-
1
-
-
0033673342
-
Matched comparison of radical nephrectomy vs nephron-sparing surgery in patients with unilateral renal cell carcinoma and a normal contralateral kidney
-
Lau W.K.O., Blute M.L., Weaver A.L., et al.: 'Matched comparison of radical nephrectomy vs nephron-sparing surgery in patients with unilateral renal cell carcinoma and a normal contralateral kidney', Mayo Clin. Proc, 2000, 75, (12), pp. 1236-1242
-
(2000)
Mayo Clin. Proc
, vol.75
, Issue.12
, pp. 1236-1242
-
-
Lau, W.K.O.1
Blute, M.L.2
Weaver, A.L.3
-
2
-
-
84859834632
-
Long-term survival following partial vs radical nephrectomy among older patients with early-stage kidney cancer
-
Tan H.-J., Norton E.C., Ye Z., et al.: 'Long-term survival following partial vs radical nephrectomy among older patients with early-stage kidney cancer', JAMA, 2012, 307, (15), pp. 1629-1635
-
(2012)
JAMA
, vol.307
, Issue.15
, pp. 1629-1635
-
-
Tan, H.-J.1
Norton, E.C.2
Ye, Z.3
-
3
-
-
68149183580
-
The R.E.N.A.L. Nephrometry score: A comprehensive standardized system for quantitating renal tumor size, location and depth
-
Kutikov A., Uzzo R.G.: 'The R.E.N.A.L. nephrometry score: a comprehensive standardized system for quantitating renal tumor size, location and depth', J. Urol, 2009, 182, (3), pp. 844-853
-
(2009)
J. Urol
, vol.182
, Issue.3
, pp. 844-853
-
-
Kutikov, A.1
Uzzo, R.G.2
-
4
-
-
33744529255
-
Laparoscopic partial nephrectomy for renal masses: Effect of tumor location
-
Venkatesh R., Weld K., Ames C.D., et al.: 'Laparoscopic partial nephrectomy for renal masses: effect of tumor location', Urology, 2006, 67, (6), pp. 1169-1174
-
(2006)
Urology
, vol.67
, Issue.6
, pp. 1169-1174
-
-
Venkatesh, R.1
Weld, K.2
Ames, C.D.3
-
5
-
-
0036136028
-
Does the size of the surgical margin in partial nephrectomy for renal cell cancer really matter?
-
Sutherland S.E., Resnick M.I., Maclennan G.T., et al.: 'Does the size of the surgical margin in partial nephrectomy for renal cell cancer really matter?', J. Urol, 2002, 167, (1), pp. 61-64
-
(2002)
J. Urol
, vol.167
, Issue.1
, pp. 61-64
-
-
Sutherland, S.E.1
Resnick, M.I.2
Maclennan, G.T.3
-
6
-
-
84863393120
-
Renal function after partial nephrectomy: Effect of warm ischemia relative to quantity and quality of preserved kidney
-
Thompson R.H., Lane B.R., Lohse C.M., et al.: 'Renal function after partial nephrectomy: effect of warm ischemia relative to quantity and quality of preserved kidney', Urology, 2012, 79, (2), pp. 356-360
-
(2012)
Urology
, vol.79
, Issue.2
, pp. 356-360
-
-
Thompson, R.H.1
Lane, B.R.2
Lohse, C.M.3
-
7
-
-
84877892259
-
Motion of the kidney between preoperative and intraoperative positioning
-
Schneider C, Nguan C, Longpre M., et al.: 'Motion of the kidney between preoperative and intraoperative positioning', IEEE Trans. Biomed. Eng., 2013, 60, (6), pp. 1619-1627
-
(2013)
IEEE Trans. Biomed. Eng.
