메뉴 건너뛰기




Volumn 2, Issue 3, 2005, Pages 431-447

Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics

Author keywords

Mass spectrometry; MS MS; Nano ESI; Nano LC; Nano LC MS; Nano LC MS MS; Nanoscale proteomics; Proteomics

Indexed keywords

BACTERIAL PROTEIN; NANOPARTICLE; PROTEOME;

EID: 20544441071     PISSN: 14789450     EISSN: None     Source Type: Journal    
DOI: 10.1586/14789450.2.3.431     Document Type: Review
Times cited : (36)

References (67)
  • 1
    • 0035387847 scopus 로고    scopus 로고
    • High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry
    • Shen Y, Tolic N, Zhao R et al. High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry. Anal. Chem. 73, 3011-3021 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 3011-3021
    • Shen, Y.1    Tolic, N.2    Zhao, R.3
  • 3
    • 0037102411 scopus 로고    scopus 로고
    • High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics
    • Shen Y, Zhao R, Berger SJ, Anderson GA, Rodriguez N, Smith RD. High-efficiency nanoscale liquid chromatography coupled on-line with mass spectrometry using nanoelectrospray ionization for proteomics. Anal. Chem. 74, 4235-4249 (2002). Describes the preparation of high-efficiency (peak capacity of approximately 1000), long 15-75-μm inner diameter (i.d.) packed capillaries, electrospray ionization (ESI) interfaces and resultant liquid chromatography (LC) mass spectrometry (MS) performance for proteomic analysis, including sensitivity, quantitation and reproducibility.
    • (2002) Anal. Chem. , vol.74 , pp. 4235-4249
    • Shen, Y.1    Zhao, R.2    Berger, S.J.3    Anderson, G.A.4    Rodriguez, N.5    Smith, R.D.6
  • 4
    • 1242316198 scopus 로고    scopus 로고
    • Ultra-high-efficiency strong cation exchange LC/RPLC/MS/MS for high dynamic range characterization of the human plasma proteome
    • Shen Y, Jacobs JM, Camp DG II et al. Ultra-high-efficiency strong cation exchange LC/RPLC/MS/MS for high dynamic range characterization of the human plasma proteome. Anal. Chem. 76, 1134-1144 (2004).
    • (2004) Anal. Chem. , vol.76 , pp. 1134-1144
    • Shen, Y.1    Jacobs, J.M.2    Camp II, D.G.3
  • 5
    • 0035870175 scopus 로고    scopus 로고
    • Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics
    • Shen Y, Zhao R, Belov ME et al. Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics. Anal. Chem. 73, 1766-1775 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 1766-1775
    • Shen, Y.1    Zhao, R.2    Belov, M.E.3
  • 6
    • 0242669999 scopus 로고    scopus 로고
    • High-efficiency on-line solid-phase extraction coupling to 15-150-μm-i.d. column liquid chromatography for proteomic analysis
    • Shen Y, Moore RJ, Zhao R et al. High-efficiency on-line solid-phase extraction coupling to 15-150-μm-i.d. column liquid chromatography for proteomic analysis. Anal. Chem. 75, 3596-3605 (2003). Discusses an online micro solid-phase extraction (SPE) sample-loading device that greatly improves the practicality of 15-75-μm i.d. packed capillary LC and documents its influence on LC separation efficiency and resulting capabilities for peptide detection and identification.
    • (2003) Anal. Chem. , vol.75 , pp. 3596-3605
    • Shen, Y.1    Moore, R.J.2    Zhao, R.3
  • 7
    • 0033485635 scopus 로고    scopus 로고
    • High-resolution capillary isoelectric focusing of complex protein mixture from lysates of microorganisms
    • Shen Y, Fan X, Veenstra TD, Fung EN, Smith RD. High-resolution capillary isoelectric focusing of complex protein mixture from lysates of microorganisms. Anal. Chem. 71, 5348-5353 (1999).
    • (1999) Anal. Chem. , vol.71 , pp. 5348-5353
    • Shen, Y.1    Fan, X.2    Veenstra, T.D.3    Fung, E.N.4    Smith, R.D.5
  • 8
    • 0034193643 scopus 로고    scopus 로고
    • High-efficiency capillary isoelectric focusing of peptides
    • Shen Y, Berger SJ, Anderson GA, Smith RD. High-efficiency capillary isoelectric focusing of peptides. Anal. Chem. 72, 2154-2159 (2000).
