메뉴 건너뛰기




Volumn 35, Issue 1, 1988, Pages 625-628

Weighted backprojection implemented with a non-uniform attenuation map for improved spect quantitation

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING - COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING - RECONSTRUCTION; PHOTONS - ATTENUATION;

EID: 0344071788     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.12800     Document Type: Article
Times cited : (18)

References (25)
  • 1
    • 0019031727 scopus 로고
    • SPECT: Single photon emission computed tomography
    • R. J. Jaszczak, R. E. Coleman, and C. B. Lim, “SPECT: Single photon emission computed tomography,” IEEE Trans Nucl Sci, vol. NS-27, pp. 1137–1153, 1980.
    • (1980) IEEE Trans Nucl Sci. , vol.NS-27 , pp. 1137-1153
    • Jaszczak, R.J.1    Coleman, R.E.2    Lim, C.B.3
  • 2
    • 0016068344 scopus 로고
    • Three-dimensional dimensional reconstruction in nuclear medicine emission imaging
    • T. F. Budinger, and G. T. Gullberg, “Three-dimensional dimensional reconstruction in nuclear medicine emission imaging,” IEEE Trans Nucl Sci, vol. NS-21, 21, pp. 2–20, 1974.
    • (1974) IEEE Trans Nucl Sci. , vol.NS-21 , Issue.21 , pp. 2-20
    • Budinger, T.F.1    Gullberg, G.T.2
  • 3
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • L. -T. Chang, “A method for attenuation correction in radionuclide computed tomography,” IEEE Trans Nucl Sci, vol. NS-25, pp. 638–643, 1978.
    • (1978) IEEE Trans Nucl Sci. , vol.NS-25 , pp. 638-643
    • Chang, L.-T.1
  • 4
    • 0022415977 scopus 로고
    • An attenuated projector-backprojector for iterative SPECT reconstruction
    • G. T. Gullberg, R. H. Huesman, J. A. Malko, N. J. Pelc, and T. F. Budinger, “An attenuated projector-backprojector for iterative SPECT reconstruction,” Phys Med Biol, vol. 30, pp. 799–816, 816, 1985.
    • (1985) Phys Med Biol , vol.30 , pp. 799-816
    • Gullberg, G.T.1    Huesman, R.H.2    Malko, J.A.3    Pelc, N.J.4    Budinger, T.F.5
  • 5
    • 0022719492 scopus 로고
    • SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source
    • J. A. Malko, R. L. VanHeertum, G. T. Gullberg, and W. P. Kowalsky, “SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source,” J Nucl Med, vol. 27, pp. 701–705, 1986.
    • (1986) J Nucl Med , vol.27 , pp. 701-705
    • Malko, J.A.1    VanHeertum, R.L.2    Gullberg, G.T.3    Kowalsky, W.P.4
  • 6
    • 0021483748 scopus 로고
    • Attenuation correction for SPECT: An evaluation of hybrid approaches
    • T. L. Faber, M. H. Lewis, J. R. Corbett, and E. M. Stokely, “Attenuation correction for SPECT: An evaluation of hybrid approaches.” IEEE Trans Med Imag, vol 3, pp. 101–107, 1984.
    • (1984) IEEE Trans Med Imag , vol.3 , pp. 101-107
    • Faber, T.L.1    Lewis, M.H.2    Corbett, J.R.3    Stokely, E.M.4
  • 7
    • 0020355936 scopus 로고
    • Attenuation compensation in single-photon emission tomography: A comparative evaluation
    • M. H. Lewis, J. T. Willerson, S. E. Lewis, F. J. Bonte, R. W. Parkey, and E. M. Stokely, “Attenuation compensation in single-photon emission tomography: A comparative evaluation.” J. Nucl Med, vol. 23, pp. 1121–1127, 1982.
    • (1982) J. Nucl Med , vol.23 , pp. 1121-1127
    • Lewis, M.H.1    Willerson, J.T.2    Lewis, S.E.3    Bonte, F.J.4    Parkey, R.W.5    Stokely, E.M.6
  • 8
    • 84939018983 scopus 로고
    • Area weighted approach to attenuation correction in SPECT using arbitrarily shaped nonuniform attenuation maps
