Volumn 73, Issue 869, 2000, Pages 459-469

Intensity modulated radiation therapy: A clinical review

Author keywords

[No Author keywords available]

Indexed keywords

CLINICAL TRIAL; HEAD AND NECK CANCER; HUMAN; LOW ENERGY RADIATION; MENINGIOMA; PROSTATE CANCER; RADIATION BEAM; RADIATION DOSE DISTRIBUTION; RADIATION INJURY; REVIEW; STEREOTAXIC SURGERY;

EID: 0034105257     PISSN: 00071285     EISSN: None     Source Type: Journal    
DOI: 10.1259/bjr.73.869.10884741     Document Type: Review
Times cited : (166)

References (82)
  • 2
    • 0027133233 scopus 로고
    • Clinical and technical aspects of conformal therapy
    • Fuks Z, Horwich A. Clinical and technical aspects of conformal therapy. Radiother Oncol 1993;29: 219-20.
    • (1993) Radiother Oncol , vol.29 , pp. 219-220
    • Fuks, Z.1    Horwich, A.2
  • 3
    • 0027463472 scopus 로고
    • Modeling of normal tissue response to radiation: The critical volume model
    • Neimierko A, Goitein M. Modeling of normal tissue response to radiation: the critical volume model. Int J Radiat Oncol Biol Phys 1993;25:135-45.
    • (1993) Int J Radiat Oncol Biol Phys , vol.25 , pp. 135-145
    • Neimierko, A.1    Goitein, M.2
  • 5
    • 0031458180 scopus 로고    scopus 로고
    • Advances in three-dimensional treatment planning and conformal dose delivery
    • Purdy JA. Advances in three-dimensional treatment planning and conformal dose delivery. Semin Oncol 1997;24:655-72.
    • (1997) Semin Oncol , vol.24 , pp. 655-672
    • Purdy, J.A.1
  • 6
    • 0031764408 scopus 로고    scopus 로고
    • Update on the treatment of prostate cancer with external beam irradiation
    • Horwitz EM, Hanlon AL, Hanks GE. Update on the treatment of prostate cancer with external beam irradiation. Prostate 1998;37:195-206.
    • (1998) Prostate , vol.37 , pp. 195-206
    • Horwitz, E.M.1    Hanlon, A.L.2    Hanks, G.E.3
  • 7
    • 0028796044 scopus 로고
    • Radiotherapy of prostate cancer: Established results and new developments
    • Dearnaley DP. Radiotherapy of prostate cancer: established results and new developments. Semin Surg Oncol 1995;11:50-9.
    • (1995) Semin Surg Oncol , vol.11 , pp. 50-59
    • Dearnaley, D.P.1
  • 10
    • 0033026308 scopus 로고    scopus 로고
    • Comparison of radiation side effects of conformal and conventional radiotherapy in prostate cancer: A randomised trial
    • Dearnaley DP, Khoo VS, Norman A, Meyer L, Nahum A, Tait D, et al. Comparison of radiation side effects of conformal and conventional radiotherapy in prostate cancer: a randomised trial. Lancet 1999;352:267-72.
    • (1999) Lancet , vol.352 , pp. 267-272
    • Dearnaley, D.P.1    Khoo, V.S.2    Norman, A.3    Meyer, L.4    Nahum, A.5    Tait, D.6
  • 11
    • 0032054090 scopus 로고    scopus 로고
    • Estimation of the incidence of late bladder and rectum complications after high-dose (70 78 Gy) conformal radiotherapy for prostate cancer using dose-volume histograms
    • Boersma LJ, Van Den Brink M, Bruce AM, Shouman T, Gras L, Te Velde A, et al. Estimation of the incidence of late bladder and rectum complications after high-dose (70 78 Gy) conformal radiotherapy for prostate cancer using dose-volume histograms. Int J Radiat Oncol Biol Phys 1998;41:83-92.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 83-92
    • Boersma, L.J.1    Van Den Brink, M.2    Bruce, A.M.3    Shouman, T.4    Gras, L.5    Te Velde, A.6
  • 12
    • 0029941575 scopus 로고    scopus 로고
    • Lateral rectal wall shielding reduces rectal morbidity following high dose three dimensional conformal radiotherapy for clinically localised prostate cancer: Further evidence for a significant dose effect
    • Lee WR, Hanks GE, Hanlon A, Schultheiss TE, Hunt MA. Lateral rectal wall shielding reduces rectal morbidity following high dose three dimensional conformal radiotherapy for clinically localised prostate cancer: further evidence for a significant dose effect. Int J Radiat Oncol Biol Phys 1996;35:251-7.