, vol.60
, Issue.6
, pp. 1619-1627
-
-
Schneider, C.1
Nguan, C.2
Longpre, M.3
-
8
-
-
84895067861
-
Augmented reality partial nephrectomy: Examining the current status and future perspectives
-
Hughes-Hallett A., Mayer E.K., Marcus H.J., et al.: 'Augmented reality partial nephrectomy: examining the current status and future perspectives', Urology, 2014, 83, (2), pp. 266-273
-
(2014)
Urology
, vol.83
, Issue.2
, pp. 266-273
-
-
Hughes-Hallett, A.1
Mayer, E.K.2
Marcus, H.J.3
-
9
-
-
42249110884
-
Imaging-assisted endoscopic surgery: Cleveland clinic experience
-
Ukimura O., Gill I.S.: 'Imaging-assisted endoscopic surgery: Cleveland clinic experience', J. Endourol., 2008, 22, (4), pp. 803-810
-
(2008)
J. Endourol.
, vol.22
, Issue.4
, pp. 803-810
-
-
Ukimura, O.1
Gill, I.S.2
-
10
-
-
67649450461
-
Augmented reality: A new tool to improve surgical accuracy during laparoscopic partial nephrectomy? Preliminary in vitro and in vivo results
-
Teber D., Guven S., Simpfendörfer T., et al.: 'Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy? preliminary in vitro and in vivo results', Eur. Urol, 2009, 56, (2), pp. 332-338
-
(2009)
Eur. Urol
, vol.56
, Issue.2
, pp. 332-338
-
-
Teber, D.1
Guven, S.2
Simpfendörfer, T.3
-
11
-
-
84990862430
-
Intraoperative computed tomography imaging for navigated laparoscopic renal surgery: First clinical experience
-
Simpfendörfer T., Gasch C, Hatiboglu G, et al.: 'Intraoperative computed tomography imaging for navigated laparoscopic renal surgery: first clinical experience', J. Endourol, 2016, 30, (10), pp. 1105-1111
-
(2016)
J. Endourol
, vol.30
, Issue.10
, pp. 1105-1111
-
-
Simpfendörfer, T.1
Gasch, C.2
Hatiboglu, G.3
-
12
-
-
84968677701
-
Robust augmented reality guidance with fluorescent markers in laparoscopic surgery
-
Wild E., Teber D., Schmid D., et al.: 'Robust augmented reality guidance with fluorescent markers in laparoscopic surgery', Int. J. Comput. Assist. Radiol. Surg., 2016, 11, (6), pp. 899-907
-
(2016)
Int. J. Comput. Assist. Radiol. Surg.
, vol.11
, Issue.6
, pp. 899-907
-
-
Wild, E.1
Teber, D.2
Schmid, D.3
-
13
-
-
63149171096
-
Augmented reality during robot-assisted laparoscopic partial nephrectomy: Toward realtime 3D-CT to stereoscopic video registration
-
Su L.M., Vagvolgyi B.P., Agarwal R., et al.: 'Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward realtime 3D-CT to stereoscopic video registration', Urology, 2009, 73, (4), pp. 896-900
-
(2009)
Urology
, vol.73
, Issue.4
, pp. 896-900
-
-
Su, L.M.1
Vagvolgyi, B.P.2
Agarwal, R.3
-
14
-
-
78349287698
-
Fused video and ultrasound images for minimally invasive partial nephrectomy: A phantom study
-
Cheung C.L., Wedlake C, Moore J., et al.: 'Fused video and ultrasound images for minimally invasive partial nephrectomy: a phantom study', Med. Image Comput. Comput. Assist. Interv., 2010, 6363, pp. 408-415
-
(2010)
Med. Image Comput. Comput. Assist. Interv.
, vol.6363
, pp. 408-415
-
-
Cheung, C.L.1
Wedlake, C.2
Moore, J.3
-
15
-
-
84947033958
-
Robust ultrasound probe tracking: Initial clinical experiences during robot-assisted partial nephrectomy
-
Pratt P., Jaeger A., Hughes-Hallett A., et al.: 'Robust ultrasound probe tracking: initial clinical experiences during robot-assisted partial nephrectomy', Int. J. Comput. Assist. Radiol. Surg., 2015, 10, (12), pp. 1905-1913
-
(2015)
Int. J. Comput. Assist. Radiol. Surg.