    • (2000) Anal. Chem. , vol.72 , pp. 2154-2159
    • Shen, Y.1    Berger, S.J.2    Anderson, G.A.3    Smith, R.D.4
  • 9
    • 0037999986 scopus 로고    scopus 로고
    • Capillary isoelectric focusing-based multidimensional concentration/separation platform for proteomic analysis
    • Chen J, Balgley BM, DeVoe DL, Lee CS. Capillary isoelectric focusing-based multidimensional concentration/separation platform for proteomic analysis. Anal. Chem. 75, 3145-3152 (2003).
    • (2003) Anal. Chem. , vol.75 , pp. 3145-3152
    • Chen, J.1    Balgley, B.M.2    DeVoe, D.L.3    Lee, C.S.4
  • 10
    • 21044443577 scopus 로고    scopus 로고
    • Automated 20 Kpsi RPLC-MS and MS/MS with Chromatographic peak capacities of 1,000-1,500 and capabilities in proteomics and metabolomics
    • Shen Y, Zhang R, Moore RJ et al. Automated 20 Kpsi RPLC-MS and MS/MS with Chromatographic peak capacities of 1,000-1,500 and capabilities in proteomics and metabolomics. Anal. Chem. 77, 3090-3100 (2005).
    • (2005) Anal. Chem. , vol.77 , pp. 3090-3100
    • Shen, Y.1    Zhang, R.2    Moore, R.J.3
  • 11
    • 4744358029 scopus 로고    scopus 로고
    • In-depth characterization of slurry packed capillary columns with 1.0-μ nonporous particles using reversed-phase isocratic ultrahigh-pressure liquid chromatography
    • Patel KD, Jerkovich AD, Link JC, Jorgenson JW. In-depth characterization of slurry packed capillary columns with 1.0-μ nonporous particles using reversed-phase isocratic ultrahigh-pressure liquid chromatography. Anal. Chem. 76, 5777-5786 (2004).
    • (2004) Anal. Chem. , vol.76 , pp. 5777-5786
    • Patel, K.D.1    Jerkovich, A.D.2    Link, J.C.3    Jorgenson, J.W.4
  • 12
    • 0000470652 scopus 로고    scopus 로고
    • Fast ultrahigh-pressure liquid chromatography: On-column UV and time-of-light mass spectrometric detection
    • Lippert JA, Xin B Wu N, Lee ML. Fast ultrahigh-pressure liquid chromatography: on-column UV and time-of-light mass spectrometric detection. J. Microcol. Sep. 11, 631-643 (1999).
    • (1999) J. Microcol. Sep. , vol.11 , pp. 631-643
    • Lippert, J.A.1    Xin, B.2    Wu, N.3    Lee, M.L.4
  • 13
    • 0002110673 scopus 로고
    • Mass spectrometry with ion sources operating at atmospheric pressure
    • Bruins AP. Mass spectrometry with ion sources operating at atmospheric pressure. Mass Spectrom. Rev. 10, 53-77 (1991).
    • (1991) Mass Spectrom. Rev. , vol.10 , pp. 53-77
    • Bruins, A.P.1
  • 14
    • 0027315599 scopus 로고
    • Use of small-diameter capillaries for increasing peptide and protein-detection sensitivity in capillary-electrophoresis mass-spectrometry
    • Wahl JH, Goodlett DR, Udseth HR, Smith RD. Use of small-diameter capillaries for increasing peptide and protein-detection sensitivity in capillary-electrophoresis mass-spectrometry. Electrophoresis 14, 448-457 (1993).
    • (1993) Electrophoresis , vol.14 , pp. 448-457
    • Wahl, J.H.1    Goodlett, D.R.2    Udseth, H.R.3    Smith, R.D.4
  • 15
    • 0029685702 scopus 로고    scopus 로고
    • Analytical properties of the nanoelectrospray ion source
    • Wilm M, Mann, M. Analytical properties of the nanoelectrospray ion source. Anal. Chem. 68, 1-8 (1996). Discusses the sensitivity dependence of ESI-MS on the solution flow rate and the electrospray emitter orifice dimensions.
    • (1996) Anal. Chem. , vol.68 , pp. 1-8
    • Wilm, M.1    Mann, M.2
  • 16
    • 1942439636 scopus 로고    scopus 로고
    • Ultrasensitive and quantitative analyses from combined separations-mass spectrometry for the characterization of proteomes
    • Smith RD, Shen Y, Tang K. Ultrasensitive and quantitative analyses from combined separations-mass spectrometry for the characterization of proteomes. Acc. Chem. Res. 37, 269-278 (2004). Discusses fundamental aspects of electrospray ionization relevant to LC/MS sensitivity, dynamic range and quantitative proteomics measurements.
