-
1
-
-
0029893644
-
Accuracy of pedicle screw placement in lumbar vertebrae
-
Castro WH, Halm H, Jerosch J, et al. Accuracy of pedicle screw placement in lumbar vertebrae. Spine (Phila Pa 1976) 1996;21: 1320-4.
-
(1996)
Spine (Phila Pa 1976)
, vol.21
, pp. 1320-1324
-
-
Castro, W.H.1
Halm, H.2
Jerosch, J.3
-
2
-
-
84862612800
-
Pedicle screw insertion: Robotic assistance versus conventional C-arm fluoroscopy
-
Schizas C, Thein E, Kwiatkowski B, et al. Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy. Acta Orthop Belg 2012;78:240-5.
-
(2012)
Acta Orthop Belg
, vol.78
, pp. 240-245
-
-
Schizas, C.1
Thein, E.2
Kwiatkowski, B.3
-
3
-
-
84875941044
-
Comparison of three-dimensional fluoroscopy versus postoperative computed tomography for the assessment of accurate screw placement after instrumented spine surgery
-
Garber ST, Bisson EF, Schmidt MH. Comparison of three-dimensional fluoroscopy versus postoperative computed tomography for the assessment of accurate screw placement after instrumented spine surgery. Global Spine J 2012;2:95-8.
-
(2012)
Global Spine J
, vol.2
, pp. 95-98
-
-
Garber, S.T.1
Bisson, E.F.2
Schmidt, M.H.3
-
4
-
-
33644877691
-
Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: A CT analysis
-
Rampersaud YR, Pik JH, Salonen D, et al. Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine (Phila Pa 1976) 2005;30:E183-90.
-
(2005)
Spine (Phila Pa 1976)
, vol.30
, pp. E183-E190
-
-
Rampersaud, Y.R.1
Pik, J.H.2
Salonen, D.3
-
5
-
-
84868276880
-
Accuracy and safety in pedicle screw placement in the thoracic and lumbar spines: Comparison study between conventional C-arm fluoroscopy and navigation coupled with O-arm(R) guided methods
-
Shin MH, Ryu KS, Park CK. Accuracy and safety in pedicle screw placement in the thoracic and lumbar spines: comparison study between conventional C-arm fluoroscopy and navigation coupled with O-arm(R) guided methods. J Korean Neurosurg Soc 2012; 52:204-9.
-
(2012)
J Korean Neurosurg Soc
, vol.52
, pp. 204-209
-
-
Shin, M.H.1
Ryu, K.S.2
Park, C.K.3
-
6
-
-
85018885809
-
Comparison of minimally invasive spine surgery using intraoperative computed tomography integrated navigation, fluoroscopy and conventional open surgery for lumbar spondylolisthesis: A prospective registry-based cohort study
-
Wu MH, Dubey NK, Li YY, et al. Comparison of minimally invasive spine surgery using intraoperative computed tomography integrated navigation, fluoroscopy and conventional open surgery for lumbar spondylolisthesis: a prospective registry-based cohort study. Spine J 2017;17:1082-90.
-
(2017)
Spine J
, vol.17
, pp. 1082-1090
-
-
Wu, M.H.1
Dubey, N.K.2
Li, Y.Y.3
-
7
-
-
84886099106
-
Intraoperative cone beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): A cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation
-
Tabaraee E, Gibson AG, Karahalios DG, et al. Intraoperative cone beam-computed tomography with navigation (O-ARM) versus conventional fluoroscopy (C-ARM): a cadaveric study comparing accuracy, efficiency, and safety for spinal instrumentation. Spine (Phila Pa 1976) 2013;38:1953-8.
-
(2013)
Spine (Phila Pa 1976)
, vol.38
, pp. 1953-1958
-
-
Tabaraee, E.1
Gibson, A.G.2
Karahalios, D.G.3
-
8
-
-
80052604137
-
Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: Comparison between free-hand and O-arm based navigation techniques
-
Silbermann J, Riese F, Allam Y, et al. Computer tomography assessment of pedicle screw placement in lumbar and sacral spine: comparison between free-hand and O-arm based navigation techniques. Eur Spine J 2011;20:875-81.
-
(2011)
Eur Spine J
, vol.20
, pp. 875-881
-
-
Silbermann, J.1
Riese, F.2
Allam, Y.3
-
9
-
-
84940988844
-
Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: Robot-guided pedicle screw accuracy
-
van Dijk JD, van den Ende RP, Stramigioli S, et al. Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery: robot-guided pedicle screw accuracy. Spine (Phila Pa 1976) 2015;40:E986-91.
-
(2015)
Spine (Phila Pa 1976)
, vol.40
, pp. E986-E991
-
-
Van Dijk, J.D.1
Van Den Ende, R.P.2
Stramigioli, S.3
-
10
-
-
84872085582
-
Spinal robotics: Current applications and future perspectives
-
Roser F, Tatagiba M,Maier G. Spinal robotics: current applications and future perspectives. Neurosurgery 2013;72 (Suppl 1):12-8.
