메뉴 건너뛰기




Volumn 41, Issue 7, 1996, Pages 601-606

Incidence of ventilator-associated pneumonia (VAP) with 14-day circuit change in a subacute environment

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL VENTILATION; BACTERIAL PNEUMONIA; FEMALE; HOSPITAL INFECTION; HUMAN; MAJOR CLINICAL STUDY; MALE; TRACHEOSTOMY; VENTILATOR;

EID: 0030016983     PISSN: 00989142     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (39)
  • 1
    • 0028967903 scopus 로고
    • Diagnosis and differential diagnosis of ventilator-associated pneumonia
    • Meduri GU. Diagnosis and differential diagnosis of ventilator-associated pneumonia. Clin Chest Med 1995;16(1):61-93.
    • (1995) Clin Chest Med , vol.16 , Issue.1 , pp. 61-93
    • Meduri, G.U.1
  • 2
    • 0024559819 scopus 로고
    • Nosocomial pneumonia in patients receiving continuous mechanical ventilation. Prospective analysis of 52 episodes with use of a protected brush and quantitative culture techniques
    • Fagon JY, Chastre J, Domart Y, Trouillet JL, Pierre J, Darne C, Gibert C. Nosocomial pneumonia in patients receiving continuous mechanical ventilation. Prospective analysis of 52 episodes with use of a protected brush and quantitative culture techniques. Am Rev Respir Dis 1989;139(4):877-884.
    • (1989) Am Rev Respir Dis , vol.139 , Issue.4 , pp. 877-884
    • Fagon, J.Y.1    Chastre, J.2    Domart, Y.3    Trouillet, J.L.4    Pierre, J.5    Darne, C.6    Gibert, C.7
  • 3
    • 0027382380 scopus 로고
    • Ventilator-associated pneumonia: A multivariate analysis
    • Kollef MH. Ventilator-associated pneumonia: a multivariate analysis. JAMA 1993;270(16):1965-1970
    • (1993) JAMA , vol.270 , Issue.16 , pp. 1965-1970
    • Kollef, M.H.1
  • 4
    • 0025102886 scopus 로고
    • Incidence, risk, and prognosis factors of nosocomial pneumonia in mechanically ventilated patients
    • Torres A, Aznar R, Gatell JM, Jimenez P, Gonzalez J, Ferrer A, et al. Incidence, risk, and prognosis factors of nosocomial pneumonia in mechanically ventilated patients. Am Rev Respir Dis 1990;142(3): 523-528
    • (1990) Am Rev Respir Dis , vol.142 , Issue.3 , pp. 523-528
    • Torres, A.1    Aznar, R.2    Gatell, J.M.3    Jimenez, P.4    Gonzalez, J.5    Ferrer, A.6
  • 7
    • 0029090682 scopus 로고
    • Mechanical ventilation with and without 7-day circuit changes. A randomized controlled trial
    • Kollef MH, Shapiro SD, Fraser VJ, Silver P, Murphy DM, Trovillion E, et al. Mechanical ventilation with and without 7-day circuit changes. A randomized controlled trial. Ann Intern Med 1995;123 (3):168-174.
    • (1995) Ann Intern Med , vol.123 , Issue.3 , pp. 168-174
    • Kollef, M.H.1    Shapiro, S.D.2    Fraser, V.J.3    Silver, P.4    Murphy, D.M.5    Trovillion, E.6
  • 9
    • 0028919771 scopus 로고
    • Epidemiology of nosocomial pneumonia in intensive care units
    • George DL. Epidemiology of nosocomial pneumonia in intensive care units. Clin Chest Med 1995;16(1):29-44.
    • (1995) Clin Chest Med , vol.16 , Issue.1 , pp. 29-44
    • George, D.L.1
  • 10
    • 0026062881 scopus 로고
    • Major trends in the microbial etiology of nosocomial infection
    • Schaberg DR, Culver DH, Gaynes RP. Major trends in the microbial etiology of nosocomial infection. Am J Med 1991;91(3B, Suppl):72S-75S.
    • (1991) Am J Med , vol.91 , Issue.3 B AND SUPPL.
    • Schaberg, D.R.1    Culver, D.H.2    Gaynes, R.P.3
  • 11
    • 0022652076 scopus 로고
    • Alteration of normal gastric flora in critical care patients receiving antacid and cimetidine therapy
    • Donowitz LG, Page MC, Mileur BL, Guenthner SH. Alteration of normal gastric flora in critical care patients receiving antacid and cimetidine therapy. Infect Control 1986;7(1):23-26.
