Volumn 80, Issue 7, 2003, Pages 529-534

Agreement between Scheimpflug photography and A-scan ultrasonography in anterior segment ocular measurements in children

Author keywords

Biometry; Comparative study; Epidemiology; Human; Instrument; Photography; Ultrasonography

Indexed keywords

PHOTOGRAPHY; SCANNING; THICKNESS MEASUREMENT; ULTRASONICS;

EID: 0037827011     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/00006324-200307000-00014     Document Type: Article
Times cited : (11)

References (45)
  • 1
    • 0014166644 scopus 로고
    • Linear A-scan ultrasonography in the measurement of intra-ocular distances: A stand-off technique
    • Lowe RF. Linear A-scan ultrasonography in the measurement of intra-ocular distances: a stand-off technique. Trans Ophthalmol Soc Aust 1967;26:72-7.
    • (1967) Trans Ophthalmol Soc Aust , vol.26 , pp. 72-77
    • Lowe, R.F.1
  • 4
    • 0025336954 scopus 로고
    • Comparison of A-scan device accuracy
    • Giers U, Epple C. Comparison of A-scan device accuracy. J Cataract Refract Surg 1990;16:235-42.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 235-242
    • Giers, U.1    Epple, C.2
  • 5
    • 0031820198 scopus 로고    scopus 로고
    • Ultrasound biomicroscopy: I. Precision of measurements
    • Urbak SF. Ultrasound biomicroscopy: I. Precision of measurements. Acta Ophthalmol Scand 1998;76:447-55.
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 447-455
    • Urbak, S.F.1
  • 7
    • 0033152804 scopus 로고    scopus 로고
    • A 2-year longitudinal study of myopia progression and optical component changes among Hong Kong schoolchildren
    • Lam CS, Edwards M, Millodot M, Goh WS. A 2-year longitudinal study of myopia progression and optical component changes among Hong Kong schoolchildren. Optom Vis Sci 1999;76:370-80.
    • (1999) Optom Vis Sci , vol.76 , pp. 370-380
    • Lam, C.S.1    Edwards, M.2    Millodot, M.3    Goh, W.S.4
  • 9
    • 0036363651 scopus 로고    scopus 로고
    • A multiple regression approach to study optical components of myopia in Singapore school children
    • Tong L, Wong EH, Chan YH, Balakrishnan V. A multiple regression approach to study optical components of myopia in Singapore school children. Ophthalmic Physiol Opt 2002;22:32-7.
    • (2002) Ophthalmic Physiol Opt , vol.22 , pp. 32-37
    • Tong, L.1    Wong, E.H.2    Chan, Y.H.3    Balakrishnan, V.4
  • 10
    • 0026652930 scopus 로고
    • The repeatability of measurement of the ocular components
    • Zadnik K, Mutti DO, Adams AJ. The repeatability of measurement of the ocular components. Invest Ophthalmol Vis Sci 1992;33: 2325-33.
    • (1992) Invest Ophthalmol Vis Sci , vol.33 , pp. 2325-2333
    • Zadnik, K.1    Mutti, D.O.2    Adams, A.J.3
  • 11
  • 12
    • 0021356383 scopus 로고
    • Photometric oculometry: II. Measurement of axial ocular distances with slit-lamp microscopy: Clinical evaluation, and comparison with ultrasonography
    • Krogsaa B, Fledelius H, Larsen J, Lund-Andersen H. Photometric oculometry: II. Measurement of axial ocular distances with slit-lamp microscopy: clinical evaluation, and comparison with ultrasonography. Acta Ophthalmol (Copenh) 1984;62:290-9.
    • (1984) Acta Ophthalmol (Copenh) , vol.62 , pp. 290-299
    • Krogsaa, B.1    Fledelius, H.2    Larsen, J.3    Lund-Andersen, H.4
  • 13
    • 0023890688 scopus 로고
    • Depth measurement with the slit-lamp microscope