    • (2004) Acc. Chem. Res. , vol.37 , pp. 269-278
    • Smith, R.D.1    Shen, Y.2    Tang, K.3
  • 17
    • 0032911015 scopus 로고    scopus 로고
    • Comparison of conventional, narrow-bore and capillary liquid chromatography/mass spectrometry for electrospray ionization mass spectrometry: Practical considerations
    • Abian J, Oosterkamp AJ, Gelpi E. Comparison of conventional, narrow-bore and capillary liquid chromatography/mass spectrometry for electrospray ionization mass spectrometry: practical considerations. J. Mass Spectrom. 34, 244-254 (1999).
    • (1999) J. Mass Spectrom. , vol.34 , pp. 244-254
    • Abian, J.1    Oosterkamp, A.J.2    Gelpi, E.3
  • 18
    • 0037487098 scopus 로고    scopus 로고
    • Effect of different solution flow rates on analyte ion signals in nano-ESI MS or: When does ESI turn into nano-ESI?
    • Schmidt A, Karas M, Dulcks T. Effect of different solution flow rates on analyte ion signals in nano-ESI MS or: when does ESI turn into nano-ESI? J. Am. Soc. Mass Spectrom. 14, 492-500 (2003). Discusses nano-ESI performance under conditions limiting analyte ionization suppression effects.
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , pp. 492-500
    • Schmidt, A.1    Karas, M.2    Dulcks, T.3
  • 20
    • 0001340533 scopus 로고
    • A study of micro-high-performance liquid chromatography I. Development of technique for miniaturization of high-performance liquid chromatography
    • Ishii D, Asai K, Hibi K, Jonokuchi T, Nagaya M. A study of micro-high-performance liquid chromatography I. Development of technique for miniaturization of high-performance liquid chromatography. J. Chromatogr. 144, 157-168 (1977).
    • (1977) J. Chromatogr. , vol.144 , pp. 157-168
    • Ishii, D.1    Asai, K.2    Hibi, K.3    Jonokuchi, T.4    Nagaya, M.5
  • 21
    • 0000903974 scopus 로고
    • Fused-silica narrow bore microparticle-packed-column high-performance liquid chromatography
    • Yang FJ. Fused-silica narrow bore microparticle-packed-column high-performance liquid chromatography. J. Chromatogr. 236, 265-277 (1982).
    • (1982) J. Chromatogr. , vol.236 , pp. 265-277
    • Yang, F.J.1
  • 22
    • 0024083278 scopus 로고
    • Separation efficiency of slurry-packed liquid chromatography microcolumns with very small inner diameters
    • Karlsson KE, Novotny M. Separation efficiency of slurry-packed liquid chromatography microcolumns with very small inner diameters. Anal. Chem. 60, 1662-1665 (1988).
    • (1988) Anal. Chem. , vol.60 , pp. 1662-1665
    • Karlsson, K.E.1    Novotny, M.2
  • 23
    • 33845184448 scopus 로고
    • Preparation and evaluation of packed capillary liquid chromatography columns with inner diameters from 20 to 50 μm
    • Kennedy RT, Jorgensen JW. Preparation and evaluation of packed capillary liquid chromatography columns with inner diameters from 20 to 50 μm. Anal. Chem. 61, 1128-1135 (1989). Discusses fabrication and performance of 20-μm i.d. packed capillaries for LC.
    • (1989) Anal. Chem. , vol.61 , pp. 1128-1135
    • Kennedy, R.T.1    Jorgensen, J.W.2
  • 24
    • 0001544494 scopus 로고    scopus 로고
    • Instrumental requirements for nanoscale liquid chromatography
    • Chervet JP, Ursem M, Salzmann JP. Instrumental requirements for nanoscale liquid chromatography. Anal. Chem. 68, 1507-1512 (1996).
    • (1996) Anal. Chem. , vol.68 , pp. 1507-1512
    • Chervet, J.P.1    Ursem, M.2    Salzmann, J.P.3
  • 25
    • 0030741349 scopus 로고    scopus 로고
    • Development of a nanoscale liquid chromatography/electrospray mass spectrometry methodology for the detection and identification of DNA adducts
    • Vanhoutte K, Van Dongen W, Hoes I et al. Development of a nanoscale liquid chromatography/electrospray mass spectrometry methodology for the detection and identification of DNA adducts. Anal. Chem. 69, 3161-3168 (1997).
