Volumn 10, Issue 4, 2003, Pages 807-824

Biocompatibility and Biostability of Metallic Endovascular Implants: State of the Art and Perspectives

Author keywords

Biocompatibility; Biostability; Corrosion; Elgiloy; Metals; Nitinol; Restenosis; Stainless steel; Stents

Indexed keywords

ALLOY; BIOMATERIAL; METAL; NITINOL; POLITEF; STAINLESS STEEL; TANTALUM;

EID: 0242331797     PISSN: 15266028     EISSN: None     Source Type: Journal    
DOI: 10.1583/1545-1550(2003)010<0807:BABOME>2.0.CO;2     Document Type: Review
Times cited : (32)

References (116)
  • 1
    • 0036013823 scopus 로고    scopus 로고
    • Nitinol versus stainless steel stents: Acute thrombogenicity study in an ex vivo porcine model
    • Thierry B, Merhi Y, Bilodeau L, et al. Nitinol versus stainless steel stents: acute thrombogenicity study in an ex vivo porcine model. Biomaterials. 2002;23:2997-3005.
    • (2002) Biomaterials , vol.23 , pp. 2997-3005
    • Thierry, B.1    Merhi, Y.2    Bilodeau, L.3
  • 3
    • 0242388193 scopus 로고    scopus 로고
    • Retrieval analysis of stainless steel plate/screws implanted for 55 years
    • Mt. Laurel, NJ: Society for Biomaterials
    • Disegi J, Zardiackas L. Retrieval analysis of stainless steel plate/screws implanted for 55 years [Abstract]. In: Proceeding of the 27th Meeting of the Society for Biomaterials. Mt. Laurel, NJ: Society for Biomaterials; 2000.
    • (2000) Proceeding of the 27th Meeting of the Society for Biomaterials
    • Disegi, J.1    Zardiackas, L.2
  • 4
    • 0033865287 scopus 로고    scopus 로고
    • First-generation aortic endografts: Analysis of explanted Stentor devices from the EUROSTAR registry
    • Guidoin R, Marois Y, Douville Y, et al. First-generation aortic endografts: analysis of explanted Stentor devices from the EUROSTAR registry. J Endovasc Ther. 2000;7:105-122.
    • (2000) J Endovasc Ther , vol.7 , pp. 105-122
    • Guidoin, R.1    Marois, Y.2    Douville, Y.3
  • 5
    • 0034911604 scopus 로고    scopus 로고
    • Corroded nitinol wires in explanted aortic endografts: An important mechanism of failure?
    • Heintz C, Riepe G, Birken L, et al. Corroded nitinol wires in explanted aortic endografts: an important mechanism of failure? J Endovasc Ther. 2001;8:248-253.
    • (2001) J Endovasc Ther , vol.8 , pp. 248-253
    • Heintz, C.1    Riepe, G.2    Birken, L.3
  • 6
    • 0034597889 scopus 로고    scopus 로고
    • Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
    • Koster R, Vieluf D, Kiehn M, et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet. 2000;356:1895-1897.
    • (2000) Lancet , vol.356 , pp. 1895-1897
    • Koster, R.1    Vieluf, D.2    Kiehn, M.3
  • 7
    • 0342858846 scopus 로고    scopus 로고
    • Increased risk of restenosis after placement of gold-coated stents: Results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease
    • Kastrati A, Schomig A, Dirschinger J, et al. Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease. Circulation. 2000;101:2478-2483.
    • (2000) Circulation , vol.101 , pp. 2478-2483
    • Kastrati, A.1    Schomig, A.2    Dirschinger, J.3
  • 8
    • 0035936526 scopus 로고    scopus 로고
    • Gold-coated NIR stents in porcine coronary arteries
    • Edelman ER, Seifert P, Groothuis A, et al. Gold-coated NIR stents in porcine coronary arteries. Circulation. 2001;103:429-434.
    • (2001) Circulation , vol.103 , pp. 429-434
    • Edelman, E.R.1    Seifert, P.2    Groothuis, A.3
  • 9
    • 1642618096 scopus 로고    scopus 로고
    • Assessing the corrosion behaviour of nitinol for minimally-invasive device design
    • Venugopalan R, Trépanier C. Assessing the corrosion behaviour of nitinol for minimally-invasive device design. Minim Invasive Ther Allied Technol. 2000;9:67-74.
    • (2000) Minim Invasive Ther Allied Technol , vol.9 , pp. 67-74
    • Venugopalan, R.1    Trépanier, C.2
  • 10
    • 0034757333 scopus 로고    scopus 로고
    • Role of stenting in coronary revascularisation
    • Gershlick AH. Role of stenting in coronary revascularisation. Heart. 2001;86:104-112.
    • (2001) Heart , vol.86 , pp. 104-112
    • Gershlick, A.H.1
  • 14
    • 0033768819 scopus 로고    scopus 로고
    • A novel platinum-iridium, potentially gamma radioactive stent: Evaluation in a porcine model
    • Bhargava B, De Scheerder I, Ping QB, et al. A novel platinum-iridium, potentially gamma radioactive stent: evaluation in a porcine model. Catheter Cardiovasc Interv. 2000;51:364-368.
    • (2000) Catheter Cardiovasc Interv , vol.51 , pp. 364-368
    • Bhargava, B.1    De Scheerder, I.2    Ping, Q.B.3
  • 15
    • 0035083976 scopus 로고    scopus 로고
    • A precious metal alloy for construction of MR imaging-compatible balloon-expandable vascular stents
    • van Dijk LC, van Holten J, van Dijk BP, et al. A precious metal alloy for construction of MR imaging-compatible balloon-expandable vascular stents. Radiology. 2001;219:284-287.
    • (2001) Radiology , vol.219 , pp. 284-287
    • Van Dijk, L.C.1    Van Holten, J.2    Van Dijk, B.P.3
  • 16
    • 0034129571 scopus 로고    scopus 로고
    • Magnetic resonance monitoring of stent deployment: In vitro evaluation of different stent designs and stent delivery systems
    • Manke C, Nitz WR, Lenhart M, et al. Magnetic resonance monitoring of stent deployment: in vitro evaluation of different stent designs and stent delivery systems. Invest Radiol. 2000;35:343-351.