    • Perkins ES. Depth measurement with the slit-lamp microscope. Br J Ophthalmol 1988;72:344-7.
    • (1988) Br J Ophthalmol , vol.72 , pp. 344-347
    • Perkins, E.S.1
  • 16
    • 0036257336 scopus 로고    scopus 로고
    • Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study
    • Eysteinsson T, Jonasson F, Sasaki H, Arnarsson A, Sverrisson T, Sasaki K, Stefansson E. Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study. Acta Ophthalmol Scand 2002;80:11-5.
    • (2002) Acta Ophthalmol Scand , vol.80 , pp. 11-15
    • Eysteinsson, T.1    Jonasson, F.2    Sasaki, H.3    Arnarsson, A.4    Sverrisson, T.5    Sasaki, K.6    Stefansson, E.7
  • 17
    • 0026464792 scopus 로고
    • Scheimpflug photography in clinical ophthalmology: A review
    • Muller-Breitenkamp U, Hockwin O. Scheimpflug photography in clinical ophthalmology: a review. Ophthalmic Res 1992;24(Suppl 1):47-54.
    • (1992) Ophthalmic Res , vol.24 , Issue.SUPPL. 1 , pp. 47-54
    • Muller-Breitenkamp, U.1    Hockwin, O.2
  • 18
    • 0026549374 scopus 로고
    • Biometric constancy of the anterior eye segment as demonstrated by slit image photography according to the Scheimpflug principle
    • Olbert D, Kehrhahn OH. Biometric constancy of the anterior eye segment as demonstrated by slit image photography according to the Scheimpflug principle. Ophthalmic Res 1992;24:27-31.
    • (1992) Ophthalmic Res , vol.24 , pp. 27-31
    • Olbert, D.1    Kehrhahn, O.H.2
  • 19
    • 0025326509 scopus 로고
    • The multi-purpose camera: A new anterior eye segment analysis system
    • Sasaki K, Sakamoto Y, Shibata T, Emori Y. The multi-purpose camera: a new anterior eye segment analysis system. Ophthalmic Res 1990;22:3-8.
    • (1990) Ophthalmic Res , vol.22 , pp. 3-8
    • Sasaki, K.1    Sakamoto, Y.2    Shibata, T.3    Emori, Y.4
  • 21
    • 0024237291 scopus 로고
    • A method for improved biometry of the anterior chamber with a Scheimpflug technique
    • Richards DW, Russell SR, Anderson DR. A method for improved biometry of the anterior chamber with a Scheimpflug technique. Invest Ophthalmol Vis Sci 1988;29:1826-35.
    • (1988) Invest Ophthalmol Vis Sci , vol.29 , pp. 1826-1835
    • Richards, D.W.1    Russell, S.R.2    Anderson, D.R.3
  • 22
    • 0020629737 scopus 로고
    • Biometry of the anterior eye segment by Scheimpflug photography
    • Hockwin O, Weigelin E, Laser H, Dragomirescu V. Biometry of the anterior eye segment by Scheimpflug photography. Ophthalmic Res 1983;15:102-8.
    • (1983) Ophthalmic Res , vol.15 , pp. 102-108
    • Hockwin, O.1    Weigelin, E.2    Laser, H.3    Dragomirescu, V.4
  • 23
    • 0033820671 scopus 로고    scopus 로고
    • Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant
    • Vetrugno M, Cardascia N, Cardia L. Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant. Br J Ophthalmol 2000;84:1113-6.
    • (2000) Br J Ophthalmol , vol.84 , pp. 1113-1116
    • Vetrugno, M.1    Cardascia, N.2    Cardia, L.3
  • 25
    • 0035210450 scopus 로고    scopus 로고
    • Anterior chamber depth estimation by Scheimpflug photography
    • Holmen JB, Ekesten B, Lundgren B. Anterior chamber depth estimation by Scheimpflug photography. Acta Ophthalmol Scand 2001;79: 576-9.
    • (2001) Acta Ophthalmol Scand , vol.79 , pp. 576-579
    • Holmen, J.B.1    Ekesten, B.2    Lundgren, B.3
  • 26
