메뉴 건너뛰기




Volumn 72, Issue 3, 2014, Pages 726-736

Oscillating gradient spin-echo (OGSE) diffusion tensor imaging of the human brain

Author keywords

diffusion; diffusion time; DTI; eigenvalue; human; OGSE

Indexed keywords

BRAIN; CLUSTERING ALGORITHMS; DIFFUSION; EIGENVALUES AND EIGENFUNCTIONS; IMAGE SEGMENTATION; MAGNETIC RESONANCE IMAGING; SPIN POLARIZATION; TENSORS;

EID: 85028195916     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24987     Document Type: Article
Times cited : (116)

References (39)
  • 1
    • 0028007061 scopus 로고
    • Water diffusion in the giant axon of the squid: Implications for diffusion-weighted MRI of the nervous system
    • Beaulieu C, Allen PS,. Water diffusion in the giant axon of the squid: implications for diffusion-weighted MRI of the nervous system. Magn Reson Med 1994; 32: 579-583.
    • (1994) Magn Reson Med , vol.32 , pp. 579-583
    • Beaulieu, C.1    Allen, P.S.2
  • 3
    • 36849100445 scopus 로고
    • Restricted self-diffusion of protons in colloidal systems by the pulsed-gradient, spin-echo method
    • Tanner JE, Stejskal EO,. Restricted self-diffusion of protons in colloidal systems by the pulsed-gradient, spin-echo method. J Chem Phys 1968; 49: 1768-1777.
    • (1968) J Chem Phys , vol.49 , pp. 1768-1777
    • Tanner, J.E.1    Stejskal, E.O.2
  • 4
    • 33646376290 scopus 로고
    • Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
    • Stejskal EO, Tanner JE,. Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J Chem Phys 1965; 42: 288-292.
    • (1965) J Chem Phys , vol.42 , pp. 288-292
    • Stejskal, E.O.1    Tanner, J.E.2
  • 5
    • 0029990703 scopus 로고    scopus 로고
    • An in vitro evaluation of the effects of local magnetic-susceptibility- induced gradients on anisotropic water diffusion in nerve
    • Beaulieu C, Allen PS,. An in vitro evaluation of the effects of local magnetic-susceptibility-induced gradients on anisotropic water diffusion in nerve. Magn Reson Med 1996; 36: 39-44.
    • (1996) Magn Reson Med , vol.36 , pp. 39-44
    • Beaulieu, C.1    Allen, P.S.2
  • 6
    • 0029901033 scopus 로고    scopus 로고
    • Diffusion of water in rat sciatic nerve measured by H-1 pulsed field gradient NMR: Compartmentation and anisotropy
    • Seo Y, Morita Y, Kusaka Y, Steward MC, Murakami M,. Diffusion of water in rat sciatic nerve measured by H-1 pulsed field gradient NMR: compartmentation and anisotropy. Jpn J Physiol 1996; 46: 163-169.
    • (1996) Jpn J Physiol , vol.46 , pp. 163-169
    • Seo, Y.1    Morita, Y.2    Kusaka, Y.3    Steward, M.C.4    Murakami, M.5
  • 7
    • 0031595078 scopus 로고    scopus 로고
    • Diffusional anisotropy of T2 components in bovine optic nerve
    • Stanisz GJ, Henkelman RM,. Diffusional anisotropy of T2 components in bovine optic nerve. Magn Reson Med 1998; 40: 405-410.
    • (1998) Magn Reson Med , vol.40 , pp. 405-410
    • Stanisz, G.J.1    Henkelman, R.M.2
  • 8
    • 40449093588 scopus 로고    scopus 로고
    • High b-value q-space diffusion MRS of nerves: Structural information and comparison with histological evidence
    • Bar-Shir A, Cohen Y,. High b-value q-space diffusion MRS of nerves: structural information and comparison with histological evidence. NMR Biomed 2008; 21: 165-174.
