메뉴 건너뛰기




Volumn 112, Issue 2, 2005, Pages 238-244

Anterior chamber width measurement by high-speed optical coherence tomography

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; ANALYSIS OF VARIANCE; ANTERIOR EYE CHAMBER; ANTERIOR EYE SEGMENT; ARTICLE; BIOMETRY; COMPUTER; COMPUTER PROGRAM; CORNEA; FEMALE; HUMAN; IMAGING; LENS; LENS IMPLANT; LINEAR REGRESSION ANALYSIS; MALE; MEASUREMENT; MOTION; NORMAL HUMAN; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; REPRODUCIBILITY; SCANNING ELECTROCHEMICAL MICROSCOPY; STATISTICAL SIGNIFICANCE;

EID: 13444293104     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2004.09.019     Document Type: Article
Times cited : (195)

References (31)
  • 1
    • 0036678051 scopus 로고    scopus 로고
    • Phakic intraocular lenses and refractory lensectomy for myopia
    • T.P. O'Brien, S.T. Awwad Phakic intraocular lenses and refractory lensectomy for myopia Curr Opin Ophthalmol 13 2002 264 270
    • (2002) Curr Opin Ophthalmol , vol.13 , pp. 264-270
    • O'Brien, T.P.1    Awwad, S.T.2
  • 2
    • 0033805132 scopus 로고    scopus 로고
    • Multicenter study of the Artisan phakic intraocular lens
    • C. Budo, J.C. Hessloehl, M. Izak Multicenter study of the Artisan phakic intraocular lens J Cataract Refract Surg 26 2000 1163 1171
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1163-1171
    • Budo, C.1    Hessloehl, J.C.2    Izak, M.3
  • 4
    • 0034114149 scopus 로고    scopus 로고
    • Phakic posterior chamber lenses for high myopia: Functional and anatomical outcomes
    • J.L. Arne, L.C. Lesueur Phakic posterior chamber lenses for high myopia: functional and anatomical outcomes J Cataract Refract Surg 26 2000 369 374
    • (2000) J Cataract Refract Surg , vol.26 , pp. 369-374
    • Arne, J.L.1    Lesueur, L.C.2
  • 5
    • 0033808975 scopus 로고    scopus 로고
    • Cataract surgery in highly myopic eyes corrected by phakic anterior chamber angle-supported lenses
    • J.L. Alio, F. de la Hoz, J.M. Ruiz-Moreno, T.F. Salem Cataract surgery in highly myopic eyes corrected by phakic anterior chamber angle-supported lenses J Cataract Refract Surg 26 2000 1303 1311
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1303-1311
    • Alio, J.L.1    De La Hoz, F.2    Ruiz-Moreno, J.M.3    Salem, T.F.4
  • 7
    • 0033769605 scopus 로고    scopus 로고
    • Myopic angle-supported intraocular lenses: Two-year follow-up
    • N. Allemann, W. Chamon, H.M. Tanaka Myopic angle-supported intraocular lenses: two-year follow-up Ophthalmology 107 2000 1549 1554
    • (2000) Ophthalmology , vol.107 , pp. 1549-1554
    • Allemann, N.1    Chamon, W.2    Tanaka, H.M.3
  • 8
    • 0031782411 scopus 로고    scopus 로고
    • Angle-fixated anterior chamber phakic intraocular lens for myopia of -7 to -19 diopters
    • G. Baikoff, J.L. Arne, Y. Bokobza Angle-fixated anterior chamber phakic intraocular lens for myopia of -7 to -19 diopters J Refract Surg 14 1998 282 293
    • (1998) J Refract Surg , vol.14 , pp. 282-293
    • Baikoff, G.1    Arne, J.L.2    Bokobza, Y.3
  • 9
    • 0027394741 scopus 로고
    • Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: Case reports
    • J.J. Saragoussi, P. Othenin-Girard, Y.J. Pouliquen Ocular damage after implantation of oversized minus power anterior chamber intraocular lenses in myopic phakic eyes: case reports Refract Corneal Surg 9 1993 105 109
    • (1993) Refract Corneal Surg , vol.9 , pp. 105-109
    • Saragoussi, J.J.1    Othenin-Girard, P.2    Pouliquen, Y.J.3
  • 11
    • 0021239195 scopus 로고
    • Complications of intraocular lenses: A historical and histopathological review
