메뉴 건너뛰기




Volumn 40, Issue 4, 1998, Pages 967-976

Electronic portal imaging with on-line correction of setup error in thoracic irradiation: Clinical evaluation

Author keywords

Decision rules; EPID; Lung tumors; Quality control; Setup errors

Indexed keywords

ARTICLE; CANCER LOCALIZATION; CLINICAL ARTICLE; DIAGNOSTIC IMAGING; HUMAN; IMAGE QUALITY; LUNG CANCER; LUNG TUMOR; PRIORITY JOURNAL; QUALITY CONTROL;

EID: 0031895830     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(97)00925-5     Document Type: Article
Times cited : (96)

References (18)
  • 3
    • 0028587612 scopus 로고
    • In vivo determination of the accuracy of field matching in breast cancer irradiation using an electronic portal imaging device
    • Holmberg O., Huizinga H., Idzes M. H., Lebesque J. V., Vijlbrief R. E., Mijnheer B. J. In vivo determination of the accuracy of field matching in breast cancer irradiation using an electronic portal imaging device. Radiother. Oncol. 33:1994;157-166.
    • (1994) Radiother. Oncol. , vol.33 , pp. 157-166
    • Holmberg, O.1    Huizinga, H.2    Idzes, M.H.3    Lebesque, J.V.4    Vijlbrief, R.E.5    Mijnheer, B.J.6
  • 5
    • 0028000146 scopus 로고
    • The utility of the Philips SRI-100 Real Time Portal Imaging Device in case of postoperative irradiation for prevention of heterotopic bone formation following total hip replacement
    • Kiffer J. D., Quong G., Bergman N. R., Lawlor M., Schumer W., Aitken L., Wallace A. The utility of the Philips SRI-100 Real Time Portal Imaging Device in case of postoperative irradiation for prevention of heterotopic bone formation following total hip replacement. Aust. Radiol. 38:1994;342-344.
    • (1994) Aust. Radiol. , vol.38 , pp. 342-344
    • Kiffer, J.D.1    Quong, G.2    Bergman, N.R.3    Lawlor, M.4    Schumer, W.5    Aitken, L.6    Wallace, A.7
  • 9
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    • van Herk M., Bruce A., Kroes A., Shouman T., Touw A., Lebesque J. Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. Int. J. Radiat. Oncol. Biol. Phys. 33:1995;1311-1320.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 1311-1320
    • Van Herk, M.1    Bruce, A.2    Kroes, A.3    Shouman, T.4    Touw, A.5    Lebesque, J.6
  • 11
    • 0029996627 scopus 로고    scopus 로고
    • High-precision prostate cancer irradiation by clinical application of an off-line patient set up verification procedure, using portal imaging
    • Bel A., Vos P. H., Rodrigus P-T. R., et al. High-precision prostate cancer irradiation by clinical application of an off-line patient set up verification procedure, using portal imaging. Int. J. Radiat. Oncol. Biol. Phys. 35:1996;321-332.
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.35 , pp. 321-332
    • Bel, A.1    Vos, P.H.2    Rodrigus P-T., R.3
  • 14
    • 0025631579 scopus 로고
    • A digital video system for on-line portal verification
    • Bellingham, WA: The International Society for Optical Engineering
    • Leszczynski K. W., Shalev S., Cosby S. A digital video system for on-line portal verification. Medical imaging IV Image formation SPIE 1231 . 1990;401-405 The International Society for Optical Engineering, Bellingham, WA.
    • (1990) Medical Imaging IV: Image Formation SPIE 1231 , pp. 401-405
    • Leszczynski, K.W.1    Shalev, S.2    Cosby, S.3
  • 16
    • 0028998318 scopus 로고
    • Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging
    • Van den Heuvel F., De Neve W., Verellen D., Coghe M., Coen V., Storme G. Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging. Radiother. Oncol. 35:1995;232-239.
    • (1995) Radiother. Oncol. , vol.35 , pp. 232-239
    • Van Den Heuvel, F.1    De Neve, W.2    Verellen, D.3    Coghe, M.4    Coen, V.5    Storme, G.6
  • 17
    • 0028785762 scopus 로고
    • Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device
    • Bel A., Keus R., Vijlbrief R. E., Lebesque J. V. Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device. Radiother. Oncol. 37:1995;153-159.
    • (1995) Radiother. Oncol. , vol.37 , pp. 153-159
    • Bel, A.1    Keus, R.2    Vijlbrief, R.E.3    Lebesque, J.V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.