Volumn 14, Issue 3, 1999, Pages 337-341

Numerical analysis of a dental implant system preloaded with a washer

Author keywords

Dental implant; Finite element analysis; Screw loosening; Stiffness; Washer

Indexed keywords

ARTICLE; DENTAL CARE; DENTAL EQUIPMENT; DENTURE; FINITE ELEMENT ANALYSIS; HUMAN; INSTRUMENTATION; MATHEMATICAL COMPUTING; TOOTH IMPLANTATION; TOOTH PROSTHESIS;

EID: 0033127574     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (25)

References (8)
  • 1
    • 0029262468 scopus 로고
    • Brånemark single-tooth implants: A preliminary report of 76 implants
    • Haas R, Mensdorff-Pouilly N, Mailath G, Watzek G. Brånemark single-tooth implants: A preliminary report of 76 implants. J Prosthet Dent 1995;73: 274-279.
    • (1995) J Prosthet Dent , vol.73 , pp. 274-279
    • Haas, R.1    Mensdorff-Pouilly, N.2    Mailath, G.3    Watzek, G.4
  • 3
    • 0030275656 scopus 로고    scopus 로고
    • The effect of eliminating implant/ abutment rotational misfit on screw joint stability
    • Binon PP, McHugh MJ. The effect of eliminating implant/ abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9: 511-519.
    • (1996) Int J Prosthodont , vol.9 , pp. 511-519
    • Binon, P.P.1    McHugh, M.J.2
  • 4
    • 0026167259 scopus 로고
    • Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study
    • Rangert B, Gunne J, Sullivan DY. Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study. Int J Oral Maxillofac Implants 1991;6: 177-186.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 177-186
    • Rangert, B.1    Gunne, J.2    Sullivan, D.Y.3
  • 5
    • 0029302999 scopus 로고
    • Nonlinear contact analysis of preload in dental implant screws
    • Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995;10: 295-302.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 295-302
    • Sakaguchi, R.L.1    Borgersen, S.E.2
  • 6
    • 0027829234 scopus 로고
    • Nonlinear finite element contact analysis of dental implant components
    • Sakaguchi RL, Borgersen SE. Nonlinear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants 1993;8: 655-661.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 655-661
    • Sakaguchi, R.L.1    Borgersen, S.E.2