    • (1996) Int J Radiat Oncol Biol Phys , vol.35 , pp. 251-257
    • Lee, W.R.1    Hanks, G.E.2    Hanlon, A.3    Schultheiss, T.E.4    Hunt, M.A.5
  • 13
    • 0028882448 scopus 로고
    • Three dimensional conformal radiotherapy for the treatment of prostate cancer: Low risk of chronic rectal morbidity observed in a large series of patients
    • Sandler HM, McLaughlin WP, Ten Haken RK, Addison H, Forman J, Lichter A. Three dimensional conformal radiotherapy for the treatment of prostate cancer: low risk of chronic rectal morbidity observed in a large series of patients. Int J Radiat Oncol Biol Phys 1995;33:797-801.
    • (1995) Int J Radiat Oncol Biol Phys , vol.33 , pp. 797-801
    • Sandler, H.M.1    McLaughlin, W.P.2    Ten Haken, R.K.3    Addison, H.4    Forman, J.5    Lichter, A.6
  • 14
    • 0027501603 scopus 로고
    • Preservation of parotid function after external beam irradiation in head and neck cancer patients: A feasibility study using 3-dimentional treatment planning
    • Hazuka MB, Martel MK, Marsh L, Lichter AS, Wolf GT. Preservation of parotid function after external beam irradiation in head and neck cancer patients: a feasibility study using 3-dimentional treatment planning. Int J Radiat Oncol Biol Phys 1993;27:731-7.
    • (1993) Int J Radiat Oncol Biol Phys , vol.27 , pp. 731-737
    • Hazuka, M.B.1    Martel, M.K.2    Marsh, L.3    Lichter, A.S.4    Wolf, G.T.5
  • 15
    • 0030586031 scopus 로고    scopus 로고
    • Conformal technique dose escalation for prostate cancer: Biochemical evidence of improved cancer control with higher doses in patients with pretreatment prostate specific antigen ≤ 10 ng/ml
    • Hanks GE, Lee WR, Hanlon AL, Hunt M, Kaplan E, Epstein BE, et al. Conformal technique dose escalation for prostate cancer: biochemical evidence of improved cancer control with higher doses in patients with pretreatment prostate specific antigen ≤ 10 ng/ml. Int J Radiat Oncol Biol Phys 1996;35:861-8.
    • (1996) Int J Radiat Oncol Biol Phys , vol.35 , pp. 861-868
    • Hanks, G.E.1    Lee, W.R.2    Hanlon, A.L.3    Hunt, M.4    Kaplan, E.5    Epstein, B.E.6
  • 16
    • 0031779250 scopus 로고    scopus 로고
    • Dose escalation with three dimensional conformal radiation therapy affects the outcome in prostate cancer
    • Zelefsky MJ, Leibel SA, Gaudin PB, et al. Dose escalation with three dimensional conformal radiation therapy affects the outcome in prostate cancer. Int J Radiat Oncol Biol Phys 1998;41:491-500.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 491-500
    • Zelefsky, M.J.1    Leibel, S.A.2    Gaudin, P.B.3
  • 18
    • 0031779815 scopus 로고    scopus 로고
    • Advances in treatment with intensity modulated conformal radiotherapy
    • Webb S. Advances in treatment with intensity modulated conformal radiotherapy. Tumori 1998; 84:112-26.
