메뉴 건너뛰기




Volumn 77, Issue SPEC. ISS. 2, 2004, Pages

Analysis of dynamic contrast enhanced MRI

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BRAIN BLOOD FLOW; BRAIN PERFUSION; CALCULATION; CONTRAST ENHANCEMENT; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; MATHEMATICAL COMPUTING; NUCLEAR MAGNETIC RESONANCE IMAGING; REPRODUCIBILITY; SIGNAL NOISE RATIO;

EID: 14044276970     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr/16652509     Document Type: Article
Times cited : (73)

References (50)
  • 2
    • 0033496776 scopus 로고    scopus 로고
    • Measuring cerebral blood flow using magnetic resonance imaging techniques
    • Calamante F, et al. Measuring cerebral blood flow using magnetic resonance imaging techniques. J Cereb Blood Flow Metab 1999;19:701-35.
    • (1999) J. Cereb. Blood Flow Metab. , vol.19 , pp. 701-735
    • Calamante, F.1
  • 3
    • 0033509609 scopus 로고    scopus 로고
    • Modelling cerebral blood flow and flow heterogeneity from magnetic resonance residue data
    • Ostergaard L, et al. Modelling cerebral blood flow and flow heterogeneity from magnetic resonance residue data. J Cereb Blood Flow Metab 1999;19:690-9.
    • (1999) J. Cereb. Blood Flow Metab. , vol.19 , pp. 690-699
    • Ostergaard, L.1
  • 4
    • 0025871757 scopus 로고
    • Contrast agents and cerebral hemodynamics
    • Rosen BR, et al. Contrast agents and cerebral hemodynamics. Magn Reson Med 1991;19:285-92.
    • (1991) Magn. Reson. Med. , vol.19 , pp. 285-292
    • Rosen, B.R.1
  • 5
    • 0003568990 scopus 로고    scopus 로고
    • Cerebral MR perfusion imaging: Principles and current applications
    • Stuttgart: Thieme
    • Sorensen A, Reimer P. Cerebral MR perfusion imaging: Principles and current applications. Stuttgart: Thieme, 2000:152.
    • (2000) , pp. 152
    • Sorensen, A.1    Reimer, P.2
  • 6
    • 0031742176 scopus 로고    scopus 로고
    • An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: I. Theoretical derivation
    • St Lawrence KS, Lee TY. An adiabatic approximation to the tissue homogeneity model for water exchange in the brain: I. Theoretical derivation. J Cerebral Blood Flow Metab 1998;18:1365-77.
    • (1998) J. Cerebral Blood Flow Metab. , vol.18 , pp. 1365-1377
    • St. Lawrence, K.S.1    Lee, T.Y.2
  • 7
    • 0032828135 scopus 로고    scopus 로고
    • Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: Standardized quantities and symbols
    • Tofts PS, et al. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols. J Magn Reson Imaging 1999;10:223-32.
    • (1999) J. Magn. Reson. Imaging , vol.10 , pp. 223-332
    • Tofts, P.S.1
  • 8
    • 0342298515 scopus 로고    scopus 로고
    • Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors
    • Li KL, et al. Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors. J Magn Reson Imaging 2000;12:347-57.
    • (2000) J. Magn. Reson. Imaging , vol.12 , pp. 347-357
    • Li, K.L.1
  • 9
    • 0038083129 scopus 로고    scopus 로고
    • Cerebral perfusion imaging using contrast-enhanced MRI
    • Keston P, Murray AD, Jackson A. Cerebral perfusion imaging using contrast-enhanced MRI. Clin Radiol 2003; 58:505-13.
    • (2003) Clin. Radiol. , vol.58 , pp. 505-513
    • Keston, P.1    Murray, A.D.2    Jackson, A.3
  • 10
    • 0031722756 scopus 로고    scopus 로고
    • Cerebral blood flow measurements by magnetic resonance imaging bolus tracking: Comparison with [O15] H2O positron emmission tomography in humans
    • Ostergaard L, et al. Cerebral blood flow measurements by magnetic resonance imaging bolus tracking: comparison with [O15] H2O positron emmission tomography in humans. J Cereb Blood Flow Metab 1998;18:935-40.
