메뉴 건너뛰기




Volumn 5030 II, Issue , 2003, Pages 1010-1020

Imaging performance of a clinical selenium flat-panel detector for advanced applications in full-field digital mammography

Author keywords

Direct converter; FFDM; Flat panel; Ghosting; Mammography; Selenium; TACT; Tomosynthesis

Indexed keywords

BIOSYNTHESIS; FLAT PANEL DISPLAYS; IMAGE QUALITY; RADIATION DETECTORS;

EID: 0042877202     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.484075     Document Type: Conference Paper
Times cited : (13)

References (20)
  • 2
    • 0036033208 scopus 로고    scopus 로고
    • Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium
    • Yorker J., Jeromine L., Lee D., Palecki E., Golden K., and Jing Z., "Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium", Proc. SPIE vol. 4682, 2002, pp. 21-29.
    • (2002) Proc. SPIE , vol.4682 , pp. 21-29
    • Yorker, J.1    Jeromine, L.2    Lee, D.3    Palecki, E.4    Golden, K.5    Jing, Z.6
  • 3
    • 0035114759 scopus 로고    scopus 로고
    • Comparison of full-field digital mammography with screen-film mammography for cancer detection: Results of 4,945 paired examinations
    • Lewin J. M., Hendrick R.E., D'Orsi C.J., Isaacs P. K., Moss L.J., Karellas A., Sisney G.A., Kuni C. C., and Cutter G.R., "Comparison of Full-Field Digital Mammography with Screen-Film Mammography for Cancer Detection: Results of 4,945 Paired Examinations", Radiology, vol. 218, 2001, pp. 873- 880.
    • (2001) Radiology , vol.218 , pp. 873-880
    • Lewin, J.M.1    Hendrick, R.E.2    D'Orsi, C.J.3    Isaacs, P.K.4    Moss, L.J.5    Karellas, A.6    Sisney, G.A.7    Kuni, C.C.8    Cutter, G.R.9
  • 4
    • 0036033419 scopus 로고    scopus 로고
    • Contrast enhanced digital mammography (CEDM): Phantom experiment and first clinical results
    • Marx C., Faciusa M., Muller S., Benali K., Malich A., KaiserW.A., "Contrast Enhanced Digital Mammography (CEDM): Phantom experiment and first clinical results", Proc. SPIE vol. 4682, 2002, pp. 174-181.
    • (2002) Proc. SPIE , vol.4682 , pp. 174-181
    • Marx, C.1    Faciusa, M.2    Muller, S.3    Benali, K.4    Malich, A.5    Kaiser, W.A.6
  • 5
    • 0012750736 scopus 로고    scopus 로고
    • Dual-energy contrast protocol offers new tool to detect breast cancer
    • Lewin J.M., "Dual-energy contrast protocol offers new tool to detect breast cancer", Diag. Imaging, 2001.
    • (2001) Diag. Imaging
    • Lewin, J.M.1
  • 7
    • 0031714418 scopus 로고    scopus 로고
    • Digital breast imaging: Tomosynthesis and digital subtraction mammography
    • Niklason L.T., Kopans D. and Hamberg L., "Digital Breast Imaging: Tomosynthesis and Digital Subtraction Mammography", Breast Disease 10(3,4), 1998, pp. 151-164.
    • (1998) Breast Disease , vol.10 , Issue.3-4 , pp. 151-164
    • Niklason, L.T.1    Kopans, D.2    Hamberg, L.3
  • 11
    • 0032402954 scopus 로고    scopus 로고
    • Improved imaging performance of a 14×17-inch direct radiography™ system using Se/TFT detector
    • Lee D.L., Cheung L.K., Rodricks B., and Powell G.F., "Improved imaging performance of a 14×17-inch Direct Radiography™ system using Se/TFT detector", Proc. SPIE, vol. 3336, 1998, pp. 14-23.
    • (1998) Proc. SPIE , vol.3336 , pp. 14-23
    • Lee, D.L.1    Cheung, L.K.2    Rodricks, B.3    Powell, G.F.4
  • 13
    • 0032403040 scopus 로고    scopus 로고
    • Spectral modeling and compilation of quantum fluence in radiography and mammography
    • Boone, J.M., "Spectral modeling and compilation of quantum fluence in radiography and mammography", Proc. SPIE vol. 3336, 1998, pp. 592-601.
    • (1998) Proc. SPIE , vol.3336 , pp. 592-601
    • Boone, J.M.1
  • 14
    • 0034870333 scopus 로고    scopus 로고
    • Temporal artifacts in flat dynamic x-ray detectors
    • Overdick M., Soif T., Wischmann H., "Temporal artifacts in flat dynamic x-ray detectors", Proc. SPIE vol. 4320, 2001, pp. 47-58.
    • (2001) Proc. SPIE , vol.4320 , pp. 47-58
    • Overdick, M.1    Soif, T.2    Wischmann, H.3
  • 15
    • 0032772594 scopus 로고    scopus 로고
    • A ghost story: Spatio-temporal response characteristics of an indirect-detector flat-panel imager
    • Siewerdson J.H., and Jaffray D.Â., "A ghost story: spatio-temporal response characteristics of an indirect-detector flat-panel imager", Med. Phys., 26,1999, pp.1624-1641.
    • (1999) Med. Phys. , vol.26 , pp. 1624-1641
    • Siewerdson, J.H.1    Jaffray, D.Â.2
  • 16
    • 0034873663 scopus 로고    scopus 로고
    • Fast imaging of a 41cm amorphous silicon flat-panel detector for radiographic applications
    • Kump K., "Fast imaging of a 41cm amorphous silicon flat-panel detector for radiographic applications", Proc. SPIE vol. 4320, 2001, pp. 87-93.
    • (2001) Proc. SPIE , vol.4320 , pp. 87-93
    • Kump, K.1
  • 17
    • 0033458079 scopus 로고    scopus 로고
    • Cone-beam computed tomography with flat-panel imager: Effects of image lag
    • Siewerdsen J.H. and Jaffray D.A., "Cone-beam computed tomography with flat-panel imager: effects of image lag", Med. Phys., vol., 26(12), 1999, pp. 2635-2647.
    • (1999) Med. Phys. , vol.26 , Issue.12 , pp. 2635-2647
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 20
    • 0033625447 scopus 로고    scopus 로고
    • A controlled evaluation of tuned-aperture computed tomography applied to digital spot mammography
    • Webber R.L., Underbill H.R., Freimanis R.I., "A controlled evaluation of tuned-aperture computed tomography applied to digital spot mammography", J. Digit Imaging, 13(2), 2000, pp. 90-97.
    • (2000) J. Digit Imaging , vol.13 , Issue.2 , pp. 90-97
    • Webber, R.L.1    Underbill, H.R.2    Freimanis, R.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.