메뉴 건너뛰기




Volumn 10, Issue 1, 1999, Pages 22-28

Bioanalytic applications of mass spectrometry

Author keywords

[No Author keywords available]

Indexed keywords

GLYCOPROTEIN;

EID: 0032948082     PISSN: 09581669     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0958-1669(99)80005-6     Document Type: Article
Times cited : (43)

References (60)
  • 1
    • 0032528716 scopus 로고    scopus 로고
    • Mass spectrometry
    • This is a biennial review of the current literature of mass spectrometry.
    • Burlingame AL, Boyd RK, Gaskell SJ Mass spectrometry. Anal Chem. 70:1998;647R-716R. This is a biennial review of the current literature of mass spectrometry.
    • (1998) Anal Chem , vol.70
    • Burlingame, A.L.1    Boyd, R.K.2    Gaskell, S.J.3
  • 2
    • 0024438708 scopus 로고
    • Electrospray ionization for the mass spectrometry of large biomolecules
    • Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM Electrospray ionization for the mass spectrometry of large biomolecules. Science. 246:1989;64-71.
    • (1989) Science , vol.246 , pp. 64-71
    • Fenn, J.B.1    Mann, M.2    Meng, C.K.3    Wong, S.F.4    Whitehouse, C.M.5
  • 3
    • 0024289037 scopus 로고
    • Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
    • Karas M, Hillenkamp F Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. Anal Chem. 60:1988;2299-2301.
    • (1988) Anal Chem , vol.60 , pp. 2299-2301
    • Karas, M.1    Hillenkamp, F.2
  • 5
    • 0030658110 scopus 로고    scopus 로고
    • Post-source decay analysis in matrix-assisted laser desorption/ionization mass spectrometry of biomolecules
    • A tutorial on post-source decay MS including experimental details and a guide to interpretation of spectra.
    • Spengler B Post-source decay analysis in matrix-assisted laser desorption/ionization mass spectrometry of biomolecules. J Mass Spectrom. 32:1997;1019-1036. A tutorial on post-source decay MS including experimental details and a guide to interpretation of spectra.
    • (1997) J Mass Spectrom , vol.32 , pp. 1019-1036
    • Spengler, B.1
  • 6
    • 0030822741 scopus 로고    scopus 로고
    • Electrospray: Principles and practice
    • A review with extensive diagrams and examples to introduce ESI MS andprovide many examples of applications.
    • Gaskell SJ Electrospray: principles and practice. J Mass Spectrom. 32:1997;677-688. A review with extensive diagrams and examples to introduce ESI MS andprovide many examples of applications.
    • (1997) J Mass Spectrom , vol.32 , pp. 677-688
    • Gaskell, S.J.1
  • 7
    • 0031623267 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass spectrometry: A primer
    • Marshall AG, Hendrickson CL, Jackson GS Fourier transform ion cyclotron resonance mass spectrometry: a primer. Mass Spectrom Rev. 317:1998;1-35.
    • (1998) Mass Spectrom Rev , vol.317 , pp. 1-35
    • Marshall, A.G.1    Hendrickson, C.L.2    Jackson, G.S.3
  • 8
    • 0031265506 scopus 로고    scopus 로고
    • The use of bioreactive probes in protein characterization
    • A discussion of principles, preparation and illustrations of applications of MALDI probes with surfaces having specific activities for individual biopiolymers or sets of molecules with a common structural feature.
    • Nelson R The use of bioreactive probes in protein characterization. Mass Spectrom Rev. 16:1997;353-376. A discussion of principles, preparation and illustrations of applications of MALDI probes with surfaces having specific activities for individual biopiolymers or sets of molecules with a common structural feature.
    • (1997) Mass Spectrom Rev , vol.16 , pp. 353-376
    • Nelson, R.1
  • 9
    • 53249129192 scopus 로고    scopus 로고
    • High sensitivity peptide mapping by micro-LC with on-line membrane blotting and subsequent detection by scanning-IR-MALDI mass spectrometry
    • Eckerskorn C, Strupat K, Kellermann J, Lottspeich F, Hillenkamp F High sensitivity peptide mapping by micro-LC with on-line membrane blotting and subsequent detection by scanning-IR-MALDI mass spectrometry. J Protein Chem. 16:1997;349-362.
    • (1997) J Protein Chem , vol.16 , pp. 349-362
    • Eckerskorn, C.1    Strupat, K.2    Kellermann, J.3    Lottspeich, F.4    Hillenkamp, F.5
  • 10
    • 0032505091 scopus 로고    scopus 로고
    • Coupling capillary high performance liquid chromatography to matrix-assisted laser desorption/ionization mass spectrometry and N-terminal sequencing of peptides via automated microblotting onto membrane substrates
    • Title adequately covers content of paper. The method advances sensitivity and simplifies sample handling.