    • (1986) Infect Control , vol.7 , Issue.1 , pp. 23-26
    • Donowitz, L.G.1    Page, M.C.2    Mileur, B.L.3    Guenthner, S.H.4
  • 12
    • 0026606379 scopus 로고
    • Pulmonary aspiration of gastric contents in patients receiving mechanical ventilation: The effect of body position
    • Torres A, Serra-Battles J, Ros E, Piera C, Puig de la Bellacasa J, Cobos A, et al. Pulmonary aspiration of gastric contents in patients receiving mechanical ventilation: the effect of body position. Ann Intern Med 1992;116(7):540-543.
    • (1992) Ann Intern Med , vol.116 , Issue.7 , pp. 540-543
    • Torres, A.1    Serra-Battles, J.2    Ros, E.3    Piera, C.4    Puig De La Bellacasa, J.5    Cobos, A.6
  • 13
    • 0027685789 scopus 로고
    • Nosocomial outbreak of Pseudomonas cepacia associated with contamination of reusable electronic ventilator temperature probes
    • Weems JJ Jr. Nosocomial outbreak of Pseudomonas cepacia associated with contamination of reusable electronic ventilator temperature probes. Infect Control Hosp Epidemiol 1993;14(10):583-586.
    • (1993) Infect Control Hosp Epidemiol , vol.14 , Issue.10 , pp. 583-586
    • Weems Jr., J.J.1
  • 14
    • 0021275019 scopus 로고
    • Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia?
    • Craven DE, Goularte TA, Make BJ. Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia? Am Rev Respir Dis 1984;129(4):625-628.
    • (1984) Am Rev Respir Dis , vol.129 , Issue.4 , pp. 625-628
    • Craven, D.E.1    Goularte, T.A.2    Make, B.J.3
  • 15
    • 0342598856 scopus 로고
    • The potential role of inhalation therapy equipment in nosocomial pulmonary infection
    • Reinarz JA, Pierce AK, Mays BB, Sanford JP. The potential role of inhalation therapy equipment in nosocomial pulmonary infection. J Clin Invest 1965;44:831-839.
    • (1965) J Clin Invest , vol.44 , pp. 831-839
    • Reinarz, J.A.1    Pierce, A.K.2    Mays, B.B.3    Sanford, J.P.4
  • 16
    • 0014933130 scopus 로고
    • Long-term evaluation of decontamination of inhalation-therapy equipment and the occurrence of necrotizing pneumonia
    • Pierce AK, Sanford JP, Thomas GD, Leonard JS. Long-term evaluation of decontamination of inhalation-therapy equipment and the occurrence of necrotizing pneumonia. N Engl J Med 1970;282(10): 528-531.
    • (1970) N Engl J Med , vol.282 , Issue.10 , pp. 528-531
    • Pierce, A.K.1    Sanford, J.P.2    Thomas, G.D.3    Leonard, J.S.4
  • 17
    • 0013897384 scopus 로고
    • Nebulization equipment A potential source of infection in Gram-negative pneumonias
    • Edmondson EB, Reinarz JA, Pierce AK, Sanford JP. Nebulization equipment A potential source of infection in Gram-negative pneumonias. Am J Dis Child 1966;111(4):357-360.
    • (1966) Am J Dis Child , vol.111 , Issue.4 , pp. 357-360
    • Edmondson, E.B.1    Reinarz, J.A.2    Pierce, A.K.3    Sanford, J.P.4
  • 18
    • 0018161409 scopus 로고
    • The relationship between frequency of ventilator circuit changes and infectious hazard
    • Lareau SC, Ryan KJ, Diener CF. The relationship between frequency of ventilator circuit changes and infectious hazard. Am Rev Respir Dis 1978;118(3):493-496.
    • (1978) Am Rev Respir Dis , vol.118 , Issue.3 , pp. 493-496
    • Lareau, S.C.1    Ryan, K.J.2    Diener, C.F.3
  • 20
    • 0025980586 scopus 로고
    • Prospective study of nosocomial and of patient circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change
    • Dreyfuss D, Djedaini K, Weber P, Brun P, Lanore JJ, Rahmani J, et al. Prospective study of nosocomial and of patient circuit colonization during mechanical ventilation with circuit changes every 48 hours versus no change. Am Rev Respir Dis 1991;143(4, Part 1):738-743.
