메뉴 건너뛰기




Volumn 6, Issue 6, 1996, Pages 441-451

An observation on subsurface defects of ultra high molecular weight polyethylene due to rolling contact

Author keywords

Artificial knee joint; Fatigue; SAT; UHMWPE; Wear

Indexed keywords

POLYETHYLENE DERIVATIVE;

EID: 0030342777     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: 10.3233/bme-1996-6605     Document Type: Article
Times cited : (8)

References (17)
  • 1
    • 0028129938 scopus 로고
    • Current concept review ultra-high molecular weight polyethylene: The material and its use in total joint implants
    • S. Li and A.H. Burnstein, Current concept review ultra-high molecular weight polyethylene: the material and its use in total joint implants, J. Bone Joint Surg. 74A (1994), 1080-1090.
    • (1994) J. Bone Joint Surg. , vol.74 A , pp. 1080-1090
    • Li, S.1    Burnstein, A.H.2
  • 5
    • 0023697318 scopus 로고
    • Wear of ultra high molecular weight polyethylene components of 90 retrieved knee prostheses
    • Oct.
    • M.M. Landy and P.S. Walker, Wear of ultra high molecular weight polyethylene components of 90 retrieved knee prostheses, The Journal of Arthroplasty, Oct. 1988, S73-S85.
    • (1988) The Journal of Arthroplasty
    • Landy, M.M.1    Walker, P.S.2
  • 7
    • 0029253653 scopus 로고
    • The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses
    • P.S.M. Barbour, D.C. Barton and J. Fisher, The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses, Wear, 1995, 181-183, 250-257.
    • (1995) Wear , pp. 181-183
    • Barbour, P.S.M.1    Barton, D.C.2    Fisher, J.3
  • 8
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total joint replacements (oscillatory cycle ware, calculation)
    • A. Wang, D.C. Sun, C. Stark and J.H. Dumbleton, Wear mechanisms of UHMWPE in total joint replacements (oscillatory cycle ware, calculation), Wear, 1995, 181-183, 241-249.
    • (1995) Wear , pp. 181-183
    • Wang, A.1    Sun, D.C.2    Stark, C.3    Dumbleton, J.H.4
  • 10
    • 0027703214 scopus 로고
    • Contact mechanisms of ultra high molecular weight polyethylene for artificial knee joint
    • H. Fujiki, H. Ishikawa and K. Yasuda, Contact mechanisms of ultra high molecular weight polyethylene for artificial knee joint, Trans. JSME 59A(567) (1993), 2800-2807.
    • (1993) Trans. JSME , vol.59 A , Issue.567 , pp. 2800-2807
    • Fujiki, H.1    Ishikawa, H.2    Yasuda, K.3
  • 11
    • 0028396457 scopus 로고
    • Effect of loading mode on rolling-sliding mechanism in UHMWPE
    • H. Fujiki, H. Ishikawa and K. Yasuda, Effect of loading mode on rolling-sliding mechanism in UHMWPE, Trans. JSME 60A(571) (1992), 833-840.
    • (1992) Trans. JSME , vol.60 A , Issue.571 , pp. 833-840
    • Fujiki, H.1    Ishikawa, H.2    Yasuda, K.3
  • 12
    • 0028493730 scopus 로고
    • The effect of thickness and fixation of ultra high molecular weight polyethylene and of traction on wear behavior in artificial knee joint
    • H. Fujiki, H. Ishikawa and K. Yasuda, The effect of thickness and fixation of ultra high molecular weight polyethylene and of traction on wear behavior in artificial knee joint, Trans. JSME 60A(576) (1994), 1871-1877.
    • (1994) Trans. JSME , vol.60 A , Issue.576 , pp. 1871-1877
    • Fujiki, H.1    Ishikawa, H.2    Yasuda, K.3
  • 13
    • 0029251857 scopus 로고
    • Contact analysis of artificial knee joint during gait movement
    • H. Fujiki, H. Ishikawa and K. Yasuda, Contact analysis of artificial knee joint during gait movement, Trans. JSME 61A(582) (1995), 472-479.
    • (1995) Trans. JSME , vol.61 A , Issue.582 , pp. 472-479
    • Fujiki, H.1    Ishikawa, H.2    Yasuda, K.3
  • 14
    • 0029308177 scopus 로고
    • Contact analysis of artificial knee joint during gait (2nd Report, Effect of Shape of Contact Surface on wear Behavior of UHMWPE of Articular Plate)
    • H. Fujiki, H. Ishikawa and K. Yasuda, Contact analysis of artificial knee joint during gait (2nd Report, Effect of Shape of Contact Surface on wear Behavior of UHMWPE of Articular Plate), JSME 61A(585) (1995), 1129-1135.
    • (1995) JSME , vol.61 A , Issue.585 , pp. 1129-1135
    • Fujiki, H.1    Ishikawa, H.2    Yasuda, K.3
  • 15
    • 0029197651 scopus 로고
    • Contact pressure prediction in total knee joint replacements. Part 1: General elasticity solution for elliptical layered contacts
    • Z.M. Jin, D. Dowson and J. Fisher, Contact pressure prediction in total knee joint replacements. Part 1: General elasticity solution for elliptical layered contacts, Proc. Instn. Mech. Engrs., Part H 209 (1995), 1-8.
    • (1995) Proc. Instn. Mech. Engrs., Part H , vol.209 , pp. 1-8
    • Jin, Z.M.1    Dowson, D.2    Fisher, J.3
  • 16
    • 0029197652 scopus 로고
    • Contact pressure prediction in total knee joint replacements. Part 2: Application to the design of total knee joint replacements
    • Z.M. Jin, T. Stewart, D.D. Auger, D. Dowson and J. Fisher, Contact pressure prediction in total knee joint replacements. Part 2: Application to the design of total knee joint replacements, Proc. Instn. Mech. Engrs., Part H 209 (1995), 9-15.
    • (1995) Proc. Instn. Mech. Engrs., Part H , vol.209 , pp. 9-15
    • Jin, Z.M.1    Stewart, T.2    Auger, D.D.3    Dowson, D.4    Fisher, J.5
  • 17
    • 0028486355 scopus 로고
    • Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip joint simulator
    • V. Saikko, Wear of polyethylene acetabular cups against zirconia femoral heads studied with a hip joint simulator, Wear 176 (1994), 207-212.
    • (1994) Wear , vol.176 , pp. 207-212
    • Saikko, V.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.