1
-
-
0020826593
-
Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prostheses
-
Hood RW, Wright TM, Burstein AH: Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res 17:829, 1983
-
(1983)
J Biomed Mater Res
, vol.17
, pp. 829
-
-
Hood, R.W.1
Wright, T.M.2
Burstein, A.H.3
-
2
-
-
0023007566
-
The effect of conformity, thickness and material on stresses in ultrahigh molecular weight components for total joint replacement
-
Bartel DL, Bicknell VL, Wright TM: The effect of conformity, thickness and material on stresses in ultrahigh molecular weight components for total joint replacement. J Bone Joint Surg 68A:1041, 1986
-
(1986)
J Bone Joint Surg
, vol.68 A
, pp. 1041
-
-
Bartel, D.L.1
Bicknell, V.L.2
Wright, T.M.3
-
3
-
-
0022504260
-
The problem of surface damage in polyethylene total knee components
-
Wright TM, Bartel DL: The problem of surface damage in polyethylene total knee components. Clin Orthop 205:67, 1986
-
(1986)
Clin Orthop
, vol.205
, pp. 67
-
-
Wright, T.M.1
Bartel, D.L.2
-
4
-
-
0026346472
-
Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
-
Collier JP, Mayor MB, McNamara JL et al: Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin Orthop 273: 232, 1991
-
(1991)
Clin Orthop
, vol.273
, pp. 232
-
-
Collier, J.P.1
Mayor, M.B.2
McNamara, J.L.3
-
6
-
-
0028009147
-
A comparison of contact pressures in tibial and patellar total knee components before and after service in vivo
-
McNamara JL, Collier JP, Mayor MB, Jensen RE: A comparison of contact pressures in tibial and patellar total knee components before and after service in vivo. Clin Orthop 299:104, 1994
-
(1994)
Clin Orthop
, vol.299
, pp. 104
-
-
McNamara, J.L.1
Collier, J.P.2
Mayor, M.B.3
Jensen, R.E.4
-
7
-
-
0028047233
-
The correlation between fusion defects and damage in tibial polyethylene bearings
-
Wrona M, Mayor MB, Collier JP, Jensen RE: The correlation between fusion defects and damage in tibial polyethylene bearings. Clin Orthop 299:92, 1994
-
(1994)
Clin Orthop
, vol.299
, pp. 92
-
-
Wrona, M.1
Mayor, M.B.2
Collier, J.P.3
Jensen, R.E.4
-
8
-
-
0018611372
-
On the origins of high in vivo wear rates in polyethylene components of total joint prostheses
-
Rose RM, Crugnola A, Ries M et al: On the origins of high in vivo wear rates in polyethylene components of total joint prostheses. Clin Orthop 145:277, 1979
-
(1979)
Clin Orthop
, vol.145
, pp. 277
-
-
Rose, R.M.1
Crugnola, A.2
Ries, M.3
-
9
-
-
0023697318
-
Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses
-
Landy MM, Walker PS: Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses. J Arthroplasty 5(suppl): S73, 1988
-
(1988)
J Arthroplasty
, vol.5
, Issue.SUPPL.
