-
1
-
-
0022719492
-
-
1986.
-
J.A. Malko, R. L. Van Heertum, G, T. Gullberg, and W. P. Kowalsky, "SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source," J Nucl Med, vol. 27, pp. 701-705, 1986.
-
R. L. Van Heertum, G, T. Gullberg, and W. P. Kowalsky, "SPECT Liver Imaging Using an Iterative Attenuation Correction Algorithm and an External Flood Source," J Nucl Med, Vol. 27, Pp. 701-705
-
-
Malko, J.A.1
-
2
-
-
0344071788
-
-
1988.
-
S, H. Manglos, R. J. Jaszczak, and C. E. Floyd, "Weighted backprojeclion implemented with a non-uniform attenuation map for improved SPECT quamitation," IEEE Tntns, Nucl Sei, vol. NS-35, pp. 625-628, 1988.
-
R. J. Jaszczak, and C. E. Floyd, "Weighted Backprojeclion Implemented with a Non-uniform Attenuation Map for Improved SPECT Quamitation," IEEE Tntns, Nucl Sei, Vol. NS-35, Pp. 625-628
-
-
Manglos, S.H.1
-
3
-
-
0019947080
-
-
1982.
-
S.C. Moore, J. A. Brunelle, and C, M. Kirsch, "Quantitative mullidetector emission computerized lomography using iterative attenuation compensation," J Nucl Med, vol. 23, pp. 706-714, 1982.
-
J. A. Brunelle, and C, M. Kirsch, "Quantitative Mullidetector Emission Computerized Lomography Using Iterative Attenuation Compensation," J Nucl Med, Vol. 23, Pp. 706-714
-
-
Moore, S.C.1
-
4
-
-
0024500736
-
-
1989.
-
B, M. W. Tsui, G. T. Gullberg, E. R. Edgerton, J. G. Billiard, J R. Perry, W. H. MeCarlncy, ami J. Berg, "Correction of nominiform attenuation in cardiac SPECT imaging," J Nucl Med, vol. 30, pp. 497-507, 1989.
-
G. T. Gullberg, E. R. Edgerton, J. G. Billiard, J R. Perry, W. H. MeCarlncy, Ami J. Berg, "Correction of Nominiform Attenuation in Cardiac SPECT Imaging," J Nucl Med, Vol. 30, Pp. 497-507
-
-
Tsui, B.M.W.1
-
5
-
-
0026460467
-
-
1992.
-
E.C. Frey, B. M. W, Tsui, and J. R. Perry, "Simultaneous acquisition of emission and transmission data for improved Thallium-201 cardiac SPECT imaging using a Tcchnetium-99m transmission source," J Nucl Med, vol. 33, pp. 2238-2245, 1992.
-
B. M. W, Tsui, and J. R. Perry, "Simultaneous Acquisition of Emission and Transmission Data for Improved Thallium-201 Cardiac SPECT Imaging Using a Tcchnetium-99m Transmission Source," J Nucl Med, Vol. 33, Pp. 2238-2245
-
-
Frey, E.C.1
-
6
-
-
0026902682
-
-
1134-1143, I'J92.
-
C.-H. Tung, G. T. Gullberg, G. L. Zcng, P. E. Christian, F. L. Datz, and H. T. Morgan, "Non-uniform attenuation correction using simultaneous transmission and emission converging tomography," lEEETransNuclSci, vol. 39, pp. 1134-1143, I'J92.
-
G. T. Gullberg, G. L. Zcng, P. E. Christian, F. L. Datz, and H. T. Morgan, "Non-uniform Attenuation Correction Using Simultaneous Transmission and Emission Converging Tomography," LEEETransNuclSci, Vol. 39, Pp.
-
-
Tung, C.-H.1
-
7
-
-
0021327145
-
-
1984.
-
K. Lange and K. Carson, "EM reconstruction algorithms for emission and transmission tomography," J Camp Aasist Tamtigr, vol. 8, pp. 306-316, 1984.
-
"EM Reconstruction Algorithms for Emission and Transmission Tomography," J Camp Aasist Tamtigr, Vol. 8, Pp. 306-316
-
-
Lange, K.1
Carson, K.2
-
8
-
-
0020194763
-
-
1982
-
L.A. Shcpp and Y. Vardi, "Maximum likelihood estimation for emission tomography," IEEE Trans Med [in, vol. MI-1, pp. 113-121, 1982,
-
"Maximum Likelihood Estimation for Emission Tomography," IEEE Trans Med In, Vol. MI-1, Pp. 113-121
-
-
Shcpp, L.A.1
Vardi, Y.2
-
10
-
-
0028700063
-
-
1994.
-
H, M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Tnmn Med Im, vol. 13, pp. 601-609, 1994.
-
And R. S. Larkin, "Accelerated Image Reconstruction Using Ordered Subsets of Projection Data," IEEE Tnmn Med Im, Vol. 13, Pp. 601-609
-
-
Hudson, M.1
-
11
-
-
0028711560
-
-
1994.