    • (1991) Am Rev Respir Dis , vol.143 , Issue.4 PART 1 , pp. 738-743
    • Dreyfuss, D.1    Djedaini, K.2    Weber, P.3    Brun, P.4    Lanore, J.J.5    Rahmani, J.6
  • 21
    • 0028943271 scopus 로고
    • Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates
    • Hess D, Burns E, Romagnoli D, Kacmarek RM Weekly ventilator circuit changes. A strategy to reduce costs without affecting pneumonia rates. Anesthesiology 1995;82(4):903-911.
    • (1995) Anesthesiology , vol.82 , Issue.4 , pp. 903-911
    • Hess, D.1    Burns, E.2    Romagnoli, D.3    Kacmarek, R.M.4
  • 23
    • 0342598851 scopus 로고
    • Reduction of ventilator-associated pneumonia with seven day circuit changes
    • Krause S, Fisher M, Fink J. Reduction of ventilator-associated pneumonia with seven day circuit changes (abstract). Respir Care 1994; 39(11):1108.
    • (1994) Respir Care , vol.39 , Issue.11 , pp. 1108
    • Krause, S.1    Fisher, M.2    Fink, J.3
  • 24
    • 0343904625 scopus 로고
    • The impact of changing ventilator circuits at 72 hours versus 7 days on ventilator-associated pneumonia
    • Orens D, Stoller JK. The impact of changing ventilator circuits at 72 hours versus 7 days on ventilator-associated pneumonia (abstract) Respir Care 1994;39(11):1108.
    • (1994) Respir Care , vol.39 , Issue.11 , pp. 1108
    • Orens, D.1    Stoller, J.K.2
  • 25
    • 0343468849 scopus 로고
    • A two-year experience with ten-day ventilator circuit change
    • Tyra JA, Norwood JA. A two-year experience with ten-day ventilator circuit change (abstract). Respir Care 1994;39(11):1107.
    • (1994) Respir Care , vol.39 , Issue.11 , pp. 1107
    • Tyra, J.A.1    Norwood, J.A.2
  • 26
    • 9344263060 scopus 로고
    • Extending ventilator circuit change interval beyond two days reduces likelihood of ventilator associated pneumonia (VAP)
    • Fink, J, Krause S, Barrett MS. Extending ventilator circuit change interval beyond two days reduces likelihood of ventilator associated pneumonia (VAP) (abstract). Respir Care 1995;40(11):1200.
    • (1995) Respir Care , vol.40 , Issue.11 , pp. 1200
    • Fink, J.1    Krause, S.2    Barrett, M.S.3
  • 27
    • 0028580543 scopus 로고
    • Guideline for prevention of nosocomial pneumonia
    • Hospital Infection Control Practices Advisory Committee, Centers for Disease Control & Prevention. Guideline for prevention of nosocomial pneumonia. Respir Care 1994;39(12):1191-1236.
    • (1994) Respir Care , vol.39 , Issue.12 , pp. 1191-1236
  • 28
    • 0027125894 scopus 로고
    • Public health focus: Surveillance, prevention, and control of nosocomial infections
    • Public health focus: surveillance, prevention, and control of nosocomial infections. MMWR Morb Mortal Wkly Rep 1992;41(42): 783-787.
    • (1992) MMWR Morb Mortal Wkly Rep , vol.41 , Issue.42 , pp. 783-787
  • 29
    • 0023107007 scopus 로고
    • The financial incentive for hospitals to prevent nosocomial infections under the prospective payment system. An empirical determination from a nationally representative sample
    • Haley RW, White JW, Culver DH, Hughes JM. The financial incentive for hospitals to prevent nosocomial infections under the prospective payment system. An empirical determination from a nationally representative sample. JAMA 1987;257(12):1611-1614.
    • (1987) JAMA , vol.257 , Issue.12 , pp. 1611-1614
    • Haley, R.W.1    White, J.W.2    Culver, D.H.3    Hughes, J.M.4
  • 30
    • 0025878294 scopus 로고
    • Nosocomial pneumonia in Medicare patients. Hospital cost and reimbursement patterns under the prospective payment system
    • Boyce JM, Potter-Bynoe G, Dziobek L, Solomon SL. Nosocomial pneumonia in Medicare patients. Hospital cost and reimbursement patterns under the prospective payment system. Arch Intern Med 1991,151(6):1109-1114.