    • D.J. Apple, N. Mamalis, K. Loftfield Complications of intraocular lenses A historical and histopathological review Surv Ophthalmol 29 1984 1 54
    • (1984) Surv Ophthalmol , vol.29 , pp. 1-54
    • Apple, D.J.1    Mamalis, N.2    Loftfield, K.3
  • 12
    • 0023127023 scopus 로고
    • Anterior chamber lenses: Part I: Complications and pathology and a review of designs
    • D.J. Apple, R.N. Brems, R.B. Park Anterior chamber lenses Part I: complications and pathology and a review of designs J Cataract Refract Surg 13 1987 157 174
    • (1987) J Cataract Refract Surg , vol.13 , pp. 157-174
    • Apple, D.J.1    Brems, R.N.2    Park, R.B.3
  • 13
    • 0018969506 scopus 로고
    • Instruments and techniques for anterior chamber implants
    • J.R. Karickhoff Instruments and techniques for anterior chamber implants Arch Ophthalmol 98 1980 1265 1267
    • (1980) Arch Ophthalmol , vol.98 , pp. 1265-1267
    • Karickhoff, J.R.1
  • 14
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • D. Huang, E.A. Swanson, C.P. Lin Optical coherence tomography Science 254 1991 1178 1181
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 15
    • 0034038860 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism
    • Maldonado MJ, Ruiz-Oblitas L, Munuera JM, et al. Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism. Ophthalmology 2000;107:81-7, discussion 88.
    • (2000) Ophthalmology , vol.107 , pp. 81-87
    • Maldonado, M.J.1    Ruiz-Oblitas, L.2    Munuera, J.M.3
  • 16
    • 0036260383 scopus 로고    scopus 로고
    • Optical coherence tomographic findings of the anterior segment after nonpenetrating deep sclerectomy
    • M. Nozaki, H. Kimura, M. Kojima, Y. Ogura Optical coherence tomographic findings of the anterior segment after nonpenetrating deep sclerectomy Am J Ophthalmol 133 2002 837 839
    • (2002) Am J Ophthalmol , vol.133 , pp. 837-839
    • Nozaki, M.1    Kimura, H.2    Kojima, M.3    Ogura, Y.4
  • 17
    • 0027985314 scopus 로고
    • Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography
    • J.A. Izatt, M.R. Hee, E.A. Swanson Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography Arch Ophthalmol 112 1994 1584 1589
    • (1994) Arch Ophthalmol , vol.112 , pp. 1584-1589
    • Izatt, J.A.1    Hee, M.R.2    Swanson, E.A.3
  • 18
    • 0034899732 scopus 로고    scopus 로고
    • Real-time optical coherence tomography of the anterior segment at 1310 nm
    • S. Radhakrishnan, A.M. Rollins, J.E. Roth Real-time optical coherence tomography of the anterior segment at 1310 nm Arch Ophthalmol 119 2001 1179 1185
    • (2001) Arch Ophthalmol , vol.119 , pp. 1179-1185
    • Radhakrishnan, S.1    Rollins, A.M.2    Roth, J.E.3
  • 19
    • 1942443651 scopus 로고    scopus 로고
    • Optical coherence tomography of the anterior segment of the eye
    • D. Huang, Y. Li, S. Radhakrishnan Optical coherence tomography of the anterior segment of the eye Ophthalmol Clin North Am 17 2004 1 6
    • (2004) Ophthalmol Clin North Am , vol.17 , pp. 1-6
    • Huang, D.1    Li, Y.2    Radhakrishnan, S.3
  • 22
    • 2942538426 scopus 로고    scopus 로고
    • Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster
    • A.R. Reddy, M.V. Pande, P. Finn, H. El-Gogary Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster J Cataract Refract Surg 30 2004 1268 1271
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1268-1271
    • Reddy, A.R.1    Pande, M.V.2    Finn, P.3    El-Gogary, H.4
  • 23
    • 2942641855 scopus 로고    scopus 로고
    • Laser vs ultrasound biometry: A study of intra- and interobserver variability
    • S. Goel, C. Chua, M. Butcher Laser vs ultrasound biometry: a study of intra- and interobserver variability Eye 18 2004 514 518