    • Stevenson TL, Loo JA, Greis KD Coupling capillary high performance liquid chromatography to matrix-assisted laser desorption/ionization mass spectrometry and N-terminal sequencing of peptides via automated microblotting onto membrane substrates. Anal Biochem. 262:1998;99-109. Title adequately covers content of paper. The method advances sensitivity and simplifies sample handling.
    • (1998) Anal Biochem , vol.262 , pp. 99-109
    • Stevenson, T.L.1    Loo, J.A.2    Greis, K.D.3
  • 11
    • 0031129664 scopus 로고    scopus 로고
    • Protein identification from 2-DE gels by MALDI mass spectrometry
    • Jungblut P, Thiede B Protein identification from 2-DE gels by MALDI mass spectrometry. Mass Spectrom Rev. 16:1997;145-162.
    • (1997) Mass Spectrom Rev , vol.16 , pp. 145-162
    • Jungblut, P.1    Thiede, B.2
  • 12
    • 0031202984 scopus 로고    scopus 로고
    • Analysis of proteins by direct-scanning infrared-MALDI mass spectrometry after 2D-PAGE separation and electroblotting
    • This is the latest contribution from the group that has led in the development of methods for IR-MALDI MS analysis of proteins separated on gels and transferred to membranes.
    • Eckerskorn C, Strupat K, Schleuder S, Hochsttrasser D, Sanche J-C, Lottspeich F, Hillenkamp F Analysis of proteins by direct-scanning infrared-MALDI mass spectrometry after 2D-PAGE separation and electroblotting. Anal Che. 69:1997;2888-2992. This is the latest contribution from the group that has led in the development of methods for IR-MALDI MS analysis of proteins separated on gels and transferred to membranes.
    • (1997) Anal Che , vol.69 , pp. 2888-2992
    • Eckerskorn, C.1    Strupat, K.2    Schleuder, S.3    Hochsttrasser, D.4    Sanche, J.-C.5    Lottspeich, F.6    Hillenkamp, F.7
  • 14
    • 0031148680 scopus 로고    scopus 로고
    • Mass spectrometry of whole proteins eluted from sodium dodecyl sulfate-polyacrylamide gel electrophoresis gels
    • Cohen SL, Chait BT Mass spectrometry of whole proteins eluted from sodium dodecyl sulfate-polyacrylamide gel electrophoresis gels. Anal Biochem. 247:1997;257-267.
    • (1997) Anal Biochem , vol.247 , pp. 257-267
    • Cohen, S.L.1    Chait, B.T.2
  • 15
    • 0032529079 scopus 로고    scopus 로고
    • Concentration and desalting of protein samples for mass spectrometry analysis
    • Winston RL, Fitzgerald MC Concentration and desalting of protein samples for mass spectrometry analysis. Anal Biochem. 262:1998;83-85.
    • (1998) Anal Biochem , vol.262 , pp. 83-85
    • Winston, R.L.1    Fitzgerald, M.C.2
  • 16
    • 0031304362 scopus 로고    scopus 로고
    • Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS
    • Molecular imaging of the spatial distribution of biopolymers in biological tissues is sure to be a growing field; this paper represents a strong early contribution to the area.
    • Caprioli RM, Farmer TB, Gile J Molecular imaging of biological samples: localization of peptides and proteins using MALDI-TOF MS. Anal Chem. 69:1997;4751-4760. Molecular imaging of the spatial distribution of biopolymers in biological tissues is sure to be a growing field; this paper represents a strong early contribution to the area.
    • (1997) Anal Chem , vol.69 , pp. 4751-4760
    • Caprioli, R.M.1    Farmer, T.B.2    Gile, J.3
  • 17
    • 0031832876 scopus 로고    scopus 로고
    • 'Intelligent' fraction collection to improve structural characterization by mass spectrometry
    • Drexler DM, Tiller PR 'Intelligent' fraction collection to improve structural characterization by mass spectrometry. Rapid Commun Mass Spectrom. 12:1998;895-900.
    • (1998) Rapid Commun Mass Spectrom , vol.12 , pp. 895-900
    • Drexler, D.M.1    Tiller, P.R.2
  • 18
    • 0030960366 scopus 로고    scopus 로고
    • Rapid 'de novo' peptide sequencing by a combination of nanoelectrospray, isotopic labeling and a quadrupole/time-of-flight mass spectrometer
    • This paper results from a collaboration between instrumental designers who have the most insight into orthogonal ESI-TOF MS and the group which has been a leader in high sensitivity profiling of peptides and proteins.
    • Shevchenko A, Chernushevich IV, Ens W, Standing KG, Thomson B, Wilm M, Mann M Rapid 'de novo' peptide sequencing by a combination of nanoelectrospray, isotopic labeling and a quadrupole/time-of-flight mass spectrometer. Rapid Commun Mass Spectrom. 11:1997;1015-1024. This paper results from a collaboration between instrumental designers who have the most insight into orthogonal ESI-TOF MS and the group which has been a leader in high sensitivity profiling of peptides and proteins.