    • (1991) Arch Intern Med , vol.151 , Issue.6 , pp. 1109-1114
    • Boyce, J.M.1    Potter-Bynoe, G.2    Dziobek, L.3    Solomon, S.L.4
  • 31
    • 0028140259 scopus 로고
    • Weaning from prolonged mechanical ventilation: The experience at a regional weaning center
    • Scheinhorn DJ, Artinian BM, Catlin JL. Weaning from prolonged mechanical ventilation: the experience at a regional weaning center. Chest 1994;105(2):534-539.
    • (1994) Chest , vol.105 , Issue.2 , pp. 534-539
    • Scheinhorn, D.J.1    Artinian, B.M.2    Catlin, J.L.3
  • 32
    • 0026247876 scopus 로고
    • Demographics of long-term ventilator-dependent patients outside the intensive care units
    • Cordasco EM Jr, Sivak ED, Perez-Trepichio A. Demographics of long-term ventilator-dependent patients outside the intensive care units. Cleve Clin J Med 1991;58(6):505-509.
    • (1991) Cleve Clin J Med , vol.58 , Issue.6 , pp. 505-509
    • Cordasco Jr., E.M.1    Sivak, E.D.2    Perez-Trepichio, A.3
  • 33
    • 9344257452 scopus 로고
    • Ventilator-associated pneumonia (VAP) in a subacute setting with 7-day circuit change
    • Thompson R, Piotrowski A, Vukelic G. Ventilator-associated pneumonia (VAP) in a subacute setting with 7-day circuit change (abstract). Respir Care 1995;40(11):1200.
    • (1995) Respir Care , vol.40 , Issue.11 , pp. 1200
    • Thompson, R.1    Piotrowski, A.2    Vukelic, G.3
  • 34
    • 9344222934 scopus 로고
    • Movement of bacterial contaminants is reduced in heated ventilator circuits
    • Orec R, Richards G, Cornere B, Dove B, Morris A. Movement of bacterial contaminants is reduced in heated ventilator circuits (abstract). Respir Care 1995;40(11):1201.
    • (1995) Respir Care , vol.40 , Issue.11 , pp. 1201
    • Orec, R.1    Richards, G.2    Cornere, B.3    Dove, B.4    Morris, A.5
  • 35
    • 0024364792 scopus 로고
    • Comparison of tracheal aspirates and protected brush catheter specimens for identifying pathogenic bacteria in mechanically ventilated patients
    • Lambert RS, Vereen LE, George RB. Comparison of tracheal aspirates and protected brush catheter specimens for identifying pathogenic bacteria in mechanically ventilated patients. Am J Med Sci 1989; 297(6):377-382.
    • (1989) Am J Med Sci , vol.297 , Issue.6 , pp. 377-382
    • Lambert, R.S.1    Vereen, L.E.2    George, R.B.3
  • 36
    • 0023813273 scopus 로고
    • Detection of nosocomial lung infection in ventilated patients. Use of protected specimen brush and quantitative culture techniques in 147 patients
    • Fagon JY, Chastre J, Hance AJ, Guiguet M, Trouillet JL, Domart Y, Pierre J, Gibert C. Detection of nosocomial lung infection in ventilated patients. Use of protected specimen brush and quantitative culture techniques in 147 patients. Am Rev Respir Dis 1988;138(1): 110-116.
    • (1988) Am Rev Respir Dis , vol.138 , Issue.1 , pp. 110-116
    • Fagon, J.Y.1    Chastre, J.2    Hance, A.J.3    Guiguet, M.4    Trouillet, J.L.5    Domart, Y.6    Pierre, J.7    Gibert, C.8
  • 38
    • 0002917982 scopus 로고
    • Pneumonia in the ventilator-dependent patient
    • Tobin MJ (editor) New York: McGraw-Hill
    • Chastre J, Fagon JY. Pneumonia in the ventilator-dependent patient. In: Tobin MJ (editor) Principles and practice of mechanical ventilation. New York: McGraw-Hill 1994:857-890.
    • (1994) Principles and Practice of Mechanical Ventilation , pp. 857-890
    • Chastre, J.1    Fagon, J.Y.2
  • 39
    • 9344245308 scopus 로고
    • Limited-service hospitals find a market
    • July 23
    • Tomsho R. Limited-service hospitals find a market. Wall Street Journal, July 23, 1992;B1,8.
    • (1992) Wall Street Journal
    • Tomsho, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.