    • (2008) NMR Biomed , vol.21 , pp. 165-174
    • Bar-Shir, A.1    Cohen, Y.2
  • 9
    • 0028007064 scopus 로고
    • Detection of apparent restricted diffusion in healthy rat brain at short diffusion times
    • Niendorf T, Norris DG, Leibfritz D,. Detection of apparent restricted diffusion in healthy rat brain at short diffusion times. Magn Reson Med 1994; 32: 672-677.
    • (1994) Magn Reson Med , vol.32 , pp. 672-677
    • Niendorf, T.1    Norris, D.G.2    Leibfritz, D.3
  • 10
    • 0027193910 scopus 로고
    • Is water diffusion restricted in human brain white-matter - An echo-planar NMR imaging study
    • Lebihan D, Turner R, Douek P,. Is water diffusion restricted in human brain white-matter-an echo-planar NMR imaging study. Neuroreport 1993; 4: 887-890.
    • (1993) Neuroreport , vol.4 , pp. 887-890
    • Lebihan, D.1    Turner, R.2    Douek, P.3
  • 11
    • 0035009451 scopus 로고    scopus 로고
    • Diffusion time dependence of the apparent diffusion tensor in healthy human brain and white matter disease
    • Clark CA, Hedehus M, Moseley ME,. Diffusion time dependence of the apparent diffusion tensor in healthy human brain and white matter disease. Magn Reson Med 2001; 45: 1126-1129.
    • (2001) Magn Reson Med , vol.45 , pp. 1126-1129
    • Clark, C.A.1    Hedehus, M.2    Moseley, M.E.3
  • 12
    • 59249099382 scopus 로고    scopus 로고
    • On the effects of a varied diffusion time in vivo: Is the diffusion in white matter restricted?
    • Nilsson M, Latt J, Nordh E, Wirestam R, Stahlberg F, Brockstedt S,. On the effects of a varied diffusion time in vivo: is the diffusion in white matter restricted? Magn Reson Imaging 2009; 27: 176-187.
    • (2009) Magn Reson Imaging , vol.27 , pp. 176-187
    • Nilsson, M.1    Latt, J.2    Nordh, E.3    Wirestam, R.4    Stahlberg, F.5    Brockstedt, S.6
  • 15
    • 0001091376 scopus 로고
    • Application of spin-echo method in measurement of auto-diffusion
    • Gross B, Kosfeld R,. Application of spin-echo method in measurement of auto-diffusion. Messtechnik 1969; 77: 171.
    • (1969) Messtechnik , vol.77 , pp. 171
    • Gross, B.1    Kosfeld, R.2
  • 16
    • 0034571933 scopus 로고    scopus 로고
    • Measurements of restricted diffusion using an oscillating gradient spin-echo sequence
    • Schachter M, Does MD, Anderson AW, Gore JC,. Measurements of restricted diffusion using an oscillating gradient spin-echo sequence. J Magn Reson 2000; 147: 232-237.
    • (2000) J Magn Reson , vol.147 , pp. 232-237
    • Schachter, M.1    Does, M.D.2    Anderson, A.W.3    Gore, J.C.4
  • 17
    • 78650457456 scopus 로고    scopus 로고
    • Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy
    • Gore JC, Xu J, Colvin DC, Yankeelov TE, Parsons EC, Does MD,. Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy. NMR Biomed 2010; 23: 745-756.
    • (2010) NMR Biomed , vol.23 , pp. 745-756
    • Gore, J.C.1    Xu, J.2    Colvin, D.C.3    Yankeelov, T.E.4    Parsons, E.C.5    Does, M.D.6
  • 18
    • 79952535526 scopus 로고    scopus 로고
    • Dependence of temporal diffusion spectra on microstructural properties of biological tissues
