메뉴 건너뛰기




Volumn 56, Issue 4, 2018, Pages 513-515

Visual assessment of sample quality: Quo usque tandem?

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN;

EID: 85037871922     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2017-0867     Document Type: Editorial
Times cited : (25)

References (18)
  • 1
    • 84891139171 scopus 로고    scopus 로고
    • Reference range of hemolysis index in serum and lithium-heparin plasma measured with two analytical platforms in a population of unselected outpatients
    • Lippi G, Giavarina D, Gelati M, Salvagno GL. Reference range of hemolysis index in serum and lithium-heparin plasma measured with two analytical platforms in a population of unselected outpatients. Clin Chim Acta 2014;429:143-6.
    • (2014) Clin Chim Acta , vol.429 , pp. 143-146
    • Lippi, G.1    Giavarina, D.2    Gelati, M.3    Salvagno, G.L.4
  • 2
    • 85025064584 scopus 로고    scopus 로고
    • To report or not to report: A proposal on how to deal with altered test results in hemolytic samples
    • Cadamuro J, Mrazek C, Haschke-Becher E, Sandberg S. To report or not to report: A proposal on how to deal with altered test results in hemolytic samples. Clin Chem Lab Med 2017;55:1109-11.
    • (2017) Clin Chem Lab Med , vol.55 , pp. 1109-1111
    • Cadamuro, J.1    Mrazek, C.2    Haschke-Becher, E.3    Sandberg, S.4
  • 3
    • 85025109921 scopus 로고    scopus 로고
    • Reporting altered test results in hemolyzed samples: Is the cure worse than the disease?
    • Lippi G, Cervellin G, Plebani M. Reporting altered test results in hemolyzed samples: Is the cure worse than the disease? Clin Chem Lab Med 2017;55:1112-4.
    • (2017) Clin Chem Lab Med , vol.55 , pp. 1112-1114
    • Lippi, G.1    Cervellin, G.2    Plebani, M.3
  • 4
    • 80052289159 scopus 로고    scopus 로고
    • Hemolyzed specimens: A major challenge for emergency departments and clinical laboratories
    • Lippi G, Plebani M, Di Somma S, Cervellin G. Hemolyzed specimens: A major challenge for emergency departments and clinical laboratories. Crit Rev Clin Lab Sci 2011;48:143-53.
    • (2011) Crit Rev Clin Lab Sci , vol.48 , pp. 143-153
    • Lippi, G.1    Plebani, M.2    Di Somma, S.3    Cervellin, G.4
  • 5
    • 18744424802 scopus 로고
    • Letter: Reproducibly simulating hemolysis, for evaluating its interference with chemical methods
    • Meites S. Letter: Reproducibly simulating hemolysis, for evaluating its interference with chemical methods. Clin Chem 1973;19:1319.
    • (1973) Clin Chem , vol.19 , pp. 1319
    • Meites, S.1
  • 7
    • 84994530608 scopus 로고    scopus 로고
    • Hemolysis rates in blood samples: Differences between blood collected by clinicians and nurses and the effect of phlebotomy training
    • Cadamuro J, von Meyer A, Wiedemann H, Klaus Felder T, Moser F, Kipman U, et al. Hemolysis rates in blood samples: Differences between blood collected by clinicians and nurses and the effect of phlebotomy training. Clin Chem Lab Med 2016;54:1987-92.
    • (2016) Clin Chem Lab Med , vol.54 , pp. 1987-1992
    • Cadamuro, J.1    Von Meyer, A.2    Wiedemann, H.3    Klaus Felder, T.4    Moser, F.5    Kipman, U.6
  • 8
    • 85043708842 scopus 로고    scopus 로고
    • Making sense of a haemolysis monitoring and reporting system: A nationwide longitudinal multimethod study of 68 Australian laboratory participant organisations
    • Li L, Vecellio E, Gay S, Lake R, Mackay M, Burnett L, et al. Making sense of a haemolysis monitoring and reporting system: A nationwide longitudinal multimethod study of 68 Australian laboratory participant organisations. Clin Chem Lab Med 2018;56:565-73.
    • (2018) Clin Chem Lab Med , vol.56 , pp. 565-573
    • Li, L.1    Vecellio, E.2    Gay, S.3    Lake, R.4    MacKay, M.5    Burnett, L.6
  • 9
    • 85028513463 scopus 로고    scopus 로고
    • Performance specifications for the extra-Analytical phases"
    • Defining a roadmap for harmonizing quality indicators in Laboratory Medicine: A consensus statement on behalf of the IFCC Working Group Laboratory Error and Patient Safety" and EFLM Task and Finish Group