    • (1998) Tumori , vol.84 , pp. 112-126
    • Webb, S.1
  • 19
    • 0023917549 scopus 로고
    • Optimisation of stationary and moving beam radiation therapy techniques
    • Brahme A. Optimisation of stationary and moving beam radiation therapy techniques. Radiother Oncol 1988;12:129-40.
    • (1988) Radiother Oncol , vol.12 , pp. 129-140
    • Brahme, A.1
  • 20
    • 0030234045 scopus 로고    scopus 로고
    • Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: Static beam-segmentation technique executed with a multileaf collimator
    • De Neve W, De Wagter C, De Jaeger K, Thienpont M, Colle C, Derycke S, et al. Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: static beam-segmentation technique executed with a multileaf collimator. Radiother Oncol 1996; 40:271-9.
    • (1996) Radiother Oncol , vol.40 , pp. 271-279
    • De Neve, W.1    De Wagter, C.2    De Jaeger, K.3    Thienpont, M.4    Colle, C.5    Derycke, S.6
  • 23
    • 0031832642 scopus 로고    scopus 로고
    • Conformal radiotherapy of stage III non-small cell lung cancer: A class solution involving non-coplanar intensity-modulated beams
    • Derycke S, De Gersem WRT, Van Duyse BBR, De Neve WCJ. Conformal radiotherapy of stage III non-small cell lung cancer: a class solution involving non-coplanar intensity-modulated beams. Int J Radiat Oncol Biol Phys 1998;41:771-7.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 771-777
    • Derycke, S.1    De Gersem, W.R.T.2    Van Duyse, B.B.R.3    De Neve, W.C.J.4
  • 25
    • 0030661596 scopus 로고    scopus 로고
    • Planning, delivery, and quality assurance of intensity modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    • Burman C, Chui S, Kutcher G, Leibel S, Zelefsky M, LoSasso T. el al. Planning, delivery, and quality assurance of intensity modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate. Int J Radiat Oncol Biol Phys 1997;39:863-73.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 863-873
    • Burman, C.1    Chui, S.2    Kutcher, G.3    Leibel, S.4    Zelefsky, M.5    LoSasso, T.6
  • 27
    • 0031749966 scopus 로고    scopus 로고
    • Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: Assessment of target coverage and non-involved tissue sparing
    • Eisbruch A, Marsh LH, Martel MK, Ship JA, Ten Haken R, Pu AT, et al. Comprehensive irradiation of head and neck cancer using conformal multisegmental fields: assessment of target coverage and non-involved tissue sparing. Int J Radiat Oncol Biol Phys 1998;41:559-68.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 559-568
    • Eisbruch, A.1    Marsh, L.H.2    Martel, M.K.3    Ship, J.A.4    Ten Haken, R.5    Pu, A.T.6
  • 28
    • 0030095647 scopus 로고    scopus 로고
    • Treatment planning for parotid sparing in the patient requiring bilateral neck irradiation
    • Marsh L, Eisbruch A, Watson B, Martel MK. Treatment planning for parotid sparing in the patient requiring bilateral neck irradiation. Med Dosim 1996;21:7-13.
    • (1996) Med Dosim , vol.21 , pp. 7-13
    • Marsh, L.1    Eisbruch, A.2    Watson, B.3    Martel, M.K.4
  • 29
    • 0031089154 scopus 로고    scopus 로고
    • Parotid sparing study in head and neck cancer patients receiving bilateral radiation therapy: One year results
    • Ship JA, Eisbruch A, D'Hondt E, Jones RE. Parotid sparing study in head and neck cancer patients receiving bilateral radiation therapy: one year results. J Dent Res 1997;76:807-13.
    • (1997) J Dent Res , vol.76 , pp. 807-813
    • Ship, J.A.1    Eisbruch, A.2    D'Hondt, E.3    Jones, R.E.4
  • 30
    • 0032059464 scopus 로고    scopus 로고
    • The influence of pre-radiation salivary flow rates and radiation dose on parotid salivary gland dysfunction in patients receiving radiotherapy for head and neck cancers
    • D'Hondt E, Eisbruch A, Ship JA. The influence of pre-radiation salivary flow rates and radiation dose on parotid salivary gland dysfunction in patients receiving radiotherapy for head and neck cancers. Special Care in Dentistry 1998;18:102-8.
