Defect initiation at subsurface grain boundary as a precursor of delamination in ultrahigh molecular weight polyethylene

Author keywords

Delamination; Gamma irradiation; Grain boundary; Subsurface defect; Ultrahigh molecular weight polyethylene

Indexed keywords

CRACK INITIATION; DEGRADATION; DELAMINATION; GRAIN BOUNDARIES; MOLECULAR WEIGHT; POLYETHYLENE GLYCOLS; SCANNING ELECTRON MICROSCOPY; SURFACE ROUGHNESS; VITAMINS;

EID: 0344738773     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.a.10133     Document Type: Article
Times cited : (28)

References (31)
  • 1
    • 0028129938 scopus 로고
    • Ultra-high molecular weight polyethylene. The material and its use in total joint implants
    • Li S, Burstein AH. Ultra-high molecular weight polyethylene. The material and its use in total joint implants. J Bone Joint Surg 1994;76-A:1080-1090.
    • (1994) J Bone Joint Surg , vol.76 A , pp. 1080-1090
    • Li, S.1    Burstein, A.H.2
  • 2
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz SM, Muratoglu OK, Evans M, Edidin AA. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999;20:1659-1688.
    • (1999) Biomaterials , vol.20 , pp. 1659-1688
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3    Edidin, A.A.4
  • 3
    • 0029693747 scopus 로고    scopus 로고
    • Factors influencing the longevity of UHMWPE tibial components
    • Heim CS, Postak PD, Greenwald AS. Factors influencing the longevity of UHMWPE tibial components. Instruc Course Lec 1996;45:303-312.
    • (1996) Instruc Course Lec , vol.45 , pp. 303-312
    • Heim, C.S.1    Postak, P.D.2    Greenwald, A.S.3
  • 6
    • 0026527293 scopus 로고
    • Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses
    • Engh GA, Dwyer KA, Hanes CK. Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg 1992;74-B:9-17.
    • (1992) J Bone Joint Surg , vol.74 B , pp. 9-17
    • Engh, G.A.1    Dwyer, K.A.2    Hanes, C.K.3
  • 7
    • 0030248625 scopus 로고    scopus 로고
    • Wear testing of materials and surfaces for total knee replacement
    • Walker PS, Blunn GW, Lilley PA. Wear testing of materials and surfaces for total knee replacement. J Biomed Mater Res 1996;33:159-175.
    • (1996) J Biomed Mater Res , vol.33 , pp. 159-175
    • Walker, P.S.1    Blunn, G.W.2    Lilley, P.A.3
  • 8
    • 0023697318 scopus 로고
    • Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses
    • Landy MM, Walker PS. Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses. J Arthroplasty 1988;3:S73-S85.
    • (1988) J Arthroplasty , vol.3
    • Landy, M.M.1    Walker, P.S.2
  • 9
    • 0023511578 scopus 로고
    • A histologic comparison of aseptic loosening of cemented, press-fit, and biologic ingrowth prostheses
    • Lennox DW, Schofield BH, McDonald DF, Riley LHJ. A histologic comparison of aseptic loosening of cemented, press-fit, and biologic ingrowth prostheses. Clin Orthop Rel Res 1987:171-191.
    • (1987) Clin Orthop Rel Res , pp. 171-191
    • Lennox, D.W.1    Schofield, B.H.2    McDonald, D.F.3    Riley, L.H.J.4
  • 10
    • 0023860303 scopus 로고
    • A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles
    • Howie DW, Vernon-Roberts B, Oakeshott R, Manthey B. A rat model of resorption of bone at the cement-bone interface in the presence of polyethylene wear particles. J Bone Joint Surg 1988;70-A:257-263.
    • (1988) J Bone Joint Surg , vol.70 A , pp. 257-263
