메뉴 건너뛰기




Volumn 6, Issue 1, 1987, Pages 37-51

Implementing and Accelerating the EM Algorithm for Positron Emission Tomography

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING - COMPUTERIZED TOMOGRAPHY; MATHEMATICAL TECHNIQUES - ALGORITHMS;

EID: 0023314408     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.1987.4307796     Document Type: Article
Times cited : (231)

References (20)
  • 1
    • 0002629270 scopus 로고
    • Maximum likelihood from incomplete data via the EM algorithm
    • ser B, vol.
    • A. P. Dempster, N. M. Laird, and D. B. Rubin, “Maximum likelihood from incomplete data via the EM algorithm,” J. Roy. Statist. Soc., ser B, vol. 39, pp. 1–38, 1977.
    • (1977) J. Roy. Statist. Soc. , vol.39 , pp. 1-38
    • Dempster, A.P.1    Laird, N.M.2    Rubin, D.B.3
  • 2
    • 33947133345 scopus 로고
    • A proposal for an extended set of Fortran basic linear algebra subprograms
    • Jan.
    • J. Dongarra, J. Du Croz, S. Hammarling, and R. Hanson, “A proposal for an extended set of Fortran basic linear algebra subprograms,” Signum Newsletter, Jan. 1985.
    • (1985) Signum Newsletter
    • Dongarra, J.1    Du Croz, J.2    Hammarling, S.3    Hanson, R.4
  • 6
    • 84950469208 scopus 로고    scopus 로고
    • Maximum likelihood reconstruction in emission tomography with time-of-flight information: A limited study
    • B. Cooper, R. Laumer, and D. McClure, Eds. New York: Academic, to be published.
    • L. Kaufman, S. Morgenthaler, and Y. Vardi, “Maximum likelihood reconstruction in emission tomography with time-of-flight information: A limited study,” in Automated Image Analysis: Theory and Experiments, B. Cooper, R. Laumer, and D. McClure, Eds. New York: Academic, to be published.
    • Automated Image Analysis: Theory and Experiments
    • Kaufman, L.1    Morgenthaler, S.2    Vardi, Y.3
  • 7
    • 84950428426 scopus 로고
    • Practical considerations
    • comment in Mar.
    • K. J. Kearfott, “Practical considerations,” comment in J. Amer. Statist. Ass., vol. 80, pp. 26–28, Mar. 1985.
    • (1985) J. Amer. Statist. Ass. , vol.80 , pp. 26-28
    • Kearfott, K.J.1
  • 8
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. Carson, “EM reconstruction algorithms for emission and transmission tomography,” J. Comput. Assisted Tomog., vol. 8, pp. 302–316, 1984.
    • (1984) J. Comput. Assisted Tomog. , vol.8 , pp. 302-316
    • Lange, K.1    Carson, R.2
  • 10
    • 84939389455 scopus 로고
    • Accelerated iterative reconstruction for positron emission tomography based on the EM algorithm for maximum likelihood estimation
    • Med. Image Processing Group, Dep. Radiol., Univ. Pennsylvania, Philadelphia, Tech. Rep. MIPG101, June
    • R. Lewitt and G. Muehllehner, “Accelerated iterative reconstruction for positron emission tomography based on the EM algorithm for maximum likelihood estimation,” Med. Image Processing Group, Dep. Radiol., Univ. Pennsylvania, Philadelphia, Tech. Rep. MIPG101, June 1985.
    • (1985)
    • Lewitt, R.1    Muehllehner, G.2
  • 12
    • 33747459777 scopus 로고
    • Reconstruction algorithms for time-of-flight assisted positron-emission tomographs
    • Washington Univ., St. Louis, MO, Dec. supervised by D. L. Snyder.
    • D. G. Politte, “Reconstruction algorithms for time-of-flight assisted positron-emission tomographs,” M.S. thesis, Sever Inst. Technol., Washington Univ., St. Louis, MO, Dec. 1983, supervised by D. L. Snyder.
    • (1983) M.S. thesis, Sever Inst. Technol.
    • Politte, D.G.1
  • 13
    • 0037580182 scopus 로고
    • Computerized tomography: The new medical X-ray technology
    • L. A. Shepp and J. B. Kruskal, “Computerized tomography: The new medical X-ray technology,” Amer. Math. Monthly, vol. 85, pp. 420–439, 1978.
    • (1978) Amer. Math. Monthly , vol.85 , pp. 420-439
    • Shepp, L.A.1    Kruskal, J.B.2
  • 14
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction in positron emission tomography
    • L. A. Shepp and Y. Vardi, “Maximum likelihood reconstruction in positron emission tomography,” IEEE Trans. Med. Imaging, pp. 113–122, 1982.
    • (1982) IEEE Trans. Med. Imaging , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 16
    • 0022142465 scopus 로고
    • The use of sieves to stabilize images produced with the EM algorithm for emission tomography
    • Oct.
    • D. L. Snyder and M. I. Miller, “The use of sieves to stabilize images produced with the EM algorithm for emission tomography,” IEEE Trans. Nucl. Sci., pp. 3864–3872, Oct. 1985.
    • (1985) IEEE Trans. Nucl. Sci. , pp. 3864-3872
    • Snyder, D.L.1    Miller, M.I.2
  • 17
    • 0020761641 scopus 로고
    • Image reconstruction from list-mode mode data in an emission tomography system having time-of-flight measurements
    • D. L. Snyder and D. G. Politte, “Image reconstruction from list-mode mode data in an emission tomography system having time-of-flight measurements,” IEEE Trans. Nucl. Sci., vol. NS-30, pp. 1843–1849, 1983.
    • (1983) IEEE Trans. Nucl. Sci. , vol.NS-30 , pp. 1843-1849
    • Snyder, D.L.1    Politte, D.G.2
  • 19
  • 20
    • 0010293907 scopus 로고
    • A statistical model for positron emission tomography
    • 34–37, Mar.
    • Y. Vardi, L. A. Shepp, L. Kaufman, “A statistical model for positron emission tomography,” J. Amer. Statist. Ass., vol. 80, pp. 8–20, 34–37, Mar. 1985.
    • (1985) J. Amer. Statist. Ass. , vol.80 , pp. 8-20
    • Vardi, Y.1    Shepp, L.A.2    Kaufman, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.