메뉴 건너뛰기




Volumn 34, Issue 2, 1996, Pages 489-495

Quantitative vs. subjective portal verification using digital portal images

Author keywords

Edge extraction; Image registration; Portal imaging; Radiotherapy

Indexed keywords

ARTICLE; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER PROGRAM; DIGITAL RADIOGRAPHY; ERROR; HUMAN; IMAGE ANALYSIS; IMAGING SYSTEM; OBSERVER VARIATION; PRIORITY JOURNAL; RADIATION FIELD; TELEVISION CAMERA;

EID: 0030054268     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/0360-3016(95)02035-7     Document Type: Article
Times cited : (21)

References (15)
  • 1
    • 0025932046 scopus 로고
    • Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images
    • Bijhold, J.; van Herk, M.; Vijlbrief, R.; Lebesque, J. V. Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images. Phys. Med. Biol. 36:1665-1679; 1991.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 1665-1679
    • Bijhold, J.1    Van Herk, M.2    Vijlbrief, R.3    Lebesque, J.V.4
  • 4
    • 0010990601 scopus 로고
    • Dosimetric precision requirements in radiation therapy
    • Brahme, A. Dosimetric precision requirements in radiation therapy. Acta Radiol. Oncol. 23:379-391; 1984.
    • (1984) Acta Radiol. Oncol. , vol.23 , pp. 379-391
    • Brahme, A.1
  • 7
    • 0027278542 scopus 로고
    • Automatic on-line inspection of patient set-up in radiation therapy using digital portal images
    • Gilhuijs, K. G. A.; van Herk, M. Automatic on-line inspection of patient set-up in radiation therapy using digital portal images. Med. Phys. 20:667-677; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 667-677
    • Gilhuijs, K.G.A.1    Van Herk, M.2
  • 8
    • 0016711604 scopus 로고
    • Immobilization error: Some theoretical considerations
    • Goitein, M. Immobilization error: Some theoretical considerations. Radiology 117:407-412; 1975.
    • (1975) Radiology , vol.117 , pp. 407-412
    • Goitein, M.1
  • 9
    • 0025836884 scopus 로고
    • Investigation of an FFT-based correlation technique for verification of radiation treatment setup
    • Jones, S. M.; Boyer, A. L. Investigation of an FFT-based correlation technique for verification of radiation treatment setup. Med. Phys. 18:1116-1125; 1991.
    • (1991) Med. Phys. , vol.18 , pp. 1116-1125
    • Jones, S.M.1    Boyer, A.L.2
  • 10
    • 0027373961 scopus 로고
    • A comparative study of methods for the registration of pairs of radiation fields
    • Leszczynski, K.; Loose, S.; Dunscombe, P. A comparative study of methods for the registration of pairs of radiation fields. Phys. Med. Biol. 38:1-10; 1993.
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1-10
    • Leszczynski, K.1    Loose, S.2    Dunscombe, P.3
  • 12
    • 0027158786 scopus 로고
    • Uncertainty analysis of field placement error measurements using digital portal and simulation image correlations
    • McParland, B. J. Uncertainty analysis of field placement error measurements using digital portal and simulation image correlations. Med. Phys. 20:679-685; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 679-685
    • McParland, B.J.1
  • 13
    • 0025191363 scopus 로고
    • A method for the measurement of field placement errors in digital portal images
    • Meertens, H.; Bijhold, J.; Strackee, J. A method for the measurement of field placement errors in digital portal images. Phys. Med. Biol. 35:299-323; 1990.
    • (1990) Phys. Med. Biol. , vol.35 , pp. 299-323
    • Meertens, H.1    Bijhold, J.2    Strackee, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.