1
-
-
0017928606
-
Single photon emission computed tomography using multi-slice fan beam collimators.
-
Jaszczak RJ, Chang LT, Murphy PH. Single photon emission computed tomography using multi-slice fan beam collimators. IEEE Trans Nucl Sci 1979;NS-26:610-618.
-
(1979)
IEEE Trans Nucl Sci
, vol.NS-26
, pp. 610-618
-
-
Jaszczak, R.J.1
Chang, L.T.2
Murphy, P.H.3
-
2
-
-
0022893713
-
Design and clinical utility of a fan beam collimator for spect imaging of the head
-
Tsui BMW, Gullberg GT, Edgerton ER, Gilland DR, Perry JR, McCartney WH. Design and clinical utility of a fan beam collimator for SPECT imaging of the head. J Nucl Med 1986;27:810-819.
-
(1986)
J Nucl Med
, vol.27
, pp. 810-819
-
-
Tsui, B.1
Gullberg, G.T.2
Edgerton, E.R.3
Gilland, D.R.4
Perry, J.R.5
Mc Cartney, W.H.6
-
3
-
-
0022525205
-
Cone beam collimation for single photon emission computer tomography: Analysis, simulation, and image reconstruction using filtered backprojection
-
Jaszczak RJ, Floyd CEJr, Manglos SH, Greer KL, Coleman RE. Cone beam collimation for single photon emission computer tomography: analysis, simulation, and image reconstruction using filtered backprojection. Med Phys 1986;13:484-489.
-
(1986)
Med Phys
, vol.13
, pp. 484-489
-
-
Jaszczak, R.J.1
Floyd, C.E.2
Manglos, S.H.3
Greer, K.L.4
Coleman, R.E.5
-
4
-
-
0343438814
-
Imaging characteristics of a high resolution cone beam collimator.
-
NS-35
-
Jaszczak RJ, Greer KL, Floyd CE, Manglos SH, Coleman RE. Imaging characteristics of a high resolution cone beam collimator. IEEE Trans Nucl Sci 1988;NS-35:644-648.
-
(1988)
IEEE Trans Nucl Sci
, pp. 644-648
-
-
Jaszczak, R.J.1
Greer, K.L.2
Floyd, C.E.3
Manglos, S.H.4
Coleman, R.E.5
-
5
-
-
0023677772
-
Spect using a specially designed cone beam collimator
-
Jaszczak RJ, Greer KL, Coleman RE. SPECT using a specially designed cone beam collimator. J Nucl Med 1988;29:1398-1405.
-
(1988)
J Nucl Med
, vol.29
, pp. 1398-1405
-
-
Jaszczak, R.J.1
Greer, K.L.2
Coleman, R.E.3
-
7
-
-
7344241431
-
An astigmatic collimator for high sensitivity spect of the brain [abstract]
-
Hawman EG, Hsieh J. An astigmatic collimator for high sensitivity SPECT of the brain [Abstract], J Nucl Med 1986;27:930.
-
(1986)
J Nucl Med
, vol.27
, pp. 930
-
-
Hawman, E.G.1
Hsieh, J.2
-
8
-
-
0026516366
-
Review of converging beam tomography in single photon emission computed tomography
-
Gullberg GT, Zeng GL, Datz FL, Christian PE, Morgan HT. Review of converging beam tomography in single photon emission computed tomography. Phys Med Biol 1992; 37:507-534.
-
(1992)
Phys Med Biol
, vol.37
, pp. 507-534
-
-
Gullberg, G.T.1
Zeng, G.L.2
Datz, F.L.3
Christian, P.E.4
Morgan, H.T.5
-
9
-
-
33745506176
-
Single photon emission computed tomography of the heart using cone beam geometry and noncircular detector rotation. In: Information processing in medical imaging
-
Berkeley, CA, June 19-23
-
Gullberg GT, Zeng GL, Christian PE, Tsui BMW, Morgan HT. Single photon emission computed tomography of the heart using cone beam geometry and noncircular detector rotation. In: Information processing in medical imaging, 11th International Conference. Berkeley, CA, June 19-23, 1989;123-138.
-
(1989)
11Th International Conference.
, pp. 123-138
-
-
Gullberg, G.T.1
Zeng, G.L.2
Christian, P.E.3
Tsui, B.4
Morgan, H.T.5
-
10
-
-
0026375171
-
Cone beam tomography of the heart using single-photon emission-computed tomography
-
Gullberg GT, Christian PE, Zeng GL, Datz FL, Morgan HT. Cone beam tomography of the heart using single-photon emission-computed tomography. Invest Radiol 1991;26:681-688.
-
(1991)
Invest Radiol
, vol.26
, pp. 681-688
-
-
Gullberg, G.T.1
Christian, P.E.2
Zeng, G.L.3
Datz, F.L.4
Morgan, H.T.5
-
12
-
-
0022026907
-
Image reconstruction from cone-beam projections: Necessary and sufficient conditions and reconstruction methods.
-
Smith BD. Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods. IEEE Trans Med Imag 1985;MI-4:14-25.
