Volumn 63, Issue 5, 2002, Pages 492-500

Deconvolution of surface topology for quantification of initial wear in highly cross-linked acetabular components for THA

Author keywords

Acetabular component; Cross linking; Roughness; Surface topology; Total hip replacement; Ultra high molecular weight polyethylene (UHMWPE); Waviness; Wear

Indexed keywords

ALGORITHMS; FOURIER TRANSFORMS; IMPLANTS (SURGICAL); ORTHOPEDICS; SURFACE TOPOGRAPHY; WEAR OF MATERIALS;

EID: 0036380423     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.10309     Document Type: Article
Times cited : (16)

References (30)
  • 1
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz SM, Muratoglu OK, Evans M, Edidin AA. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999;20:1659-1688.
    • (1999) Biomaterials , vol.20 , pp. 1659-1688
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3    Edidin, A.A.4
  • 2
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 1999;17:157-167.
    • (1999) J Orthop Res , vol.17 , pp. 157-167
    • McKellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 3
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty 2001;16:149-160.
    • (2001) J Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 4
    • 0031594091 scopus 로고    scopus 로고
    • Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
    • Wang A, Essner A, Polineni VK, Stark C, Dumbleton JH. Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements. Tribiol Int 1998;31:17-33.
    • (1998) Tribiol Int , vol.31 , pp. 17-33
    • Wang, A.1    Essner, A.2    Polineni, V.K.3    Stark, C.4    Dumbleton, J.H.5
  • 5
    • 0031686833 scopus 로고    scopus 로고
    • The multifactorial nature of polyethylene wear in vivo
    • discussion 1242-1243
    • Schmalzried TP, Dorey FJ, McKellop H. The multifactorial nature of polyethylene wear in vivo. J Bone Joint Surg Am 1998;80:1234-1242; discussion 1242-1243.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1234-1242
    • Schmalzried, T.P.1    Dorey, F.J.2    McKellop, H.3
  • 6
    • 0008291702 scopus 로고    scopus 로고
    • Predicting the clinical wear performance of orthopaedic bearing surfaces
    • Jacobs JJ, Craig TL, editors. West Conshohoken, PA: American Society for Testing and Materials
    • Sauer WL, Anthony ME. Predicting the clinical wear performance of orthopaedic bearing surfaces. Jacobs JJ, Craig TL, editors. Alternative bearing surfaces in total joint replacement. West Conshohoken, PA: American Society for Testing and Materials; 1998. p 1-29.
    • (1998) Alternative bearing surfaces in total joint replacement , pp. 1-29
    • Sauer, W.L.1    Anthony, M.E.2
  • 7
    • 0002832757 scopus 로고    scopus 로고
    • Wear assessment
    • JJ Callaghan, AG Rosenberg and HE Rubash, JJ Callaghan, AG Rosenberg and HE Rubashs. Philadelphia: Lippincott-Raven
    • McKellop HA. Wear assessment. JJ Callaghan, AG Rosenberg and HE Rubash, JJ Callaghan, AG Rosenberg and HE Rubashs. The adult hip. Philadelphia: Lippincott-Raven; 1998. pp 231-246.
    • (1998) The adult hip , pp. 231-246
    • McKellop, H.A.1
  • 8
    • 0016823891 scopus 로고
    • Rate of wear in total hip replacement
    • Charnley J, Halley DK. Rate of wear in total hip replacement. Clin Orthop 1975:170-179.
    • (1975) Clin Orthop , pp. 170-179
    • Charnley, J.1    Halley, D.K.2
  • 9
    • 0028820598 scopus 로고
    • Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique
    • Devane PA, Bourne RB, Rorabeck CH, Hardie RM, Horne JG. Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique. Clin Orthop 1995:303-316.
    • (1995) Clin Orthop , pp. 303-316
    • Devane, P.A.1    Bourne, R.B.2    Rorabeck, C.H.3    Hardie, R.M.4    Horne, J.G.5
  • 10
    • 0030669292 scopus 로고    scopus 로고
    • Determination of polyethylene wear in total hip replacements with use of digital radiographs
    • Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am 1997;79:1635-1641.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1635-1641
    • Martell, J.M.1    Berdia, S.2