-
(2013)
Neurosurgery
, vol.72
, pp. 12-18
-
-
Roser, F.1
Tatagiba, M.2
Maier, G.3
-
11
-
-
84901771151
-
Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: A matched cohort comparison
-
Schatlo B, Molliqaj G, Cuvinciuc V, et al. Safety and accuracy of robot-assisted versus fluoroscopy-guided pedicle screw insertion for degenerative diseases of the lumbar spine: a matched cohort comparison. J Neurosurg Spine 2014;20:636-43.
-
(2014)
J Neurosurg Spine
, vol.20
, pp. 636-643
-
-
Schatlo, B.1
Molliqaj, G.2
Cuvinciuc, V.3
-
12
-
-
84859955993
-
Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: A prospective randomized comparison to conventional freehand screw implantation
-
Ringel F, Stuer C, Reinke A, et al. Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation. Spine (Phila Pa 1976) 2012;37:E496-501.
-
(2012)
Spine (Phila Pa 1976)
, vol.37
, pp. E496-501
-
-
Ringel, F.1
Stuer, C.2
Reinke, A.3
-
13
-
-
80052594088
-
Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement
-
Kantelhardt SR, Martinez R, Baerwinkel S, et al. Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement. Eur Spine J 2011;20:860-8.
-
(2011)
Eur Spine J
, vol.20
, pp. 860-868
-
-
Kantelhardt, S.R.1
Martinez, R.2
Baerwinkel, S.3
-
14
-
-
84978127700
-
Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: A randomized controlled trial
-
Hyun SJ, Kim KJ, Jahng TA, et al. Minimally invasive robotic versus open fluoroscopic-guided spinal instrumented fusions: a randomized controlled trial. Spine (Phila Pa 1976) 2017;42:353-8.
-
(2017)
Spine (Phila Pa 1976)
, vol.42
, pp. 353-358
-
-
Hyun, S.J.1
Kim, K.J.2
Jahng, T.A.3
-
15
-
-
84893833007
-
Robot-assisted and fluoroscopy-guided pedicle screw placement: A systematic review
-
Marcus HJ, Cundy TP, Nandi D, et al. Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review. Eur Spine J 2014;23:291-7.
-
(2014)
Eur Spine J
, vol.23
, pp. 291-297
-
-
Marcus, H.J.1
Cundy, T.P.2
Nandi, D.3
-
16
-
-
84975466094
-
Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: A systematic review and meta-analysis
-
Liu H, Chen W, Wang Z, et al. Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis. Int J Comput Assist Radiol Surg 2016;11:2273-81.
-
(2016)
Int J Comput Assist Radiol Surg
, vol.11
, pp. 2273-2281
-
-
Liu, H.1
Chen, W.2
Wang, Z.3
-
17
-
-
33846683025
-
Pedicle screw placement accuracy: A meta-analysis
-
Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976) 2007;32:E111-20.
-
(2007)
Spine (Phila Pa 1976)
, vol.32
, pp. E111-E120
-
-
Kosmopoulos, V.1
Schizas, C.2
-
18
-
-
43049106488
-
Free-hand pedicle screw placement during revision spinal surgery: Analysis of 552 screws
-
Kim YW, Lenke LG, Kim YJ, et al. Free-hand pedicle screw placement during revision spinal surgery: analysis of 552 screws. Spine (Phila Pa 1976) 2008;33:1141-8.
-
(2008)
Spine (Phila Pa 1976)
, vol.33
, pp. 1141-1148
-
-
Kim, Y.W.1
Lenke, L.G.2
Kim, Y.J.3
-
19
-
-
84902258273
-
Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: A prospective randomized comparison of navigated versus non-navigated freehand techniques
-
Villard J, Ryang YM, Demetriades AK, et al. Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques. Spine (Phila Pa 1976) 2014;39:1004-9.
-
(2014)
Spine (Phila Pa 1976)
, vol.39
, pp. 1004-1009
-
-
Villard, J.1
Ryang, Y.M.2
Demetriades, A.K.3
-
20
-
-
24944504539
-
Increased cancer risk among surgeons in an orthopaedic hospital
-
Mastrangelo G, Fedeli U, Fadda E, et al. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Lond) 2005;55:498-500.
-
(2005)
Occup Med (Lond)
, vol.55
, pp. 498-500
-
-
Mastrangelo, G.1
Fedeli, U.2
Fadda, E.3
-
22
-
-
0026545845
-
The relationship between back pain and lead apron use in radiologists
-
Moore B, vanSonnenberg E, Casola G, et al. The relationship between back pain and lead apron use in radiologists. AJR Am J Roentgenol 1992;158:191-3.
-
(1992)
AJR Am J Roentgenol
, vol.158
, pp. 191-193
-
-
Moore, B.1
VanSonnenberg, E.2
Casola, G.3
-
23
-
-
84855431289
-
The accuracy of intraoperative O-arm images for the assessment of pedicle screw postion
-
Santos ER, Ledonio CG, Castro CA, et al. The accuracy of intraoperative O-arm images for the assessment of pedicle screw postion. Spine (Phila Pa 1976) 2012;37:E119-25.
-
(2012)
Spine (Phila Pa 1976)
, vol.37
, pp. E119-E125
-
-
Santos, E.R.1
Ledonio, C.G.2
Castro, C.A.3
|