메뉴 건너뛰기




Volumn 119, Issue 8, 1997, Pages 2006-2015

Force titrations and ionization state sensitive imaging of functional groups in aqueous solutions by chemical force microscopy

Author keywords

[No Author keywords available]

Indexed keywords

CARBOXYLIC ACID DERIVATIVE;

EID: 0030889693     PISSN: 00027863     EISSN: None     Source Type: Journal    
DOI: 10.1021/ja963375m     Document Type: Article
Times cited : (426)

References (76)
  • 2
    • 0028328259 scopus 로고
    • (b) Kendall, K. Science 1994, 263, 1720.
    • (1994) Science , vol.263 , pp. 1720
    • Kendall, K.1
  • 8
    • 0028277071 scopus 로고
    • Quate, C. Surf. Sci. 1994, 299/300, 980.
    • (1994) Surf. Sci. , vol.299-300 , pp. 980
    • Quate, C.1
  • 25
    • 0029021712 scopus 로고
    • For a recent review on high resolution AFM in biology see: Shao, Z.; Yang, J. Q. Rev. Biophys. 1995, 28, 195.
    • (1995) Q. Rev. Biophys. , vol.28 , pp. 195
    • Shao, Z.1    Yang, J.2
  • 54
    • 1842353388 scopus 로고    scopus 로고
    • note
    • For our force titration experiments, λ = 3 nm and R > 30 nm.
  • 67
    • 1842302507 scopus 로고    scopus 로고
    • note
    • The lower magnitude of friction forces at constant load observed in ref 49 for higher pH should be predominantly attributed to a decrease in the effective (actual) normal load, because of a buildup of the repulsive double-layer force. Some change in a friction coefficient, however, can also be detected in friction force versus normal force curves presented in that work.
  • 68
    • 0026917533 scopus 로고
    • 13d We attribute it to strong height -friction coupling unavoidable in AFM experiments if the tip is scanned parallel to the cantilever axis of symmetry (see: Radmacher, M.; Tillman, R. W.; Fritz, M.; Gaub, H. E. Science 1992, 257, 1900. Warmack, R. J.; Zheng, X.-Y.; Thundat, T.; Allison, D. P. Rev. Sci. Instrum. 1993, 65, 394). In our experiment the tip was scanned in the perpendicular direction which eliminated the coupling.
    • (1992) Science , vol.257 , pp. 1900
    • Radmacher, M.1    Tillman, R.W.2    Fritz, M.3    Gaub, H.E.4
  • 69
    • 36449005258 scopus 로고
    • 13d We attribute it to strong height - friction coupling unavoidable in AFM experiments if the tip is scanned parallel to the cantilever axis of symmetry (see: Radmacher, M.; Tillman, R. W.; Fritz, M.; Gaub, H. E. Science 1992, 257, 1900. Warmack, R. J.; Zheng, X.-Y.; Thundat, T.; Allison, D. P. Rev. Sci. Instrum. 1993, 65, 394). In our experiment the tip was scanned in the perpendicular direction which eliminated the coupling.
    • (1993) Rev. Sci. Instrum. , vol.65 , pp. 394
    • Warmack, R.J.1    Zheng, X.-Y.2    Thundat, T.3    Allison, D.P.4
  • 70
    • 0026925734 scopus 로고
    • (a) Overney, R. M.; et al. Nature 1992, 395, 133.
    • (1992) Nature , vol.395 , pp. 133
    • Overney, R.M.1
  • 73
    • 1842349387 scopus 로고    scopus 로고
    • note
    • 4 tips are used for imaging of patterned surfaces in fluids, the image contrast is very often unpredictable and even changes during scanning.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.