    • (abst)
    • R. B. Schwinger, S. L. Cool, and M. A. King, “Area weighted approach to attenuation correction in SPECT using arbitrarily shaped nonuniform attenuation maps.” J Nucl Med, vol. 27, p. 884, 1987 (abst).
    • (1987) J Nucl Med , vol.27 , pp. 884
    • Schwinger, R.B.1    Cool, S.L.2    King, M.A.3
  • 10
    • 84915305535 scopus 로고
    • Iterative attenuation correction in SPECT using attenuation coefficients obtained from transmission measurements
    • (abst)
    • M. Ljungberg, S -E. Strand, B. Jonson, “Iterative attenuation correction in SPECT using attenuation coefficients obtained from transmission measurements.” J Nucl Ned, vol. 27, p. 1004, 1986 (abst).
    • (1986) J Nucl Ned , vol.27 , pp. 1004
    • Ljungberg, M.1    Strand, S.-E.2    Jonson, B.3
  • 11
    • 84939063825 scopus 로고
    • Quantitative single-photon emission tomography
    • (abst)
    • ill] D. Snyder, M. Miller, and C. -J Chen, “Quantitative single-photon emission tomography.”, J Nucl Med, vol. 27, p. 1006, 1986 (abst).
    • (1986) J Nucl Med , vol.27 , pp. 1006
    • Snyder, D.1    Miller, M.2    Chen, C.-J.3
  • 12
    • 0023630988 scopus 로고
    • Non-isotropic isotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques
    • 1987, 1591
    • S. H. Manglos, R. J. Jaszczak, C. E. Floyd, L. J. Hahn, K. L. Greer, and R. E. Coleman, “Non- isotropic isotropic attenuation in SPECT: phantom tests of quantitative effects and compensation techniques”, J Nucl Bed, Vol 28, pp. 1584-1591, 1987. 1591, 1987.
    • (1987) J Nucl Bed , vol.28 , pp. 1584-1591
    • Mangles, S.H.1    Jaszczak, R.J.2    Floyd, C.E.3    Hahn, L.J.4    Greer, K.L.5    Coleman, R.E.6
  • 13
    • 0019394035 scopus 로고
    • The use of filtering methods to compensate for constant attenuation in single-photon emission computed tomography
    • G. T. Gullberg and T. F. Budinger, “The use of filtering methods to compensate for constant attenuation in single-photon emission computed tomography,” IEEE Trans Biomed Eng, vol. BME-28, pp. 142–157, 1981.
    • (1981) IEEE Trans Biomed Eng , vol.BME-28 , pp. 142-157
    • Gullberg, G.T.1    Budinger, T.F.2
  • 14
    • 0020624230 scopus 로고
    • Quantitative image reconstruction with weighted backprojection for single photon emission computed tomography
    • E. Tanaka, “Quantitative image reconstruction with weighted backprojection for single photon emission computed tomography,” J Comp Asst Tom, vol. 7, pp. 692–700, 1983.
    • (1983) J Comp Asst Tom , vol.7 , pp. 692-700
    • Tanaka, E.1
  • 15
    • 0001197863 scopus 로고
    • The Exponential Radon Transform
    • O. Tretiak and C. Metz, “The Exponential Radon Transform,” SIAM J Appl math, vol. 39, pp. 341–354, 354, 1980.
    • (1980) SIAM J Appl math , vol.39 , pp. 341-354
    • Tretiak, O.1    Metz, C.2
  • 16
    • 0021677707 scopus 로고
    • Convolutional image reconstruction for quantitative single photon emission computed tomography
    • E. Tanaka, H. Toyama, H. Murayama, “Convolutional image reconstruction for quantitative single photon emission computed tomography,” Phys Med Biol, vol. 29, pp. 1489–1500, 1984.
    • (1984) Phys Med Biol , vol.29 , pp. 1489-1500
    • Tanaka, E.1    Toyama, H.2    Murayama, H.3
  • 17
    • 0020703599 scopus 로고
    • Inversion for the attenuated Radon transform with constant attenuation