    • (1997) Anal. Chem. , vol.69 , pp. 3161-3168
    • Vanhoutte, K.1    Van Dongen, W.2    Hoes, I.3
  • 26
    • 0034306616 scopus 로고    scopus 로고
    • Comparison between capillary and nano liquid chromatography-electrospray mass spectrometry for the analysis of minor DNA-melphalan adducts
    • Hose I, Van Dongen W, Lemière F, Esmans EL, Van Bockstaele D, Berneman ZN. Comparison between capillary and nano liquid chromatography- electrospray mass spectrometry for the analysis of minor DNA-melphalan adducts. J. Chromatogr. B 748, 197-212 (2000).
    • (2000) J. Chromatogr. B , vol.748 , pp. 197-212
    • Hose, I.1    Van Dongen, W.2    Lemière, F.3    Esmans, E.L.4    Van Bockstaele, D.5    Berneman, Z.N.6
  • 27
    • 0034665968 scopus 로고    scopus 로고
    • Subfemtomole MS and MS/MS peptide sequence analysis using nano-HPLC-ESI Fourier transform ion cyclotron resonance mass spectrometry
    • Martin SE, Shabanowitz J, Hunt DF, Marto JA. Subfemtomole MS and MS/MS peptide sequence analysis using nano-HPLC-ESI Fourier transform ion cyclotron resonance mass spectrometry. Anal. Chem. 72, 4266-4274 (2000).
    • (2000) Anal. Chem. , vol.72 , pp. 4266-4274
    • Martin, S.E.1    Shabanowitz, J.2    Hunt, D.F.3    Marto, J.A.4
  • 28
    • 0035870179 scopus 로고    scopus 로고
    • High-sensitivity Fourier transform ion cyclotron resonance mass spectrometry for biological analysis with nano-LC and microelectrospray ionization
    • Quenzer TL, Emmett MR, Hendrickson CL, Kelly PH, Marshall AG. High-sensitivity Fourier transform ion cyclotron resonance mass spectrometry for biological analysis with nano-LC and microelectrospray ionization. Anal. Chem. 73, 1721-1725 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 1721-1725
    • Quenzer, T.L.1    Emmett, M.R.2    Hendrickson, C.L.3    Kelly, P.H.4    Marshall, A.G.5
  • 29
    • 0347361594 scopus 로고    scopus 로고
    • Ultrasensitive proteomics using high-efficiency on-line micro-SPE-nanoLC-ESI MS and MS/MS
    • Shen Y, Toli N, Masselon C et al. Ultrasensitive proteomics using high-efficiency on-line micro-SPE-nanoLC-ESI MS and MS/MS. Anal. Chem. 76, 144-154 (2004). Describes the analysis of nanogram-sized proteomic samples using a 15-μm i.d. packed capillary LC column coupled online with micro-SPE for quantitative proteomic sample loading, enabling individual protein detection sensitivities at the low zeptomole for LC/MS and low attomole levels for LC/MS/MS.
    • (2004) Anal. Chem. , vol.76 , pp. 144-154
    • Shen, Y.1    Toli, N.2    Masselon, C.3
  • 30
    • 40449138174 scopus 로고    scopus 로고
    • Rapid quantitative measurements of proteomes by Fourier transform ion cyclotron resonance mass spectrometry
    • Smith RD, Paša-Tolic L, Lipton MS et al. Rapid quantitative measurements of proteomes by Fourier transform ion cyclotron resonance mass spectrometry. Electrophoresis 22, 1652-1668 (2001).
    • (2001) Electrophoresis , vol.22 , pp. 1652-1668
    • Smith, R.D.1    Paša-Tolic, L.2    Lipton, M.S.3
  • 31
    • 0036253914 scopus 로고    scopus 로고
    • An accurate mass tag strategy for quantitative and high-throughput proteome measurements
    • Smith RD, Anderson GA, Lipton MS et al. An accurate mass tag strategy for quantitative and high-throughput proteome measurements. Proteomics 2, 513-523 (2002).
    • (2002) Proteomics , vol.2 , pp. 513-523
    • Smith, R.D.1    Anderson, G.A.2    Lipton, M.S.3
  • 32
    • 0033051101 scopus 로고    scopus 로고
    • Direct analysis of protein complexes using mass spectrometry
    • Link AJ, Eng J, Schieltz DM et al. Direct analysis of protein complexes using mass spectrometry. Nature Biotechnol. 17, 676-682 (1999).