-
-
Landy, M.M.1
Walker, P.S.2
-
10
-
-
0028129938
-
Current concepts review ultrahigh molecular weight polyethylene
-
Li S, Burstein AH: Current concepts review ultrahigh molecular weight polyethylene. J Bone Joint Surg 76A:1080, 1994
-
(1994)
J Bone Joint Surg
, vol.76 A
, pp. 1080
-
-
Li, S.1
Burstein, A.H.2
-
11
-
-
85030203278
-
-
ME Thesis, Thayer School of Engineering, Dartmouth College, Hanover, NH
-
Wrona M: An investigation into the relationship between wear damage and internal fusion defects in retrieved UHMWPE tibial and acetabular components. ME Thesis, Thayer School of Engineering, Dartmouth College, Hanover, NH, 1992
-
(1992)
An Investigation into the Relationship between Wear Damage and Internal Fusion Defects in Retrieved UHMWPE Tibial and Acetabular Components
-
-
Wrona, M.1
-
12
-
-
27044447668
-
Characterization and comparison of compression molded and machined UHMWPE components
-
New Orleans, LA, February
-
Sun DC, Stark C, Dumbleton JH: Characterization and comparison of compression molded and machined UHMWPE components. Presented at the 40th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, February 1994
-
(1994)
40th Annual Meeting of the Orthopaedic Research Society
-
-
Sun, D.C.1
Stark, C.2
Dumbleton, J.H.3
-
14
-
-
70350684695
-
Standard test method for tensile properties of plastics
-
ASTM Designation D638-91
-
ASTM Designation D638-91: Standard test method for tensile properties of plastics. Annual Book of ASTM Standards 8:52, 1994
-
(1994)
Annual Book of ASTM Standards
, vol.8
, pp. 52
-
-
-
15
-
-
0343318592
-
A fourier transform infrared technique for the evaluation of polyethylene orthopaedic bearing materials
-
Charleston, SC, May
-
Nagy EV, Li S: A fourier transform infrared technique for the evaluation of polyethylene orthopaedic bearing materials. Presented at the 16th Annual Meeting of the Society for Biomaterials, Charleston, SC, May 1990
-
(1990)
16th Annual Meeting of the Society for Biomaterials
-
-
Nagy, E.V.1
Li, S.2
-
16
-
-
0342962145
-
Effect of aging on ultra high molecular weight polyethylene
-
Shastri R, Grood ES, Roe RJ, Noyes FR: Effect of aging on ultra high molecular weight polyethylene. Plast Eng 39:33, 1983
-
(1983)
Plast Eng
, vol.39
, pp. 33
-
-
Shastri, R.1
Grood, E.S.2
Roe, R.J.3
Noyes, F.R.4
-
17
-
-
0022734967
-
The effect of sterilising radiation on the properties of ultra-high molecular weight polyethylene
-
Birkinshaw C, Buggy M, White JJ: The effect of sterilising radiation on the properties of ultra-high molecular weight polyethylene. Mater Chemistry Physics 14:549; 1986
-
(1986)
Mater Chemistry Physics
, vol.14
, pp. 549
-
-
Birkinshaw, C.1
Buggy, M.2
White, J.J.3
-
18
-
-
0023560964
-
Effects of radiation sterilization on UHMW-polyethylene
-
Los Angeles, CA, May
-
Kurth M, Eyerer P, Cui D: Effects of radiation sterilization on UHMW-polyethylene. Presented at the 45th Annual Technical Conference of the Society of Plastics Engineers, Los Angeles, CA, May 1987
-
(1987)
45th Annual Technical Conference of the Society of Plastics Engineers
-
-
Kurth, M.1
Eyerer, P.2
Cui, D.3
-
20
-
-
0024174065
-
Ionizing irradiation for sterilization and modification of high molecular weight polyethylenes
-
Streicher RM: Ionizing irradiation for sterilization and modification of high molecular weight polyethylenes. Plast Rubber Processing Applications 10:221, 1988
-
(1988)
Plast Rubber Processing Applications
, vol.10
, pp. 221
-
-
Streicher, R.M.1
-
21
-
-
0028102058
-
Post-irradiation aging of ultra-high molecular weight polyethylene
-
Rimnac CM, Klein RW, Betts F, Wright TM: Post-irradiation aging of ultra-high molecular weight polyethylene. J Bone Joint Surg 76A:1052, 1994
-
(1994)
J Bone Joint Surg
, vol.76 A
, pp. 1052
-
-
Rimnac, C.M.1
Klein, R.W.2
Betts, F.3
Wright, T.M.4
-
22
-
-
0002738931
-
Oxidation versus depth and time for polyethylene gamma sterilized in air
-
New Orleans, LA, February
-
Saum K A: Oxidation versus depth and time for polyethylene gamma sterilized in air. Presented at the 40th Annual Meeting of the Orthopaedic Research Society, New Orleans, LA, February 1994
-
(1994)
40th Annual Meeting of the Orthopaedic Research Society
-
-
Saum, K.A.1
|