-
2
-
-
0023858680
-
Comparison of the SRK II formula and other second generation formulas
-
Sanders DR, Retzlaff J, Kraff MC: Comparison of the SRK II formula and other second generation formulas. J Cataract Refract Surg 1998;14:136-141.
-
(1998)
J Cataract Refract Surg
, vol.14
, pp. 136-141
-
-
Sanders, D.R.1
Retzlaff, J.2
Kraff, M.C.3
-
3
-
-
0028799073
-
Intraocular lens power calculation for short eye
-
Kora Y, Nishihara H, Inatomi M, et al: intraocular lens power calculation for short eye. Nichigan 1995;99:1186-1189.
-
(1995)
Nichigan
, vol.99
, pp. 1186-1189
-
-
Kora, Y.1
Nishihara, H.2
Inatomi, M.3
-
4
-
-
0026760736
-
Modified SRK formula for axial myopia (24.5 mm ≤ axial length < 27 mm)
-
Kora Y, Totsuka N, Fukado Y, et al: Modified SRK formula for axial myopia (24.5 mm ≤ axial length < 27 mm). Ophthalmic Surg 1992;23:603-607.
-
(1992)
Ophthalmic Surg
, vol.23
, pp. 603-607
-
-
Kora, Y.1
Totsuka, N.2
Fukado, Y.3
-
5
-
-
0025362280
-
A simple modified SRK formula for severely myopic eyes
-
Kora Y, Suzuki Y, Inatomi M, et al: A simple modified SRK formula for severely myopic eyes. Ophthalmic Surg 1990;21:266-271.
-
(1990)
Ophthalmic Surg
, vol.21
, pp. 266-271
-
-
Kora, Y.1
Suzuki, Y.2
Inatomi, M.3
-
7
-
-
0027442385
-
The Hoffer Q formula: A comparison of theoretic and regression formulas
-
Hoffer KJ: The Hoffer Q formula: A comparison of theoretic and regression formulas. J Cataract Refract Surg 1993;19:700-712.
-
(1993)
J Cataract Refract Surg
, vol.19
, pp. 700-712
-
-
Hoffer, K.J.1
-
9
-
-
0012793157
-
Biometry of human crystalline lens by image analysis
-
Shibata T, Hockwin O, Sasaki K, Sakamoto Y: Biometry of human crystalline lens by image analysis. J Eye 1985;2:113-115.
-
(1985)
J Eye
, vol.2
, pp. 113-115
-
-
Shibata, T.1
Hockwin, O.2
Sasaki, K.3
Sakamoto, Y.4
-
10
-
-
0015612084
-
The change in shape and internal form of the lens of the eye on accommodation
-
Brown N: The change in shape and internal form of the lens of the eye on accommodation. Exp Eye Res 1973;15:441-459.
-
(1973)
Exp Eye Res
, vol.15
, pp. 441-459
-
-
Brown, N.1
-
11
-
-
0026549374
-
Biometric constancy of the anterior eye segment as demonstrated by slit image photography according to the Scheimpflug principle
-
Olbert D, Kehrhahn O-H: Biometric constancy of the anterior eye segment as demonstrated by slit image photography according to the Scheimpflug principle. Ophthalmic Res 1992;24:27-31.
-
(1992)
Ophthalmic Res
, vol.24
, pp. 27-31
-
-
Olbert, D.1
Kehrhahn, O.-H.2
-
12
-
-
0033001090
-
An index for human lens transparency related to age and lens layer: Comparison between normal volunteers and diabetic patients with still clear lens
-
Sasaki H, Hockwin O, Kasuga T, et al: An index for human lens transparency related to age and lens layer: Comparison between normal volunteers and diabetic patients with still clear lens. Ophthalmic Res 1999;31:93-103.
-
(1999)
Ophthalmic Res
, vol.31
, pp. 93-103
-
-
Sasaki, H.1
Hockwin, O.2
Kasuga, T.3
-
13
-
-
0026997738
-
Prediction of pseudophakic AC depth with the newer IOL calculation formula
-
Olsen T, Olsen H, Thim K, Corydon L: Prediction of pseudophakic AC depth with the newer IOL calculation formula. J Cataract Refract Surg 1992;18:280-285.
-
(1992)
J Cataract Refract Surg
, vol.18
, pp. 280-285
-
-
Olsen, T.1
Olsen, H.2
Thim, K.3
Corydon, L.4
-
14
-
-
0012870211
-
Calculation of the postoperative pseudophakic AC depth of the IOL using pre-operative position of the lens capsules
-
Nezu N: Calculation of the postoperative pseudophakic AC depth of the IOL using pre-operative position of the lens capsules. IOL RS 1998;12:44-47.
-
(1998)
IOL RS
, vol.12
, pp. 44-47
-
-
Nezu, N.1
-
15
-
-
0025302581
-
Biometry of the posterior lens capsule: A new method to predict pseudophakic AC depth
-
Naeser K, Boberg-Ans J, Bargum R: Biometry of the posterior lens capsule: A new method to predict pseudophakic AC depth. J Cataract Refract Surg 1990;16:202-206.
-
(1990)
J Cataract Refract Surg
, vol.16
, pp. 202-206
-
-
Naeser, K.1
Boberg-Ans, J.2
Bargum, R.3
-
16
-
-
0031004725
-
Prediction of IOL power using the lens haptic plane concept
-
Norrby NES, Koranyi G: Prediction of IOL power using the lens haptic plane concept. J Cataract Refract Surg 1997;23:254-259.
-
(1997)
J Cataract Refract Surg
, vol.23
, pp. 254-259
-
-
Norrby, N.E.S.1
Koranyi, G.2
|