    • (2000) Invest Radiol , vol.35 , pp. 343-351
    • Manke, C.1    Nitz, W.R.2    Lenhart, M.3
  • 17
    • 0035660731 scopus 로고    scopus 로고
    • Multislice CT angiography of the iliac arteries in the presence of various stents: In vitro evaluation of artifacts and lumen visibility
    • Maintz D, Fischbach R, Juergens KU, et al. Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility. Invest Radiol. 2001;36:699-704.
    • (2001) Invest Radiol , vol.36 , pp. 699-704
    • Maintz, D.1    Fischbach, R.2    Juergens, K.U.3
  • 18
    • 0038486163 scopus 로고    scopus 로고
    • Biocorrosion of magnesium alloys: A new principle in cardiovascular implant technology?
    • Heublein B, Rohde R, Kaese V, et al. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology? Heart. 2003;89:651-656.
    • (2003) Heart , vol.89 , pp. 651-656
    • Heublein, B.1    Rohde, R.2    Kaese, V.3
  • 19
    • 0034778878 scopus 로고    scopus 로고
    • A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits
    • Peuster M, Wohlsein P, Brugmann M, et al. A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits. Heart. 2001;86:563-569.
    • (2001) Heart , vol.86 , pp. 563-569
    • Peuster, M.1    Wohlsein, P.2    Brugmann, M.3
  • 20
    • 0242293664 scopus 로고
    • Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants
    • Philadelphia: American Society for Testing and Materials
    • ASTM F86. Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants. In: Annual Book of ASTM Standards: Medical Devices and Services, Vol. 13.01. Philadelphia: American Society for Testing and Materials; 1995:6-8.
    • (1995) Annual Book of ASTM Standards: Medical Devices and Services , vol.1301 , pp. 6-8
  • 21
    • 0032403412 scopus 로고    scopus 로고
    • Effect of modification of oxide layer on NiTi stent corrosion resistance
    • Trépanier C, Tabrizian M, Yahia LH, et al. Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res. 1998;43:433-440.
    • (1998) J Biomed Mater Res , vol.43 , pp. 433-440
    • Trépanier, C.1    Tabrizian, M.2    Yahia, L.H.3
  • 23
    • 0020111776 scopus 로고
    • The effects of proteins on metallic corrosion
    • Clark GC, Williams DF. The effects of proteins on metallic corrosion. J Biomed Mater Res. 1982;16:125-134.
    • (1982) J Biomed Mater Res , vol.16 , pp. 125-134
    • Clark, G.C.1    Williams, D.F.2
  • 24
    • 0033120166 scopus 로고    scopus 로고
    • The corrosion behaviour of Ti-6AI-4V, Ti-6AI-7Nb and Ti-13Nb-13Zr in protein solutions
    • Khan MA, Williams RL, Williams DF. The corrosion behaviour of Ti-6AI-4V, Ti-6AI-7Nb and Ti-13Nb-13Zr in protein solutions. Biomaterials. 1999;20:631-637.
    • (1999) Biomaterials , vol.20 , pp. 631-637
    • Khan, M.A.1    Williams, R.L.2    Williams, D.F.3
  • 25
    • 0035458268 scopus 로고    scopus 로고
    • Elemental release from dental casting alloys into biological media with and without protein
    • Wataha JC, Nelson SK, Lockwood PE. Elemental release from dental casting alloys into biological media with and without protein. Dent Mater. 2001;17:409-414.
    • (2001) Dent Mater , vol.17 , pp. 409-414
    • Wataha, J.C.1    Nelson, S.K.2    Lockwood, P.E.3
  • 26
    • 0034333617 scopus 로고    scopus 로고
    • The behavior of stainless steels in physiological solution containing complexing agent studied by X-ray photoelectron spectroscopy
    • Milosev I, Strehblow HH. The behavior of stainless steels in physiological solution containing complexing agent studied by X-ray photoelectron spectroscopy. J Biomed Mater Res. 2000;52:404-412.
    • (2000) J Biomed Mater Res , vol.52 , pp. 404-412
    • Milosev, I.1    Strehblow, H.H.2
  • 27
    • 0034142581 scopus 로고    scopus 로고
    • Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro
    • Mu Y, Kobayashi T, Sumita M, et al. Metal ion release from titanium with active oxygen species generated by rat macrophages in vitro. J Biomed Mater Res. 2000;49:238-243.
    • (2000) J Biomed Mater Res , vol.49 , pp. 238-243
    • Mu, Y.1    Kobayashi, T.2    Sumita, M.3
  • 28
    • 0242293644 scopus 로고    scopus 로고
    • Evaluation of the effect of cells on the corrosion behavior of implant alloys
    • Mt. Laurel, NJ: Society for Biomaterials
    • Hutchinson BS, Baumgardner JD. Evaluation of the effect of cells on the corrosion behavior of implant alloys [Abstract]. In: Proceedings of the World Biomaterials Congress. Mt. Laurel, NJ: Society for Biomaterials; 2000.
    • (2000) Proceedings of the World Biomaterials Congress
    • Hutchinson, B.S.1    Baumgardner, J.D.2
  • 29
    • 0021337206 scopus 로고
    • Isolation of serum protein organometallic corrosion products from 316LSS and HS-21 in vitro and in vivo
    • Woodman JL, Black J, Jiminez SA. Isolation of serum protein organometallic corrosion products from 316LSS and HS-21 in vitro and in vivo. J Biomed Mater Res. 1984;18:99-114.
    • (1984) J Biomed Mater Res , vol.18 , pp. 99-114
    • Woodman, J.L.1    Black, J.2    Jiminez, S.A.3
  • 30
    • 0031727764 scopus 로고    scopus 로고
    • Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study
    • Jacobs JJ, Skipor AK, Patterson LM, et al. Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study. J Bone Joint Surg Am. 1998;80:1447-1458.
