메뉴 건너뛰기




Volumn 54, Issue 12, 2016, Pages 1987-1992

Hemolysis rates in blood samples: Differences between blood collected by clinicians and nurses and the effect of phlebotomy training

Author keywords

blood collection; hemolysis; phlebotomy; preanalytics

Indexed keywords

HEMOGLOBIN;

EID: 84994530608     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2016-0175     Document Type: Article
Times cited : (27)

References (43)
  • 1
    • 84979173024 scopus 로고    scopus 로고
    • Internal quality assurance for preanalytical phase
    • Guder WG, Narayanan S, editors. Berlin: De Gruyter
    • Cadamuro J. Internal quality assurance for preanalytical phase. In: Guder WG, Narayanan S, editors. Pre-examination procedures in laboratory diagnostics. Berlin: De Gruyter, 2015:345-51.
    • (2015) Pre-examination Procedures in Laboratory Diagnostics , pp. 345-351
    • Cadamuro, J.1
  • 3
    • 28444436955 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute, Approved Standard-6th edition: Clinical and Laboratory Standards Institute
    • Clinical and Laboratory Standards Institute. Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture. Approved Standard-6th edition: Clinical and Laboratory Standards Institute, 2007.
    • (2007) Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture
  • 5
    • 74549191326 scopus 로고    scopus 로고
    • Evaluation of errors in a clinical laboratory: A one-year experience
    • Goswami B, Singh B, Chawla R, Mallika V. Evaluation of errors in a clinical laboratory: A one-year experience. Clin Chem Lab Med 2010;48:63-6.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 63-66
    • Goswami, B.1    Singh, B.2    Chawla, R.3    Mallika, V.4
  • 6
    • 44949158707 scopus 로고    scopus 로고
    • Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories
    • Lippi G, Blanckaert N, Bonini P, Green S, Kitchen S, Palicka V, et al. Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med 2008;46:764-72.
    • (2008) Clin Chem Lab Med , vol.46 , pp. 764-772
    • Lippi, G.1    Blanckaert, N.2    Bonini, P.3    Green, S.4    Kitchen, S.5    Palicka, V.6
  • 7
    • 84994541705 scopus 로고    scopus 로고
    • Accessed 8 Nov 2015
    • Specimencare. Available at: http://www. specimencare. com. Accessed 8 Nov 2015.
    • Specimencare
  • 9
    • 84958948750 scopus 로고    scopus 로고
    • Reply to: Cadamuro et al. In-vitro hemolysis and its financial impact using different blood collection systems
    • Cadamuro J, Fiedler GM, Mrazek C, Felder TK, Oberkofler H, Kipman U, et al. Reply to: Cadamuro et al. In-vitro hemolysis and its financial impact using different blood collection systems. J Lab Med 2016;40:59-61.
    • (2016) J Lab Med , vol.40 , pp. 59-61
    • Cadamuro, J.1    Fiedler, G.M.2    Mrazek, C.3    Felder, T.K.4    Oberkofler, H.5    Kipman, U.6
  • 10
  • 12
    • 84883026365 scopus 로고    scopus 로고
    • Survey of national guidelines, education and training on phlebotomy in 28 European countries: An original report by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PA)
    • Simundic AM, Cornes M, Grankvist K, Lippi G, Nybo M, Kovalevskaya S, et al. Survey of national guidelines, education and training on phlebotomy in 28 European countries: An original report by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PA). Clin Chem Lab Med 2013;51:1585-93.
    • (2013) Clin Chem Lab Med , vol.51 , pp. 1585-1593