    • (1998) J. Cereb. Blood Flow Metab. , vol.18 , pp. 935-940
    • Ostergaard, L.1
  • 11
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • Rempp KA, et al. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 1994;193:637-41.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1
  • 12
    • 0033812331 scopus 로고    scopus 로고
    • Delay and dispersion effects in dynamic susceptibility contrast MRI: Simulations using singular value decomposition
    • Calamante F, Gadian DG, Connelly A. Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition. Magn Reson Med 2000; 44:466-73.
    • (2000) Magn. Reson. Med. , vol.44 , pp. 466-473
    • Calamante, F.1    Gadian, D.G.2    Connelly, A.3
  • 13
    • 0031397843 scopus 로고    scopus 로고
    • Signal-to-noise analysis of cerebral blood volume maps from dynamic NMR imaging studies
    • Boxerman JL, Rosen BR, Weisskoff RM. Signal-to-noise analysis of cerebral blood volume maps from dynamic NMR imaging studies. J Magn Reson Imaging 1997;7:528-37.
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 528-537
    • Boxerman, J.L.1    Rosen, B.R.2    Weisskoff, R.M.3
  • 15
    • 0029096047 scopus 로고
    • MR contrast due to intravascular magnetic susceptibility perturbations
    • Boxerman JL, et al. MR contrast due to intravascular magnetic susceptibility perturbations. Magn Reson Med 1995;34:555-66.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 555-566
    • Boxerman, J.L.1
  • 16
    • 0034901219 scopus 로고    scopus 로고
    • Perfusion-sensitive MR imaging of gliomas: Comparison between gradient-echo and spin-echo echo-planar imaging techniques
    • Sugahara T, et al. Perfusion-sensitive MR imaging of gliomas: comparison between gradient-echo and spin-echo echo-planar imaging techniques. AJNR Am J Neuroradiol 2001;22: 1306-15.
    • (2001) AJNR Am. J. Neuroradiol. , vol.22 , pp. 1306-1315
    • Sugahara, T.1
  • 17
    • 0033950756 scopus 로고    scopus 로고
    • Abnormalities of the contrast re-circulation phase in cerebral tumors demonstrated using dynamic susceptibility contrast-enhanced imaging: A possible marker of vascular tortuosity
    • Kassner A, et al. Abnormalities of the contrast re-circulation phase in cerebral tumors demonstrated using dynamic susceptibility contrast-enhanced imaging: a possible marker of vascular tortuosity. J Magn Reson Imaging 2000;11: 103-13.
    • (2000) J. Magn. Reson. Imaging , vol.11 , pp. 103-113
    • Kassner, A.1
  • 18
    • 0028230438 scopus 로고
    • Cerebral blood volume maps of gliomas: Comparison with tumor grade and histologic findings
    • Aronen HJ, et al. Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings. Radiology 1994;191:41-51.
    • (1994) Radiology , vol.191 , pp. 41-51
    • Aronen, H.J.1
  • 19
    • 0037305185 scopus 로고    scopus 로고
    • Can dynamic susceptibility contrast magnetic resonance imaging perfusion data be analyzed using a model based on directional flow?
    • Thacker NA, Scott ML, Jackson A. Can dynamic susceptibility contrast magnetic resonance imaging perfusion data be analyzed using a model based on directional flow? J Magn Reson Imaging 2003;17:241-55.
    • (2003) J. Magn. Reson. Imaging , vol.17 , pp. 241-255
    • Thacker, N.A.1    Scott, M.L.2    Jackson, A.3
  • 20
    • 0025180569 scopus 로고
    • Perfusion imaging with NMR contrast agents
    • Rosen BR, et al. Perfusion imaging with NMR contrast agents. Magn Reson Med 1990;14:249-65.