    • (1998) J Bone Joint Surg Am , vol.80 , pp. 1447-1458
    • Jacobs, J.J.1    Skipor, A.K.2    Patterson, L.M.3
  • 31
  • 32
    • 0242388157 scopus 로고    scopus 로고
    • Corrosion fatigue
    • Revie RW, ed. Chichester, UK: Wiley
    • Wang YZ. Corrosion fatigue. In: Revie RW, ed. Uhlig's Corrosion Handbook. 2nd ed. Chichester, UK: Wiley; 2000:221-232.
    • (2000) Uhlig's Corrosion Handbook. 2nd Ed. , pp. 221-232
    • Wang, Y.Z.1
  • 33
    • 0029076961 scopus 로고
    • Physico-chemical observations on a failed Greenfield vena cava filter
    • Emanuelli G, Gatti AM, Cigada A, et al. Physico-chemical observations on a failed Greenfield vena cava filter. J Cardiovasc Surg (Torino). 1995;36:121-125.
    • (1995) J Cardiovasc Surg (Torino) , vol.36 , pp. 121-125
    • Emanuelli, G.1    Gatti, A.M.2    Cigada, A.3
  • 34
    • 0033527928 scopus 로고    scopus 로고
    • Fatigue-crack propagation in Nitinol, a shape-memory and superelastic endovascular stent material
    • McKelvey AL, Ritchie RO. Fatigue-crack propagation in Nitinol, a shape-memory and superelastic endovascular stent material. J Biomed Mater Res. 1999;47:301-308.
    • (1999) J Biomed Mater Res , vol.47 , pp. 301-308
    • McKelvey, A.L.1    Ritchie, R.O.2
  • 35
    • 0035989725 scopus 로고    scopus 로고
    • Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material
    • Reclaru L, Lerf R, Eschler PY, et al. Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material. Biomaterials. 2002;23:3479-3485.
    • (2002) Biomaterials , vol.23 , pp. 3479-3485
    • Reclaru, L.1    Lerf, R.2    Eschler, P.Y.3
  • 36
    • 0013504721 scopus 로고
    • Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements
    • Philadelphia: American Society for Testing and Materials
    • ASTM G5. Standard Reference Test Method for Making Potentiostatic and Potentiodynamic Anodic Polarization Measurements. In: Annual Book of ASTM Standards: Metals, Test Methods and Analytical Procedures. Philadelphia: American Society for Testing and Materials; 1995:48-58.
    • (1995) Annual Book of ASTM Standards: Metals, Test Methods and Analytical Procedures , pp. 48-58
  • 37
    • 0242293642 scopus 로고
    • Standard Practice for Calculation of Corrosion Rates and Related Information From Electrochemical Measurements
    • Philadelphia: American Society for Testing and Materials
    • ASTM G102. Standard Practice for Calculation of Corrosion Rates and Related Information From Electrochemical Measurements. In: Annual Book of ASTM Standards: Metals, Test Methods and Analytical Procedures. Philadelphia: American Society for Testing and Materials; 1995:401-407.
    • (1995) Annual Book of ASTM Standards: Metals, Test Methods and Analytical Procedures , pp. 401-407
  • 38
    • 0242356588 scopus 로고
    • Standard Test Method for Pitting or Crevice Corrosion of Metallic Surgical Implant Materials
    • Philadelphia: American Society for Testing and Materials
    • ASTM F746. Standard Test Method for Pitting or Crevice Corrosion of Metallic Surgical Implant Materials. In: Annual Book of ASTM Standards: Metals, Test Methods and Analytical Procedures. Philadelphia: American Society for Testing and Materials; 1995:192-197.
    • (1995) Annual Book of ASTM Standards: Metals, Test Methods and Analytical Procedures , pp. 192-197
  • 39
    • 0842292821 scopus 로고    scopus 로고
    • Effect of passivation treatments on nickel release from nitinol
    • Mt. Laurel, NJ: Society for Biomaterials
    • Trépanier C, Venugopalan R, Messer R, et al. Effect of passivation treatments on nickel release from nitinol [Abstract]. In: Proceeding of the World Biomaterials Congress. Mt. Laurel, NJ: Society for Biomaterials; 2000.
    • (2000) Proceeding of the World Biomaterials Congress
    • Trépanier, C.1    Venugopalan, R.2    Messer, R.3
  • 40
    • 0035424425 scopus 로고    scopus 로고
    • Structure and surface of TiNi human implants
    • Fili P, Lausmaa J, Musialek J, et al. Structure and surface of TiNi human implants. Biomaterials. 2001;22:2131-2138.
    • (2001) Biomaterials , vol.22 , pp. 2131-2138
    • Fili, P.1    Lausmaa, J.2    Musialek, J.3
  • 41
    • 0034666762 scopus 로고    scopus 로고
    • Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy
    • Thierry B, Tabrizian M, Trépanier C, et al. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mater Res. 2000;51:685-693.
    • (2000) J Biomed Mater Res , vol.51 , pp. 685-693
    • Thierry, B.1    Tabrizian, M.2    Trépanier, C.3
  • 42
    • 2642582913 scopus 로고    scopus 로고
    • Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures
    • Ryhanen J, Niemi E, Serlo W, et al. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures. J Biomed Mater Res. 1997;35:451-457.
    • (1997) J Biomed Mater Res , vol.35 , pp. 451-457
    • Ryhanen, J.1    Niemi, E.2    Serlo, W.3
  • 43
    • 0032052625 scopus 로고    scopus 로고
    • Electrochemical and surface characterization of a nickel-titanium alloy
    • Wever DJ, Veldhuizen AG, de Vries J, et al. Electrochemical and surface characterization of a nickel-titanium alloy. Biomaterials. 1998;19:761-769.
    • (1998) Biomaterials , vol.19 , pp. 761-769
    • Wever, D.J.1    Veldhuizen, A.G.2    De Vries, J.3
  • 44
    • 0030272059 scopus 로고    scopus 로고
    • Corrosion resistance tests on NiTi shape memory alloy
    • Rondelli G. Corrosion resistance tests on NiTi shape memory alloy. Biomaterials. 1996;17:2003-2008.
