메뉴 건너뛰기




Volumn 72, Issue 2, 1997, Pages 189-195

A flexible, perforated microelectrode array probe for action potential recording in nerve and muscle tissues

Author keywords

Action potential; Microelectrode probe; Muscle; Nerve

Indexed keywords

ACTION POTENTIAL; ANIMAL EXPERIMENT; ARTICLE; CONTROLLED STUDY; ELECTROPHYSIOLOGY; MICROELECTRODE; MUSCLE; NERVE; NONHUMAN; PRIORITY JOURNAL; RAT;

EID: 0343852697     PISSN: 01650270     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0165-0270(96)02202-9     Document Type: Article
Times cited : (56)

References (21)
  • 2
    • 0025723463 scopus 로고
    • The spectrum of the fiber loss in a model of neuropathic pain in the rat: an electron microscope study
    • Babaum, A.I., Gautron, M., Jazat, F., Mayes, M. and Guilbaud, G. (1991) The spectrum of the fiber loss in a model of neuropathic pain in the rat: an electron microscope study, Pain, 47: 359-367.
    • (1991) Pain , vol.47 , pp. 359-367
    • Babaum, A.I.1    Gautron, M.2    Jazat, F.3    Mayes, M.4    Guilbaud, G.5
  • 3
    • 0022559397 scopus 로고
    • Solid-state electrodes for multichannel multiplexed intracortical neuronal recording
    • BeMent, S.L., Wise, K.S., Anderson, D.J., Najafi, K. and Drake, K.L. (1986) Solid-state electrodes for multichannel multiplexed intracortical neuronal recording, IEEE Trans. Biomed. Eng., 33: 230-241.
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , pp. 230-241
    • Bement, S.L.1    Wise, K.S.2    Anderson, D.J.3    Najafi, K.4    Drake, K.L.5
  • 4
    • 0026603381 scopus 로고
    • A flexible perforated microelectrode array for extended neuronal recordings
    • Boppart, S.A., Wheeler, B.C. and Wallace, C.S. (1992) A flexible perforated microelectrode array for extended neuronal recordings, IEEE Trans. Biomed. Eng., 39: 37-42.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 37-42
    • Boppart, S.A.1    Wheeler, B.C.2    Wallace, C.S.3
  • 5
    • 0022559401 scopus 로고
    • The packaging of implantable integrated sensors
    • Bowman, L. and Meindl, J.D. (1986) The packaging of implantable integrated sensors, IEEE Trans. Biomed. Eng., 33: 248-255.
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , pp. 248-255
    • Bowman, L.1    Meindl, J.D.2
  • 6
    • 0026205082 scopus 로고
    • A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array
    • Campbell, P.K., Jones, K.E., Huber, R.J., Horch, K.W. and Normann, R.A. (1991) A silicon-based, three-dimensional neural interface: manufacturing processes for an intracortical electrode array. IEEE Trans. Biomed. Eng., 38: 758-768.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 7
    • 0022559394 scopus 로고
    • A peripheral nerve information transducer for amputees: long-term multichannel recordings from rabbit peripheral nerves
    • Edell, D.J. (1986) A peripheral nerve information transducer for amputees: long-term multichannel recordings from rabbit peripheral nerves, IEEE Trans. Biomed. Eng., 33: 203-214.
    • (1986) IEEE Trans. Biomed. Eng. , vol.33 , pp. 203-214
    • Edell, D.J.1
  • 8
    • 0024528092 scopus 로고
    • De- And regeneration of axons after minor lesions in the rat sciatic nerve. Effects of microneurography electrode penetrations
    • Fried, K., Frisén, J. and Mozart, M. (1989) De- and regeneration of axons after minor lesions in the rat sciatic nerve. Effects of microneurography electrode penetrations, Pain, 36: 93-102.
    • (1989) Pain , vol.36 , pp. 93-102
    • Fried, K.1    Frisén, J.2    Mozart, M.3
  • 9
    • 0020715238 scopus 로고
    • Packaging materials and techniques for implantable instruments
    • March 1983
    • Ko, W.H. and Spear, T.M. (1983) Packaging materials and techniques for implantable instruments. Engineering in Medicine and Biological Magazine, March 1983, pp. 24-38.