  • 11
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 1990;72:518-528.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 13
    • 0030903723 scopus 로고    scopus 로고
    • Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
    • Jasty M, Goetz DD, Bragdon CR, Lee KR, Hanson AE, Elder JR, Harris WH. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J Bone Joint Surg Am 1997;79:349-358.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 349-358
    • Jasty, M.1    Goetz, D.D.2    Bragdon, C.R.3    Lee, K.R.4    Hanson, A.E.5    Elder, J.R.6    Harris, W.H.7
  • 14
    • 0032818125 scopus 로고    scopus 로고
    • The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement
    • Elfick APD, Hall RM, Pinder IM, Unsworth A. The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement. J Biomed Mater Res Appl Biomat 1999;48:712-718.
    • (1999) J Biomed Mater Res Appl Biomat , vol.48 , pp. 712-718
    • Elfick, A.P.D.1    Hall, R.M.2    Pinder, I.M.3    Unsworth, A.4
  • 15
    • 0035482038 scopus 로고    scopus 로고
    • Mechanical behavior, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation
    • Edidin AA, Rimnac CM, Goldberg V, Kurtz SM. Mechanical behavior, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation. Wear 2001;250:152-158.
    • (2001) Wear , vol.250 , pp. 152-158
    • Edidin, A.A.1    Rimnac, C.M.2    Goldberg, V.3    Kurtz, S.M.4
  • 16
    • 0031855324 scopus 로고    scopus 로고
    • Examination of wear in Duraloc acetabular components: Two- to five-year evaluation of Hylamer and Enduron liners
    • Sychterz CJ, Shah N, Engh CA. Examination of wear in Duraloc acetabular components: Two- to five-year evaluation of Hylamer and Enduron liners. J Arthroplasty 1998;13:508-514.
    • (1998) J Arthroplasty , vol.13 , pp. 508-514
    • Sychterz, C.J.1    Shah, N.2    Engh, C.A.3
  • 17
    • 0035217940 scopus 로고    scopus 로고
    • Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept
    • Muratoglu OK, Bragdon CR, O'Connor D, Perinchief RS, Estok DM, 2nd, Jasty M, Harris WH. Larger diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept. J Arthroplasty 2001;16:24-30.
    • (2001) J Arthroplasty , vol.16 , pp. 24-30
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3    Perinchief, R.S.4    Estok D.M. II5    Jasty, M.6    Harris, W.H.7
  • 18
    • 0012403087 scopus 로고    scopus 로고
    • Alternative bearing surfaces in hip replacement
    • Sinha R, editor. New York: Marcel Dekker; in press
    • Muratoglu OK, Kurtz SM. Alternative bearing surfaces in hip replacement. In: Sinha R, editor. Current trends and controversies, 2002. New York: Marcel Dekker; in press.
    • (2002) Current trends and controversies
    • Muratoglu, O.K.1    Kurtz, S.M.2
  • 19
    • 0031256146 scopus 로고    scopus 로고
    • The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets
    • Hall RM, Siney P, Unsworth A, Wroblewski BM. The effect of surface topography of retrieved femoral heads on the wear of UHMWPE sockets. Med Eng Phys 1997;19:711-719.
    • (1997) Med Eng Phys , vol.19 , pp. 711-719
    • Hall, R.M.1    Siney, P.2    Unsworth, A.3    Wroblewski, B.M.4
  • 20
    • 84947353957 scopus 로고
    • Comparison of medical-grade ultrahigh molecular weight polyethylene microstructure by atomic force microscopy and transmission electron microscopy
    • Vallotton PH, Denn MM, Wood BA, Salmeron MB. Comparison of medical-grade ultrahigh molecular weight polyethylene microstructure by atomic force microscopy and transmission electron microscopy. J Biomater Sci Polym Ed 1994;6:609-620.
    • (1994) J Biomater Sci Polym Ed , vol.6 , pp. 609-620
    • Vallotton, P.H.1    Denn, M.M.2    Wood, B.A.3    Salmeron, M.B.4
  • 21
    • 0033800071 scopus 로고    scopus 로고
    • Surface morphology and wear mechanisms of four clinically relevant biomaterials after hip simulator testing
    • Kurtz SM, Muhlstein C, Edidin AA. Surface morphology and wear mechanisms of four clinically relevant biomaterials after hip simulator testing. J Biomed Mater Res 2000;52:447-459.