    • (1997) Rapid Commun Mass Spectrom , vol.11 , pp. 1015-1024
    • Shevchenko, A.1    Chernushevich, I.V.2    Ens, W.3    Standing, K.G.4    Thomson, B.5    Wilm, M.6    Mann, M.7
  • 19
    • 0031915440 scopus 로고    scopus 로고
    • 18O labeling
    • 18O allows differentiation of amino- and carboxy-terminal fragment ion series. This paper combines this digestion procedure with mass analysis in a quadrupole ion trap.
    • 18O allows differentiation of amino- and carboxy-terminal fragment ion series. This paper combines this digestion procedure with mass analysis in a quadrupole ion trap.
    • (1998) Rapid Commun Mass Spectrom , vol.12 , pp. 209-216
    • Qin, J.1    Herring, C.J.2    Zhang, X.3
  • 20
    • 0032009398 scopus 로고    scopus 로고
    • Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer
    • This contribution combines expertise in sample handling, derivatization and degradation procedures with straightforward MS analysis on a benchtop instrument.
    • Davis MT, Lee T Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometer. J Am Soc Mass Spectrom. 39:1998;194-201. This contribution combines expertise in sample handling, derivatization and degradation procedures with straightforward MS analysis on a benchtop instrument.
    • (1998) J Am Soc Mass Spectrom , vol.39 , pp. 194-201
    • Davis, M.T.1    Lee, T.2
  • 21
    • 0032232005 scopus 로고    scopus 로고
    • Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high sensitivity biological analysis
    • The sensitivity and specificity developed in this methodology should allow in vivo ESI MS measurements and tissue- or cell-specific profiling of neuropeptides.
    • Emmett MR, White FM, Hendrickson CL, Shi SD-H, Marshall AG Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high sensitivity biological analysis. J Am Soc Mass Spectrom. 9:1998;333-340. The sensitivity and specificity developed in this methodology should allow in vivo ESI MS measurements and tissue- or cell-specific profiling of neuropeptides.
    • (1998) J Am Soc Mass Spectrom , vol.9 , pp. 333-340
    • Emmett, M.R.1    White, F.M.2    Hendrickson, C.L.3    Shi, S.-H.4    Marshall, A.G.5
  • 22
    • 0030176044 scopus 로고    scopus 로고
    • Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level
    • Figeys D, van Oostveen I, Ducret A, Aebersold R Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level. Anal Chem. 68:1996;1822-1828.
    • (1996) Anal Chem , vol.68 , pp. 1822-1828
    • Figeys, D.1    Van Oostveen, I.2    Ducret, A.3    Aebersold, R.4
  • 23
    • 0030850138 scopus 로고    scopus 로고
    • Integrated multichannel microchip electrospray ionization mass spectrometry: Analysis of peptides from on-chip tryptic digestion of melittin
    • The procedures described here minimize sample requirement and manipulation and could soon lead to highly automated methods
    • Xue Q, Dunayevskiy YM, Foret F, Karger BL Integrated multichannel microchip electrospray ionization mass spectrometry: analysis of peptides from on-chip tryptic digestion of melittin. Rapid Commun Mass Spectrom. 11:1997;1253-1256. The procedures described here minimize sample requirement and manipulation and could soon lead to highly automated methods.
    • (1997) Rapid Commun Mass Spectrom , vol.11 , pp. 1253-1256
    • Xue, Q.1    Dunayevskiy, Y.M.2    Foret, F.3    Karger, B.L.4
  • 24
    • 0031923064 scopus 로고    scopus 로고
    • Application of microdialysis for on-line coupling of capillary isoelectric focusing with electrospray mass spectrometry on a magnetic sector instrument
    • Lamoree MH, van der Hoeven RAM, Tjaden UR, van der Greef J Application of microdialysis for on-line coupling of capillary isoelectric focusing with electrospray mass spectrometry on a magnetic sector instrument. J Mass Spectrom. 33:1998;453-460.
    • (1998) J Mass Spectrom , vol.33 , pp. 453-460
    • Lamoree, M.H.1    Van Der Hoeven, R.A.M.2    Tjaden, U.R.3    Van Der Greef, J.4
  • 25
    • 0031962102 scopus 로고    scopus 로고
    • Streptavidin in antibody pretargeting. Comparison of a recombinant streptavidin with two streptavidin mutant proteins and two commercially available streptavidin proteins
    • Wilbur DS, Stayton PS, To R, Buhler KR, Klumb LA, Hamlin DK, Stray JE, Vessella RL Streptavidin in antibody pretargeting. Comparison of a recombinant streptavidin with two streptavidin mutant proteins and two commercially available streptavidin proteins. Bioconjug Chem. 9:1998;100-107.