    • (1996) Biomaterials , vol.17 , pp. 2003-2008
    • Rondelli, G.1
  • 45
    • 0032746783 scopus 로고    scopus 로고
    • Corrosion testing of stents: A novel fixture to hold entire device in deployed form and finish
    • Venugopalan R. Corrosion testing of stents: a novel fixture to hold entire device in deployed form and finish. J Biomed Mater Res. 1999;48:829-832.
    • (1999) J Biomed Mater Res , vol.48 , pp. 829-832
    • Venugopalan, R.1
  • 46
    • 0031239564 scopus 로고    scopus 로고
    • Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants
    • Clerc CO, Jedwab MR, Mayer DW, et al. Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants. J Biomed Mater Res. 1997;38:229-234.
    • (1997) J Biomed Mater Res , vol.38 , pp. 229-234
    • Clerc, C.O.1    Jedwab, M.R.2    Mayer, D.W.3
  • 47
    • 0031465283 scopus 로고    scopus 로고
    • Characteristics of metals used in implants
    • Gotman I. Characteristics of metals used in implants. J Endourol. 1997;11:383-389.
    • (1997) J Endourol , vol.11 , pp. 383-389
    • Gotman, I.1
  • 48
    • 0034701018 scopus 로고    scopus 로고
    • Stent and artery geometry determine intimal thickening independent of arterial injury
    • Garasic JM, Edelman ER, Squire JC, et al. Stent and artery geometry determine intimal thickening independent of arterial injury. Circulation. 2000;101:812-818.
    • (2000) Circulation , vol.101 , pp. 812-818
    • Garasic, J.M.1    Edelman, E.R.2    Squire, J.C.3
  • 49
    • 0035849543 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results: Strut thickness effect on restenosis outcome (ISAR-STEREO) trial
    • Kastrati A, Mehilli J, Dirschinger J, et al. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation. 2001;103:2816-2821.
    • (2001) Circulation , vol.103 , pp. 2816-2821
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 50
    • 0035188478 scopus 로고    scopus 로고
    • Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study
    • Hoffmann R, Jansen C, Konig A, et al. Stent design related neointimal tissue proliferation in human coronary arteries; an intravascular ultrasound study. Eur Heart J. 2001;22:2007-2014.
    • (2001) Eur Heart J , vol.22 , pp. 2007-2014
    • Hoffmann, R.1    Jansen, C.2    Konig, A.3
  • 51
    • 0034869192 scopus 로고    scopus 로고
    • Does stent design affect probability of restenosis? A randomized trial comparing Multilink stents with GFX stents
    • Yoshitomi Y, Kojima S, Yano M, et al. Does stent design affect probability of restenosis? A randomized trial comparing Multilink stents with GFX stents. Am Heart J. 2001;142:445-451.
    • (2001) Am Heart J , vol.142 , pp. 445-451
    • Yoshitomi, Y.1    Kojima, S.2    Yano, M.3
  • 52
    • 0035178080 scopus 로고    scopus 로고
    • Restenosis after coronary placement of various stent types
    • Kastrati A, Mehilli J, Dirschinger J, et al. Restenosis after coronary placement of various stent types. Am J Cardiol. 2001;87:34-39.
    • (2001) Am J Cardiol , vol.87 , pp. 34-39
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 53
    • 0033168576 scopus 로고    scopus 로고
    • Does stent design influence restenosis?
    • Gunn J, Cumberland D. Does stent design influence restenosis? Eur Heart J. 1999;20:1009-1013.
    • (1999) Eur Heart J , vol.20 , pp. 1009-1013
    • Gunn, J.1    Cumberland, D.2
  • 54
    • 0034126191 scopus 로고    scopus 로고
    • Mechanical properties of metallic stents: How do these properties influence the choice of stent for specific lesions?
    • Dyet JF, Watts WG, Ettles DF, et al. Mechanical properties of metallic stents: how do these properties influence the choice of stent for specific lesions? Cardiovasc Intervent Radiol. 2000;23:47-54.
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 47-54
    • Dyet, J.F.1    Watts, W.G.2    Ettles, D.F.3
  • 55
    • 0029739551 scopus 로고    scopus 로고
    • Subacute thrombosis and vascular injury resulting from slotted-tube nitinol and stainless steel stents in a rabbit carotid artery model
    • Sheth S, Litvack F, Dev V, et al. Subacute thrombosis and vascular injury resulting from slotted-tube nitinol and stainless steel stents in a rabbit carotid artery model. Circulation. 1996;94:1733-1740.
    • (1996) Circulation , vol.94 , pp. 1733-1740
    • Sheth, S.1    Litvack, F.2    Dev, V.3
  • 56
    • 0031830801 scopus 로고    scopus 로고
    • Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding nitinol stent in an experimental model
    • Carter AJ, Scott D, Laird JR, et al. Progressive vascular remodeling and reduced neointimal formation after placement of a thermoelastic self-expanding nitinol stent in an experimental model. Cathet Cardiovasc Diagn. 1998;44:193-201.
    • (1998) Cathet Cardiovasc Diagn , vol.44 , pp. 193-201
    • Carter, A.J.1    Scott, D.2    Laird, J.R.3
  • 57
    • 0032972020 scopus 로고    scopus 로고
    • Differences in endothelial injury after balloon angioplasty, insertion of balloon-expanded stents or release of self-expanding stents: An electron microscopic experimental study
    • Harnek J, Zoucas E, Carlemalm E, et al. Differences in endothelial injury after balloon angioplasty, insertion of balloon-expanded stents or release of self-expanding stents: an electron microscopic experimental study. Cardiovasc Intervent Radiol. 1999;22:56-61.