    • (1999) Nature Biotechnol. , vol.17 , pp. 676-682
    • Link, A.J.1    Eng, J.2    Schieltz, D.M.3
  • 33
    • 0035106351 scopus 로고    scopus 로고
    • Large-scale analysis of the yeast proteome by multidimensional protein identification technology
    • Washburn MP, Wolters D, Yates JR. Large-scale analysis of the yeast proteome by multidimensional protein identification technology. Nature Biotechnol. 19, 242-247 (2001). Discusses approaches for shotgun LC/MS/MS bottom-up proteomics and peptide identification methodologies.
    • (2001) Nature Biotechnol. , vol.19 , pp. 242-247
    • Washburn, M.P.1    Wolters, D.2    Yates, J.R.3
  • 34
    • 0033565981 scopus 로고    scopus 로고
    • High-mass-measurement accuracy and 100% sequence coverage of enzymatically digested bovine serum albumin from an ESI-FTICR mass spectrum
    • Bruce JE, Anderson GA, Wen J, Harkewicz R, Smith RD. High-mass- measurement accuracy and 100% sequence coverage of enzymatically digested bovine serum albumin from an ESI-FTICR mass spectrum. Anal. Chem. 71, 2595-2599 (1999).
    • (1999) Anal. Chem. , vol.71 , pp. 2595-2599
    • Bruce, J.E.1    Anderson, G.A.2    Wen, J.3    Harkewicz, R.4    Smith, R.D.5
  • 35
    • 0042887140 scopus 로고    scopus 로고
    • Proteome analysis using accurate mass and elution time peptide tags with capillary LC time-of-flight mass spectrometry
    • Strittmatter EF, Ferguson PL, Tang K, Smith RD. Proteome analysis using accurate mass and elution time peptide tags with capillary LC time-of-flight mass spectrometry. J. Am. Soc. Mass Spectrom. 14, 980-991 (2003).
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , pp. 980-991
    • Strittmatter, E.F.1    Ferguson, P.L.2    Tang, K.3    Smith, R.D.4
  • 36
    • 0036099050 scopus 로고    scopus 로고
    • ESI-FTICR mass spectrometry employing data-dependent external ion selection and accumulation
    • Harkewicz R, Belov ME, Anderson GA et al. ESI-FTICR mass spectrometry employing data-dependent external ion selection and accumulation. J. Am. Soc. Mass Spectrom. 13, 144-154 (2002).
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , pp. 144-154
    • Harkewicz, R.1    Belov, M.E.2    Anderson, G.A.3
  • 37
    • 0018990802 scopus 로고
    • Prediction of peptide retention times in high-pressure liquid chromatography on the basis of amino acid composition
    • Meek JL. Prediction of peptide retention times in high-pressure liquid chromatography on the basis of amino acid composition. Proc. Natl Acad. Sci. USA 77, 1632-1636 (1980).
    • (1980) Proc. Natl. Acad. Sci. USA , vol.77 , pp. 1632-1636
    • Meek, J.L.1
  • 38
    • 0034650737 scopus 로고    scopus 로고
    • One-dimensional protein analysis of an HT29 human colon adenocarcinoma cell
    • Zhang Z, Krylov S, Arriaga EA, Polakowski R, Dovichi NJ. One-dimensional protein analysis of an HT29 human colon adenocarcinoma cell. Anal. Chem. 72, 318-322 (2000).
    • (2000) Anal. Chem. , vol.72 , pp. 318-322
    • Zhang, Z.1    Krylov, S.2    Arriaga, E.A.3    Polakowski, R.4    Dovichi, N.J.5
  • 40
    • 0033535961 scopus 로고    scopus 로고
    • Accurate quantitation of protein expression and site-specific phosphorylation
    • Oda Y, Huang K, Cross FR, Cowburn D, Chait B. Accurate quantitation of protein expression and site-specific phosphorylation. Proc. Natl Acad. Sci. USA 96, 6591-6596 (1999).
    • (1999) Proc. Natl. Acad. Sci. USA , vol.96 , pp. 6591-6596
    • Oda, Y.1    Huang, K.2    Cross, F.R.3    Cowburn, D.4    Chait, B.5
  • 41
    • 0034282758 scopus 로고    scopus 로고
    • Peptide electroextraction for direct coupling of in-gel digests with capillary LC-MS/MS for protein identification and sequencing
    • Timperman AT, Aebersold R. Peptide electroextraction for direct coupling of in-gel digests with capillary LC-MS/MS for protein identification and sequencing. Anal. Chem. 72, 4115-4121 (2000).