    • Howie, D.W.1    Vernon-Roberts, B.2    Oakeshott, R.3    Manthey, B.4
  • 11
    • 0031105323 scopus 로고    scopus 로고
    • Polyethylene wear in total hip and knee arthroplasties
    • Lewis G. Polyethylene wear in total hip and knee arthroplasties. J Biomed Mater Res, Appl Biomater 1997;38:55-75.
    • (1997) J Biomed Mater Res, Appl Biomater , vol.38 , pp. 55-75
    • Lewis, G.1
  • 13
    • 0030271513 scopus 로고    scopus 로고
    • Fatigue performance of ultra-high-molecular-weight polyethylene: Effect of gamma radiation sterilization
    • Sauer WL, Weaver KD, Beals NB. Fatigue performance of ultra-high-molecular-weight polyethylene: Effect of gamma radiation sterilization. Biomaterials 1996;17:1929-1935.
    • (1996) Biomaterials , vol.17 , pp. 1929-1935
    • Sauer, W.L.1    Weaver, K.D.2    Beals, N.B.3
  • 14
    • 0031260268 scopus 로고    scopus 로고
    • Oxidation of ultra-high molecular weight polyethylene characterized by Fourier transform infrared spectrometry
    • Goldman M, Lee M, Gronsky R, Pruitt L. Oxidation of ultra-high molecular weight polyethylene characterized by Fourier transform infrared spectrometry. J Biomed Mater Res 1997;37:43-50.
    • (1997) J Biomed Mater Res , vol.37 , pp. 43-50
    • Goldman, M.1    Lee, M.2    Gronsky, R.3    Pruitt, L.4
  • 15
    • 0032486507 scopus 로고    scopus 로고
    • Comparison of the effects of gamma radiation and low temperature hydrogen peroxide gas plasma sterilization on the molecular structure, fatigue resistance, and wear behavior of UHMWPE
    • Goldman M, Pruitt L. Comparison of the effects of gamma radiation and low temperature hydrogen peroxide gas plasma sterilization on the molecular structure, fatigue resistance, and wear behavior of UHMWPE. J Biomed Mater Res 1998;40:378-384.
    • (1998) J Biomed Mater Res , vol.40 , pp. 378-384
    • Goldman, M.1    Pruitt, L.2
  • 16
    • 0344662090 scopus 로고    scopus 로고
    • In-vivo change in micromechanical properties of vitamin E-added UHMWPE
    • in Japanese
    • Hiyoshi N, Ishimoto Y, Tamai S. In-vivo change in micromechanical properties of vitamin E-added UHMWPE. J Jpn Soc Clin Biomech 2000;21:361-364 (in Japanese).
    • (2000) J Jpn Soc Clin Biomech , vol.21 , pp. 361-364
    • Hiyoshi, N.1    Ishimoto, Y.2    Tamai, S.3
  • 17
    • 0028102058 scopus 로고
    • Post-irradiation aging of ultra-high molecular weight polyethylene
    • Rimnac CM, Klein RW, Betts F, Wright TM. Post-irradiation aging of ultra-high molecular weight polyethylene. J Bone Joint Surg 1994;76-A:1052-1056.
    • (1994) J Bone Joint Surg , vol.76 A , pp. 1052-1056
    • Rimnac, C.M.1    Klein, R.W.2    Betts, F.3    Wright, T.M.4
  • 18
    • 0032772735 scopus 로고    scopus 로고
    • Prevention of fatigue cracks in ultrahigh molecular weight polyethylene joint components by the addition of vitamin E
    • Tomita N, Kitakura T, Onmori N, Ikada Y, Aoyama E. Prevention of fatigue cracks in ultrahigh molecular weight polyethylene joint components by the addition of vitamin E. J Biomed Mater Res 1999;48:474-478.
    • (1999) J Biomed Mater Res , vol.48 , pp. 474-478
    • Tomita, N.1    Kitakura, T.2    Onmori, N.3    Ikada, Y.4    Aoyama, E.5
  • 19
    • 0032986185 scopus 로고    scopus 로고
    • Effect of sliding locus on subsurface crack formation in ultra-high-molecular-weight polyethylene knee component