    • (2000) J Biomed Mater Res , vol.52 , pp. 447-459
    • Kurtz, S.M.1    Muhlstein, C.2    Edidin, A.A.3
  • 22
    • 0033179629 scopus 로고    scopus 로고
    • Radiation and peroxide crosslinking promote strain hardening behavior and molecular alignment in UHMWPE during multiaxial loading conditions
    • Kurtz SM, Pruitt LA, Jewett CW, Foulds JR, Edidin AA. Radiation and peroxide crosslinking promote strain hardening behavior and molecular alignment in UHMWPE during multiaxial loading conditions. Biomaterials 1999;20:1449-1462.
    • (1999) Biomaterials , vol.20 , pp. 1449-1462
    • Kurtz, S.M.1    Pruitt, L.A.2    Jewett, C.W.3    Foulds, J.R.4    Edidin, A.A.5
  • 24
    • 0033489876 scopus 로고    scopus 로고
    • Effects of machining on tribological behavior of ultra-high molecular weight polyethylene (UHMWPE) under dry reciprocating sliding
    • Song J, Liu P, Cremens M, Bonutti P. Effects of machining on tribological behavior of ultra-high molecular weight polyethylene (UHMWPE) under dry reciprocating sliding. Wear 1999;225-229:716-723.
    • (1999) Wear , vol.225-229 , pp. 716-723
    • Song, J.1    Liu, P.2    Cremens, M.3    Bonutti, P.4
  • 25
    • 0035124730 scopus 로고    scopus 로고
    • Comparative wear and wear debris under three different counterface conditions of crosslinked and noncrosslinked ultra high molecular weight polyethylene
    • Endo MM, Barbour PS, Barton DC, Fisher J, Tipper JL, Ingham E, Stone MH. Comparative wear and wear debris under three different counterface conditions of crosslinked and noncrosslinked ultra high molecular weight polyethylene. Biomed Mater Eng 2001;11:23-35.
    • (2001) Biomed Mater Eng , vol.11 , pp. 23-35
    • Endo, M.M.1    Barbour, P.S.2    Barton, D.C.3    Fisher, J.4    Tipper, J.L.5    Ingham, E.6    Stone, M.H.7
  • 26
    • 0032815159 scopus 로고    scopus 로고
    • A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene
    • Endo MM, Barbour PS, Barton DC, Wroblewski BM, Fisher J, Tipper JL, Ingham E, Stone MH. A comparison of the wear and debris generation of GUR 1120 (compression moulded) and GUR 4150HP (ram extruded) ultra high molecular weight polyethylene. Biomed Mater Eng 1999;9:113-124.
    • (1999) Biomed Mater Eng , vol.9 , pp. 113-124
    • Endo, M.M.1    Barbour, P.S.2    Barton, D.C.3    Wroblewski, B.M.4    Fisher, J.5    Tipper, J.L.6    Ingham, E.7    Stone, M.H.8
  • 27
    • 4244058623 scopus 로고    scopus 로고
    • Comparison of wear, wear debris, and functional biological activity of crosslinked and non crosslinked polyethylenes in hip prostheses
    • Tipper JL, Endo M, Stone MH, Ingham E, Fisher J. Comparison of wear, wear debris, and functional biological activity of crosslinked and non crosslinked polyethylenes in hip prostheses. Trans European Soc Biomaterials 2001:T43.
    • (2001) Trans European Soc Biomaterials
    • Tipper, J.L.1    Endo, M.2    Stone, M.H.3    Ingham, E.4    Fisher, J.5
  • 28
    • 0037082747 scopus 로고    scopus 로고
    • Volumetric determination of wear of ceramics for hip joints
    • Serra E, Tucci A, Esposito L, Piconi C. Volumetric determination of wear of ceramics for hip joints. Biomaterials 2002;23:1131-1137.
    • (2002) Biomaterials , vol.23 , pp. 1131-1137
    • Serra, E.1    Tucci, A.2    Esposito, L.3    Piconi, C.4
  • 29
    • 0022107624 scopus 로고
    • The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
    • Bartel DL, Burstein AH, Toda MD, Edwards DL. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J Biomech Eng 1985;107:193-199.
    • (1985) J Biomech Eng , vol.107 , pp. 193-199
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 30
    • 0027575844 scopus 로고
    • Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene
    • Cooper JR, Dowson D, Fisher J. Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethylene. Wear 1993;162-164:378-384.
    • (1993) Wear , vol.162-164 , pp. 378-384
    • Cooper, J.R.1    Dowson, D.2    Fisher, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.