    • (1999) Cardiovasc Intervent Radiol , vol.22 , pp. 56-61
    • Harnek, J.1    Zoucas, E.2    Carlemalm, E.3
  • 58
    • 0036242627 scopus 로고    scopus 로고
    • Comparison of the self-expanding Radius stent and the balloon-expandable Multilink stent for elective treatment of coronary stenoses: A serial analysis by intravascular ultrasound
    • Yu ZX, Tamai H, Kyo E, et al. Comparison of the self-expanding Radius stent and the balloon-expandable Multilink stent for elective treatment of coronary stenoses: a serial analysis by intravascular ultrasound. Catheter Cardiovasc Interv. 2002;56:40-45.
    • (2002) Catheter Cardiovasc Interv , vol.56 , pp. 40-45
    • Yu, Z.X.1    Tamai, H.2    Kyo, E.3
  • 59
    • 0032777189 scopus 로고    scopus 로고
    • Continued expansion of the nitinol self-expanding coronary stent: Angiographic analysis and 1-year clinical follow-up
    • Roguin A, Grenadier E, Linn S, et al. Continued expansion of the nitinol self-expanding coronary stent: angiographic analysis and 1-year clinical follow-up. Am Heart J. 1999;138:326-333.
    • (1999) Am Heart J , vol.138 , pp. 326-333
    • Roguin, A.1    Grenadier, E.2    Linn, S.3
  • 60
    • 0034932969 scopus 로고    scopus 로고
    • A comparison of four stent designs on arterial injury, cellular proliferation, neointima formation, and arterial dimensions in an experimental porcine model
    • Taylor AJ, Gorman PD, Kenwood B, et al. A comparison of four stent designs on arterial injury, cellular proliferation, neointima formation, and arterial dimensions in an experimental porcine model. Catheter Cardiovasc Interv. 2001;53:420-425.
    • (2001) Catheter Cardiovasc Interv , vol.53 , pp. 420-425
    • Taylor, A.J.1    Gorman, P.D.2    Kenwood, B.3
  • 61
    • 0035515728 scopus 로고    scopus 로고
    • Self-expanding stents for carotid interventions: Comparison of nitinol versus stainless-steel stents
    • Mukherjee D, Kalahasti V, Roffi M, et al. Self-expanding stents for carotid interventions: comparison of nitinol versus stainless-steel stents. J Invasive Cardiol. 2001;13:732-735.
    • (2001) J Invasive Cardiol , vol.13 , pp. 732-735
    • Mukherjee, D.1    Kalahasti, V.2    Roffi, M.3
  • 62
    • 0034463765 scopus 로고    scopus 로고
    • Exploiting the current paradigm of blood-material interactions for the rational design of blood-compatible materials
    • Brash JL. Exploiting the current paradigm of blood-material interactions for the rational design of blood-compatible materials. J Biomater Sci Polym Ed. 2000;11:1135-1146.
    • (2000) J Biomater Sci Polym Ed , vol.11 , pp. 1135-1146
    • Brash, J.L.1
  • 63
    • 0034464695 scopus 로고    scopus 로고
    • Blood compatibility - A perspective
    • Ratner BD. Blood compatibility - a perspective. J Biomater Sci Polym Ed. 2000;11:1107-1119.
    • (2000) J Biomater Sci Polym Ed , vol.11 , pp. 1107-1119
    • Ratner, B.D.1
  • 64
    • 0034954102 scopus 로고    scopus 로고
    • Two distinct mechanisms are involved in stent thrombosis under flow conditions
    • Eto K, Goto S, Shimazaki T, et al. Two distinct mechanisms are involved in stent thrombosis under flow conditions. Platelets. 2001;12:228-235.
    • (2001) Platelets , vol.12 , pp. 228-235
    • Eto, K.1    Goto, S.2    Shimazaki, T.3
  • 65
    • 0034327461 scopus 로고    scopus 로고
    • Activation and control of complement, inflammation, and infection associated with the use of biomedical polymers
    • Janatova J. Activation and control of complement, inflammation, and infection associated with the use of biomedical polymers. ASAIO J. 2000;46:S53-62.
    • (2000) ASAIO J , vol.46
    • Janatova, J.1
  • 66
    • 0030662390 scopus 로고    scopus 로고
    • Coagulation on biomaterials in flowing blood: Some theoretical considerations
    • Basmadjian D, Sefton MV, Baldwin SA. Coagulation on biomaterials in flowing blood: some theoretical considerations. Biomaterials. 1997;18:1511-1522.
    • (1997) Biomaterials , vol.18 , pp. 1511-1522
    • Basmadjian, D.1    Sefton, M.V.2    Baldwin, S.A.3
  • 67
    • 0032734191 scopus 로고    scopus 로고
    • Water and the acute biological response to surfaces
    • Vogler EA. Water and the acute biological response to surfaces. J Biomater Sci Polym Ed. 1999;10:1015-1045.
    • (1999) J Biomater Sci Polym Ed , vol.10 , pp. 1015-1045
    • Vogler, E.A.1
  • 69
    • 0034903696 scopus 로고    scopus 로고
    • Platelet interactions with titanium: Modulation of platelet activity by surface topography
    • Park JY, Gemmell CH, Davies JE. Platelet interactions with titanium: modulation of platelet activity by surface topography. Biomaterials. 2001;22:2671-2682.
    • (2001) Biomaterials , vol.22 , pp. 2671-2682
    • Park, J.Y.1    Gemmell, C.H.2    Davies, J.E.3
  • 70
    • 0034114979 scopus 로고    scopus 로고
    • Electrostatic forces on the surface of metals as measured by atomic force microscopy
    • Sprague EA, Palmaz JC, Simon C, et al. Electrostatic forces on the surface of metals as measured by atomic force microscopy. J Long Term Eff Med Implants. 2000;10:111-125.
    • (2000) J Long Term Eff Med Implants , vol.10 , pp. 111-125
    • Sprague, E.A.1    Palmaz, J.C.2    Simon, C.3
  • 71
    • 0242388158 scopus 로고
    • Biomaterials and biocompatibility: An introduction
    • Williams DF, ed. Boca Raton: CRC Press
    • Williams DF. Biomaterials and biocompatibility: an introduction. In: Williams DF, ed. Fundamental Aspects of Biocompatibility. Boca Raton: CRC Press; 1981:2-3.