    • (1998) Bioconjug Chem , vol.9 , pp. 100-107
    • Wilbur, D.S.1    Stayton, P.S.2    To, R.3    Buhler, K.R.4    Klumb, L.A.5    Hamlin, D.K.6    Stray, J.E.7    Vessella, R.L.8
  • 26
    • 0001102112 scopus 로고    scopus 로고
    • Tandem FTMS of large biomolecules
    • An introduction to the powerful techniques of FT-ICR MS with numerous examples of applications to protein characterization.
    • Williams ER Tandem FTMS of large biomolecules. Anal Chem. 70:1998;179A-185A. An introduction to the powerful techniques of FT-ICR MS with numerous examples of applications to protein characterization.
    • (1998) Anal Chem , vol.70
    • Williams, E.R.1
  • 27
    • 0031712548 scopus 로고    scopus 로고
    • The use of a stable internal mass standard for accurate mass measurements of oligonucleotide fragment ions using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry with infrared multiphoton dissociation
    • This very sophisticated method capitalizes on the relative stability of protein ions compared to those of oligonucleotides in order to provide exceptionally accurate mass assignments for the oligonucleotide fragments.
    • Hofstadler SA, Griffey RH, Pasa-Tolic L, Smith RD The use of a stable internal mass standard for accurate mass measurements of oligonucleotide fragment ions using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry with infrared multiphoton dissociation. Rapid Commun Mass Spectrom. 12:1998;1400-1404. This very sophisticated method capitalizes on the relative stability of protein ions compared to those of oligonucleotides in order to provide exceptionally accurate mass assignments for the oligonucleotide fragments.
    • (1998) Rapid Commun Mass Spectrom , vol.12 , pp. 1400-1404
    • Hofstadler, S.A.1    Griffey, R.H.2    Pasa-Tolic, L.3    Smith, R.D.4
  • 28
    • 0000944563 scopus 로고    scopus 로고
    • Electron capture dissociation of multiply charged protein cations, a non-ergodic process
    • Zubarev RA, Kelleher NL, McLafferty FW Electron capture dissociation of multiply charged protein cations, a non-ergodic process. J Am Chem Soc. 120:1998;3265-3266.
    • (1998) J Am Chem Soc , vol.120 , pp. 3265-3266
    • Zubarev, R.A.1    Kelleher, N.L.2    McLafferty, F.W.3
  • 30
    • 0031082985 scopus 로고    scopus 로고
    • Ion-molecule reactions as probes of gas-phase structures of peptides and proteins
    • Green MK, Lebrilla CB Ion-molecule reactions as probes of gas-phase structures of peptides and proteins. Mass Spectrom Rev. 16:1997;53-71.
    • (1997) Mass Spectrom Rev , vol.16 , pp. 53-71
    • Green, M.K.1    Lebrilla, C.B.2
  • 31
    • 0032232015 scopus 로고    scopus 로고
    • Isotope depletion of large biomolecules: Implications for molecular mass measurements.
    • Replacement of the broad natural distribution of isotopes into a few peaks yields an increase in signal-to-noise ratio for proteins and reduces the possibility of overlap by signals from multiple components of a complex mixture.
    • Zubarev RA, Demirev PA Isotope depletion of large biomolecules: implications for molecular mass measurements. J Am Soc Mass Spectrom. 9:1998;149-156. Replacement of the broad natural distribution of isotopes into a few peaks yields an increase in signal-to-noise ratio for proteins and reduces the possibility of overlap by signals from multiple components of a complex mixture.
    • (1998) J Am Soc Mass Spectrom , vol.9 , pp. 149-156
    • Zubarev, R.A.1    Demirev, P.A.2
  • 32
    • 0031298696 scopus 로고    scopus 로고
    • Identification of the components of simple protein mixtures by high-accuracy peptide mass mapping and database searching
    • Results from MS experiments may now be easily compared with frequently updated information easily available on the Internet; the approach described here provides rapid identification of many proteins at the level normally recovered from PAGE gels.
    • Jensen ON, Podtelejnikov AN, Mann M Identification of the components of simple protein mixtures by high-accuracy peptide mass mapping and database searching. Anal Chem. 69:1997;4741-4750. Results from MS experiments may now be easily compared with frequently updated information easily available on the Internet; the approach described here provides rapid identification of many proteins at the level normally recovered from PAGE gels.
    • (1997) Anal Chem , vol.69 , pp. 4741-4750
    • Jensen, O.N.1    Podtelejnikov, A.N.2    Mann, M.3
  • 33
    • 53249113519 scopus 로고    scopus 로고
    • The essential role of mass spectrometry in characterizing protein structure: Mapping posttranslational modifications
    • Because the majority of proteins are post-translationally modified, rapid and sensitive methods for handling the assignment of structural modifications are needed; this contribution summarizes the present state of these techniques.
    • Annan RS, Carr SA The essential role of mass spectrometry in characterizing protein structure: mapping posttranslational modifications. J Protein Chem. 16:1997;391-402. Because the majority of proteins are post-translationally modified, rapid and sensitive methods for handling the assignment of structural modifications are needed; this contribution summarizes the present state of these techniques.