    • (1983) Engineering in Medicine and Biological Magazine , pp. 24-38
    • Ko, W.H.1    Spear, T.M.2
  • 10
    • 0343574970 scopus 로고
    • Advancing step by step
    • October:
    • Kobetic R. (1994) Advancing step by step, IEEE Spectrum. October: 27-31.
    • (1994) IEEE Spectrum , pp. 27-31
    • Kobetic, R.1
  • 11
    • 0026926772 scopus 로고
    • Regeneration microelectrode array for peripheral nerve recording and stimulation
    • Kovacs, G.T.A., Storment, C.W. and Rosen, J.M. (1992) Regeneration microelectrode array for peripheral nerve recording and stimulation, IEEE Trans. Biomed. Eng., 39: 893-902.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 893-902
    • Kovacs, G.T.A.1    Storment, C.W.2    Rosen, J.M.3
  • 12
    • 0019393971 scopus 로고
    • A practical 24 channel microelectrode for neural recording in vivo
    • Kuperstein, M. and Whittington, D.A. (1981) A practical 24 channel microelectrode for neural recording in vivo, IEEE Trans. Biomed. Eng., 28: 288-293.
    • (1981) IEEE Trans. Biomed. Eng. , vol.28 , pp. 288-293
    • Kuperstein, M.1    Whittington, D.A.2
  • 13
    • 0015388162 scopus 로고
    • Glass-coated platinum-plated tungsten microelectrodes
    • Merrill, E.G. and Ainsworth, A. (1972) Glass-coated platinum-plated tungsten microelectrodes, Med. Biol. Eng., 10: 662-672.
    • (1972) Med. Biol. Eng. , vol.10 , pp. 662-672
    • Merrill, E.G.1    Ainsworth, A.2
  • 14
    • 0002734734 scopus 로고
    • Extracellular single and multiple unit recording with microelectrodes
    • In Stamford J.A. (Ed.), Oxford University Press, Oxford.
    • Millar, J. (1992) Extracellular single and multiple unit recording with microelectrodes. In Stamford J.A. (Ed.), Monitoring Neuronal Activity, Oxford University Press, Oxford.
    • (1992) Monitoring Neuronal Activity
    • Millar, J.1
  • 15
    • 0018428008 scopus 로고
    • Experimental studies on the effects of tension on intraneural microcirculation in sutured peripheral nerves
    • Miyamoto, Y., Showichi, M.D. and Tsuge, K. (1979) Experimental studies on the effects of tension on intraneural microcirculation in sutured peripheral nerves, Plast. Reconstr. Surg., 63: 398-403.
    • (1979) Plast. Reconstr. Surg. , vol.63 , pp. 398-403
    • Miyamoto, Y.1    Showichi, M.D.2    Tsuge, K.3
  • 16
    • 0022863439 scopus 로고    scopus 로고
    • An implantable multielectrode array with on-chip signal processing
    • Najafi, K. and Wise, K.S. An implantable multielectrode array with on-chip signal processing, IEEE J. Solid State Circuits, 21: 1035-1044.
    • IEEE J. Solid State Circuits , vol.21 , pp. 1035-1044
    • Najafi, K.1    Wise, K.S.2
  • 17
    • 0018574732 scopus 로고
    • A review of printed circuit microelectrodes and their production
    • Pickard, R.S. (1979) A review of printed circuit microelectrodes and their production, J. Neurosci. Methods, 1: 301-318.
    • (1979) J. Neurosci. Methods , vol.1 , pp. 301-318
    • Pickard, R.S.1
  • 18
  • 20
    • 0016499925 scopus 로고    scopus 로고
    • A low-capacitance multielectrode probe for use in extracellular neurophysiology
    • Wise, K.S. and Angell, J.B. A low-capacitance multielectrode probe for use in extracellular neurophysiology, IEEE Trans. Biomed. Eng., 22: 212-219.
    • IEEE Trans. Biomed. Eng. , vol.22 , pp. 212-219
    • Wise, K.S.1    Angell, J.B.2
  • 21
    • 0014816457 scopus 로고
    • An integrated-circuit approach to extracellular microelectrodes
    • Wise, K.S., Angell, J.B. and Starr, A. (1970) An integrated-circuit approach to extracellular microelectrodes, IEEE Trans. Biomed. Eng., 17: 238-247.
    • (1970) IEEE Trans. Biomed. Eng. , vol.17 , pp. 238-247
    • Wise, K.S.1    Angell, J.B.2    Starr, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.