    • (2000) Anal. Chem. , vol.72 , pp. 4115-4121
    • Timperman, A.T.1    Aebersold, R.2
  • 42
    • 0032159387 scopus 로고    scopus 로고
    • Method to compare collision-induced dissociation spectra of peptides: Potential for library searching and subtractive analysis
    • Yates JR III, Morgan SF, Gatlin CL, Griffin PR, Eng JK. Method to compare collision-induced dissociation spectra of peptides: potential for library searching and subtractive analysis. Anal. Chem. 70, 3557-3565 (1998).
    • (1998) Anal. Chem. , vol.70 , pp. 3557-3565
    • Yates III, J.R.1    Morgan, S.F.2    Gatlin, C.L.3    Griffin, P.R.4    Eng, J.K.5
  • 43
    • 0032969777 scopus 로고    scopus 로고
    • High-sensitivity analysis and sequencing of peptides and proteins by quadrupole ion trap mass spectrometry
    • Marina A, Garcia MA, Albar JP et al. High-sensitivity analysis and sequencing of peptides and proteins by quadrupole ion trap mass spectrometry. J. Mass Spectrom. 33, 17-27 (1999).
    • (1999) J. Mass Spectrom. , vol.33 , pp. 17-27
    • Marina, A.1    Garcia, M.A.2    Albar, J.P.3
  • 44
    • 0034652301 scopus 로고    scopus 로고
    • Automated identification of aminio acid sequence variations in proteins by HPLC/microspray tandem mass spectrometry
    • Gatlin CL, Eng JK, Cross ST, Detter JC, Yates JR. Automated identification of aminio acid sequence variations in proteins by HPLC/microspray tandem mass spectrometry. Anal. Chem. 72, 757-763 (2000).
    • (2000) Anal. Chem. , vol.72 , pp. 757-763
    • Gatlin, C.L.1    Eng, J.K.2    Cross, S.T.3    Detter, J.C.4    Yates, J.R.5
  • 45
    • 0000217562 scopus 로고
    • Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
    • Wilm M, Mann M. Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last? Int. J. Mass Spectrom. Ion Processes 136, 167-180 (1994).
    • (1994) Int. J. Mass Spectrom. Ion Processes , vol.136 , pp. 167-180
    • Wilm, M.1    Mann, M.2
  • 46
    • 0028304337 scopus 로고
    • Identification of a peptide recognized by 5 melanoma-specific human cytotoxic T-cell lines
    • Cox AL, Skipper J, Chen Y et al. Identification of a peptide recognized by 5 melanoma-specific human cytotoxic T-cell lines. Science 264, 716-719 (1994).
    • (1994) Science , vol.264 , pp. 716-719
    • Cox, A.L.1    Skipper, J.2    Chen, Y.3
  • 47
    • 0029092140 scopus 로고
    • Human H-Y - A male-specific histocompatibility antigen derived from the SMCY protein
    • Wang W, Meadows LR, den Haan JM et al. Human H-Y - a male-specific histocompatibility antigen derived from the SMCY protein. Science 269, 1588-1590 (1995).
    • (1995) Science , vol.269 , pp. 1588-1590
    • Wang, W.1    Meadows, L.R.2    Den Haan, J.M.3
  • 48
    • 0029927505 scopus 로고    scopus 로고
    • Mass spectrometric sequencing of proteins from silver-stained polyacrylamide gel
    • Shevchenko A, Wilm M, Vorm O, Mann M. Mass spectrometric sequencing of proteins from silver-stained polyacrylamide gel. Anal. Chem. 68, 850-858 (1996).
    • (1996) Anal. Chem. , vol.68 , pp. 850-858
    • Shevchenko, A.1    Wilm, M.2    Vorm, O.3    Mann, M.4
  • 49
    • 0029907530 scopus 로고    scopus 로고
    • Protein identification by solid-phase microextraction-capillary zone electrophoresis-microelectrospray-tandem mass spectrometry
    • Figeys D, Ducret A, Yates JR III, Aebersold R. Protein identification by solid-phase microextraction-capillary zone electrophoresis-microelectrospray- tandem mass spectrometry. Nature Biotechnol. 14, 1579-1583 (1996).
