메뉴 건너뛰기




Volumn 13, Issue 4, 1994, Pages 601-609

Accelerated Image Reconstruction Using Ordered Subsets of Projection Data

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; CONVERGENCE OF NUMERICAL METHODS; DATA PROCESSING; DATA STRUCTURES; ESTIMATION; IMAGE QUALITY; ITERATIVE METHODS; POSITRON EMISSION TOMOGRAPHY;

EID: 0028700063     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.363108     Document Type: Article
Times cited : (3055)

References (19)
  • 1
    • 0002416978 scopus 로고
    • Iterative algorithms for large partitioned linear systems, with applications to image reconstruction
    • P. P. B. Eggermont, G. T. Herman, and A. Lent, “Iterative algorithms for large partitioned linear systems, with applications to image reconstruction,” Linear Algebra and Its Applicat., vol. 40, pp. 37-67, 1981.
    • (1981) Linear Algebra and Its Applicat. , vol.40 , pp. 37-67
    • Eggermont, P.P.B.1    Herman, G.T.2    Lent, A.3
  • 2
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi, “Maximum likelihood reconstruction for emission tomography,” IEEE Trans. Med. Imag., vol. MI-2, pp. 113-122, 1982.
    • (1982) IEEE Trans. Med. Imag. , vol.MI-2 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 3
    • 0024681039 scopus 로고
    • A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
    • T. Hebert and R. Leahy, “A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors,” IEEE Trans. Med. Imag., vol. 8, pp. 194-202, 1989.
    • (1989) IEEE Trans. Med. Imag. , vol.8 , pp. 194-202
    • Hebert, T.1    Leahy, R.2
  • 4
    • 0025404969 scopus 로고
    • Bayesian reconstruction from emission tomography data using a modified EM algorithm
    • P. J. Green, “Bayesian reconstruction from emission tomography data using a modified EM algorithm,” IEEE Trans. Med. Imag., vol. 9, pp. 84-93, 1990.
    • (1990) IEEE Trans. Med. Imag. , vol.9 , pp. 84-93
    • Green, P.J.1
  • 6
    • 0023314408 scopus 로고
    • Implementing and accelerating the EM algorithm for Positron Emission Tomography
    • L. Kaufman, “Implementing and accelerating the EM algorithm for Positron Emission Tomography,” IEEE Trans. Med. Imag., vol. MI-6, pp. 37-51, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.MI-6 , pp. 37-51
    • Kaufman, L.1
  • 8
    • 0001593436 scopus 로고
    • Recursive parameter estimation using incomplete data
    • D. M. Titterington, “Recursive parameter estimation using incomplete data,” J. Royal Statist. Soc., B, vol. 46, pp. 251-261, 1984.
    • (1984) J. Royal Statist. Soc. , vol.46 , pp. 251-261
    • Titterington, D.M.1
  • 9
    • 0014905513 scopus 로고
    • Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and X-ray photography
    • R. Gordon, R. Bender, and G. T. Herman, “Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and X-ray photography,” J. Theor. Biol., vol. 29, pp. 471-481, 1970.
    • (1970) J. Theor. Biol. , vol.29 , pp. 471-481
    • Gordon, R.1    Bender, R.2    Herman, G.T.3
  • 10
    • 0001573124 scopus 로고
    • Generalized iterative scaling for log-linear models
    • J. N. Darroch and D. Ratcliff, “Generalized iterative scaling for log-linear models,” Ann. Math. Statist., vol. 43, pp. 1470-1480, 1972.
    • (1972) Ann. Math. Statist. , vol.43 , pp. 1470-1480
    • Darroch, J.N.1    Ratcliff, D.2
  • 11
    • 0013532014 scopus 로고
    • On block-iterative entropy maximization
    • Y. Censor and J. Segman, “On block-iterative entropy maximization,” J. Inform. Optimization Sci., vol. 8, pp. 275-291, 1987.
    • (1987) J. Inform. Optimization Sci. , vol.8 , pp. 275-291
    • Censor, Y.1    Segman, J.2
  • 12
    • 44049112905 scopus 로고
    • A primal-dual iterative algorithm for a maximum likelihood estimation problem
    • and Data Analysis
    • A. N. Iusem and M. Teboulle, “A primal-dual iterative algorithm for a maximum likelihood estimation problem,” Computational Statist, and Data Analysis, vol. 14, pp. 443-456, 1992.
    • (1992) Computational Statist , vol.14 , pp. 443-456
    • Iusem, A.N.1    Teboulle, M.2
  • 13
    • 0015372442 scopus 로고
    • Iterative methods for the three-dimensional reconstruction of an object from its projections
    • P. Gilbert, “Iterative methods for the three-dimensional reconstruction of an object from its projections,” J. Theor. Biol., vol. 36, pp. 105-117, 1972.
    • (1972) J. Theor. Biol. , vol.36 , pp. 105-117
    • Gilbert, P.1
  • 14
    • 0020718577 scopus 로고
    • Finite series-expansion reconstruction methods
    • Y. Censor, “Finite series-expansion reconstruction methods,” Proc. IEEE, vol. 71, no. 3, pp. 409-419, 1983.
    • (1983) Proc. IEEE , vol.71 , Issue.3 , pp. 409-419
    • Censor, Y.1
  • 15
    • 0000357775 scopus 로고
    • On use of the EM algorithm for penalized likelihood estimation
    • P. J. Green, “On use of the EM algorithm for penalized likelihood estimation,” J. Royal Statist. Soc., B, vol. 52, no. 3, pp. 443-452, 1990.
    • (1990) J. Royal Statist. Soc., B , vol.52 , Issue.3 , pp. 443-452
    • Green, P.J.1
  • 16
    • 0010293907 scopus 로고
    • A statistical model for Positron Emission Tomography (with discussion)
    • Y. Vardi, L. A. Shepp, and L. Kaufman, “A statistical model for Positron Emission Tomography (with discussion),” J. Amer. Statist. Soc., vol. 80, pp. 8-20, 1985.
    • (1985) J. Amer. Statist. Soc. , vol.80 , pp. 8-20
    • Vardi, Y.1    Shepp, L.A.2    Kaufman, L.3
  • 18
    • 0000203955 scopus 로고
    • Accelerated EM reconstruction using ordered subsets
    • (abs)
    • H. M. Hudson, B. F. Hutton, and R. Larkin, “Accelerated EM reconstruction using ordered subsets,” J. Nucl. Med., vol. 33, (abs), p. 960, 1992.
    • (1992) J. Nucl. Med. , vol.33 , pp. 960
    • Hudson, H.M.1    Hutton, B.F.2    Larkin, R.3
  • 19
    • 0028231617 scopus 로고
    • Use of 3-D reconstruction to correct for patient motion in SPECT
    • R. R. Fulton, B. F. Hutton, M. Braun, B. Ardekani, and R. S. Larkin, “Use of 3-D reconstruction to correct for patient motion in SPECT,” Phys. Med. Biol., vol. 39, no. 3, pp. 563-574, 1994.
    • (1994) Phys. Med. Biol. , vol.39 , Issue.3 , pp. 563-574
    • Fulton, R.R.1    Hutton, B.F.2    Braun, M.3    Ardekani, B.4    Larkin, R.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.