    • 0026486702 scopus 로고
    • Nonlinear equations for calculating lens parameters based on Scheimpflug photographs: Preliminary results
    • Kehrhahn OH, Olbert D. Nonlinear equations for calculating lens parameters based on Scheimpflug photographs: preliminary results. Ophthalmic Res 1992;24(Suppl 1):63-8.
    • (1992) Ophthalmic Res , vol.24 , Issue.SUPPL. 1 , pp. 63-68
    • Kehrhahn, O.H.1    Olbert, D.2
  • 27
    • 0032084613 scopus 로고    scopus 로고
    • Methods to obtain quantitative parametric descriptions of the optical surfaces of the human crystalline lens from Scheimpflug slit-lamp images: I. Image processing methods
    • Cook CA, Koretz JF. Methods to obtain quantitative parametric descriptions of the optical surfaces of the human crystalline lens from Scheimpflug slit-lamp images: I. Image processing methods. J Opt Soc Am (A) 1998;15:1473-85.
    • (1998) J Opt Soc Am (A) , vol.15 , pp. 1473-1485
    • Cook, C.A.1    Koretz, J.F.2
  • 28
    • 0027209734 scopus 로고
    • Estimation of the thickness of the crystalline lens from on-axis and off-axis Scheimpflug photographs
    • Sparrow JM, Brown NA, Bron AJ. Estimation of the thickness of the crystalline lens from on-axis and off-axis Scheimpflug photographs. Ophthalmic Physiol Opt 1993;13:291-4.
    • (1993) Ophthalmic Physiol Opt , vol.13 , pp. 291-294
    • Sparrow, J.M.1    Brown, N.A.2    Bron, A.J.3
  • 29
    • 0036169561 scopus 로고    scopus 로고
    • Anterior chamber depth measurement: A-scan versus optical methods
    • Koranyi G, Lydahl E, Norrby S, Taube M. Anterior chamber depth measurement: A-scan versus optical methods. J Cataract Refract Surg 2002;28:243-7.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 243-247
    • Koranyi, G.1    Lydahl, E.2    Norrby, S.3    Taube, M.4
  • 30
    • 0033014940 scopus 로고    scopus 로고
    • Ultrasound biomicroscopic study on changes of ocular anterior segment structure after topical application of cycloplegia
    • Wang T, Liu L, Li Z, Hu S, Yang W, Zhu X. Ultrasound biomicroscopic study on changes of ocular anterior segment structure after topical application of cycloplegia. Chin Med J (Engl) 1999;112: 217-20.
    • (1999) Chin Med J (Engl) , vol.112 , pp. 217-220
    • Wang, T.1    Liu, L.2    Li, Z.3    Hu, S.4    Yang, W.5    Zhu, X.6
  • 31
    • 0026521859 scopus 로고
    • Optimal pupil diameter for Scheimpflug slit image photography of the lens in man
    • Cheeks LT, Summerer RW, Green K. Optimal pupil diameter for Scheimpflug slit image photography of the lens in man. Ophthalmic Res 1992;24:15-9.
    • (1992) Ophthalmic Res , vol.24 , pp. 15-19
    • Cheeks, L.T.1    Summerer, R.W.2    Green, K.3
  • 32
    • 0028848278 scopus 로고
    • The use of Sclleimpflug photography in the documentation of clinical states and in the biometry of the anterior eye segment
    • Olbert D. The use of Sclleimpflug photography in the documentation of clinical states and in the biometry of the anterior eye segment. Ophthalmic Res 1995;27(Suppl 1):20-4.
    • (1995) Ophthalmic Res , vol.27 , Issue.SUPPL. 1 , pp. 20-24
    • Olbert, D.1
  • 33
    • 0026378371 scopus 로고
    • Inter and intra observer reproducibility of the new Oxford CCD Scheimpflug camera
    • Harris ML, Smith GT, Brown NA. Inter and intra observer reproducibility of the new Oxford CCD Scheimpflug camera. Eye 1991; 5(Pt 4):487-90.