    • (1996) Nature Biotechnol. , vol.14 , pp. 1579-1583
    • Figeys, D.1    Ducret, A.2    Yates III, J.R.3    Aebersold, R.4
  • 50
    • 0030796836 scopus 로고    scopus 로고
    • A novel geometry mass spectrometry, the Q-TOF, for low-femtomole/ attomole-range biopolymer sequencing
    • Morris HR, Paxton T, Panico M, McDowell R, Dell A. A novel geometry mass spectrometry, the Q-TOF, for low-femtomole/attomole-range biopolymer sequencing. J. Protein Chem. 16, 469-479 (1997).
    • (1997) J. Protein Chem. , vol.16 , pp. 469-479
    • Morris, H.R.1    Paxton, T.2    Panico, M.3    McDowell, R.4    Dell, A.5
  • 51
    • 0033967708 scopus 로고    scopus 로고
    • Mass spectrometric approaches for the characterization of proteins on a hybrid quadrupole time-of-flight (Q-TOF) mass spectrometer
    • Kristensen DB, Imamura K, Miyamoto Y, Yoshizato K. Mass spectrometric approaches for the characterization of proteins on a hybrid quadrupole time-of-flight (Q-TOF) mass spectrometer. Electrophoresis 21, 430-439 (2000).
    • (2000) Electrophoresis , vol.21 , pp. 430-439
    • Kristensen, D.B.1    Imamura, K.2    Miyamoto, Y.3    Yoshizato, K.4
  • 52
    • 0035282172 scopus 로고    scopus 로고
    • Quantitative proteomics analysis using a MALDI quadrupole time-of-flight mass spectrometer
    • Graiffin TJ, Gygi SP, Rist B et al. Quantitative proteomics analysis using a MALDI quadrupole time-of-flight mass spectrometer. Anal. Chem. 73, 978-986 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 978-986
    • Graiffin, T.J.1    Gygi, S.P.2    Rist, B.3
  • 53
    • 0025409484 scopus 로고
    • Hadamard transform measurement of tandem Fourier-transform mass spectra
    • Williams ER, Loh SY, McLafferty FW, Cody RB. Hadamard transform measurement of tandem Fourier-transform mass spectra. Anal. Chem. 62, 698-703 (1990).
    • (1990) Anal. Chem. , vol.62 , pp. 698-703
    • Williams, E.R.1    Loh, S.Y.2    McLafferty, F.W.3    Cody, R.B.4
  • 54
    • 0000159218 scopus 로고
    • Two-dimensional Fourier transform ion cyclotron resonance mass spectrometry/mass spectrometry with stored-waveform ion radius modulation
    • Ross CW, Guan SH, Grosshans PB, Ricca TL, Marshall AG. Two-dimensional Fourier transform ion cyclotron resonance mass spectrometry/mass spectrometry with stored-waveform ion radius modulation. J. Am. Chem. Soc. 115, 7854-7861 (1993).
    • (1993) J. Am. Chem. Soc. , vol.115 , pp. 7854-7861
    • Ross, C.W.1    Guan, S.H.2    Grosshans, P.B.3    Ricca, T.L.4    Marshall, A.G.5
  • 55
    • 0034655385 scopus 로고    scopus 로고
    • Accurate mass multiplexed tandem mass spectrometry for high-throughput polypeptide identification from mixtures
    • Masselon C, Anderson GA, Harkewicz R, Bruce JE, Paša-Tolic L, Smith RD. Accurate mass multiplexed tandem mass spectrometry for high-throughput polypeptide identification from mixtures. Anal. Chem. 72, 1918-1924 (2000).
