", in Proceedings of IEEE MEMS, pp. 538-543, 1998.
    • (1998) Proceedings of IEEE MEMS , pp. 538-543
    • Lee, J.H.1    Kim, C.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.