    • (2004) Eye , vol.18 , pp. 514-518
    • Goel, S.1    Chua, C.2    Butcher, M.3
  • 24
    • 0346118994 scopus 로고    scopus 로고
    • Anterior chamber depth in relation to refractive status measured with the Orbscan II Topography System
    • T.M. Rabsilber, K.A. Becker, I.B. Frisch, G.U. Auffarth Anterior chamber depth in relation to refractive status measured with the Orbscan II Topography System J Cataract Refract Surg 29 2003 2115 2121
    • (2003) J Cataract Refract Surg , vol.29 , pp. 2115-2121
    • Rabsilber, T.M.1    Becker, K.A.2    Frisch, I.B.3    Auffarth, G.U.4
  • 25
    • 0036967062 scopus 로고    scopus 로고
    • Predicting postoperative anterior chamber depth in cataract patients using Scheimpflug slit photography
    • H. Sasaki, Y. Sakamoto, S. Harada Predicting postoperative anterior chamber depth in cataract patients using Scheimpflug slit photography Ophthalmic Res 34 2002 265 272
    • (2002) Ophthalmic Res , vol.34 , pp. 265-272
    • Sasaki, H.1    Sakamoto, Y.2    Harada, S.3
  • 26
    • 0742305077 scopus 로고    scopus 로고
    • Ocular component measurement using the Zeiss IOLMaster
    • H. Sheng, C.A. Bottjer, M.A. Bullimore Ocular component measurement using the Zeiss IOLMaster Optom Vis Sci 81 2004 27 34
    • (2004) Optom Vis Sci , vol.81 , pp. 27-34
    • Sheng, H.1    Bottjer, C.A.2    Bullimore, M.A.3
  • 27
    • 0742322729 scopus 로고    scopus 로고
    • Variability of the ocular component measurements in children using A-scan ultrasonography
    • COMET Study Group M.
    • D. Kurtz, R. Manny, M. Hussein COMET Study Group Variability of the ocular component measurements in children using A-scan ultrasonography Optom Vis Sci 81 2004 35 43
    • (2004) Optom Vis Sci , vol.81 , pp. 35-43
    • Kurtz, D.1    Manny, R.2    Hussein3
  • 28
    • 0037827011 scopus 로고    scopus 로고
    • Agreement between Scheimpflug photography and A-scan ultrasonography in anterior segment ocular measurements in children
    • L. Tong, E.H. Wong, Y.H. Chan, V. Balakrishnan Agreement between Scheimpflug photography and A-scan ultrasonography in anterior segment ocular measurements in children Optom Vis Sci 80 2003 529 534
    • (2003) Optom Vis Sci , vol.80 , pp. 529-534
    • Tong, L.1    Wong, E.H.2    Chan, Y.H.3    Balakrishnan, V.4
  • 29
    • 0038329287 scopus 로고    scopus 로고
    • Ultrasonographic biomicroscopy, Scheimpflug photography, and novel provocative tests in contralateral eyes of Chinese patients initially seen with acute angle closure
    • D.S. Friedman, G. Gazzard, P. Foster Ultrasonographic biomicroscopy, Scheimpflug photography, and novel provocative tests in contralateral eyes of Chinese patients initially seen with acute angle closure Arch Ophthalmol 121 2003 633 642
    • (2003) Arch Ophthalmol , vol.121 , pp. 633-642
    • Friedman, D.S.1    Gazzard, G.2    Foster, P.3
  • 30
    • 0037257069 scopus 로고    scopus 로고
    • Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes
    • K. Kriechbaum, O. Findl, B. Kiss Comparison of anterior chamber depth measurement methods in phakic and pseudophakic eyes J Cataract Refract Surg 29 2003 89 94
    • (2003) J Cataract Refract Surg , vol.29 , pp. 89-94
    • Kriechbaum, K.1    Findl, O.2    Kiss, B.3
  • 31
    • 0037254713 scopus 로고    scopus 로고
    • Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation
    • J. Nemeth, O. Fekete, N. Pesztenlehrer Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation J Cataract Refract Surg 29 2003 85 88
    • (2003) J Cataract Refract Surg , vol.29 , pp. 85-88
    • Nemeth, J.1    Fekete, O.2    Pesztenlehrer, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.