-
E. U. Mumcuoglu, K. Leahy, S. R. Cherry, and Z. Zhou, "Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images," IEEE Trans Med 1m, vol. 13, pp. 687-701, 1994.
-
K. Leahy, S. R. Cherry, and Z. Zhou, "Fast Gradient-based Methods for Bayesian Reconstruction of Transmission and Emission PET Images," IEEE Trans Med 1m, Vol. 13, Pp. 687-701
-
-
Mumcuoglu, U.1
-
12
-
-
0029020079
-
-
1225-1241,1995.
-
S. H. 'Manglos, G. M. Gagne, A. Kral, V. D. Thoraas, and R. Narayanaswamy, "Transmission maximum-likelihood reconstruction with ordered subsets for cone-beam CT," Phys Med Dial, vol. 40, pp. 1225-1241,1995.
-
G. M. Gagne, A. Kral, V. D. Thoraas, and R. Narayanaswamy, "Transmission Maximum-likelihood Reconstruction with Ordered Subsets for Cone-beam CT," Phys Med Dial, Vol. 40, Pp.
-
-
Manglos, H.1
-
13
-
-
0032216626
-
-
1998.
-
C, Kamphuis and F, J. Bookman, "Accelerated iterative transmission CT using an ordered subsets convex algorithm," IEEE Trans Med Im, vol, 17, pp. 1101-1105, 1998.
-
F, J. Bookman, "Accelerated Iterative Transmission CT Using an Ordered Subsets Convex Algorithm," IEEE Trans Med Im, Vol, 17, Pp. 1101-1105
-
-
Kamphuis1
-
15
-
-
0029394375
-
-
1995.
-
K. Lange and 1. A, Fessier, "Globally convergent algorithms for maximum a posteriori transmission tomography," IEEE Trans Im Proc, vol. 4, pp. 1430-1438, 1995.
-
1. A, Fessier, "Globally Convergent Algorithms for Maximum a Posteriori Transmission Tomography," IEEE Trans Im Proc, Vol. 4, Pp. 1430-1438
-
-
-
16
-
-
10344255031
-
-
1988.
-
C. E. Metz find C.-T, Chen, "On the acceleration of maximum likelihood algorithms," Proc SPIK, vol. 914, pp. 344-349, 1988.
-
Find C.-T, Chen, "On the Acceleration of Maximum Likelihood Algorithms," Proc SPIK, Vol. 914, Pp. 344-349
-
-
Metz, E.1
-
17
-
-
0023363121
-
-
1987.
-
K. Lange, M. Bahn, and R. Little, "A theoretical study of some maximum likelihood algorithms for emission and transmission tomography," IEEE Trans Med Im. vol. Ml-fi, pp. 106-114, 1987.
-
Bahn, and R. Little, "A Theoretical Study of some Maximum Likelihood Algorithms for Emission and Transmission Tomography," IEEE Trans Med Im. Vol. Ml-fi, Pp. 106-114
-
-
Lange, M.1
-
18
-
-
0023314408
-
-
1987.
-
L, Kaufman, "Implementing and accelerating the EM algorithm for positron emission tomography," IEEE Tiens Med Im, vol. MI-6, pp. 37-51, 1987.
-
And Accelerating the EM Algorithm for Positron Emission Tomography," IEEE Tiens Med Im, Vol. MI-6, Pp. 37-51
-
-
Kaufman, T.1
-
19
-
-
0022683404
-
-
1986.
-
R. M. Levvitl and G. Muehllelmer, "Accelerated iterative reconstruction for positron emission tomography based on the EM algorithm for maximum likelihood estimation," IEKK Trans Med Im, vol. MI-5, pp. 16-22, 1986.
-
And G. Muehllelmer, "Accelerated Iterative Reconstruction for Positron Emission Tomography Based on the EM Algorithm for Maximum Likelihood Estimation," IEKK Trans Med Im, Vol. MI-5, Pp. 16-22
-
-
Levvitl, M.1
-
20
-
-
0027842861
-
-
1993.
-
B.M. W. Tsui, J. A. Terry, and G. T. Gullberg, "Evaluation of cardiac cone-beam Single Photon Emission Computed Tomography using observer performance experiments and receiver operating characteristic analysis," Invest Radiol, vol. 28, pp. 1101-1112, 1993.
-
Tsui, J. A. Terry, and G. T. Gullberg, "Evaluation of Cardiac Cone-beam Single Photon Emission Computed Tomography Using Observer Performance Experiments and Receiver Operating Characteristic Analysis," Invest Radiol, Vol. 28, Pp. 1101-1112
-
-
-
22
-
-
0034105213
-
-
2000.
-
D. S. Liilush and B. M. W. Tsni, "Performance of ordered-subsct reconstruction algorithms under conditions of extreme attenuation and truncation in cardiac SPECT," J Nucl Med, vol. 41, in press, 2000.
-
And B. M. W. Tsni, "Performance of Ordered-subsct Reconstruction Algorithms under Conditions of Extreme Attenuation and Truncation in Cardiac SPECT," J Nucl Med, Vol. 41, in Press
-
-
Liilush, S.1
|