    • (1991) Eye , vol.5 , Issue.PART 4 , pp. 487-490
    • Harris, M.L.1    Smith, G.T.2    Brown, N.A.3
  • 34
    • 0033193410 scopus 로고    scopus 로고
    • Agreement berween A-mode and B-mode ultrasonography in the measurement of ocular distances
    • Hamidzada WA, Osuobeni EP. Agreement berween A-mode and B-mode ultrasonography in the measurement of ocular distances. Vet Radiol Ultrasound 1999;40:502-7.
    • (1999) Vet Radiol Ultrasound , vol.40 , pp. 502-507
    • Hamidzada, W.A.1    Osuobeni, E.P.2
  • 35
    • 0026698174 scopus 로고
    • Effects of different ocular fixation conditions on A-scan ultrasound biometry measurements
    • Steele CF, Crabb DP, Edgar DF. Effects of different ocular fixation conditions on A-scan ultrasound biometry measurements. Ophthalmic Physiol Opt 1992;12:491-5.
    • (1992) Ophthalmic Physiol Opt , vol.12 , pp. 491-495
    • Steele, C.F.1    Crabb, D.P.2    Edgar, D.F.3
  • 36
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 37
    • 0021949680 scopus 로고
    • Measurement of anterior chamber diameter and biometry of anterior segment by Scheimpflug slitlamp photography
    • Lerman S, Hockwin O. Measurement of anterior chamber diameter and biometry of anterior segment by Scheimpflug slitlamp photography. J Am Intraocul Implant Soc 1985;11:149-52.
    • (1985) J Am Intraocul Implant Soc , vol.11 , pp. 149-152
    • Lerman, S.1    Hockwin, O.2
  • 38
    • 0026341801 scopus 로고
    • Optical problems of anterior chamber depth biometry by Scheimpflug photography
    • Olbert D. Optical problems of anterior chamber depth biometry by Scheimpflug photography. Ophthalmic Res 1991;23:342-7.
    • (1991) Ophthalmic Res , vol.23 , pp. 342-347
    • Olbert, D.1
  • 39
    • 0024539797 scopus 로고
    • Immersion versus contact technique in the measurement of axial length by ultrasound
    • Olsen T, Nielsen PJ. Immersion versus contact technique in the measurement of axial length by ultrasound. Acta Ophthalmol (Copenh) 1989;67:101-2.
    • (1989) Acta Ophthalmol (Copenh) , vol.67 , pp. 101-102
    • Olsen, T.1    Nielsen, P.J.2
  • 42
    • 0024315421 scopus 로고
    • Comparison of contact and immersion techniques for axial length measurement and implant power calculation
    • Schelenz J, Kammann J. Comparison of contact and immersion techniques for axial length measurement and implant power calculation. J Cataract Refract Surg 1989;15:425-8.
    • (1989) J Cataract Refract Surg , vol.15 , pp. 425-428
    • Schelenz, J.1    Kammann, J.2
  • 44
    • 0034957865 scopus 로고    scopus 로고
    • The thickness of the aging human lens obtained from corrected Scheimpflug images
    • Dubbelman M, van der Heijde GL, Weeber HA. The thickness of the aging human lens obtained from corrected Scheimpflug images. Optom Vis Sci 2001;78:411-6.
    • (2001) Optom Vis Sci , vol.78 , pp. 411-416
    • Dubbelman, M.1    Van der Heijde, G.L.2    Weeber, H.A.3
  • 45
    • 0035022540 scopus 로고    scopus 로고
    • The shape of the aging human lens: Curvature, equivalent refractive index and the lens paradox
    • Dubbelman M, Van der Heijde GL. The shape of the aging human lens: curvature, equivalent refractive index and the lens paradox. Vision Res 2001;41:1867-77.
    • (2001) Vision Res , vol.41 , pp. 1867-1877
    • Dubbelman, M.1    Van der Heijde, G.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.