-
(1985)
IEEE Trans Med Imag
, vol.MI-4
, pp. 14-25
-
-
Smith, B.D.1
-
14
-
-
0025419553
-
A study of reconstruction artifacts in cone beam tomography using filtered backprojection and iterative em algorithms
-
Zeng GL, Gullberg GT. A study of reconstruction artifacts in cone beam tomography using filtered backprojection and iterative EM algorithms. IEEE Trans Nucl Sci 1990;37:759-767.
-
(1990)
IEEE Trans Nucl Sci
, vol.37
, pp. 759-767
-
-
Zeng, G.L.1
Gullberg, G.T.2
-
15
-
-
84939309804
-
Implementation of cone beam tomography on a dual-detector spect system.
-
Abstract
-
Zeng GL, Gullberg GT, Christian PE, Datz FL, Morgan HT. Implementation of cone beam tomography on a dual-detector SPECT system. J Nucl Med 1992;33:892. Abstract.
-
(1992)
J Nucl Med
, vol.33
, pp. 892
-
-
Zeng, G.L.1
Gullberg, G.T.2
Christian, P.E.3
Datz, F.L.4
Morgan, H.T.5
-
16
-
-
0026838538
-
A cone beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography
-
Gullberg GT, Zeng GL. A cone beam filtered backprojection reconstruction algorithm for cardiac single photon emission computed tomography. IEEETrans Med Imag 1992;11:91-101.
-
(1992)
Ieeetrans Med Imag
, vol.11
, pp. 91-101
-
-
Gullberg, G.T.1
Zeng, G.L.2
-
18
-
-
0022470978
-
Roc methodology in radiologic imaging
-
Metz CE. ROC methodology in radiologic imaging. Invest Radiol 1986;21:720-733.
-
(1986)
Invest Radiol
, vol.21
, pp. 720-733
-
-
Metz, C.E.1
-
19
-
-
0024511244
-
Some practical issues of experimental design and data analysis in radiological roc studies
-
Metz CE. Some practical issues of experimental design and data analysis in radiological ROC studies. Invest Radiol 1989;24:234-245.
-
(1989)
Invest Radiol
, vol.24
, pp. 234-245
-
-
Metz, C.E.1
-
20
-
-
85039266459
-
Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. Nuclear medicine/mird
-
Snyder WS, Ford MR, Warner GG, Fisher HL Jr. Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. Nuclear Medicine/MIRD, pamphlet #5, 1969.
-
(1969)
Pamphlet #5
-
-
Snyder, W.S.1
Ford, M.R.2
Warner, G.G.3
Fisher, H.L.4
-
21
-
-
0000658678
-
The design of a mathematical phantom of the upper human torso for use in 3d spect imaging research
-
In: Mikulecky DC, Clarke AM, eds., New York, NY: University Press
-
Terry JA, Tsui BMW, Perry JR, Hendricks JL, Gullberg GT. The design of a mathematical phantom of the upper human torso for use in 3D SPECT imaging research. In: Mikulecky DC, Clarke AM, eds. Biomedical engineering: opening new doors. New York, NY: University Press; 1990:185-190.
-
(1990)
Biomedical Engineering: Opening New Doors
, pp. 185-190
-
-
Terry, J.A.1
Tsui, B.2
Perry, J.R.3
Hendricks, J.L.4
Gullberg, G.T.5
-
23
-
-
0019352338
-
Specific absorbed fractions for photon sources uniformly distributed in the heart chambers and heart wall of a heterogeneous phantom
-
Coffey JL, Cristy M, Warner GG. Specific absorbed fractions for photon sources uniformly distributed in the heart chambers and heart wall of a heterogeneous phantom. J Nucl Med 1981; 22:65-71.
-
(1981)
J Nucl Med
, vol.22
, pp. 65-71
-
-
Coffey, J.L.1
Cristy, M.2
Warner, G.G.3
-
24
-
-
0346025466
-
-
Wright-Patterson Air Force Base, OH: Aerospace Medical Research Laboratory
-
Garrett JW, Kennedy KW. A collation of anthropometry. Wright-Patterson Air Force Base, OH: Aerospace Medical Research Laboratory; 1971.
-
(1971)
A Collation of Anthropometry
-
-
Garrett, J.W.1
Kennedy, K.W.2
-
25
-
-
0016438779
-
Thallium-201 for medical use i
-
Lebowitz E, Greene MW, Fairchild R, Bradley-Moore PR, Atkins HL, Ansari AN, Richards P, Belgrave E. Thallium-201 for medical use I. J Nucl Med 1975;16:151-155.
-
(1975)
J Nucl Med
, vol.16
, pp. 151-155
-
-
Lebowitz, E.1
Greene, M.W.2
Fairchild, R.3
Bradley-Moore, P.R.4
Atkins, H.L.5
Ansari, A.N.6
Richards, P.7
Belgrave, E.8
-
27
-
-
0016442476
-
Thallium- 201 for medical use. Ii. Biologic behavior
-
Bradley-Moore PR, Lebowitz E, Greene MW, Atkins HL, Ansari AN. Thallium- 201 for medical use. II. Biologic behavior. J Nucl Med 1975;16:156-160.
