메뉴 건너뛰기




Volumn 26 IV, Issue , 2004, Pages 2738-2741

Active tremor compensation in microsurgery

Author keywords

Control system; Inertial sensing; Medical robotics; Microsurgery; Tremor

Indexed keywords

ACCELEROMETERS; CONTROL SYSTEMS; HYSTERESIS; INTELLIGENT AGENTS; KALMAN FILTERING; REAL TIME SYSTEMS; ROBOTICS; SENSORS; SIGNAL TO NOISE RATIO;

EID: 11144324378     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (54)

References (19)
  • 1
    • 0017664362 scopus 로고
    • Ergonomics applied to the practice of microsurgery
    • M. Patkin, Ergonomics applied to the practice of microsurgery. Austr. N. Z. J. Surg. 47:320-239, 1977.
    • (1977) Austr. N. Z. J. Surg. , vol.47 , pp. 320-1239
    • Patkin, M.1
  • 2
    • 0021045191 scopus 로고
    • Physiologic tremor and microsurgery
    • R. C. Harwell and R. L. Ferguson, "Physiologic tremor and microsurgery," Microsurgery, vol. 4, pp. 187-192, 1983.
    • (1983) Microsurgery , vol.4 , pp. 187-192
    • Harwell, R.C.1    Ferguson, R.L.2
  • 6
    • 0033989115 scopus 로고    scopus 로고
    • A study of surgical approaches to retinal vascular occlusions
    • W. M. Tang and D.P. Han, "A study of surgical approaches to retinal vascular occlusions." Arch. Ophthalmol. 118:138-43, 2000.
    • (2000) Arch. Ophthalmol. , vol.118 , pp. 138-143
    • Tang, W.M.1    Han, D.P.2
  • 7
    • 0031822358 scopus 로고    scopus 로고
    • Treatment of central retinal vein occlusion by injection of tissue plasminogen activator into a retinal vein
    • J. N. Weiss, "Treatment of central retinal vein occlusion by injection of tissue plasminogen activator into a retinal vein," Am. J. Ophthalmol. 126:142-144, 1998.
    • (1998) Am. J. Ophthalmol. , vol.126 , pp. 142-144
    • Weiss, J.N.1
  • 8
    • 0029842865 scopus 로고    scopus 로고
    • Prevalence and associations of retinal vein occlusion in Australia: The blue mountains eye study
    • P. Mitchell, W. Smith, and A. Chang, "Prevalence and associations of retinal vein occlusion in Australia: the Blue Mountains Eye Study," Arch. Ophthalmol., vol. 114, pp. 1243-1247, 1996.
    • (1996) Arch. Ophthalmol. , vol.114 , pp. 1243-1247
    • Mitchell, P.1    Smith, W.2    Chang, A.3
  • 9
    • 0030892229 scopus 로고    scopus 로고
    • Quantitative measurement of the effects of caffeine and propranolol on surgeon hand tremor
    • Mar.
    • M. U. Humayun, R. S. Rader, D. J. Pieramici, C. C. Awh, E. de Juan, Jr., "Quantitative measurement of the effects of caffeine and propranolol on surgeon hand tremor," Arch. Ophthalmol., vol. 115, pp. 371-374, Mar. 1997.
    • (1997) Arch. Ophthalmol. , vol.115 , pp. 371-374
    • Humayun, M.U.1    Rader, R.S.2    Pieramici, D.J.3    Awh, C.C.4    De Juan Jr., E.5
  • 13
    • 0032801309 scopus 로고    scopus 로고
    • Evaluation of a telerobotic system to assist surgeons in microsurgery
    • H. Das, H. Zak, J. Johnson, J. Crouch, and D. Frambach, "Evaluation of a telerobotic system to assist surgeons in microsurgery," Computer Aided Surg., vol. 4, pp. 15-25, 1999.
    • (1999) Computer Aided Surg. , vol.4 , pp. 15-25
    • Das, H.1    Zak, H.2    Johnson, J.3    Crouch, J.4    Frambach, D.5
  • 15
    • 0344877307 scopus 로고    scopus 로고
    • Design of all-accelerometer inertial measurement unit for tremor sensing in hand-held microsurgical instrument
    • May
    • W. T. Ang, P. K. Khosla, and C. N. Riviere, "Design of All-Accelerometer Inertial Measurement Unit for Tremor Sensing in Hand-held Microsurgical Instrument", Proc. International Conference on Robotics and Automation, May 2003, pp.1781-1786.
    • (2003) Proc. International Conference on Robotics and Automation , pp. 1781-1786
    • Ang, W.T.1    Khosla, P.K.2    Riviere, C.N.3
  • 16
  • 17
    • 0032126585 scopus 로고    scopus 로고
    • Adaptive canceling of physiological tremor for improved precision in microsurgery
    • C. N. Riviere, R. S. Rader, and N. V. Thakor, "Adaptive canceling of physiological tremor for improved precision in microsurgery," IEEE Trans. Biomed. Eng., vol. 45, pp. 839-846, 1998.
    • (1998) IEEE Trans. Biomed. Eng. , vol.45 , pp. 839-846
    • Riviere, C.N.1    Rader, R.S.2    Thakor, N.V.3
  • 18
    • 11144324514 scopus 로고    scopus 로고
    • Inverse feedforward controller with rate-dependent hysteresis model for piezoelectric actuators
    • Submitted to
    • W. T. Ang, P. K. Khosla, and C. N. Riviere, "Inverse Feedforward Controller with Rate-dependent Hysteresis Model for Piezoelectric Actuators", Submitted to IEEE Trans Control Systems & Tech.
    • IEEE Trans Control Systems & Tech.
    • Ang, W.T.1    Khosla, P.K.2    Riviere, C.N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.