    • (1998) Special Care in Dentistry , vol.18 , pp. 102-108
    • D'Hondt, E.1    Eisbruch, A.2    Ship, J.A.3
  • 31
    • 0032917123 scopus 로고    scopus 로고
    • Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second primary head and neck cancer using a multileaf collimator with dynamic control
    • De Neve W, De Gersem W, Derycke S, De Meerleer G, Moerman M, Bate M-T, et al. Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second primary head and neck cancer using a multileaf collimator with dynamic control. Radiother Oncol 1999;50:301-14.
    • (1999) Radiother Oncol , vol.50 , pp. 301-314
    • De Neve, W.1    De Gersem, W.2    Derycke, S.3    De Meerleer, G.4    Moerman, M.5    Bate, M.-T.6
  • 33
    • 0029850296 scopus 로고    scopus 로고
    • Intensity modulated therapy and inhomogeneous dose to the tumour: A note of caution
    • Goitein M, Niemierko A. Intensity modulated therapy and inhomogeneous dose to the tumour: a note of caution. Int J Radiat Oncol Biol Phys 1996;36:519-22.
    • (1996) Int J Radiat Oncol Biol Phys , vol.36 , pp. 519-522
    • Goitein, M.1    Niemierko, A.2
  • 34
    • 0032945171 scopus 로고    scopus 로고
    • Intensity-modulated radiotherapy: First results with this new technology on neoplasms of the head and neck
    • Kuppersmith RB, Greco SC, Teh BS, Donovan DT, Grant W, Chiu JKC, et al. Intensity-modulated radiotherapy: first results with this new technology on neoplasms of the head and neck. Ear Nose Throat J 1999;78:238-51.
    • (1999) Ear Nose Throat J , vol.78 , pp. 238-251
    • Kuppersmith, R.B.1    Greco, S.C.2    Teh, B.S.3    Donovan, D.T.4    Grant, W.5    Chiu, J.K.C.6
  • 36
    • 10244225226 scopus 로고    scopus 로고
    • Radiotherapy for high grade clinically localised adenocarcinoma of the prostate
    • Roach III M, Meehan S, Kroll S. Radiotherapy for high grade clinically localised adenocarcinoma of the prostate. J Urol 1996;156:1719-23.
    • (1996) J Urol , vol.156 , pp. 1719-1723
    • Roach M. III1    Meehan, S.2    Kroll, S.3
  • 37
    • 0028910506 scopus 로고
    • Advanced prostate cancer: The results of a randomised comparative trial of high dose irradiation boosting with conformal protons compared with conventional irradiation using photons alone
    • Shipley WU, Verhey LJ, Munzenrider JE. Advanced prostate cancer: the results of a randomised comparative trial of high dose irradiation boosting with conformal protons compared with conventional irradiation using photons alone. Int J Radiat Oncol Biol Phys 1995;32:3-12.
    • (1995) Int J Radiat Oncol Biol Phys , vol.32 , pp. 3-12
    • Shipley, W.U.1    Verhey, L.J.2    Munzenrider, J.E.3
  • 38
    • 0030199938 scopus 로고    scopus 로고
    • Conformal radiation treatment of prostate cancer using inversely-planned intensity modulated photon beams produced with dynamic multileaf collimation
    • Ling CC, Burman C, Chui CS, Jackson A, Kutcher GJ, Leibel SA, et al. Conformal radiation treatment of prostate cancer using inversely-planned intensity modulated photon beams produced with dynamic multileaf collimation. Int J Radiat Oncol Biol Phys 1997;35:721-30.