    • (1990) Magn. Reson. Med. , vol.14 , pp. 249-265
    • Rosen, B.R.1
  • 21
    • 0021034659 scopus 로고
    • The derivation of gamma variat relationship for tracer dilution curves
    • Davenport R. The derivation of gamma variat relationship for tracer dilution curves. J Nucl Med 1983;24:945-8.
    • (1983) J. Nucl. Med. , vol.24 , pp. 945-948
    • Davenport, R.1
  • 22
    • 0030997814 scopus 로고    scopus 로고
    • Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise
    • Benner T, et al. Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: influence of time resolution, maximal signal drop and signal-to-noise. Magn Reson Imaging 1997;15:307-17.
    • (1997) Magn. Reson. Imaging , vol.15 , pp. 307-317
    • Benner, T.1
  • 24
    • 0037921967 scopus 로고    scopus 로고
    • Application of contrast agents in the evaluation of stroke: Conventional MR and echo-planar MR imaging
    • Maeda M, Maley JE, Crosby DL. Application of contrast agents in the evaluation of stroke: conventional MR and echo-planar MR imaging. J Magn Reson Med 1997;7: 723-8.
    • (1997) J. Magn. Reson. Med. , vol.7 , pp. 723-728
    • Maeda, M.1    Maley, J.E.2    Crosby, D.L.3
  • 25
    • 0031030146 scopus 로고    scopus 로고
    • Breast neoplasms: T2* susceptibility-contrast, first-pass perfusion MR imaging
    • [see comments]
    • Kuhl CK, et al. Breast neoplasms: T2* susceptibility-contrast, first-pass perfusion MR imaging [see comments]. Radiology 1997;202:87-95.
    • (1997) Radiology , vol.202 , pp. 87-95
    • Kuhl, C.K.1
  • 26
    • 0031413024 scopus 로고    scopus 로고
    • Dual dynamic contrast-enhanced MR imaging
    • Miyati T, et al. Dual dynamic contrast-enhanced MR imaging. J Magn Reson Imaging 1997;7:230-5.
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 230-235
    • Miyati, T.1
  • 27
    • 0027481892 scopus 로고
    • Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
    • Weisskoff RM, et al. Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time? Magn Reson Med 1993;29:553-8.
    • (1993) Magn. Reson. Med. , vol.29 , pp. 553-558
    • Weisskoff, R.M.1
  • 28
    • 0033985933 scopus 로고    scopus 로고
    • Quantitative perfusion imaging in carotid artery stenosis using dynamic susceptibility contrast-enhanced magnetic resonance imaging
    • Lythgoe DJ, et al. Quantitative perfusion imaging in carotid artery stenosis using dynamic susceptibility contrast-enhanced magnetic resonance imaging. Magn Reson Imaging 2000;18:1-11.
    • (2000) Magn. Reson. Imaging , vol.18 , pp. 1-11
    • Lythgoe, D.J.1
  • 29
    • 0034038538 scopus 로고    scopus 로고
    • 2* contrast-enhanced dynamic MR imaging
    • 2* contrast-enhanced dynamic MR imaging. J Magn Reson Imaging 2000;11:575-85.
    • (2000) J. Magn. Reson. Imaging , vol.11 , pp. 575-585
    • Zhu, X.P.1
  • 30
    • 0026011540 scopus 로고
    • Measurement of the blood brain barrier permeability and leakage space using dynamic MR imaging: Fundemental concepts
    • Tofts PS, Kermode AG. Measurement of the blood brain barrier permeability and leakage space using dynamic MR imaging: fundemental concepts. Magn Reson Med 1991;17: 357-67.
    • (1991) Magn. Reson. Med. , vol.17 , pp. 357-367
    • Tofts, P.S.1    Kermode, A.G.2
  • 31
    • 0037009827 scopus 로고    scopus 로고
    • Molecular imaging and biological evaluation of HuMV833 anti-VEGF antibody: Implications for trial design of antiangiogenic antibodies
    • Jayson GC, et al. Molecular imaging and biological evaluation of HuMV833 anti-VEGF antibody: implications for trial design of antiangiogenic antibodies. J Natl Cancer Inst 2002;94:1484-93.