    • Todo S, Tomita N, Kitakura T, Yamano Y. Effect of sliding locus on subsurface crack formation in ultra-high-molecular-weight polyethylene knee component. Bio-Med Mater Eng 1999;9:13-20.
    • (1999) Bio-Med Mater Eng , vol.9 , pp. 13-20
    • Todo, S.1    Tomita, N.2    Kitakura, T.3    Yamano, Y.4
  • 21
    • 0030152397 scopus 로고    scopus 로고
    • Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions
    • Wang A, Essner A, Stark C, Dumbleton JH. Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions. Biomaterials 1996;17:865-871.
    • (1996) Biomaterials , vol.17 , pp. 865-871
    • Wang, A.1    Essner, A.2    Stark, C.3    Dumbleton, J.H.4
  • 22
    • 0034507657 scopus 로고    scopus 로고
    • Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations
    • Bell J, Besong AA, Tipper JL. Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations. Proc Inst Mech Eng [H]. 2000;214:513-518.
    • (2000) Proc Inst Mech Eng [H] , vol.214 , pp. 513-518
    • Bell, J.1    Besong, A.A.2    Tipper, J.L.3
  • 23
    • 0030342777 scopus 로고    scopus 로고
    • An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact
    • Ohashi M, Tomita N, Ikada Y, Ikeuchi K, Motoike T. An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact. Bio-Med Mater Eng 1996;6:441-451.
    • (1996) Bio-Med Mater Eng , vol.6 , pp. 441-451
    • Ohashi, M.1    Tomita, N.2    Ikada, Y.3    Ikeuchi, K.4    Motoike, T.5
  • 27
    • 0345524511 scopus 로고    scopus 로고
    • Effect of gamma-irradiated degradation on delamination of UHMWPE
    • Shibata N, Tomita N, Ikeuchi K. Effect of gamma-irradiated degradation on delamination of UHMWPE. J Jpn Soc Clin Biomech 2002;23:367-371.
    • (2002) J Jpn Soc Clin Biomech , vol.23 , pp. 367-371
    • Shibata, N.1    Tomita, N.2    Ikeuchi, K.3
  • 28
    • 0037222679 scopus 로고    scopus 로고
    • Gamma-irradiation aggravates stress concentration along subsurface grain boundary of ultra-high molecular weight polyethylene (UHMWPE) under sliding fatigue environment
    • Shibata N, Tomita N, Ikeuchi K. Gamma-irradiation aggravates stress concentration along subsurface grain boundary of ultra-high molecular weight polyethylene (UHMWPE) under sliding fatigue environment. Bio-Med Mater Eng 2003;13:35-45.
    • (2003) Bio-Med Mater Eng , vol.13 , pp. 35-45
    • Shibata, N.1    Tomita, N.2    Ikeuchi, K.3
  • 29
    • 0027703214 scopus 로고
    • Contact mechanics of ultra-high-molecular-weight polyethylene for artificial knee joint
    • in Japanese
    • Fujiki H, Ishikawa H, Yasuda K. Contact mechanics of ultra-high-molecular-weight polyethylene for artificial knee joint. Trans Jpn Soc Mech Eng 1993;59-A:2800-2807 (in Japanese).
    • (1993) Trans Jpn Soc Mech Eng , vol.59 A , pp. 2800-2807
    • Fujiki, H.1    Ishikawa, H.2    Yasuda, K.3
  • 30
    • 0030220033 scopus 로고    scopus 로고
    • Contact analysis of ultra-high molecular weight polyethylene articular plate in artificial knee joint during gait movement
    • Ishikawa H, Fujiki H, Yasuda K. Contact analysis of ultra-high molecular weight polyethylene articular plate in artificial knee joint during gait movement. J Biomech Eng 1996;118:377-386.
    • (1996) J Biomech Eng , vol.118 , pp. 377-386
    • Ishikawa, H.1    Fujiki, H.2    Yasuda, K.3
  • 31


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.