    • (1997) Int J Radiat Oncol Biol Phys , vol.35 , pp. 721-730
    • Ling, C.C.1    Burman, C.2    Chui, C.S.3    Jackson, A.4    Kutcher, G.J.5    Leibel, S.A.6
  • 39
    • 0030661596 scopus 로고    scopus 로고
    • Planning, delivery, and quality assurance of intensity modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    • Burman C, Chui S, Kutcher G, Leibel S, Zelefsky M, LoSasso T, et al. Planning, delivery, and quality assurance of intensity modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate. Int J Radiat Oncol Biol Phys 1997;39:863-73.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 863-873
    • Burman, C.1    Chui, S.2    Kutcher, G.3    Leibel, S.4    Zelefsky, M.5    LoSasso, T.6
  • 41
    • 0030175497 scopus 로고    scopus 로고
    • A comparison of intensity modulated conformal therapy with a conventional external beam stereotactic radiosurgery system for the treatment of single and multiple intra-cranial lesions
    • Woo SY, Grant WH, Bellezza D, Grossman R, Gildenberg P, Carpenter LS, et al. A comparison of intensity modulated conformal therapy with a conventional external beam stereotactic radiosurgery system for the treatment of single and multiple intra-cranial lesions. Int J Radiat Oncol Biol Phys 1996;35:593-7.
    • (1996) Int J Radiat Oncol Biol Phys , vol.35 , pp. 593-597
    • Woo, S.Y.1    Grant, W.H.2    Bellezza, D.3    Grossman, R.4    Gildenberg, P.5    Carpenter, L.S.6
  • 42
    • 0031914314 scopus 로고    scopus 로고
    • Dosimetric comparison of stereotactic radiosurgery to intensity modulated radiotherapy
    • Kramer BA, Wafer DE, Engler MJ, Tsai J, Ling MN. Dosimetric comparison of stereotactic radiosurgery to intensity modulated radiotherapy. Radiat Oncol Invest 1998;6:18-25.
    • (1998) Radiat Oncol Invest , vol.6 , pp. 18-25
    • Kramer, B.A.1    Wafer, D.E.2    Engler, M.J.3    Tsai, J.4    Ling, M.N.5
  • 43
    • 0032170985 scopus 로고    scopus 로고
    • A comparison of three stereotactic radiotherapy techniques; arcs vs noncoplanar fixed fields vs intensity modulation
    • Cardinale RM, Benedict SH, Wu Q, Wicker RD, Gable HE, Mohan R. A comparison of three stereotactic radiotherapy techniques; arcs vs noncoplanar fixed fields vs intensity modulation. Int J Radiat Oncol Biol Phys 1998;42:431-6.
    • (1998) Int J Radiat Oncol Biol Phys , vol.42 , pp. 431-436
    • Cardinale, R.M.1    Benedict, S.H.2    Wu, Q.3    Wicker, R.D.4    Gable, H.E.5    Mohan, R.6
  • 44
    • 0027495078 scopus 로고
    • Stereotactic radiotherapy of irregular targets: A comparison between static conformal beams and non-coplanar arcs
    • Laing RW, Bentley RE, Nahum AE, Warrington AP, Brada M. Stereotactic radiotherapy of irregular targets: a comparison between static conformal beams and non-coplanar arcs. Radiother Oncol 1993;28:241-6.
    • (1993) Radiother Oncol , vol.28 , pp. 241-246
    • Laing, R.W.1    Bentley, R.E.2    Nahum, A.E.3    Warrington, A.P.4    Brada, M.5
  • 45
    • 0030926998 scopus 로고    scopus 로고
    • Breast conserving radiation therapy: Potential of inverse planning with intensity modulation
    • Smitt MC, Li SD, Shostak CA, Chang W, Boyer AL. Breast conserving radiation therapy: potential of inverse planning with intensity modulation. Radiology 1997;203:871-6.