    • (2002) J. Natl. Cancer Inst. , vol.94 , pp. 1484-1493
    • Jayson, G.C.1
  • 32
    • 0031425591 scopus 로고    scopus 로고
    • Vascular endothelial growth factor: A key mediator of neoangiogenesis. A review
    • Amoroso A, et al. Vascular endothelial growth factor: a key mediator of neoangiogenesis. A review. Eur Rev Med Pharmacolog Sci 1997;1:17-25.
    • (1997) Eur. Rev. Med. Pharmacolog. Sci. , vol.1 , pp. 17-25
    • Amoroso, A.1
  • 33
    • 0036984640 scopus 로고    scopus 로고
    • Role of angiogenesis in tumor growth and metastasis
    • Folkman J. Role of angiogenesis in tumor growth and metastasis. Semin Oncol 2002;29(6 Suppl 16):15-8.
    • (2002) Semin. Oncol. , vol.29 , Issue.6 SUPPL. 16 , pp. 15-18
    • Folkman, J.1
  • 34
    • 0031421953 scopus 로고    scopus 로고
    • Assessing tumor angiogenesis using macromolecular MR imaging contrast media
    • Brasch R, et al. Assessing tumor angiogenesis using macromolecular MR imaging contrast media. J Magn Reson Imaging 1997;7:68-74.
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 68-74
    • Brasch, R.1
  • 35
    • 0029004025 scopus 로고
    • Vascular permeability factor/vascular endothelial growth factor, microvascular hyperpermeability, and angiogenesis
    • Dvorak HF, et al. Vascular permeability factor/vascular endothelial growth factor, microvascular hyperpermeability, and angiogenesis. Am J Pathol 1995;146:1029-39.
    • (1995) Am. J. Pathol. , vol.146 , pp. 1029-1039
    • Dvorak, H.F.1
  • 36
    • 0032005359 scopus 로고    scopus 로고
    • Growth factor-mediated angiogenesis in the malignant progression of glial tumors: A review
    • discussion 196
    • Jensen RL. Growth factor-mediated angiogenesis in the malignant progression of glial tumors: a review. Surg Neurol 1998;49:189-95; discussion 196.
    • (1998) Surg. Neurol. , vol.49 , pp. 189-195
    • Jensen, R.L.1
  • 37
    • 0025137047 scopus 로고
    • Breast disease: Tissue characterization with Gd-DTPA enhancement profiles
    • Stack J, Redmond O, Codd M, et al. Breast disease: tissue characterization with Gd-DTPA enhancement profiles. Radiology 1990;174:491-4.
    • (1990) Radiology , vol.174 , pp. 491-494
    • Stack, J.1    Redmond, O.2    Codd, M.3
  • 38
    • 0027197952 scopus 로고
    • Differentiation of benign from malignant breast masses by time-intensity evaluation of contrast enhanced MRI
    • Flickinger F, et al. Differentiation of benign from malignant breast masses by time-intensity evaluation of contrast enhanced MRI. Magn Reson Imaging 1993;11:617-20.
    • (1993) Magn. Reson. Imaging , vol.11 , pp. 617-620
    • Flickinger, F.1
  • 39
    • 0025733610 scopus 로고
    • Pharmacokinetic parameters in CNS Gd-DTPA enhanced MR imaging
    • Brix G, et al. Pharmacokinetic parameters in CNS Gd-DTPA enhanced MR imaging. J Comp Assist Tomog 1991; 15:621-8.
    • (1991) J. Comp. Assist. Tomog. , vol.15 , pp. 621-628
    • Brix, G.1
  • 40
    • 0032863706 scopus 로고    scopus 로고
    • Pathophysiologic basis of contrast enhancement in breast tumors
    • Knopp MV, et al. Pathophysiologic basis of contrast enhancement in breast tumors. J Magn Reson Imaging 1999;10:260-6.