    • (1997) J Protein Chem , vol.16 , pp. 391-402
    • Annan, R.S.1    Carr, S.A.2
  • 34
    • 0032009787 scopus 로고    scopus 로고
    • Epitope mapping of monoclonal antibodies by mass spectrometry: Identification of protein antigens in complex biological systems
    • Antigen-antibody interactions are often stable enough to survive ionization and/or proteolysis. New MS methods reviewed here take advantage of the stability of these interactions to localize the active sites.
    • Yu L, Gaskell SJ, Brookman JL Epitope mapping of monoclonal antibodies by mass spectrometry: identification of protein antigens in complex biological systems. J Am Soc Mass Spectrom. 9:1998;208-215. Antigen-antibody interactions are often stable enough to survive ionization and/or proteolysis. New MS methods reviewed here take advantage of the stability of these interactions to localize the active sites.
    • (1998) J Am Soc Mass Spectrom , vol.9 , pp. 208-215
    • Yu, L.1    Gaskell, S.J.2    Brookman, J.L.3
  • 35
    • 0032231990 scopus 로고    scopus 로고
    • Matrix-assisted laser desorption ionization/mass spectrometry mapping of human immunodeficiency virus gp120 epitopes recognized by a limited polyclonal antibody
    • Jeyarajah S, Parker CE, Sumner MT, Tomer KB Matrix-assisted laser desorption ionization/mass spectrometry mapping of human immunodeficiency virus gp120 epitopes recognized by a limited polyclonal antibody. J Am Soc Mass Spectrom. 9:1998;157-165.
    • (1998) J Am Soc Mass Spectrom , vol.9 , pp. 157-165
    • Jeyarajah, S.1    Parker, C.E.2    Sumner, M.T.3    Tomer, K.B.4
  • 37
    • 0002974025 scopus 로고    scopus 로고
    • Mass spectrometry in the combinatorial chemistry revolution
    • Up-to-date review of the ways in which MS can contribute to the rapid structural assignment of products and a guide to the design considerations for such experiments.
    • Loo JA Mass spectrometry in the combinatorial chemistry revolution. Eur Mass Spectrom. 3:1997;93-104. Up-to-date review of the ways in which MS can contribute to the rapid structural assignment of products and a guide to the design considerations for such experiments.
    • (1997) Eur Mass Spectrom , vol.3 , pp. 93-104
    • Loo, J.A.1
  • 38
    • 0031890689 scopus 로고    scopus 로고
    • n analyses of combinatorial libraries using automated matrix-assisted laser desorption/ionization Fourier transform mass spectrometry
    • The first discussion of the practical implementation of FT-ICR MS for combinatorial chemistry product characterization in the setting of a pharmaceutical industry laboratory.
    • n analyses of combinatorial libraries using automated matrix-assisted laser desorption/ionization Fourier transform mass spectrometry. Rapid Commun Mass Spectrom. 12:1998;335-338. The first discussion of the practical implementation of FT-ICR MS for combinatorial chemistry product characterization in the setting of a pharmaceutical industry laboratory.
    • (1998) Rapid Commun Mass Spectrom , vol.12 , pp. 335-338
    • Tutko, D.C.1    Henry, K.D.2    Winger, B.E.3    Stout, H.4    Hemling, M.5
  • 39
    • 0031822744 scopus 로고    scopus 로고
    • A new ultra-high throughput method for characterizing combinatorial libraries incorporating a multiple probe autosampler coupled with flow injection mass spectrometry analysis
    • Wang T, Zeng L, Strader T, Burton L, Kassel DB A new ultra-high throughput method for characterizing combinatorial libraries incorporating a multiple probe autosampler coupled with flow injection mass spectrometry analysis. Rapid Commun Mass Spectrom. 12:1998;1123-1129.
    • (1998) Rapid Commun Mass Spectrom , vol.12 , pp. 1123-1129
    • Wang, T.1    Zeng, L.2    Strader, T.3    Burton, L.4    Kassel, D.B.5
  • 40
    • 0030988935 scopus 로고    scopus 로고
    • Spectrometrically monitored selection experiments: Quantitative laser desorption mass spectrometry of small chemical libraries
    • Berlin K, Jain RK, Tetzlaff C, Steinbeck C, Richert C Spectrometrically monitored selection experiments: quantitative laser desorption mass spectrometry of small chemical libraries. Chem Biol. 4:1997;63-67.
    • (1997) Chem Biol , vol.4 , pp. 63-67
    • Berlin, K.1    Jain, R.K.2    Tetzlaff, C.3    Steinbeck, C.4    Richert, C.5
  • 41
    • 0030621966 scopus 로고    scopus 로고
    • Studying noncovalent protein complexes by electrospray ionization mass spectrometry
    • A current review of the techniques, advantages and possible pitfalls in the study of noncovalent complexes by ESI MS, written by one of the most established practitioners of this approach.