    • (2000) Anal. Chem. , vol.72 , pp. 1918-1924
    • Masselon, C.1    Anderson, G.A.2    Harkewicz, R.3    Bruce, J.E.4    Paša-Tolic, L.5    Smith, R.D.6
  • 56
    • 20244381257 scopus 로고    scopus 로고
    • High-throughput peptide identification from protein digests using data-dependent multiplexed tandem FTICR mass spectrometry coupled with capillary liquid chromatography
    • Li L, Masseion CD, Anderson GA et al. High-throughput peptide identification from protein digests using data-dependent multiplexed tandem FTICR mass spectrometry coupled with capillary liquid chromatography. Anal. Chem. 73, 3312-3322 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 3312-3322
    • Li, L.1    Masseion, C.D.2    Anderson, G.A.3
  • 57
    • 0035416833 scopus 로고    scopus 로고
    • High-sensitivity electron capture dissociation tandem FTICR mass spectrometry of microelectrosprayed peptides
    • Hikansson K, Emmett MR, Hendrickson CL, Marshall AG. High-sensitivity electron capture dissociation tandem FTICR mass spectrometry of microelectrosprayed peptides. Anal. Chem. 73, 3605-3610 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 3605-3610
    • Hikansson, K.1    Emmett, M.R.2    Hendrickson, C.L.3    Marshall, A.G.4
  • 58
    • 0035497747 scopus 로고    scopus 로고
    • 2 at the attomole level for monitoring and discovering endogenous peptides in microdialysis samples collected in vivo
    • 2 at the attomole level for monitoring and discovering endogenous peptides in microdialysis samples collected in vivo. Anal. Chem. 73, 5005-5014 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 5005-5014
    • Haskins, W.E.1    Wang, Z.2    Watson, C.J.3
  • 59
    • 0142072517 scopus 로고    scopus 로고
    • Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-μm-i.d. polystyrene-divinylbenzene monolithic capillary columns
    • Ivanov AR, Zhang L, Karger BL. Low-attomole electrospray ionization MS and MS/MS analysis of protein tryptic digests using 20-μm-i.d. polystyrene-divinylbenzene monolithic capillary columns. Anal. Chem. 75, 5306-5316 (2003).
    • (2003) Anal. Chem. , vol.75 , pp. 5306-5316
    • Ivanov, A.R.1    Zhang, L.2    Karger, B.L.3
  • 60
    • 0035500231 scopus 로고    scopus 로고
    • Dynamic range expansion applied to mass spectrometry based on data-dependant selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization
    • Belov ME, Anderson GA, Angel NH et al. Dynamic range expansion applied to mass spectrometry based on data-dependant selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization. Anal. Chem. 73, 5052-5060 (2001).
    • (2001) Anal. Chem. , vol.73 , pp. 5052-5060
    • Belov, M.E.1    Anderson, G.A.2    Angel, N.H.3
  • 61
    • 0036675232 scopus 로고    scopus 로고
    • Increased proteome coverage for quantitative peptide abundance measurements based upon high performance separations and DREAMS FTICR mass spectrometry
    • Paša-Tolic L, Harkewicz R, Anderson GA et al. Increased proteome coverage for quantitative peptide abundance measurements based upon high performance separations and DREAMS FTICR mass spectrometry. J. Am. Soc. Mass Spectrom. 13, 954-963 (2002).
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , pp. 954-963
    • Paša-Tolic, L.1    Harkewicz, R.2    Anderson, G.A.3
  • 62
    • 0030830309 scopus 로고    scopus 로고
    • The cellular basis of tumor progression
    • Heppner GH, Miller FR. The cellular basis of tumor progression. Int. Rev. Cytol. 177, 1-56 (1998).
    • (1998) Int. Rev. Cytol. , vol.177 , pp. 1-56
    • Heppner, G.H.1    Miller, F.R.2
  • 65
    • 0041975811 scopus 로고    scopus 로고
    • Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-Fourier transform ion cyclotron resonance
    • Belov ME, Zhang R, Strittmatter EF, Prior DC, Tang K, Smith RD. Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-Fourier transform ion cyclotron resonance. Anal. Chem. 75, 4195-4205 (2003).
    • (2003) Anal. Chem. , vol.75 , pp. 4195-4205
    • Belov, M.E.1    Zhang, R.2    Strittmatter, E.F.3    Prior, D.C.4    Tang, K.5    Smith, R.D.6
  • 66
    • 18844425931 scopus 로고    scopus 로고
    • High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces
    • Tang K, Shvartsburg AA, Lee HN et al. High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces. Anal Chem. 77, 3330-3339 (2005).
    • (2005) Anal Chem. , vol.77 , pp. 3330-3339
    • Tang, K.1    Shvartsburg, A.A.2    Lee, H.N.3
  • 67
    • 9344248022 scopus 로고    scopus 로고
    • Accurate molecular weight determination of plasmid DNA using mass spectrometry
    • Cheng X, Camp II DG, Wu Q et al. Accurate molecular weight determination of plasmid DNA using mass spectrometry. Nucleic Acid Res. 24, 2183-2189 (1996).
    • (1996) Nucleic Acid Res. , vol.24 , pp. 2183-2189
    • Cheng, X.1    Camp II, D.G.2    Wu, Q.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.