    • (1999) J. Magn. Reson. Imaging , vol.10 , pp. 260-266
    • Knopp, M.V.1
  • 41
    • 0033004433 scopus 로고    scopus 로고
    • Glial neoplasms: Dynamic contrast-enhanced T2*-weighted MR imaging
    • Knopp EA, et al. Glial neoplasms: dynamic contrast-enhanced T2*-weighted MR imaging. Radiology 1999;211: 791-8.
    • (1999) Radiology , vol.211 , pp. 791-798
    • Knopp, E.A.1
  • 42
    • 18844479070 scopus 로고    scopus 로고
    • Uterine cervical carcinoma: Comparison of standard and pharmacokinetic analysis of time-intensity curve for assessment of tumor angiogenesis and patient survival
    • Hawighorst H, et al. Uterine cervical carcinoma: comparison of standard and pharmacokinetic analysis of time-intensity curve for assessment of tumor angiogenesis and patient survival. Cancer Res 1998;58:3598-602.
    • (1998) Cancer Res. , vol.58 , pp. 3598-3602
    • Hawighorst, H.1
  • 43
    • 0034063192 scopus 로고    scopus 로고
    • Improving image quality and T(1) measurements using saturation recovery turboFLASH with an approximate K-space normalisation filter
    • Parker GJ, et al. Improving image quality and T(1) measurements using saturation recovery turboFLASH with an approximate K-space normalisation filter. Magn Reson Imaging 2000;18:157-67.
    • (2000) Magn. Reson. Imaging , vol.18 , pp. 157-167
    • Parker, G.J.1
  • 44
    • 2442442764 scopus 로고    scopus 로고
    • A comparison of Ktrans measurements obtained with conventional and first pass pharmacokinetic models in human gliomas
    • Haroon HA, et al. A comparison of Ktrans measurements obtained with conventional and first pass pharmacokinetic models in human gliomas. J Magn Reson Imaging 2004;19: 527-36.
    • (2004) J. Magn. Reson. Imaging , vol.19 , pp. 527-536
    • Haroon, H.A.1
  • 45
    • 0031404162 scopus 로고    scopus 로고
    • Modeling tracer kinetics in dynamic Gd-DTPA MR imaging
    • Tofts PS. Modeling tracer kinetics in dynamic Gd-DTPA MR imaging. J Magn Reson Imaging 1997;7:91-101.
    • (1997) J. Magn. Reson. Imaging , vol.7 , pp. 91-101
    • Tofts, P.S.1
  • 46
    • 0036193478 scopus 로고    scopus 로고
    • Breath-hold perfusion and permeability mapping of hepatic malignancies using magnetic resonance imaging and a first-pass leakage profile model
    • Jackson A, et al. Breath-hold perfusion and permeability mapping of hepatic malignancies using magnetic resonance imaging and a first-pass leakage profile model. NMR Biomed 2002;15:164-73.
    • (2002) NMR Biomed. , vol.15 , pp. 164-173
    • Jackson, A.1
  • 47
    • 0344737797 scopus 로고    scopus 로고
    • New hybrid technique for accurate and reproducible quantitation of dynamic contrast-enhanced MRI data
    • Li KL, Jackson A. New hybrid technique for accurate and reproducible quantitation of dynamic contrast-enhanced MRI data. Magn Reson Med 2003;50:1286-95.
    • (2003) Magn. Reson. Med. , vol.50 , pp. 1286-1295
    • Li, K.L.1    Jackson, A.2
  • 48
    • 0037280345 scopus 로고    scopus 로고
    • Simultaneous mapping of blood volume and endothelial permeability surface area product in gliomas using iterative analysis of first-pass dynamic contrast enhanced MRI data
    • Li KL, et al. Simultaneous mapping of blood volume and endothelial permeability surface area product in gliomas using iterative analysis of first-pass dynamic contrast enhanced MRI data. Br J Radiol 2003;76:39-50.
    • (2003) Br. J. Radiol. , vol.76 , pp. 39-50
    • Li, K.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.