    • Loo J Studying noncovalent protein complexes by electrospray ionization mass spectrometry. Mass Spectrom Rev. 16:1997;1-23. A current review of the techniques, advantages and possible pitfalls in the study of noncovalent complexes by ESI MS, written by one of the most established practitioners of this approach.
    • (1997) Mass Spectrom Rev , vol.16 , pp. 1-23
    • Loo, J.1
  • 42
    • 0001029909 scopus 로고    scopus 로고
    • Matrix-assisted laser desorption-ionization time-of-flight mass spectrometry in the subunit stoichiometry study of high-mass non-covalent complexes
    • A review of MALDI MS analyses of noncovalent complexes, with extensive examples from the authors' laboratory. This paper appears in a special double volume dedicated to MALDI MS that contains a large number of significant contributions by leaders in the field.
    • Moniatte M, Lesieur C, Vécsey-Semjén B, Buckley JT, Pattus F, van der Goot R, Van Dorsselaer FG Matrix-assisted laser desorption-ionization time-of-flight mass spectrometry in the subunit stoichiometry study of high-mass non-covalent complexes. Int J Mass Spectrom Ion Processes. 169:1997;179-199. A review of MALDI MS analyses of noncovalent complexes, with extensive examples from the authors' laboratory. This paper appears in a special double volume dedicated to MALDI MS that contains a large number of significant contributions by leaders in the field.
    • (1997) Int J Mass Spectrom Ion Processes , vol.169 , pp. 179-199
    • Moniatte, M.1    Lesieur, C.2    Vécsey-Semjén, B.3    Buckley, J.T.4    Pattus, F.5    Van Der Goot, R.6    Van Dorsselaer, F.G.7
  • 43
    • 0031463939 scopus 로고    scopus 로고
    • Detection of noncovalent tRNA-aminoacyl-tRNA synthetase complexes by matrix-assisted laser desorption/ionization mass spectrometry
    • Biologically relevant protein-nucleic acid complexes with molecular weights near 100 kDa were observed.
    • Gruic-Sovulj I, Lüdemann H-C, Hillenkamp F, Weygand-Dur evic I, Kucan Z, Peter-Katalinic J Detection of noncovalent tRNA-aminoacyl-tRNA synthetase complexes by matrix-assisted laser desorption/ionization mass spectrometry. J Biol Chem. 272:1997;32084-32091. Biologically relevant protein-nucleic acid complexes with molecular weights near 100 kDa were observed.
    • (1997) J Biol Chem , vol.272 , pp. 32084-32091
    • Gruic-Sovulj, I.1    Lüdemann, H.-C.2    Hillenkamp, F.3    Weygand-Dur, E.I.4    Kucan, Z.5    Peter-Katalinic, J.6
  • 44
    • 0032232021 scopus 로고    scopus 로고
    • Low temperature aqueous electrospray ionization mass spectrometry of noncovalent complexes
    • Many practical details of the ESI MS experiment optimized for observation of noncovalent complexes are discussed.
    • Veenstra TD, Tomlinson AJ, Benson L, Kumar R, Naylor S Low temperature aqueous electrospray ionization mass spectrometry of noncovalent complexes. J Am Soc Mass Spectrom. 9:1998;580-584. Many practical details of the ESI MS experiment optimized for observation of noncovalent complexes are discussed.
    • (1998) J Am Soc Mass Spectrom , vol.9 , pp. 580-584
    • Veenstra, T.D.1    Tomlinson, A.J.2    Benson, L.3    Kumar, R.4    Naylor, S.5
  • 45
    • 0032555738 scopus 로고    scopus 로고
    • Protein subunit interactions and structural integrity of amyloidogenic transthyretins: Evidence from electrospray mass spectrometry
    • This paper correlates X-ray data with observations of interactions among protein subunit components determined by ESI MS, and the influence of amino acid substitutions on the multimer stability.
    • Nettleton EJ, Sunde M, Lai Z, Kelly JW, Dobson CM, Robinson CV Protein subunit interactions and structural integrity of amyloidogenic transthyretins: evidence from electrospray mass spectrometry. J Mol Biol. 281:1998;553-564. This paper correlates X-ray data with observations of interactions among protein subunit components determined by ESI MS, and the influence of amino acid substitutions on the multimer stability.
    • (1998) J Mol Biol , vol.281 , pp. 553-564
    • Nettleton, E.J.1    Sunde, M.2    Lai, Z.3    Kelly, J.W.4    Dobson, C.M.5    Robinson, C.V.6
  • 48
    • 0032528943 scopus 로고    scopus 로고
    • Probing RegA/RNA interactions using electrospray ionization-Fourier transform ion cyclotron resonance-mass spectrometry
    • Liu C, Pasa-Tolic L, Hofstadler SA, Harms AC, Smith RD, Kang CH, Sinha N Probing RegA/RNA interactions using electrospray ionization-Fourier transform ion cyclotron resonance-mass spectrometry. Anal Biochem. 262:1998;67-76.
