메뉴 건너뛰기




Volumn 37, Issue 1, 1997, Pages 199-204

Benchmark test cases for evaluation of computer-based methods for detection of setup errors: Realistic digitally reconstructed electronic portal images with known setup errors

Author keywords

digitally reconstructed radiographs; image registration; portal imaging; treatment verification

Indexed keywords

ARTICLE; CANCER DIAGNOSIS; COMPUTER SIMULATION; DEVICE; DIAGNOSTIC ERROR; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; NONHUMAN; PORTAL VEIN BLOOD FLOW; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING;

EID: 0031054189     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(96)00479-8     Document Type: Article
Times cited : (11)

References (14)
  • 1
    • 0026652740 scopus 로고
    • Correlation of projection radiographs in radiation therapy using open curve segments and points
    • Balter, J. M.; Pelizzari, C. A.; Chen, G. T. Y. Correlation of projection radiographs in radiation therapy using open curve segments and points. Med. Phys. 19:329-334; 1992.
    • (1992) Med. Phys. , vol.19 , pp. 329-334
    • Balter, J.M.1    Pelizzari, C.A.2    Chen, G.T.Y.3
  • 3
    • 0028129772 scopus 로고
    • A Monte Carlo study of accelerator head scatter
    • Chaney, E. L.; Cullip, T. J.; Gabriel, T. A. A Monte Carlo study of accelerator head scatter. Med. Phys, 21(9): 1383-1390; 1994.
    • (1994) Med. Phys , vol.21 , Issue.9 , pp. 1383-1390
    • Chaney, E.L.1    Cullip, T.J.2    Gabriel, T.A.3
  • 7
    • 0027141139 scopus 로고
    • An algorithm for automatic analysis of portal images: Clinical evaluation for prostate treatments
    • Gilhuijs, K. G. A.; El-Gayed, A. A. H.; van Herk, M.; Vijlbrief, R. E. An algorithm for automatic analysis of portal images: Clinical evaluation for prostate treatments. Radiother. Oncol. 29:261-268; 1993.
    • (1993) Radiother. Oncol. , vol.29 , pp. 261-268
    • Gilhuijs, K.G.A.1    El-Gayed, A.A.H.2    Van Herk, M.3    Vijlbrief, R.E.4
  • 8
    • 0029079996 scopus 로고
    • Optimization of automatic portal image analysis
    • Gilhuijs, K. G. A.; Touw, A.; van Herk, M.; Vijlbrief, R. E. Optimization of automatic portal image analysis. Med. Phys. 22(7):1077-1088; 1995.
    • (1995) Med. Phys. , vol.22 , Issue.7 , pp. 1077-1088
    • Gilhuijs, K.G.A.1    Touw, A.2    Van Herk, M.3    Vijlbrief, R.E.4
  • 9
    • 0027278542 scopus 로고
    • Automatic on-line inspection of patient setup in radiation therapy using digital portal images
    • Gilhuijs, K. G. A.; van Herk, M. Automatic on-line inspection of patient setup in radiation therapy using digital portal images. Med. Phys. 20:667-678; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 667-678
    • Gilhuijs, K.G.A.1    Van Herk, M.2
  • 10
    • 0025836884 scopus 로고
    • Investigation of a FFT-based correlation technique for verification of radiation treatment setup
    • Jones, S. M.; Boyer, A. L. Investigation of a FFT-based correlation technique for verification of radiation treatment setup. Med. Phys. 18:1116-1125; 1991.
    • (1991) Med. Phys. , vol.18 , pp. 1116-1125
    • Jones, S.M.1    Boyer, A.L.2
  • 11
    • 0029900134 scopus 로고    scopus 로고
    • A quality control test for electronic portal imaging devices
    • Rajapakshe, R.; Luchka, K. B.; Shalev, S. A quality control test for electronic portal imaging devices. Med. Phys. 23(7):1237-1244; 1996.
    • (1996) Med. Phys. , vol.23 , Issue.7 , pp. 1237-1244
    • Rajapakshe, R.1    Luchka, K.B.2    Shalev, S.3
  • 13
    • 0002283081 scopus 로고
    • Treatment verification using digital imaging
    • Smith, A. R., ed. Berlin: Springer Verlag
    • Shalev, S. Treatment verification using digital imaging. In: Smith, A. R., ed. Medical radiology: Radiation therapy physics. Berlin: Springer Verlag; 1995:155-173.
    • (1995) Medical Radiology: Radiation Therapy Physics , pp. 155-173
    • Shalev, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.