, vol.10
, Issue.12
, pp. 1905-1913
-
-
Pratt, P.1
Jaeger, A.2
Hughes-Hallett, A.3
-
16
-
-
85016041621
-
Real-time surgical tool tracking and pose estimation using a hybrid cylindrical marker
-
Zhang L., Ye M., Chan P.L., et al.: 'Real-time surgical tool tracking and pose estimation using a hybrid cylindrical marker', Int. J. Comput. Assist. Radiol. Surg., 2017, 12, (6), pp. 921-930
-
(2017)
Int. J. Comput. Assist. Radiol. Surg.
, vol.12
, Issue.6
, pp. 921-930
-
-
Zhang, L.1
Ye, M.2
Chan, P.L.3
-
18
-
-
85012288975
-
The status of augmented reality in laparoscopic surgery as of 2016
-
Bernhardt S., Nicolau S.A., Soler L., et al.: 'The status of augmented reality in laparoscopic surgery as of 2016', Med. Image Anal, 2017, 37, pp. 66-90
-
(2017)
Med. Image Anal
, vol.37
, pp. 66-90
-
-
Bernhardt, S.1
Nicolau, S.A.2
Soler, L.3
-
19
-
-
84959336397
-
Tracked 'pick-up' ultrasound for robot-assisted minimally invasive surgery
-
Schneider C, Nguan C, Rohling R., et al.: 'Tracked 'pick-up' ultrasound for robot-assisted minimally invasive surgery', IEEE Trans. Biomed. Eng., 2016, 63, (2), pp. 260-268
-
(2016)
IEEE Trans. Biomed. Eng.
, vol.63
, Issue.2
, pp. 260-268
-
-
Schneider, C.1
Nguan, C.2
Rohling, R.3
-
20
-
-
33744930583
-
User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability
-
Yushkevich P.A., Piven J., Hazlett H.C., et al.: 'User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability', Neuroimage, 2006, 31, (3), pp. 1116-1128
-
(2006)
Neuroimage
, vol.31
, Issue.3
, pp. 1116-1128
-
-
Yushkevich, P.A.1
Piven, J.2
Hazlett, H.C.3
-
21
-
-
84892608641
-
Renal ultrasound elastography
-
Grenier N, Gennisson J.L., Cornelis F., et al.: 'Renal ultrasound elastography', Diagn. Interv. Imaging, 2013, 94, (5), pp. 545-550
-
(2013)
Diagn. Interv. Imaging
, vol.94
, Issue.5
, pp. 545-550
-
-
Grenier, N.1
Gennisson, J.L.2
Cornelis, F.3
-
22
-
-
0000879124
-
A flexible new technique for camera calibration
-
Zhang Z.: 'A flexible new technique for camera calibration', IEEE Trans. Pattern Anal. Mach. Intell., 2000, 22, (11), pp. 1330-1334
-
(2000)
IEEE Trans. Pattern Anal. Mach. Intell.
, vol.22
, Issue.11
, pp. 1330-1334
-
-
Zhang, Z.1
-
23
-
-
0026137964
-
Least-squares estimation of transformation parameters between two point patterns
-
Umeyama S.: 'Least-squares estimation of transformation parameters between two point patterns', IEEE Trans. Pattern Anal. Mach. Intell., 1991, 13, (4), pp. 376-380
-
(1991)
IEEE Trans. Pattern Anal. Mach. Intell.
, vol.13
, Issue.4
, pp. 376-380
-
-
Umeyama, S.1
-
24
-
-
84857606482
-
Measuring usability with the system usability scale (SUS)
-
Sauro J.: 'Measuring usability with the system usability scale (SUS)', Meas. Usability, 2011, pp. 1-5
-
(2011)
Meas. Usability
, pp. 1-5
-
-
Sauro, J.1
|