    • Simundic, A.M.1    Cornes, M.2    Grankvist, K.3    Lippi, G.4    Nybo, M.5    Kovalevskaya, S.6
  • 13
    • 84979161102 scopus 로고    scopus 로고
    • Who is doing phlebotomy in Europe
    • Guder WG, Narayanan S, editors. Berlin: De Gruyter
    • Simundic AM. Who is doing phlebotomy in Europe In: Guder WG, Narayanan S, editors. Pre-examination procedures in laboratory diagnostics. Berlin: De Gruyter, 2015:90-4.
    • (2015) Pre-examination Procedures in Laboratory Diagnostics , pp. 90-94
    • Simundic, A.M.1
  • 15
    • 84943527546 scopus 로고    scopus 로고
    • Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals
    • Milutinovic D, Andrijevic I, Licina M, Andrijevic L. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals. Biochem Med (Zagreb) 2015;25:401-9.
    • (2015) Biochem Med (Zagreb) , vol.25 , pp. 401-409
    • Milutinovic, D.1    Andrijevic, I.2    Licina, M.3    Andrijevic, L.4
  • 16
    • 84867830606 scopus 로고    scopus 로고
    • Establishing professional phlebotomist group for quality control of the preanalytic variables of clinical laboratory
    • Wang H, Liu X, Kuang L, Shi H, Jiang Y. Establishing professional phlebotomist group for quality control of the preanalytic variables of clinical laboratory. Clin Chem Lab Med 2012;50:1841-2.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 1841-1842
    • Wang, H.1    Liu, X.2    Kuang, L.3    Shi, H.4    Jiang, Y.5
  • 17
    • 67349257919 scopus 로고    scopus 로고
    • The IFCC Working Group on laboratory errors and patient safety
    • Sciacovelli L, Plebani M. The IFCC Working Group on laboratory errors and patient safety. Clin Chim Acta 2009;404:79-85.
    • (2009) Clin Chim Acta , vol.404 , pp. 79-85
    • Sciacovelli, L.1    Plebani, M.2
  • 18
    • 84994528275 scopus 로고    scopus 로고
    • IFCC Working Group on laboratory errors and patient safety (WG-LEPS). Accessed 19 Nov 2015
    • IFCC Working Group on laboratory errors and patient safety (WG-LEPS). Quality indicators project. Available at: http://www. ifcc-mqi. com. Accessed 19 Nov 2015.
    • Quality Indicators Project
  • 19
    • 70349492209 scopus 로고    scopus 로고
    • Hemolysis index: Quality indicator or criterion for sample rejection
    • Plebani M, Lippi G. Hemolysis index: quality indicator or criterion for sample rejection Clin Chem Lab Med 2009;47: 899-902.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 899-902
    • Plebani, M.1    Lippi, G.2
  • 20
    • 84900335029 scopus 로고    scopus 로고
    • Low volume tubes can be effective to reduce the rate of hemolyzed specimens from the emergency department
    • Giavarina D. Low volume tubes can be effective to reduce the rate of hemolyzed specimens from the emergency department. Clin Biochem 2014;47:688-9.
    • (2014) Clin Biochem , vol.47 , pp. 688-689
    • Giavarina, D.1
  • 21
    • 84977740381 scopus 로고    scopus 로고
    • Influence of the serum collection system on hemolysis
    • Goegebuer T, Debrabandere J. Influence of the serum collection system on hemolysis. Focus Diagnostica 2008;16:22-5.
    • (2008) Focus Diagnostica , vol.16 , pp. 22-25
    • Goegebuer, T.1    Debrabandere, J.2
  • 22
    • 84885066653 scopus 로고    scopus 로고
    • Reduction of gross hemolysis in catheter-drawn blood using Greiner Holdex tube holder
    • Lippi G, Avanzini P, Aloe R, Cervellin G. Reduction of gross hemolysis in catheter-drawn blood using Greiner Holdex tube holder. Biochem Med (Zagreb) 2013;23:303-7.
