메뉴 건너뛰기




Volumn 9, Issue 1, 1999, Pages 13-20

Effect of sliding locus on subsurface crack formation in ultra-high- molecular-weight polyethylene knee component

Author keywords

Artificial knee joint; Delamination; Fatigue; UHMWPE; Wear

Indexed keywords

POLYETHYLENE DERIVATIVE;

EID: 0032986185     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (14)
  • 1
    • 0023697318 scopus 로고
    • Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses
    • M.M. Landy and P.S. Walker, Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prostheses, J. Arthroplasty 3 (1988), 73-85.
    • (1988) J. Arthroplasty , vol.3 , pp. 73-85
    • Landy, M.M.1    Walker, P.S.2
  • 3
    • 0026202775 scopus 로고
    • Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation
    • M.S. Jahan, C. Wang, G. Schwartz and J.A. Davidson, Combined chemical and mechanical effects on free radicals in UHMWPE joints during implantation, J. Biomed. Mater. Res. 25 (1991), 1005-1017.
    • (1991) J. Biomed. Mater. Res. , vol.25 , pp. 1005-1017
    • Jahan, M.S.1    Wang, C.2    Schwartz, G.3    Davidson, J.A.4
  • 4
    • 0031924955 scopus 로고    scopus 로고
    • Effect of oxidation on delamination of ultra-high-molecular-weight polyethylene tibial components
    • C.J. Bell, P.S. Walker, M.R. Abeysundera et al, Effect of oxidation on delamination of ultra-high-molecular-weight polyethylene tibial components, J. Arthroplasty 13 (1998), 280-290.
    • (1998) J. Arthroplasty , vol.13 , pp. 280-290
    • Bell, C.J.1    Walker, P.S.2    Abeysundera, M.R.3
  • 5
    • 2442740264 scopus 로고    scopus 로고
    • Durability of artificial knee joint
    • in Japanese
    • N. Tomita, Durability of artificial knee joint, Orthopaedic Surgery and Traumatology 40 (1997), 1293-1301 (in Japanese).
    • (1997) Orthopaedic Surgery and Traumatology , vol.40 , pp. 1293-1301
    • Tomita, N.1
  • 6
    • 0001738320 scopus 로고    scopus 로고
    • Gamma sterilization of UHMWPE articular implants: An analysis of the oxidation problem
    • V. Premnath, W.H. Harris, M. Jasty and E.W. Merrill, Gamma sterilization of UHMWPE articular implants: an analysis of the oxidation problem, Biomaterials 17 (1996), 1741-1753.
    • (1996) Biomaterials , vol.17 , pp. 1741-1753
    • Premnath, V.1    Harris, W.H.2    Jasty, M.3    Merrill, E.W.4
  • 7
    • 0031412462 scopus 로고    scopus 로고
    • Validation of a small punch testing technique to characterize the mechanical behaviour of ultra-high-molecular-weight polyethylene
    • S.M. Kurtz, J.R. Foulds, C.W. Jewett, S. Srivastav and A.A. Edidin, Validation of a small punch testing technique to characterize the mechanical behaviour of ultra-high-molecular-weight polyethylene, Biomaterials 18 (1997), 1659-1663.
    • (1997) Biomaterials , vol.18 , pp. 1659-1663
    • Kurtz, S.M.1    Foulds, J.R.2    Jewett, C.W.3    Srivastav, S.4    Edidin, A.A.5
  • 8
    • 0031699750 scopus 로고    scopus 로고
    • Ultrasonic evaluation of ultra-high molecular weight polyethylene used in medical prostheses
    • C.S. Ong and N. Saffari, Ultrasonic evaluation of ultra-high molecular weight polyethylene used in medical prostheses Proc. Inst. Mech. Eng. 212(Part H) (1998), 65-69.
    • (1998) Proc. Inst. Mech. Eng. , vol.212 , Issue.PART H , pp. 65-69
    • Ong, C.S.1    Saffari, N.2
  • 9
    • 0030342777 scopus 로고    scopus 로고
    • An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact
    • M. Ohashi, N. Tomita, Y. Ikada and K. Ikeuchi, An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact, Biomed. Mater. Eng. 6 (1996), 441-451.
    • (1996) Biomed. Mater. Eng. , vol.6 , pp. 441-451
    • Ohashi, M.1    Tomita, N.2    Ikada, Y.3    Ikeuchi, K.4
  • 10
    • 0012286313 scopus 로고    scopus 로고
    • The effect of compressive load on formation of fatigue crack in UHMWPE
    • in Japanese
    • N. Tomita, M. Ohashi, K. Ikeuchi et al., The effect of compressive load on formation of fatigue crack in UHMWPE, J. Jap. Soc. Clin. Biomech. Rela. Res. 18 (1997), 459-461 (in Japanese).
    • (1997) J. Jap. Soc. Clin. Biomech. Rela. Res. , vol.18 , pp. 459-461
    • Tomita, N.1    Ohashi, M.2    Ikeuchi, K.3
  • 11
    • 0346661490 scopus 로고    scopus 로고
    • Contribution of grain boundary for subsurface crack to form in UHMWPE component of knee prostheses: Morphology of cracks in UHMWPE under experimental and clinical condition
    • unpublished observation
    • M. Ohashi, N. Tomita, K. Nakakita and K. Ikeuchi, Contribution of grain boundary for subsurface crack to form in UHMWPE component of knee prostheses: morphology of cracks in UHMWPE under experimental and clinical condition, Wear (unpublished observation).
    • Wear
    • Ohashi, M.1    Tomita, N.2    Nakakita, K.3    Ikeuchi, K.4
  • 12
    • 0027453287 scopus 로고
    • Reoperation after condylar revision total knee arthroplasty
    • M.J. Stuart, J.E. Larson and B.F. Money, Reoperation after condylar revision total knee arthroplasty, Clin. Orthop. 286 (1993), 168-173.
    • (1993) Clin. Orthop. , vol.286 , pp. 168-173
    • Stuart, M.J.1    Larson, J.E.2    Money, B.F.3
  • 13
    • 0032126428 scopus 로고    scopus 로고
    • A multidirectional motion pin-on-disk wear test method for prosthetic joint materials
    • V. Saikko, A multidirectional motion pin-on-disk wear test method for prosthetic joint materials, J. Biomed. Mater. Res. 41 (1998), 58-64.
    • (1998) J. Biomed. Mater. Res. , vol.41 , pp. 58-64
    • Saikko, V.1
  • 14
    • 0029725748 scopus 로고    scopus 로고
    • Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses
    • A. Wang, C. Stark and J.H. Dumbleton, Mechanistic and morphological origins of ultra-high molecular weight polyethylene wear debris in total joint replacement prostheses, Proc. Inst. Mech. Eng. 210 (1996), 141-155.
    • (1996) Proc. Inst. Mech. Eng. , vol.210 , pp. 141-155
    • Wang, A.1    Stark, C.2    Dumbleton, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.