    • (1998) Anal Biochem , vol.262 , pp. 67-76
    • Liu, C.1    Pasa-Tolic, L.2    Hofstadler, S.A.3    Harms, A.C.4    Smith, R.D.5    Kang, C.H.6    Sinha, N.7
  • 49
    • 0031029388 scopus 로고    scopus 로고
    • Identification of the proteins of the yeast U1 small nuclear ribonucleoprotein complex by mass spectrometry
    • One of the first examples of the assignment of the components of an entire multiprotein complex based on MS combined with database searching.
    • Neubauer G, Gottschalk A, Fabrizio P, Séraphin B, Lührmann R, Mann M Identification of the proteins of the yeast U1 small nuclear ribonucleoprotein complex by mass spectrometry. Proc Natl Acad Sci USA. 94:1997;385-390. One of the first examples of the assignment of the components of an entire multiprotein complex based on MS combined with database searching.
    • (1997) Proc Natl Acad Sci USA , vol.94 , pp. 385-390
    • Neubauer, G.1    Gottschalk, A.2    Fabrizio, P.3    Séraphin, B.4    Lührmann, R.5    Mann, M.6
  • 50
    • 0029927530 scopus 로고    scopus 로고
    • Applications of delayed extraction matrix-assisted laser desorption ionization time-of-flight mass spectrometry to oligonucleotide analysis
    • Juhasz P, Roskey MT, Smirnov IP, Haff LA, Vestal ML, Martin SA Applications of delayed extraction matrix-assisted laser desorption ionization time-of-flight mass spectrometry to oligonucleotide analysis. Anal Chem. 68:1996;941-946.
    • (1996) Anal Chem , vol.68 , pp. 941-946
    • Juhasz, P.1    Roskey, M.T.2    Smirnov, I.P.3    Haff, L.A.4    Vestal, M.L.5    Martin, S.A.6
  • 51
    • 0031302183 scopus 로고    scopus 로고
    • Polyacrylamide gel electrophoresis coupled with matrix-assisted laser desorption/ionization mass spectrometry for tRNA mutant analysis
    • Wei J, Lee CS Polyacrylamide gel electrophoresis coupled with matrix-assisted laser desorption/ionization mass spectrometry for tRNA mutant analysis. Anal Chem. 69:1997;4899-4904.
    • (1997) Anal Chem , vol.69 , pp. 4899-4904
    • Wei, J.1    Lee, C.S.2
  • 52
    • 0032503987 scopus 로고    scopus 로고
    • Infrared MALDI mass spectrometry of large nucleic acids
    • This paper significantly extends the mass range for oligonucleotide analysis.
    • Berkenkamp S, Kirpekar F, Hillenkamp F Infrared MALDI mass spectrometry of large nucleic acids. Science. 281:1998;260-262. This paper significantly extends the mass range for oligonucleotide analysis.
    • (1998) Science , vol.281 , pp. 260-262
    • Berkenkamp, S.1    Kirpekar, F.2    Hillenkamp, F.3
  • 53
    • 0031799347 scopus 로고    scopus 로고
    • A high-throughput microscale method to release N-linked oligosaccharides from glycoproteins for matrix-assisted laser desorption/ionization time-of-flight mass spectrometric analysis
    • The analysis of glycoforms in an industrial setting requires development of methods that are rapid and amenable to automation. This paper demonstrates that techniques similar to those used for protein characterization are feasible for quality-control screening of glycoproteins.
    • Papac DI, Briggs JB, Chin ET, Jones AJS A high-throughput microscale method to release N-linked oligosaccharides from glycoproteins for matrix-assisted laser desorption/ionization time-of-flight mass spectrometric analysis. Glycobiology. 8:1998;445-454. The analysis of glycoforms in an industrial setting requires development of methods that are rapid and amenable to automation. This paper demonstrates that techniques similar to those used for protein characterization are feasible for quality-control screening of glycoproteins.
    • (1998) Glycobiology , vol.8 , pp. 445-454
    • Papac, D.I.1    Briggs, J.B.2    Chin, E.T.3    Jones, A.J.S.4
  • 54
    • 0032505092 scopus 로고    scopus 로고
    • Efficient carbohydrate release, purification and derivatization
    • Charlwood J, Birrell H, Camilleri P Efficient carbohydrate release, purification and derivatization. Anal Biochem. 262:1998;197-200.
    • (1998) Anal Biochem , vol.262 , pp. 197-200
    • Charlwood, J.1    Birrell, H.2    Camilleri, P.3
  • 55
    • 0032005290 scopus 로고    scopus 로고
    • Isomeric differentiation of asparagine-linked oligosaccharides by matrix-assisted laser desorption-ionization postsource decay time-of-flight mass spectrometry
    • Careful determinations of relative abundances of peaks in the PSD mass spectra of native oligosaccharides give reliable indications of glycoform distributions.