    • (2013) Biochem Med (Zagreb) , vol.23 , pp. 303-307
    • Lippi, G.1    Avanzini, P.2    Aloe, R.3    Cervellin, G.4
  • 23
    • 84892483891 scopus 로고    scopus 로고
    • Prevalence and cost of hemolyzed samples in a large urban emergency department
    • Lippi G, Bonelli P, Cervellin G. Prevalence and cost of hemolyzed samples in a large urban emergency department. Int J Lab Hematol 2014;36:e24-6.
    • (2014) Int J Lab Hematol , vol.36 , pp. e24-e26
    • Lippi, G.1    Bonelli, P.2    Cervellin, G.3
  • 24
    • 34548331332 scopus 로고    scopus 로고
    • Measurements of free hemoglobin and hemolysis index: EDTA-or lithium-heparinate plasma
    • Unger J, Filippi G, Patsch W. Measurements of free hemoglobin and hemolysis index: EDTA-or lithium-heparinate plasma Clin Chem 2007;53:1717-8.
    • (2007) Clin Chem , vol.53 , pp. 1717-1718
    • Unger, J.1    Filippi, G.2    Patsch, W.3
  • 25
    • 84901587186 scopus 로고    scopus 로고
    • Harmonization of automated hemolysis index assessment and use: Is it possible
    • Dolci A, Panteghini M. Harmonization of automated hemolysis index assessment and use: is it possible Clin Chim Acta 2014;432:38-43.
    • (2014) Clin Chim Acta , vol.432 , pp. 38-43
    • Dolci, A.1    Panteghini, M.2
  • 26
    • 27644507273 scopus 로고
    • Practical uses of serum indexes to reduce errors from lipemia, icterus, and hemolysis
    • Glick M, Ryder K, Vroon D, Masters B, Sonntag O. Practical uses of serum indexes to reduce errors from lipemia, icterus, and hemolysis. Clin Chem 1990;36:1008.
    • (1990) Clin Chem , vol.36 , pp. 1008
    • Glick, M.1    Ryder, K.2    Vroon, D.3    Masters, B.4    Sonntag, O.5
  • 27
    • 84938542371 scopus 로고    scopus 로고
    • Compliance of blood sampling procedures with the CLSI H3-A6 guidelines: An observational study by the EuropeanFederation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE)
    • Simundic AM, Church S, Cornes MP, Grankvist K, Lippi G, Nybo M, et al. Compliance of blood sampling procedures with the CLSI H3-A6 guidelines: An observational study by the EuropeanFederation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE). Clin Chem Lab Med 2015;53:1321-31.
    • (2015) Clin Chem Lab Med , vol.53 , pp. 1321-1331
    • Simundic, A.M.1    Church, S.2    Cornes, M.P.3    Grankvist, K.4    Lippi, G.5    Nybo, M.6
  • 30
    • 0030893027 scopus 로고    scopus 로고
    • Chemistry specimen acceptability: A College of American Pathologists Q-Probes study of 453 laboratories
    • Jones BA, Calam RR, Howanitz PJ. Chemistry specimen acceptability: A College of American Pathologists Q-Probes study of 453 laboratories. Arch Pathol Lab Med 1997;121:19-26.
    • (1997) Arch Pathol Lab Med , vol.121 , pp. 19-26
    • Jones, B.A.1    Calam, R.R.2    Howanitz, P.J.3
  • 31
    • 33645242368 scopus 로고    scopus 로고
    • Laboratory quality improvement by implementation of phlebotomy guidelines
    • author reply
    • Lippi G, Mattiuzzi C, Guidi GC. Laboratory quality improvement by implementation of phlebotomy guidelines. MLO Med Lab Obs 2006;38:6-7; author reply.
    • (2006) MLO Med Lab Obs , vol.38 , pp. 6-7
    • Lippi, G.1    Mattiuzzi, C.2    Guidi, G.C.3
  • 32
    • 84868514714 scopus 로고    scopus 로고
    • Reducing preanalytical laboratory sample errors through educational and technological interventions
