메뉴 건너뛰기




Volumn 14, Issue 1, 2004, Pages 38-48

Three-dimensional interconnect technology on a flexible polyimide film

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL RESISTANCE; ELECTROLESS PLATING; ETCHING; EVAPORATION; MICROELECTROMECHANICAL DEVICES; SEMICONDUCTOR DEVICE MANUFACTURE; SPECIFIC HEAT OF SOLIDS; TEMPERATURE; THERMODYNAMIC PROPERTIES; THICKNESS MEASUREMENT; THIN FILM DEVICES; THREE DIMENSIONAL;

EID: 0942268412     PISSN: 09601317     EISSN: None     Source Type: Journal    
DOI: 10.1088/0960-1317/14/1/306     Document Type: Article
Times cited : (27)

References (11)
  • 2
    • 0033888145 scopus 로고    scopus 로고
    • A flexible micromachine-based shear-stress sensor array and its application to separation-point detection
    • Jiang F, Lee G-B, Tai Y-C and Ho C-M 2000 A flexible micromachine-based shear-stress sensor array and its application to separation-point detection Sensors Actuators A 79 194-203
    • (2000) Sensors Actuators A , vol.79 , pp. 194-203
    • Jiang, F.1    Lee, G.-B.2    Tai, Y.-C.3    Ho, C.-M.4
  • 3
    • 0343852697 scopus 로고    scopus 로고
    • A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues
    • Gonzalez C and Rodriguez M 1997 A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues J. Neurosci. Methods 72 189-95
    • (1997) J. Neurosci. Methods , vol.72 , pp. 189-195
    • Gonzalez, C.1    Rodriguez, M.2
  • 4
    • 0000215292 scopus 로고    scopus 로고
    • Flexible biomedical microdevices with double-sided electrode arrangements for neural applications
    • Stieglitz T 2001 Flexible biomedical microdevices with double-sided electrode arrangements for neural applications Sensors Actuators A 90 203-11
    • (2001) Sensors Actuators A , vol.90 , pp. 203-211
    • Stieglitz, T.1
  • 5
    • 0037086015 scopus 로고    scopus 로고
    • Flexible BIOMEMS with electrode arrangements on front and back side key component in neural prostheses and biohybrid systems
    • Stieglitz T and Gross M 2002 Flexible BIOMEMS with electrode arrangements on front and back side key component in neural prostheses and biohybrid systems Sensors Actuators B 83 8-14
    • (2002) Sensors Actuators B , vol.83 , pp. 8-14
    • Stieglitz, T.1    Gross, M.2
  • 6
    • 0942281270 scopus 로고    scopus 로고
    • http://www.kapton-dupont.com
  • 7
    • 0942292231 scopus 로고    scopus 로고
    • Catalogue, Kapton Polyimide film, Du Pont-Toray Co., Ltd, Japan
    • Catalogue, Kapton Polyimide film, Du Pont-Toray Co., Ltd, Japan
  • 8
    • 0942302905 scopus 로고    scopus 로고
    • http://www.ube-ind.co.jp
  • 9
    • 0942292226 scopus 로고    scopus 로고
    • Catalogue, Upilex Polyimide film, Ube Industries, Ltd, Japan
    • Catalogue, Upilex Polyimide film, Ube Industries, Ltd, Japan
  • 10
    • 0001448482 scopus 로고    scopus 로고
    • Study of wet treatment of polyimide by sum-frequency vibrational spectroscopy
    • Kim D and Shen Y R 1999 Study of wet treatment of polyimide by sum-frequency vibrational spectroscopy Appl. Phys. Lett. 74 3314-16
    • (1999) Appl. Phys. Lett. , vol.74 , pp. 3314-3316
    • Kim, D.1    Shen, Y.R.2
  • 11
    • 0037103983 scopus 로고    scopus 로고
    • Fabrication of thermal-isolation structure for microheater elements applicable to fingerprint sensors
    • Han J-S, Kadowaki T, Sato K and Shikida M 2002 Fabrication of thermal-isolation structure for microheater elements applicable to fingerprint sensors Sensors Actuators A 100 114-222
    • (2002) Sensors Actuators A , vol.100 , pp. 114-222
    • Han, J.-S.1    Kadowaki, T.2    Sato, K.3    Shikida, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.