메뉴 건너뛰기




Volumn 34, Issue 3, 1996, Pages 683-690

An analysis of intratreatment and intertreatment displacements in pelvic radiotherapy using electronic portal imaging

Author keywords

Electronic portal imaging; Intratreatment and intertreatment displacements; Pelvic radiotherapy

Indexed keywords

ARTICLE; CANCER RADIOTHERAPY; CLINICAL ARTICLE; HUMAN; IATROGENIC DISEASE; IMAGE ANALYSIS; PATIENT POSITIONING; PRIORITY JOURNAL; RECTUM CANCER;

EID: 0030032525     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/0360-3016(95)02057-8     Document Type: Article
Times cited : (35)

References (27)
  • 1
    • 0026745010 scopus 로고
    • Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer
    • Bijhold, J.; Lebesque, J. V.; Hart, A. A. M.; Vijlbrief, R. E. Maximizing setup accuracy using portal images as applied to a conformal boost technique for prostatic cancer. Radiother. Oncol. 24:261-271; 1992.
    • (1992) Radiother. Oncol. , vol.24 , pp. 261-271
    • Bijhold, J.1    Lebesque, J.V.2    Hart, A.A.M.3    Vijlbrief, R.E.4
  • 4
    • 0021709127 scopus 로고
    • When and how can we improve precision in radiotherapy?
    • Dutreix, A. When and how can we improve precision in radiotherapy? Radiat. Oncol. 2:275-292; 1984.
    • (1984) Radiat. Oncol. , vol.2 , pp. 275-292
    • Dutreix, A.1
  • 6
    • 0025925044 scopus 로고
    • Study of treatment variation in the radiotherapy of head and neck tumors using a fiber-optic on-line radiotherapy imaging system
    • Halverson, K. J.; Leung, T. C.; Pellett, J. B.; Gerber, R. L.; Weinhous, M. S.; Wong, J. W. Study of treatment variation in the radiotherapy of head and neck tumors using a fiber-optic on-line radiotherapy imaging system. Int. J. Radiat. Oncol. Biol. Phys. 21:1327-1336; 1991.
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.21 , pp. 1327-1336
    • Halverson, K.J.1    Leung, T.C.2    Pellett, J.B.3    Gerber, R.L.4    Weinhous, M.S.5    Wong, J.W.6
  • 7
    • 0015715975 scopus 로고
    • Detection and evaluation of localization errors in patient radiation therapy
    • Haus, A. G.; Marks, J. E. Detection and evaluation of localization errors in patient radiation therapy. Invest. Radiol. 8:384-391; 1973.
    • (1973) Invest. Radiol. , vol.8 , pp. 384-391
    • Haus, A.G.1    Marks, J.E.2
  • 8
    • 0015351128 scopus 로고
    • Measurement of patient movement during radiation therapy
    • Kelsey, C. A.; Lane, R. G.; Connor, W. G. Measurement of patient movement during radiation therapy. Radiology 103:697-698; 1972.
    • (1972) Radiology , vol.103 , pp. 697-698
    • Kelsey, C.A.1    Lane, R.G.2    Connor, W.G.3
  • 9
    • 0024843698 scopus 로고
    • Reproducibility of field alignment in radiation therapy. A large scale clinical experience
    • Kihlen, B.; Ruden, B. I. Reproducibility of field alignment in radiation therapy. A large scale clinical experience. Acta Oncol. 28:689-692; 1989.
    • (1989) Acta Oncol. , vol.28 , pp. 689-692
    • Kihlen, B.1    Ruden, B.I.2
  • 10
    • 0021063113 scopus 로고
    • Patterns of care study: Hodgkin's disease relapse rates and adequacy of portals
    • Kinzie, J. J.; Hanks, G. E.; Maclean, C. J.; Kramer, S. Patterns of Care Study: Hodgkin's disease relapse rates and adequacy of portals. Cancer 52:2223-2226; 1983.
    • (1983) Cancer , vol.52 , pp. 2223-2226
    • Kinzie, J.J.1    Hanks, G.E.2    Maclean, C.J.3    Kramer, S.4
  • 12
    • 0023090552 scopus 로고
    • On-line measurement of field placement errors in external beam radiotherapy
    • Lam, W. C.; Partowmah, M.; Lee, D. J.; Wharam, M. D.; Lam, K. S. On-line measurement of field placement errors in external beam radiotherapy. Br. J. Radiol. 60:360-367; 1987.
    • (1987) Br. J. Radiol. , vol.60 , pp. 360-367
    • Lam, W.C.1    Partowmah, M.2    Lee, D.J.3    Wharam, M.D.4    Lam, K.S.5
  • 13
    • 0016207636 scopus 로고
    • Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields
    • Marks, J. E.; Haus, A. G.; Sutton, H. G.; Griem, M. L. Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields. Cancer 34:83-90; 1974.
    • (1974) Cancer , vol.34 , pp. 83-90
    • Marks, J.E.1    Haus, A.G.2    Sutton, H.G.3    Griem, M.L.4
  • 14
    • 0017187996 scopus 로고
    • The effect of immobilisation on localisation error in the radiotherapy of head and neck cancer
    • Marks, J. E.; Haus, A. G. The effect of immobilisation on localisation error in the radiotherapy of head and neck cancer. Clin. Radiol. 27:175-177; 1976.
    • (1976) Clin. Radiol. , vol.27 , pp. 175-177
    • Marks, J.E.1    Haus, A.G.2
  • 15
    • 0017133803 scopus 로고
    • The value of frequent treatment verification films in reducing localization error in the irradiation of complex fields
    • Marks, J. E.; Haus, A. G.; Sutton, H. G.; Griem, M. L. The value of frequent treatment verification films in reducing localization error in the irradiation of complex fields. Cancer 37:2755-2761; 1976.
    • (1976) Cancer , vol.37 , pp. 2755-2761
    • Marks, J.E.1    Haus, A.G.2    Sutton, H.G.3    Griem, M.L.4
  • 21
    • 0021329574 scopus 로고
    • Patient movements during radiotherapy
    • Norwood, H. M.; Stubbs, B. Patient movements during radiotherapy. Br. J. Radiol. 57:155-158; 1984.
    • (1984) Br. J. Radiol. , vol.57 , pp. 155-158
    • Norwood, H.M.1    Stubbs, B.2
  • 25
    • 0026065211 scopus 로고
    • Conformal static field therapy for low volume low grade prostate cancer with rigid immobilization
    • Soffen, E. M.; Hanks, E. G.; Hwang, C. C.; Chu, J. C. H. Conformal static field therapy for low volume low grade prostate cancer with rigid immobilization. Int. J. Radiat. Oncol. Biol. Phys. 20:141-146; 1991.
    • (1991) Int. J. Radiat. Oncol. Biol. Phys. , vol.20 , pp. 141-146
    • Soffen, E.M.1    Hanks, E.G.2    Hwang, C.C.3    Chu, J.C.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.