    • (1981) Fundamental Aspects of Biocompatibility , pp. 2-3
    • Williams, D.F.1
  • 72
    • 0032487124 scopus 로고    scopus 로고
    • In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: Muscle and perineural tissue responses and encapsule membrane thickness
    • Ryhanen J, Kallioinen M, Tuukkanen J, et al. In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness. J Biomed Mater Res. 1998;41:481-488.
    • (1998) J Biomed Mater Res , vol.41 , pp. 481-488
    • Ryhanen, J.1    Kallioinen, M.2    Tuukkanen, J.3
  • 73
    • 0035372012 scopus 로고    scopus 로고
    • Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium
    • Matsuno H, Yokoyama A, Watari F, et al. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials. 2001;22:1253-1262.
    • (2001) Biomaterials , vol.22 , pp. 1253-1262
    • Matsuno, H.1    Yokoyama, A.2    Watari, F.3
  • 74
    • 0345129973 scopus 로고    scopus 로고
    • Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents
    • Trépanier C, Leung TK, Tabrizian M, et al. Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents. J Biomed Mater Res. 1999;48:165-171.
    • (1999) J Biomed Mater Res , vol.48 , pp. 165-171
    • Trépanier, C.1    Leung, T.K.2    Tabrizian, M.3
  • 75
    • 0033883498 scopus 로고    scopus 로고
    • Endovascular repair of thoracic aortic aneurysm in dogs: Evaluation of a nitinol-polyester self-expanding stent-graft
    • Formichi M, Marois Y, Roby P, et al. Endovascular repair of thoracic aortic aneurysm in dogs: evaluation of a nitinol-polyester self-expanding stent-graft. J Endovasc Ther. 2000;7:47-67.
    • (2000) J Endovasc Ther , vol.7 , pp. 47-67
    • Formichi, M.1    Marois, Y.2    Roby, P.3
  • 76
    • 0031939837 scopus 로고    scopus 로고
    • Wound healing: A paradigm for lumen narrowing after arterial reconstruction
    • Geary RL, Nikkari ST, Wagner WD, et al. Wound healing: a paradigm for lumen narrowing after arterial reconstruction. J Vasc Surg. 1998;27:96-108.
    • (1998) J Vasc Surg , vol.27 , pp. 96-108
    • Geary, R.L.1    Nikkari, S.T.2    Wagner, W.D.3
  • 78
    • 0034774586 scopus 로고    scopus 로고
    • Growth inhibition of cultured smooth muscle cells by corrosion products of 316 L stainless steel wire
    • Shih CC, Shih CM, Chen YL, et al. Growth inhibition of cultured smooth muscle cells by corrosion products of 316 L stainless steel wire. J Biomed Mater Res. 2001;57:200-207.
    • (2001) J Biomed Mater Res , vol.57 , pp. 200-207
    • Shih, C.C.1    Shih, C.M.2    Chen, Y.L.3
  • 79
    • 0034333616 scopus 로고    scopus 로고
    • The cytotoxicity of corrosion products of nitinol stent wire on cultured smooth muscle cells
    • Shih CC, Lin SJ, Chen YL, et al. The cytotoxicity of corrosion products of nitinol stent wire on cultured smooth muscle cells. J Biomed Mater Res. 2000;52:395-403.
    • (2000) J Biomed Mater Res , vol.52 , pp. 395-403
    • Shih, C.C.1    Lin, S.J.2    Chen, Y.L.3
  • 80
    • 0034801325 scopus 로고    scopus 로고
    • Relating nickel-induced tissue inflammation to nickel release in vivo
    • Wataha JC, O'Dell NL, Singh BB, et al. Relating nickel-induced tissue inflammation to nickel release in vivo. J Biomed Mater Res. 2001;58:537-544.
    • (2001) J Biomed Mater Res , vol.58 , pp. 537-544
    • Wataha, J.C.1    O'Dell, N.L.2    Singh, B.B.3
  • 81
    • 0033119620 scopus 로고    scopus 로고
    • Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy
    • Uo M, Watari F, Yokoyama A, et al. Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy. Biomaterials. 1999;20:747-755.
    • (1999) Biomaterials , vol.20 , pp. 747-755
    • Uo, M.1    Watari, F.2    Yokoyama, A.3
  • 82
    • 0032170249 scopus 로고    scopus 로고
    • Influence of metals on IL-6 release in vitro
    • Schmalz G, Schuster U, Schweikl H. Influence of metals on IL-6 release in vitro. Biomaterials. 1998;19:1689-1694.
    • (1998) Biomaterials , vol.19 , pp. 1689-1694
    • Schmalz, G.1    Schuster, U.2    Schweikl, H.3
  • 83
    • 0032943419 scopus 로고    scopus 로고
    • Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro
    • Wataha JC, Lockwood PE, Marek M, et al. Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro. J Biomed Mater Res. 1999;45:251-257.
    • (1999) J Biomed Mater Res , vol.45 , pp. 251-257
    • Wataha, J.C.1    Lockwood, P.E.2    Marek, M.3
  • 84
    • 0030275655 scopus 로고    scopus 로고
    • In vitro IL-1 beta and TNF-alpha release from THP-1 monocytes in response to metal ions
    • Wataha JC, Ratanasathien S, Hanks CT, et al. In vitro IL-1 beta and TNF-alpha release from THP-1 monocytes in response to metal ions. Dent Mater. 1996;12:322-327.
    • (1996) Dent Mater , vol.12 , pp. 322-327
    • Wataha, J.C.1    Ratanasathien, S.2    Hanks, C.T.3
  • 85
    • 0033982991 scopus 로고    scopus 로고
    • Immunologic mechanisms in hypersensitivity reactions to metal ions: An overview
    • Budinger L, Hertl M. Immunologic mechanisms in hypersensitivity reactions to metal ions: an overview. Allergy. 2000;55:108-115.
