메뉴 건너뛰기




Volumn 50, Issue 3, 1999, Pages 301-314

Clinical delivery of intensity modulated conformal radiotherapy for relapsed or second-primary head and neck cancer using a multileaf collimator with dynamic control

Author keywords

Dosimetry; Intensity modulation; Multileaf collimators; Step and shoot

Indexed keywords

ADULT; ARTICLE; CANCER CONTROL; CANCER RADIOTHERAPY; CANCER RECURRENCE; CANCER STAGING; CASE REPORT; DOSIMETRY; HUMAN; NASOPHARYNX CANCER; OROPHARYNX CANCER; PRIORITY JOURNAL; RADIATION DEPTH DOSE; RADIATION DOSE DISTRIBUTION; TREATMENT PLANNING;

EID: 0032917123     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-8140(99)00019-5     Document Type: Article
Times cited : (90)

References (19)
  • 4
    • 0032178596 scopus 로고    scopus 로고
    • Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry
    • De Deene Y., Van de Walle R., De Wagter C., Achten E. Mathematical analysis and experimental investigation of noise in quantitative magnetic resonance imaging applied in polymer gel dosimetry. Signal Processing. 70:1998;85-101.
    • (1998) Signal Processing , vol.70 , pp. 85-101
    • De Deene, Y.1    Van De Walle, R.2    De Wagter, C.3    Achten, E.4
  • 5
    • 0031762576 scopus 로고    scopus 로고
    • Three-dimensional dosimetry using polymer gel and magnetic resonance imaging (MRI) applied to the verification of conformal radiation therapy in head-and-neck cancer
    • De Deene Y., De Wagter C., Van Duyse B., Derycke S., De Neve W., Achten R. Three-dimensional dosimetry using polymer gel and magnetic resonance imaging (MRI) applied to the verification of conformal radiation therapy in head-and-neck cancer. Radiother. Oncol. 88:1998;283-291.
    • (1998) Radiother. Oncol. , vol.88 , pp. 283-291
    • De Deene, Y.1    De Wagter, C.2    Van Duyse, B.3    Derycke, S.4    De Neve, W.5    Achten, R.6
  • 7
    • 0030234045 scopus 로고    scopus 로고
    • Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: Static beam-segmentation technique executed by a multileaf collimator
    • De Neve W., De Wagter C., De Jaeger K., Thienpont M., Colle C., Derycke S., Schelfhout J. Planning and delivering high doses to targets surrounding the spinal cord at the lower neck and upper mediastinal levels: static beam-segmentation technique executed by a multileaf collimator. Radiother. Oncol. 40:1996;271-279.
    • (1996) Radiother. Oncol. , vol.40 , pp. 271-279
    • De Neve, W.1    De Wagter, C.2    De Jaeger, K.3    Thienpont, M.4    Colle, C.5    Derycke, S.6    Schelfhout, J.7
  • 8
    • 0030833949 scopus 로고    scopus 로고
    • Non' coplanar beam intensity modulation allows large dose-escalation in stagc III lung cancer
    • Derycke S., Van Duyse B., De Wagter C., De Neve W. Non' coplanar beam intensity modulation allows large dose-escalation in stagc III lung cancer. Radiother. Oncol. 45:1997;253-261.
    • (1997) Radiother. Oncol. , vol.45 , pp. 253-261
    • Derycke, S.1    Van Duyse, B.2    De Wagter, C.3    De Neve, W.4
  • 10
  • 11
    • 0015540463 scopus 로고
    • Clinical dose-response curves of human malignant epithelia tumors
    • Fletcher G. Clinical dose-response curves of human malignant epithelia tumors. Br. J. Radiol. 46:1973;1-12.
    • (1973) Br. J. Radiol. , vol.46 , pp. 1-12
    • Fletcher, G.1
  • 13
    • 0024317128 scopus 로고
    • Calculation of complication probability factors for non-uniform normal tissue irradiation the effective volume method
    • Kutcher G.J., Burman C. Calculation of complication probability factors for non-uniform normal tissue irradiation the effective volume method. Int. J. Radiat. Oncol. Biol. Phys. 16:1989;1623-1630.
    • (1989) Int. J. Radiat. Oncol. Biol. Phys. , vol.16 , pp. 1623-1630
    • Kutcher, G.J.1    Burman, C.2
  • 14
    • 0022323855 scopus 로고
    • Complication probabilities as assessed from dose-volume histograms
    • Lyman J.T. Complication probabilities as assessed from dose-volume histograms. Radiat. Res. 104:1985;513-519.
    • (1985) Radiat. Res. , vol.104 , pp. 513-519
    • Lyman, J.T.1
  • 15
    • 0031044393 scopus 로고    scopus 로고
    • Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter
    • Maryanski M.J., Audet C., Gore J.C. Effects of crosslinking and temperature on the dose response of a BANG polymer gel dosimeter. Phys. Med. Biol. 42:1997;303-311.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 303-311
    • Maryanski, M.J.1    Audet, C.2    Gore, J.C.3
  • 18
    • 0030869676 scopus 로고    scopus 로고
    • Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region
    • Verellen D., Linthout N., Berge D., Van Den Bel A., Storme G. Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region. Int. J. Radiat. Oncol. Biol. Phys. 39:1997;99-114.
    • (1997) Int. J. Radiat. Oncol. Biol. Phys. , vol.39 , pp. 99-114
    • Verellen, D.1    Linthout, N.2    Berge, D.3    Van Den Bel, A.4    Storme, G.5
  • 19
    • 0027223126 scopus 로고
    • A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell density
    • Webb S., Nahum A.E. A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell density. Phys. Med. Biol. 38:1993;653-666.
    • (1993) Phys. Med. Biol. , vol.38 , pp. 653-666
    • Webb, S.1    Nahum, A.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.