    • (1997) Radiology , vol.203 , pp. 871-876
    • Smitt, M.C.1    Li, S.D.2    Shostak, C.A.3    Chang, W.4    Boyer, A.L.5
  • 46
    • 0033010940 scopus 로고    scopus 로고
    • Optimisation and clinical use of multi-segmented intensity modulated radiation therapy for high dose conformal therapy
    • Fraass BA, Kessler ML, McShan DL, Marsh LH, Watson BA, Dusseau WJ. et al. Optimisation and clinical use of multi-segmented intensity modulated radiation therapy for high dose conformal therapy. Semin Radiat Oncol 1999;9:60-77.
    • (1999) Semin Radiat Oncol , vol.9 , pp. 60-77
    • Fraass, B.A.1    Kessler, M.L.2    McShan, D.L.3    Marsh, L.H.4    Watson, B.A.5    Dusseau, W.J.6
  • 47
    • 0031696075 scopus 로고    scopus 로고
    • Quality assurance of the dose delivered by small radiation segments
    • Hansen VB, Evans PM. Quality assurance of the dose delivered by small radiation segments. Phys Med Biol 1998;43:2665-75.
    • (1998) Phys Med Biol , vol.43 , pp. 2665-2675
    • Hansen, V.B.1    Evans, P.M.2
  • 48
    • 0026661373 scopus 로고
    • The generation of intensity modulated fields for conformal radiotherapy by dynamic collimation
    • Convery DJ, Rosenbloom ME. The generation of intensity modulated fields for conformal radiotherapy by dynamic collimation. Phys Med Biol 1992;37:1359-74.
    • (1992) Phys Med Biol , vol.37 , pp. 1359-1374
    • Convery, D.J.1    Rosenbloom, M.E.2
  • 49
    • 0028077046 scopus 로고
    • Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimation
    • Stein J, Bortfeld T, Dorschel B, Schlegel W. Dynamic X-ray compensation for conformal radiotherapy by means of multi-leaf collimation. Radiother Oncol 1994;32:163-73.
    • (1994) Radiother Oncol , vol.32 , pp. 163-173
    • Stein, J.1    Bortfeld, T.2    Dorschel, B.3    Schlegel, W.4
  • 50
    • 0032972221 scopus 로고    scopus 로고
    • Intensity-modulated radiation therapy with dynamic multileaf collimators
    • Boyer AL, Yu CX. Intensity-modulated radiation therapy with dynamic multileaf collimators. Semin Radiat Oncol 1999;9:48-59.
    • (1999) Semin Radiat Oncol , vol.9 , pp. 48-59
    • Boyer, A.L.1    Yu, C.X.2
  • 51
    • 0028346915 scopus 로고
    • Design characteristics of a multi-leaf collimator
    • Jordan TJ, Williams PC. Design characteristics of a multi-leaf collimator. Phys Med Biol 1994;39:231-51.
    • (1994) Phys Med Biol , vol.39 , pp. 231-251
    • Jordan, T.J.1    Williams, P.C.2
  • 53
    • 0029762999 scopus 로고    scopus 로고
    • Dynamic multileaf collimation without "tongue and groove" underdosage effects
    • Van Santvoort JP, Heijmen BJ. Dynamic multileaf collimation without "tongue and groove" underdosage effects. Phys Med Biol 1996;41:2091-105.
    • (1996) Phys Med Biol , vol.41 , pp. 2091-2105
    • Van Santvoort, J.P.1    Heijmen, B.J.2
  • 54
    • 0030888540 scopus 로고    scopus 로고
    • The effect of stair-step leaf transmission on the "tongue and groove problem" in dynamic radiotherapy with a multileaf collimator
    • Webb S, Bortfeld T, Stein J, Convery D. The effect of stair-step leaf transmission on the "tongue and groove problem" in dynamic radiotherapy with a multileaf collimator. Phys Med Biol 1997;42:595-602.
    • (1997) Phys Med Biol , vol.42 , pp. 595-602
    • Webb, S.1    Bortfeld, T.2    Stein, J.3    Convery, D.4
  • 55
    • 0029113269 scopus 로고
    • Intensity-modulated arc therapy with dynamic multileaf collimation: An alternative to tomotherapy
    • Yu CX. Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy. Phys Med Biol 1995;40:1435-49.