    • (2000) Allergy , vol.55 , pp. 108-115
    • Budinger, L.1    Hertl, M.2
  • 86
    • 0035020898 scopus 로고    scopus 로고
    • Cobalt-specific T lymphocytes in synovial tissue after an allergic reaction to a cobalt alloy joint prosthesis
    • Thomssen H, Hoffmann B, Schank M, et al. Cobalt-specific T lymphocytes in synovial tissue after an allergic reaction to a cobalt alloy joint prosthesis. J Rheumatol. 2001;28:1121-1128.
    • (2001) J Rheumatol , vol.28 , pp. 1121-1128
    • Thomssen, H.1    Hoffmann, B.2    Schank, M.3
  • 87
    • 0035108321 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopaedic implants
    • Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001;83-A:428-436.
    • (2001) J Bone Joint Surg Am , vol.83 A , pp. 428-436
    • Hallab, N.1    Merritt, K.2    Jacobs, J.J.3
  • 88
    • 2642515499 scopus 로고    scopus 로고
    • Metal-induced generalized pruriginous dermatitis and endovascular surgery
    • Gimenez-Arnau A, Riambau V, Serra-Baldrich E, et al. Metal-induced generalized pruriginous dermatitis and endovascular surgery. Contact Dermatitis. 2000;43:35-40.
    • (2000) Contact Dermatitis , vol.43 , pp. 35-40
    • Gimenez-Arnau, A.1    Riambau, V.2    Serra-Baldrich, E.3
  • 89
    • 0035176865 scopus 로고    scopus 로고
    • Coronary restenosis elimination with a sirolimus eluting stent: First European human experience with 6-month angiographic and intravascular ultrasonic follow-up
    • Rensing BJ, Vos J, Smits PC, et al. Coronary restenosis elimination with a sirolimus eluting stent: first European human experience with 6-month angiographic and intravascular ultrasonic follow-up. Eur Heart J. 2001;22:2125-2130.
    • (2001) Eur Heart J , vol.22 , pp. 2125-2130
    • Rensing, B.J.1    Vos, J.2    Smits, P.C.3
  • 90
    • 14344268774 scopus 로고    scopus 로고
    • Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis
    • Heldman AW, Cheng L, Jenkins GM, et al. Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis. Circulation. 2001;103:2289-2295.
    • (2001) Circulation , vol.103 , pp. 2289-2295
    • Heldman, A.W.1    Cheng, L.2    Jenkins, G.M.3
  • 91
    • 0035923822 scopus 로고    scopus 로고
    • American Heart Association 2001 scientific sessions: Late-breaking science-drug-eluting stents
    • Fox R. American Heart Association 2001 scientific sessions: late-breaking science-drug-eluting stents. Circulation. 2001;104:E9052.
    • (2001) Circulation , vol.104
    • Fox, R.1
  • 92
    • 0035940374 scopus 로고    scopus 로고
    • Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up
    • Sousa JE, Costa MA, Abizaid AC, et al. Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up. Circulation. 2001;104:2007-2011.
    • (2001) Circulation , vol.104 , pp. 2007-2011
    • Sousa, J.E.1    Costa, M.A.2    Abizaid, A.C.3
  • 94
    • 0037116881 scopus 로고    scopus 로고
    • Use of localised intracoronary beta radiation in treatment of in-stent restenosis: The INHIBIT randomised controlled trial
    • Waksman R, Raizner AE, Yeung AC, et al. Use of localised intracoronary beta radiation in treatment of in-stent restenosis: the INHIBIT randomised controlled trial. Lancet. 2002;359:551-557.
    • (2002) Lancet , vol.359 , pp. 551-557
    • Waksman, R.1    Raizner, A.E.2    Yeung, A.C.3
  • 95
    • 0037116569 scopus 로고    scopus 로고
    • Coronary in-stent restenosis: Current status and future strategies
    • Lowe HC, Oesterle SN, Khachigian LM. Coronary in-stent restenosis: current status and future strategies. J Am Coll Cardiol. 2002;39:183-193.
    • (2002) J Am Coll Cardiol , vol.39 , pp. 183-193
    • Lowe, H.C.1    Oesterle, S.N.2    Khachigian, L.M.3
  • 96
    • 0034602842 scopus 로고    scopus 로고
    • I like the candy, I hate the wrapper: The (32)P radioactive stent
    • Serruys PW, Kay IP. I like the candy, I hate the wrapper: the (32)P radioactive stent. Circulation. 2000;101:3-7.
    • (2000) Circulation , vol.101 , pp. 3-7
    • Serruys, P.W.1    Kay, I.P.2
  • 97
    • 0034242685 scopus 로고    scopus 로고
    • European high-activity (32)P radioactive stent experience
    • Albiero R, Colombo A. European high-activity (32)P radioactive stent experience. J Invasive Cardiol. 2000;12:416-421.
    • (2000) J Invasive Cardiol , vol.12 , pp. 416-421
    • Albiero, R.1    Colombo, A.2
  • 98
    • 0034786649 scopus 로고    scopus 로고
    • Late acute thrombosis after coronary brachytherapy: When is the risk over?
    • Liistro F, Gimelli G, Di Mario C, et al. Late acute thrombosis after coronary brachytherapy: when is the risk over? Catheter Cardiovasc Interv. 2001;54:216-218.
    • (2001) Catheter Cardiovasc Interv , vol.54 , pp. 216-218
    • Liistro, F.1    Gimelli, G.2    Di Mario, C.3
  • 99
    • 0034868643 scopus 로고    scopus 로고
    • Late acute thrombosis after paclitaxel eluting stent implantation
    • Liistro F, Colombo A. Late acute thrombosis after paclitaxel eluting stent implantation. Heart. 2001;86:262-264.
    • (2001) Heart , vol.86 , pp. 262-264
    • Liistro, F.1    Colombo, A.2
  • 100
    • 0035814962 scopus 로고    scopus 로고
    • Long-term efficacy of intracoronary irradiation in inhibiting in-stent restenosis
    • Brenner DJ, Miller RC. Long-term efficacy of intracoronary irradiation in inhibiting in-stent restenosis. Circulation. 2001;103:1330-1332.