    • K.I. Kim, R.P. Tewarson, Y. Bizais, and R.W. Rowe, “Inversion for the attenuated Radon transform with constant attenuation,” IEEE Trans Nucl Sci, vol. NS-31, pp. 538–542, 1984.
    • (1984) IEEE Trans Nucl Sci. , vol.NS-31 , pp. 538-542
    • Kim, K.I.1    Tewarson, R.P.2    Bizais, Y.3    Rowe, R.W.4
  • 18
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • R. L. Siddon, “Fast calculation of the exact radiological path for a three-dimensional CT array.”, Med Phys, vol. 12, pp. 252–255, 1985.
    • (1985) Med Phys. , vol.12 , pp. 252-255
    • Siddon, R.L.1
  • 19
    • 0343420964 scopus 로고
    • Boundary determination methods for attenuation correction in single photon emission computed tomography
    • ed. New York, NY: Soc Nucl Med
    • G. T. Gullberg, J. A. Malko, and R. L. Eisner, “Boundary determination methods for attenuation correction in single photon emission computed tomography,” in Emission Computed Tomography, Esser P., ed. New York, NY: Soc Nucl Med, 1983, pp. 33–45.
    • (1983) Emission Computed Tomography , pp. 33-45
    • Gullberg, G.T.1    Malko, J.A.2    Eisner, R.L.3    Esser, P.4
  • 21
    • 0016068330 scopus 로고
    • The Fourier reconstruction of a head section
    • L. A. Shepp and B. F. Logan, “The Fourier reconstruction of a head section,” IEEE Trans Nucl Sci, vol. NS-21, pp 21–43, 1974.
    • (1974) IEEE Trans Nucl Sci. , vol.NS-21 , pp. 21-43
    • Shepp, L.A.1    Logan, B.F.2
  • 22
    • 0018608045 scopus 로고
    • Whole-body single-photon emission computed tomography using dual, large-field-of-view view scintillation cameras
    • R. J. Jaszczak, L. -T. Chang, N. A. Stein, and F. E. Moore, “Whole-body single-photon emission computed tomography using dual, large-field-of-view view scintillation cameras,” Phys Med Biol, vol. 24, pp. 1123–1143, 1979.
    • (1979) Phys Med Biol , vol.24 , pp. 1123-1143
    • Jaszczak, R.J.1    Chang, L.-T.2    Stein, N.A.3    Moore, F.E.4
  • 23
    • 0021705394 scopus 로고
    • Tc-99m attenuation coefficients in water-filled phantoms determined with gamma cameras
    • C. C. Harris, K. L. Greer, R. J. Jaszczak, C. E. Floyd, E. C. Fearnow, and R. E. Coleman, “Tc-99m attenuation coefficients in water-filled phantoms determined with gamma cameras,” Med Phys, vol. 11, pp. 681–685, 1984.
    • (1984) Med Phys. , vol.11 , pp. 681-685
    • Harris, C.C.1    Greer, K.L.2    Jaszczak, R.J.3    Floyd, C.E.4    Fearnow, E.C.5    Coleman, R.E.6
  • 24
    • 0021125081 scopus 로고
    • Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation
    • C. E. Floyd, R. J. Jaszczak, C. C. Harris, and R. E. Coleman, “Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation,” Phys Med Biol, vol. 29, pp. 1217–1230, 1984.
    • (1984) Phys Med Biol , vol.29 , pp. 1217-1230
    • Floyd, C.E.1    Jaszczak, R.J.2    Harris, C.C.3    Coleman, R.E.4
  • 25
    • 84939011907 scopus 로고    scopus 로고
    • A quantitative comparison of attenuation-weighted backprojection with multiplicative and iterative post-processing attenuation compensation in SPECT
    • S. H. Manglos, R. J. Jaszczak, C. E. Floyd, L. J. Hahn, K. L. Greer, and R. E. Coleman, “A quantitative comparison of attenuation-weighted backprojection with multiplicative and iterative post-processing attenuation compensation in SPECT,” submitted to IEEE Trans Med Imag
    • submitted to IEEE Trans Med Imag
    • Manglos, S.H.1    Jaszczak, R.J.2    Floyd, C.E.3    Hahn, L.J.4    Greer, K.L.5    Coleman, R.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.