    • (1995) Phys Med Biol , vol.40 , pp. 1435-1449
    • Yu, C.X.1
  • 56
    • 0030457355 scopus 로고    scopus 로고
    • Evaluation of dose calculation algorithm of the peacock system for multileaf intensity modulation collimator
    • Wu A, Johnson M, Chen ASJ, Kalnicki S. Evaluation of dose calculation algorithm of the peacock system for multileaf intensity modulation collimator. Int J Radiat Oncol Biol Phys 1996;36: 1225-31.
    • (1996) Int J Radiat Oncol Biol Phys , vol.36 , pp. 1225-1231
    • Wu, A.1    Johnson, M.2    Chen, A.S.J.3    Kalnicki, S.4
  • 57
    • 0031803615 scopus 로고    scopus 로고
    • A commercial IMRT treatment-planning dose-calculation algorithm
    • Low DA, Mutic S. A commercial IMRT treatment-planning dose-calculation algorithm. Int J Radiat Oncol Biol Phys 1998;41:933-7.
    • (1998) Int J Radiat Oncol Biol Phys , vol.41 , pp. 933-937
    • Low, D.A.1    Mutic, S.2
  • 59
  • 60
    • 0033048691 scopus 로고    scopus 로고
    • Clinical and financial issues for intensity-modulated radiation therapy delivery
    • Grant W, Woo SY. Clinical and financial issues for intensity-modulated radiation therapy delivery. Semin Radiat Oncol 1999;9:99-107.
    • (1999) Semin Radiat Oncol , vol.9 , pp. 99-107
    • Grant, W.1    Woo, S.Y.2
  • 62
    • 0030053667 scopus 로고    scopus 로고
    • The field-matching problem as it applies to the Peacock three-dimensional conformal system for intensity modulation
    • Carol MP, Grant W, Blier AR, Kania AA, Targovnik HS, Butler EB, et al. The field-matching problem as it applies to the Peacock three-dimensional conformal system for intensity modulation. Int J Radiat Oncol Biol Phys 1996;34:183-7.
    • (1996) Int J Radiat Oncol Biol Phys , vol.34 , pp. 183-187
    • Carol, M.P.1    Grant, W.2    Blier, A.R.3    Kania, A.A.4    Targovnik, H.S.5    Butler, E.B.6
  • 66
    • 0039885835 scopus 로고    scopus 로고
    • A new compact treatment unit design combining narrow pencil beam scanning and segmental multileaf collimation
    • Svenssen R, Lind BK, Brahme A. A new compact treatment unit design combining narrow pencil beam scanning and segmental multileaf collimation. Radiother Oncol 1999;51:S21.
    • (1999) Radiother Oncol , vol.51
    • Svenssen, R.1    Lind, B.K.2    Brahme, A.3
  • 67
    • 84956852032 scopus 로고
    • Robotic radiosurgery with beams of adaptable shapes
    • Ayache N, editor. LNCS 905. Berlin, Heidelberg, Germany: Springer-Verlag
    • Schweikard A, Tombropoulos R, Adler JR. Robotic radiosurgery with beams of adaptable shapes. In: Ayache N, editor. Computer vision and robotics in medicine. LNCS 905. Berlin, Heidelberg, Germany: Springer-Verlag, 1995:138-49.
    • (1995) Computer Vision and Robotics in Medicine , pp. 138-149
    • Schweikard, A.1    Tombropoulos, R.2    Adler, J.R.3
  • 68
    • 0032769201 scopus 로고    scopus 로고
    • Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linacs-testing IMRT to the limit?
    • Webb S. Conformal intensity-modulated radiotherapy (IMRT) delivered by robotic linacs-testing IMRT to the limit? Phys Med Biol 1999; 44:1639-54.
    • (1999) Phys Med Biol , vol.44 , pp. 1639-1654
    • Webb, S.1
  • 69
    • 0033048690 scopus 로고    scopus 로고
    • Optimized planning using physical objectives and constraints
    • Bortfeld T. Optimized planning using physical objectives and constraints. Semin Radiat Oncol 1999;9:20-34.
