메뉴 건너뛰기




Volumn 15, Issue 3, 1997, Pages 307-317

Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise

Author keywords

Computer simulation; Concentration time curves; Gamma variate function; SNR; T2* weighted MRI

Indexed keywords

ARTICLE; CIRCULATION; COMPUTER SIMULATION; CONTRAST ENHANCEMENT; MATHEMATICAL MODEL; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SIGNAL NOISE RATIO;

EID: 0030997814     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0730-725X(96)00392-X     Document Type: Article
Times cited : (104)

References (28)
  • 4
    • 77049181625 scopus 로고
    • On the theory of the indicator-dilution method for measurement of blood flow and volume
    • 4. Meier, P.; Zierler, K.L. On the theory of the indicator-dilution method for measurement of blood flow and volume. J. Appl. Physiol. 6:731-744; 1954.
    • (1954) J. Appl. Physiol. , vol.6 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 5
    • 0019163790 scopus 로고
    • Cerebral blood flow determination by rapid-sequence computed tomography: A theoretical analysis
    • 5. Axel, L. Cerebral blood flow determination by rapid-sequence computed tomography: A theoretical analysis. Radiology 137:679-686; 1980.
    • (1980) Radiology , vol.137 , pp. 679-686
    • Axel, L.1
  • 8
    • 0027481892 scopus 로고
    • Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
    • 8. Weisskoff, R.M.; Chesler, D.; Boxerman, J.L.; Rosen, B.R. Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time? Magn. Reson. Med. 29:553-559; 1993.
    • (1993) Magn. Reson. Med. , vol.29 , pp. 553-559
    • Weisskoff, R.M.1    Chesler, D.2    Boxerman, J.L.3    Rosen, B.R.4
  • 9
    • 0000169232 scopus 로고
    • An algorithm for least squares estimation of non-linear parameters
    • 9. Marquardt, D.W. An algorithm for least squares estimation of non-linear parameters. J. Soc. Ind. Appl. Math. 11:431-441; 1963.
    • (1963) J. Soc. Ind. Appl. Math. , vol.11 , pp. 431-441
    • Marquardt, D.W.1
  • 13
    • 0023481216 scopus 로고
    • Kinetic data analysis with a noisy input function
    • 13. Huesman, R.H.; Mazoyer, B.M. Kinetic data analysis with a noisy input function. Phys. Med. Biol. 30:1569-1579; 1987.
    • (1987) Phys. Med. Biol. , vol.30 , pp. 1569-1579
    • Huesman, R.H.1    Mazoyer, B.M.2
  • 14
    • 0027177401 scopus 로고
    • Effect of sample numbers on the kinetic data analysis of MR contrast agents
    • 14. Lu, D.; Monahan, W.G. Effect of sample numbers on the kinetic data analysis of MR contrast agents. Magn. Reson. Med. 30:131-134; 1993.
    • (1993) Magn. Reson. Med. , vol.30 , pp. 131-134
    • Lu, D.1    Monahan, W.G.2
  • 18
    • 0026008719 scopus 로고
    • In vitro evaluation of a mechanical injector for infusion of magnetic resonance contrast media
    • 18. Saini, S.; Fretz, C.J.; Fisel, R.; Rosen, B.R.; Ferrucci, J.T. In vitro evaluation of a mechanical injector for infusion of magnetic resonance contrast media, Invest. Radiol. 26:748-751; 1991.
    • (1991) Invest. Radiol. , vol.26 , pp. 748-751
    • Saini, S.1    Fretz, C.J.2    Fisel, R.3    Rosen, B.R.4    Ferrucci, J.T.5
  • 20
    • 0021034659 scopus 로고
    • The derivation of the gamma-variate relationship for tracer dilution curves
    • 20. Davenport, R. The derivation of the gamma-variate relationship for tracer dilution curves. J. Nucl. Med. 24: 945-948; 1983.
    • (1983) J. Nucl. Med. , vol.24 , pp. 945-948
    • Davenport, R.1
  • 22
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • 22. Rempp, K.A.; Brix, G.; Wenz, F.; Becker, C.R.; Gückel, F.; Lorenz, W.J. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 193:637-641; 1994.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Gückel, F.5    Lorenz, W.J.6
  • 23
    • 0018080066 scopus 로고
    • Local cerebral blood volume response to carbon dioxide in man
    • 23. Greenberg, J.H.; Alavi, A.; Reivich, M.; Kuhl, D.; Uzzell, B. Local cerebral blood volume response to carbon dioxide in man. Circ. Res. 43:324-331; 1978.
    • (1978) Circ. Res. , vol.43 , pp. 324-331
    • Greenberg, J.H.1    Alavi, A.2    Reivich, M.3    Kuhl, D.4    Uzzell, B.5
  • 25
    • 0028288722 scopus 로고
    • Assessment of cerebral blood volume with dynamic susceptibility contrast enhanced gradient-echo imaging
    • 25. Gückel, F.; Brix, G.; Rempp, K.; Deimling, M.; Röther, J.; Georgi, M. Assessment of cerebral blood volume with dynamic susceptibility contrast enhanced gradient-echo imaging. J. Comput. Assist. Tomogr. 18(3):344-351; 1994.
    • (1994) J. Comput. Assist. Tomogr. , vol.18 , Issue.3 , pp. 344-351
    • Gückel, F.1    Brix, G.2    Rempp, K.3    Deimling, M.4    Röther, J.5    Georgi, M.6
  • 26
    • 0026482768 scopus 로고
    • Simultaneous MR acquisition of arterial and brain signal-time curves
    • 26. Perman, W.H.; Gado, M.H.; Larson, K.B.; Perlmutter, J.S. Simultaneous MR acquisition of arterial and brain signal-time curves. Magn. Reson. Med. 28:74-83; 1992.
    • (1992) Magn. Reson. Med. , vol.28 , pp. 74-83
    • Perman, W.H.1    Gado, M.H.2    Larson, K.B.3    Perlmutter, J.S.4
  • 27
    • 0018384498 scopus 로고
    • Validation of tomographic measurement of cerebral blood volume with C-11-labeled carboxyhemoglobin
    • 27. Phelps, M.E.; Huang, S.C.; Hoffman, E.J.; Kuhl, D.E. Validation of tomographic measurement of cerebral blood volume with C-11-labeled carboxyhemoglobin. J. Nucl. Med. 20:328-334; 1979.
    • (1979) J. Nucl. Med. , vol.20 , pp. 328-334
    • Phelps, M.E.1    Huang, S.C.2    Hoffman, E.J.3    Kuhl, D.E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.