    • Rouse JC, Strang AM, Yu W, Vath JE Isomeric differentiation of asparagine-linked oligosaccharides by matrix-assisted laser desorption-ionization postsource decay time-of-flight mass spectrometry. Anal Biochem. 256:1998;33-46. Careful determinations of relative abundances of peaks in the PSD mass spectra of native oligosaccharides give reliable indications of glycoform distributions.
    • (1998) Anal Biochem , vol.256 , pp. 33-46
    • Rouse, J.C.1    Strang, A.M.2    Yu, W.3    Vath, J.E.4
  • 56
    • 0031918414 scopus 로고    scopus 로고
    • Reverse-phase capillary high performance liquid chromatography/high performance electrospray ionization mass spectrometry: An essential tool for the characterization of complex glycoprotein digests
    • The sample size requirement and analysis time for glycoprotein glycosylation site mapping are reduced by utilization of microscale separation methods and ESI Q-TOF mass analysis.
    • Medzihradszky KF, Besman MJ, Burlingame AL Reverse-phase capillary high performance liquid chromatography/high performance electrospray ionization mass spectrometry: an essential tool for the characterization of complex glycoprotein digests. Rapid Commun Mass Spectrom. 12:1998;472-478. The sample size requirement and analysis time for glycoprotein glycosylation site mapping are reduced by utilization of microscale separation methods and ESI Q-TOF mass analysis.
    • (1998) Rapid Commun Mass Spectrom , vol.12 , pp. 472-478
    • Medzihradszky, K.F.1    Besman, M.J.2    Burlingame, A.L.3
  • 57
    • 0030868644 scopus 로고    scopus 로고
    • Characterization of oligosaccharide composition and structure by quadrupole ion trap mass spectrometry
    • Multistage mass analysis of oligosaccharides allows determination of branching patterns; identical substructures give equivalent spectra at any stage of the analysis.
    • Weiskopf AS, Vouros P, Harvey DJ Characterization of oligosaccharide composition and structure by quadrupole ion trap mass spectrometry. Rapid Commun Mass Spectrom. 11:1997;1493-1504. Multistage mass analysis of oligosaccharides allows determination of branching patterns; identical substructures give equivalent spectra at any stage of the analysis.
    • (1997) Rapid Commun Mass Spectrom , vol.11 , pp. 1493-1504
    • Weiskopf, A.S.1    Vouros, P.2    Harvey, D.J.3
  • 58
    • 0003102909 scopus 로고    scopus 로고
    • Direct comparison of matrix-assisted laser desorption/ionization and electrospray ionization in the analysis of gangliosides by Fourier transform mass spectrometry
    • Penn SG, Cancilla MT, Green MK, Lebrilla CB Direct comparison of matrix-assisted laser desorption/ionization and electrospray ionization in the analysis of gangliosides by Fourier transform mass spectrometry. Eur Mass Spectrom. 3:1997;67-79.
    • (1997) Eur Mass Spectrom , vol.3 , pp. 67-79
    • Penn, S.G.1    Cancilla, M.T.2    Green, M.K.3    Lebrilla, C.B.4
  • 59
    • 0032032359 scopus 로고    scopus 로고
    • Electrospray ionization and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry of permethylated oligosaccharides
    • Solouki T, Reinhold BB, Costello CE, O'Malley M, Guan S, Reinhold VN, Marshall AG Electrospray ionization and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry of permethylated oligosaccharides. Anal Chem. 70:1998;857-864.
    • (1998) Anal Chem , vol.70 , pp. 857-864
    • Solouki, T.1    Reinhold, B.B.2    Costello, C.E.3    O'Malley, M.4    Guan, S.5    Reinhold, V.N.6    Marshall, A.G.7
  • 60
    • 0001333930 scopus 로고    scopus 로고
    • High sensitivity mass spectral characterization of glycosphingolipids from bovine erythrocytes, mouse kidney and fetal calf brain
    • MALDI TOF and PSD MS of derivatized glycosphingolipids provide structural information at the low and subpicomole level that enable study of fucosyl transferase pathways in the developing brain. High energy CID on a four-sector instrument provides further information when larger samples are available.
    • Perreault H, Hronowski XL, Koul O, Street J, McCluer RH, Costello CE High sensitivity mass spectral characterization of glycosphingolipids from bovine erythrocytes, mouse kidney and fetal calf brain. Int J Mass Spectrom Ion Processes. 169/170:1997;351-370. MALDI TOF and PSD MS of derivatized glycosphingolipids provide structural information at the low and subpicomole level that enable study of fucosyl transferase pathways in the developing brain. High energy CID on a four-sector instrument provides further information when larger samples are available.
    • (1997) Int J Mass Spectrom Ion Processes , vol.169-170 , pp. 351-370
    • Perreault, H.1    Hronowski, X.L.2    Koul, O.3    Street, J.4    McCluer, R.H.5    Costello, C.E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.