    • Lillo R, Salinas M, Lopez-Garrigos M, Naranjo-Santana Y, Gutierrez M, Marin MD, et al. Reducing preanalytical laboratory sample errors through educational and technological interventions. Clin Lab 2012;58:911-7.
    • (2012) Clin Lab , vol.58 , pp. 911-917
    • Lillo, R.1    Salinas, M.2    Lopez-Garrigos, M.3    Naranjo-Santana, Y.4    Gutierrez, M.5    Marin, M.D.6
  • 33
    • 84860658858 scopus 로고    scopus 로고
    • Let the data speak: Decreasing hemolysis rates through education, practice, and disclosure
    • McGrath JK, Rankin P, Schendel M. Let the data speak: decreasing hemolysis rates through education, practice, and disclosure. J Emerg Nurs 2012;38:239-44.
    • (2012) J Emerg Nurs , vol.38 , pp. 239-244
    • McGrath, J.K.1    Rankin, P.2    Schendel, M.3
  • 34
    • 84875454707 scopus 로고    scopus 로고
    • Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention
    • Bolenius K, Soderberg J, Hultdin J, Lindkvist M, Brulin C, Grankvist K. Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention. Clin Chem Lab Med 2013;51:303-10.
    • (2013) Clin Chem Lab Med , vol.51 , pp. 303-310
    • Bolenius, K.1    Soderberg, J.2    Hultdin, J.3    Lindkvist, M.4    Brulin, C.5    Grankvist, K.6
  • 35
    • 0036239525 scopus 로고    scopus 로고
    • Hemolysis in Serum Samples Drawn by Emergency Department Personnel versus Laboratory Phlebotomists
    • Burns E, Yoshikawa N. Hemolysis in Serum Samples Drawn by Emergency Department Personnel versus Laboratory Phlebotomists. Lab Med 2002;33:378-80.
    • (2002) Lab Med , vol.33 , pp. 378-380
    • Burns, E.1    Yoshikawa, N.2
  • 36
    • 84922481228 scopus 로고    scopus 로고
    • A survey of some pre-analytical errors identified from the Biochemistry Department of a Scottish hospital
    • Davidson DF. A survey of some pre-analytical errors identified from the Biochemistry Department of a Scottish hospital. Scott Med J 2014;59:91-4.
    • (2014) Scott Med J , vol.59 , pp. 91-94
    • Davidson, D.F.1
  • 37
    • 55549123560 scopus 로고    scopus 로고
    • Observational study to determine factors associated with blood sample haemolysis in the emergency department
    • Ong ME, Chan YH, Lim CS. Observational study to determine factors associated with blood sample haemolysis in the emergency department. Ann Aca Med, Singapore 2008;37:745-8.
    • (2008) Ann Aca Med, Singapore , vol.37 , pp. 745-748
    • Ong, M.E.1    Chan, Y.H.2    Lim, C.S.3
  • 38
    • 84893936651 scopus 로고    scopus 로고
    • Preanalytical quality in clinical chemistry laboratory
    • Ahmad MI, Ramesh KL, Kumar R. Preanalytical quality in clinical chemistry laboratory. Clin Lab 2014;60:87-92.
    • (2014) Clin Lab , vol.60 , pp. 87-92
    • Ahmad, M.I.1    Ramesh, K.L.2    Kumar, R.3
  • 41
    • 84977740381 scopus 로고    scopus 로고
    • Influence of the serum sample tubes on hemolysis
    • Goegebuer T. Influence of the serum sample tubes on hemolysis. Focus Diagnostica 2008;16:22-5.
    • (2008) Focus Diagnostica , vol.16 , pp. 22-25
    • Goegebuer, T.1
  • 42
    • 84945457358 scopus 로고    scopus 로고
    • Systematic assessment of the hemolysis index: Pros and cons
    • Lippi G. Systematic Assessment of the Hemolysis Index: Pros and Cons. Adv Clin Chem 2015;71:157-70.
    • (2015) Adv Clin Chem , vol.71 , pp. 157-170
    • Lippi, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.