    • Sciacovelli L, Panteghini M, Lippi G, Sumarac Z, Cadamuro J, Galoro CA, et al. Defining a roadmap for harmonizing quality indicators in Laboratory Medicine: A consensus statement on behalf of the IFCC Working Group "Laboratory Error and Patient Safety" and EFLM Task and Finish Group "Performance specifications for the extra-Analytical phases". Clin Chem Lab Med 2017;55:1478-88.
    • (2017) Clin Chem Lab Med , vol.55 , pp. 1478-1488
    • Sciacovelli, L.1    Panteghini, M.2    Lippi, G.3    Sumarac, Z.4    Cadamuro, J.5    Galoro, C.A.6
  • 11
    • 85026313913 scopus 로고    scopus 로고
    • Sensory drive, color, and color vision
    • Price TD. Sensory drive, color, and color vision. Am Nat 2017;190:157-70.
    • (2017) Am Nat , vol.190 , pp. 157-170
    • Price, T.D.1
  • 12
    • 79953732510 scopus 로고    scopus 로고
    • The genetics of normal and defective color vision
    • Neitz J, Neitz M. The genetics of normal and defective color vision. Vision Res 2011;51:633-51.
    • (2011) Vision Res , vol.51 , pp. 633-651
    • Neitz, J.1    Neitz, M.2
  • 13
    • 73349087188 scopus 로고    scopus 로고
    • Comparison of visual vs. Automated detection of lipemic icteric and hemolyzed specimens: Can we rely on a human eye?
    • Simundic AM, Nikolac N, Ivankovic V, Ferenec-Ruzic D, Magdic B, Kvaternik M, et al. Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: Can we rely on a human eye? Clin Chem Lab Med 2009;47:1361-5.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 1361-1365
    • Simundic, A.M.1    Nikolac, N.2    Ivankovic, V.3    Ferenec-Ruzic, D.4    Magdic, B.5    Kvaternik, M.6
  • 14
    • 85007504676 scopus 로고    scopus 로고
    • Current methods of haemolysis detection and reporting as a source of risk to patient safety: A narrative review
    • McCaughey EJ, Vecellio E, Lake R, Li L, Burnett L, Chesher D, et al. Current methods of haemolysis detection and reporting as a source of risk to patient safety: A narrative review. Clin Biochem Rev 2016;37:143-51.
    • (2016) Clin Biochem Rev , vol.37 , pp. 143-151
    • McCaughey, E.J.1    Vecellio, E.2    Lake, R.3    Li, L.4    Burnett, L.5    Chesher, D.6
  • 15
    • 84945457358 scopus 로고    scopus 로고
    • Systematic assessment of the hemolysis index: Pros and cons
    • Lippi G. Systematic assessment of the hemolysis index: Pros and cons. Adv Clin Chem 2015;71:157-70.
    • (2015) Adv Clin Chem , vol.71 , pp. 157-170
    • Lippi, G.1
  • 16
    • 85007579378 scopus 로고    scopus 로고
    • Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st eflm strategic conference
    • Ceriotti F, Fernandez-Calle P, Klee GG, Nordin G, Sandberg S, Streichert T, et al. Criteria for assigning laboratory measurands to models for analytical performance specifications defined in the 1st EFLM Strategic Conference. Clin Chem Lab Med 2017;55:189-94.
    • (2017) Clin Chem Lab Med , vol.55 , pp. 189-194
    • Ceriotti, F.1    Fernandez-Calle, P.2    Klee, G.G.3    Nordin, G.4    Sandberg, S.5    Streichert, T.6
  • 17
    • 84958740355 scopus 로고    scopus 로고
    • Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples
    • Nikolac N, Celap I, Filipi P, Hemar M, Kocijancic M, Miler M, et al. Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples. Clin Chem Lab Med 2016;54:419-25.
    • (2016) Clin Chem Lab Med , vol.54 , pp. 419-425
    • Nikolac, N.1    Celap, I.2    Filipi, P.3    Hemar, M.4    Kocijancic, M.5    Miler, M.6
  • 18
    • 84882861196 scopus 로고    scopus 로고
    • Systematical assessment of serum indices does not impair efficiency of clinical chemistry testing: A multicenter study
    • Lippi G, Avanzini P, Campioli D, Da Rin G, Dipalo M, Aloe R, et al. Systematical assessment of serum indices does not impair efficiency of clinical chemistry testing: A multicenter study. Clin Biochem 2013;46:1281-4.
    • (2013) Clin Biochem , vol.46 , pp. 1281-1284
    • Lippi, G.1    Avanzini, P.2    Campioli, D.3    Da Rin, G.4    Dipalo, M.5    Aloe, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.