    • (2001) Circulation , vol.103 , pp. 1330-1332
    • Brenner, D.J.1    Miller, R.C.2
  • 101
    • 0037161356 scopus 로고    scopus 로고
    • First clinical experience with a paclitaxel derivate-eluting polymer stent system implantation for in-stent restenosis: Immediate and long-term clinical and angiographic outcome
    • Liistro F, Stankovic G, Di Mario C, et al. First clinical experience with a paclitaxel derivate-eluting polymer stent system implantation for in-stent restenosis: immediate and long-term clinical and angiographic outcome. Circulation. 2002;105:1883-1886.
    • (2002) Circulation , vol.105 , pp. 1883-1886
    • Liistro, F.1    Stankovic, G.2    Di Mario, C.3
  • 102
    • 0035864267 scopus 로고    scopus 로고
    • Crosslinkable coatings from phosphorylcholine-based polymers
    • Lewis AL, Cumming ZL, Goreish HH, et al. Crosslinkable coatings from phosphorylcholine-based polymers. Biomaterials. 2001;22:99-111.
    • (2001) Biomaterials , vol.22 , pp. 99-111
    • Lewis, A.L.1    Cumming, Z.L.2    Goreish, H.H.3
  • 103
    • 0036533087 scopus 로고    scopus 로고
    • Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation
    • Lewis AL, Tolhurst LA, Stratford PW. Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation. Biomaterials. 2002;23:1697-1706.
    • (2002) Biomaterials , vol.23 , pp. 1697-1706
    • Lewis, A.L.1    Tolhurst, L.A.2    Stratford, P.W.3
  • 104
    • 0036193254 scopus 로고    scopus 로고
    • Stenting very small coronary narrowings (<2 mm) using the biocompatible phosphorylcholine-coated coronary stent
    • Grenadier E, Roguin A, Hertz I, et al. Stenting very small coronary narrowings (<2 mm) using the biocompatible phosphorylcholine-coated coronary stent. Catheter Cardiovasc Interv. 2002;55:303-308.
    • (2002) Catheter Cardiovasc Interv , vol.55 , pp. 303-308
    • Grenadier, E.1    Roguin, A.2    Hertz, I.3
  • 105
  • 106
    • 0034663643 scopus 로고    scopus 로고
    • Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial)
    • MENTOR Trial Investigators
    • Vrolix MC, Legrand VM, Reiber JH, et al. Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial). MENTOR Trial Investigators. Am J Cardiol. 2000;86:385-389.
    • (2000) Am J Cardiol , vol.86 , pp. 385-389
    • Vrolix, M.C.1    Legrand, V.M.2    Reiber, J.H.3
  • 109
    • 0035124829 scopus 로고    scopus 로고
    • Bioactive immobilization of r-hirudin on CVD-coated metallic implant devices
    • Lahann J, Klee D, Pluester W, et al. Bioactive immobilization of r-hirudin on CVD-coated metallic implant devices. Biomaterials. 2001;22:817-826.
    • (2001) Biomaterials , vol.22 , pp. 817-826
    • Lahann, J.1    Klee, D.2    Pluester, W.3
  • 110
    • 0032052722 scopus 로고    scopus 로고
    • Blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition
    • Nan H, Ping Y, Xuan C, et al. Blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition. Biomaterials. 1998;19:771-776.
    • (1998) Biomaterials , vol.19 , pp. 771-776
    • Nan, H.1    Ping, Y.2    Xuan, C.3
  • 111
    • 0034666723 scopus 로고    scopus 로고
    • In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity
    • Gutensohn K, Beythien C, Bau J, et al. In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res. 2000;99:577-585.
    • (2000) Thromb Res , vol.99 , pp. 577-585
    • Gutensohn, K.1    Beythien, C.2    Bau, J.3
  • 112
    • 0031889795 scopus 로고    scopus 로고
    • Silicon carbide-coated stents: Clinical experience in coronary lesions with increased thrombotic risk
    • Heublein B, Özbek C, Pethig K. Silicon carbide-coated stents: clinical experience in coronary lesions with increased thrombotic risk. J Endovasc Surg. 1998;5:32-36.
    • (1998) J Endovasc Surg , vol.5 , pp. 32-36
    • Heublein, B.1    Özbek, C.2    Pethig, K.3
  • 113
    • 0035928759 scopus 로고    scopus 로고
    • Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia
    • Windecker S, Mayer I, De Pasquale G, et al. Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia. Circulation. 2001;104:928-933.
    • (2001) Circulation , vol.104 , pp. 928-933
    • Windecker, S.1    Mayer, I.2    De Pasquale, G.3
  • 114
    • 0036159753 scopus 로고    scopus 로고
    • Local delivery of low-dose docetaxel, a novel microtubule polymerizing agent, reduces neointimal hyperplasia in a balloon-injured rabbit iliac artery model
    • Yasuda S, Noguchi T, Gohda M, et al. Local delivery of low-dose docetaxel, a novel microtubule polymerizing agent, reduces neointimal hyperplasia in a balloon-injured rabbit iliac artery model. Cardiovasc Res. 2002;53:481-486.
    • (2002) Cardiovasc Res , vol.53 , pp. 481-486
    • Yasuda, S.1    Noguchi, T.2    Gohda, M.3
  • 115
    • 0036159635 scopus 로고    scopus 로고
    • New tools for prevention of restenosis could decrease the "oculostento" reflex
    • Sturek M, Reddy HK. New tools for prevention of restenosis could decrease the "oculostento" reflex. Cardiovasc Res. 2002;53:292-293.
    • (2002) Cardiovasc Res , vol.53 , pp. 292-293
    • Sturek, M.1    Reddy, H.K.2
  • 116
    • 0037083145 scopus 로고    scopus 로고
    • Effect of local delivery of L-arginine on in-stent restenosis in humans
    • Suzuki T, Hayase M, Hibi K, et al. Effect of local delivery of L-arginine on in-stent restenosis in humans. Am J Cardiol. 2002;89:363-367.
    • (2002) Am J Cardiol , vol.89 , pp. 363-367
    • Suzuki, T.1    Hayase, M.2    Hibi, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.