-
(1975)
J Nucl Med
, vol.16
, pp. 156-160
-
-
Bradley-Moore, P.R.1
Lebowitz, E.2
Greene, M.W.3
Atkins, H.L.4
Ansari, A.N.5
-
28
-
-
0019136137
-
The geometric transfer function component for scintillation camera collimators with straight parallel holes
-
Metz CE, Atkins FA, Beck RN. The geometric transfer function component for scintillation camera collimators with straight parallel holes. Phys Med Biol 1980; 25:1059-1070.
-
(1980)
Phys Med Biol
, vol.25
, pp. 1059-1070
-
-
Metz, C.E.1
Atkins, F.A.2
Beck, R.N.3
-
29
-
-
0025070160
-
The geometric transfer function for cone and fan beam collimators
-
Tsui BMW, Gullberg GT. The geometric transfer function for cone and fan beam collimators. Phys Med Biol 1990;35:81-93.
-
(1990)
Phys Med Biol
, vol.35
, pp. 81-93
-
-
Tsui, B.1
Gullberg, G.T.2
-
30
-
-
0001579739
-
Implementation of simultaneous attenuation and detector response correction in spect
-
Tsui BMW, Hu HB, Gilland DR, Gullberg GT. Implementation of simultaneous attenuation and detector response correction in SPECT. IEEE Trans Nucl Sci 1988; 35:778-783.
-
(1988)
IEEE Trans Nucl Sci
, vol.35
, pp. 778-783
-
-
Tsui, B.1
Hu, H.B.2
Gilland, D.R.3
Gullberg, G.T.4
-
31
-
-
0026139673
-
Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction
-
Zeng GL, Gullberg GT, Tsui BMW, Terry JA. Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correction. IEEE Trans Nucl Sci 1991;38:693-702.
-
(1991)
IEEE Trans Nucl Sci
, vol.38
, pp. 693-702
-
-
Zeng, G.L.1
Gullberg, G.T.2
Tsui, B.3
Terry, J.A.4
-
32
-
-
0023932063
-
Determination of the optimum filter function for spect imaging
-
Gilland DR, Tsui BMW, McCartney WH, Perry JR, Berg J. Determination of the optimum filter function for SPECT imaging. J Nucl Med 1988;29:643-650.
-
(1988)
J Nucl Med
, vol.29
, pp. 643-650
-
-
Gilland, D.R.1
Tsui, B.2
Mc Cartney, W.H.3
Perry, J.R.4
Berg, J.5
-
34
-
-
0022683312
-
Reconstruction algorithm for fan beam with a displaced center-of-rotation.
-
Gullberg GT, Crawford CR, Tsui BMW. Reconstruction algorithm for fan beam with a displaced center-of-rotation. IEEE Trans Med Imag 1986; MI-5:23-29.
-
(1986)
IEEE Trans Med Imag
, vol.MI-5
, pp. 23-29
-
-
Gullberg, G.T.1
Crawford, C.R.2
Tsui, B.3
-
35
-
-
0015954210
-
Quantitative effects of stationary linear image processing on noise and resolution of structure in radionuclide images
-
Metz CE, Beck RN. Quantitative effects of stationary linear image processing on noise and resolution of structure in radionuclide images. J Nucl Med 1974;15:164-170.
-
(1974)
J Nucl Med
, vol.15
, pp. 164-170
-
-
Metz, C.E.1
Beck, R.N.2
-
36
-
-
0026564801
-
The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques
-
Rockette HE, Gur D, Metz CE. The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques. Invest Radiol 1992;27:169-172.
-
(1992)
Invest Radiol
, vol.27
, pp. 169-172
-
-
Rockette, H.E.1
Gur, D.2
Metz, C.E.3
-
37
-
-
85039260766
-
Maximum likelihood estimation of parameters of signal detection theoiy and determination of confidence intervals: Rating method data
-
Dorfman DD, Alf E. Maximum likelihood estimation of parameters of signal detection theoiy and determination of confidence intervals: rating method data. J Math Psychol 1969;9:129-139.
-
(1969)
J Math Psychol
, vol.9
, pp. 129-139
-
-
Dorfman, D.D.1
Alf, E.2
-
38
-
-
0001126268
-
Morgan bjt. Some aspects of roc curve-fitting: Normal and logistic models
-
Grey DR, Morgan BJT. Some aspects of ROC curve-fitting: Normal and logistic models. J Math Psychol 1972; 6:128-139.
-
(1972)
J Math Psychol
, vol.6
, pp. 128-139
-
-
Grey, D.R.1
-
41
-
-
0023896566
-
Noise characteristics for cone beam collimators: A comparison with parallel hole collimator
-
Hahn LJ, Jaszczak RJ, Gullberg GT, Floyd CE, Manglos SH, Greer KL, Coleman RE. Noise characteristics for cone beam collimators: a comparison with parallel hole collimator. Phys Med Biol 1988; 33:541-555.
-
(1988)
Phys Med Biol
, vol.33
, pp. 541-555
-
-
Hahn, L.J.1
Jaszczak, R.J.2
Gullberg, G.T.3
Floyd, C.E.4
Manglos, S.H.5
Greer, K.L.6
Coleman, R.E.7
|