    • (1999) Semin Radiat Oncol , vol.9 , pp. 20-34
    • Bortfeld, T.1
  • 72
    • 0031859145 scopus 로고    scopus 로고
    • Spinal cord dose from standard head and neck irradiation: Implications for three-dimensional treatment planning
    • Martel MK, Eisbruch A, Lawrence TS, Fraas BA, Ten Haken RK, Lichter AS. Spinal cord dose from standard head and neck irradiation: implications for three-dimensional treatment planning. Radiother Oncol 1997;47:185-9.
    • (1997) Radiother Oncol , vol.47 , pp. 185-189
    • Martel, M.K.1    Eisbruch, A.2    Lawrence, T.S.3    Fraas, B.A.4    Ten Haken, R.K.5    Lichter, A.S.6
  • 74
    • 0029704218 scopus 로고    scopus 로고
    • Patient positioning devices: Innovations for set-up precision, speed, and patient comfort
    • Graham MV, Gerber R, Purdy JA. Patient positioning devices: innovations for set-up precision, speed, and patient comfort. Front Radiat Ther Oncol 1996;29:115-22.
    • (1996) Front Radiat Ther Oncol , vol.29 , pp. 115-122
    • Graham, M.V.1    Gerber, R.2    Purdy, J.A.3
  • 76
    • 0030059743 scopus 로고    scopus 로고
    • Intra and inter fraction reproducibility of tangential breast fields: A prospective on-line portal imaging study
    • Fein DA, McGee KP, Schultheiss TE, Fowble BL, Hanks GE. Intra and inter fraction reproducibility of tangential breast fields: a prospective on-line portal imaging study. Int J Radiat Oncol Biol Phys 1996;34:733-40.
    • (1996) Int J Radiat Oncol Biol Phys , vol.34 , pp. 733-740
    • Fein, D.A.1    McGee, K.P.2    Schultheiss, T.E.3    Fowble, B.L.4    Hanks, G.E.5
  • 78
    • 0031732429 scopus 로고    scopus 로고
    • Independent verification using portal imaging of intensity modulated beam delivery by the dynamic MLC technique
    • Partridge M, Evans PM, Mosleh-Shirazi MA, Convery D. Independent verification using portal imaging of intensity modulated beam delivery by the dynamic MLC technique. Med Phys 1998;25: 1872-9.
    • (1998) Med Phys , vol.25 , pp. 1872-1879
    • Partridge, M.1    Evans, P.M.2    Mosleh-Shirazi, M.A.3    Convery, D.4
  • 79
    • 0032520945 scopus 로고    scopus 로고
    • Phantoms for IMRT dose distribution measurement and treatment verification
    • Low DA, Gerber RL, Mutic S, Purdy JA. Phantoms for IMRT dose distribution measurement and treatment verification. Int J Radiat Oncol Biol Phys 1998;40:1231-5.
    • (1998) Int J Radiat Oncol Biol Phys , vol.40 , pp. 1231-1235
    • Low, D.A.1    Gerber, R.L.2    Mutic, S.3    Purdy, J.A.4
  • 81
    • 0030767978 scopus 로고    scopus 로고
    • Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system
    • Ma L, Geis PB, Boyer AL. Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system. Med Phys 1997;24: 1213-20.
    • (1997) Med Phys , vol.24 , pp. 1213-1220
    • Ma, L.1    Geis, P.B.2    Boyer, A.L.3
  • 82
    • 0342904610 scopus 로고    scopus 로고
    • Verification of dynamic multileaf collimation using an electronic portal imaging device
    • James H, Atherton S, Geoffrey B, Michael K, Williams P. Verification of dynamic multileaf collimation using an electronic portal imaging device. Radiother Oncol 1999;51(Suppl. 1):S25.
    • (1999) Radiother Oncol , vol.51 , Issue.SUPPL. 1
    • James, H.1    Atherton, S.2    Geoffrey, B.3    Michael, K.4    Williams, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.