    • Xu J, Does MD, Gore JC,. Dependence of temporal diffusion spectra on microstructural properties of biological tissues. Magn Reson Imaging 2011; 29: 380-390.
    • (2011) Magn Reson Imaging , vol.29 , pp. 380-390
    • Xu, J.1    Does, M.D.2    Gore, J.C.3
  • 19
    • 69949143857 scopus 로고    scopus 로고
    • Quantitative characterization of tissue microstructure with temporal diffusion spectroscopy
    • Xu J, Does MD, Gore JC,. Quantitative characterization of tissue microstructure with temporal diffusion spectroscopy. J Magn Reson 2009; 200: 189-197.
    • (2009) J Magn Reson , vol.200 , pp. 189-197
    • Xu, J.1    Does, M.D.2    Gore, J.C.3
  • 20
    • 79955072960 scopus 로고    scopus 로고
    • Surface-to-volume ratio with oscillating gradients
    • Novikov DS, Kiselev VG,. Surface-to-volume ratio with oscillating gradients. J Magn Reson 2011; 210: 141-145.
    • (2011) J Magn Reson , vol.210 , pp. 141-145
    • Novikov, D.S.1    Kiselev, V.G.2
  • 21
    • 12244265509 scopus 로고    scopus 로고
    • Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
    • Does MD, Parsons EC, Gore JC,. Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain. Magn Reson Med 2003; 49: 206-215.
    • (2003) Magn Reson Med , vol.49 , pp. 206-215
    • Does, M.D.1    Parsons, E.C.2    Gore, J.C.3
  • 22
    • 84355163083 scopus 로고    scopus 로고
    • Probing mouse brain microstructure using oscillating gradient diffusion MRI
    • Aggarwal M, Jones MV, Calabresi PA, Mori S, Zhang J,. Probing mouse brain microstructure using oscillating gradient diffusion MRI. Magn Reson Med 2012; 67: 98-109.
    • (2012) Magn Reson Med , vol.67 , pp. 98-109
    • Aggarwal, M.1    Jones, M.V.2    Calabresi, P.A.3    Mori, S.4    Zhang, J.5
  • 23
    • 84872352386 scopus 로고    scopus 로고
    • Systematic changes to the apparent diffusion tensor of in vivo rat brain measured with an oscillating-gradient spin-echo sequence
    • Kershaw J, Leuze C, Aoki I, Obata T, Kanno I, Ito H, Yamaguchi Y, Handa H,. Systematic changes to the apparent diffusion tensor of in vivo rat brain measured with an oscillating-gradient spin-echo sequence. Neuroimage 2013; 70: 10-20.
    • (2013) Neuroimage , vol.70 , pp. 10-20
    • Kershaw, J.1    Leuze, C.2    Aoki, I.3    Obata, T.4    Kanno, I.5    Ito, H.6    Yamaguchi, Y.7    Handa, H.8
  • 24
    • 80051686009 scopus 로고    scopus 로고
    • Changes in intracellular water diffusion and energetic metabolism in response to ischemia in perfused C6 rat glioma cells
    • Harkins KD, Galons J-P, Divijak JL, Trouard TP,. Changes in intracellular water diffusion and energetic metabolism in response to ischemia in perfused C6 rat glioma cells. Magn Reson Med 2011; 66: 859-867.
    • (2011) Magn Reson Med , vol.66 , pp. 859-867
    • Harkins, K.D.1    Galons, J.-P.2    Divijak, J.L.3    Trouard, T.P.4
  • 25
    • 66249098416 scopus 로고    scopus 로고
    • Sensitivity of MR diffusion measurements to variations in intracellular structure: Effects of nuclear size
    • Xu J, Does MD, Gore JC,. Sensitivity of MR diffusion measurements to variations in intracellular structure: effects of nuclear size. Magn Reson Med 2009; 61: 828-833.
    • (2009) Magn Reson Med , vol.61 , pp. 828-833
    • Xu, J.1    Does, M.D.2    Gore, J.C.3
  • 27
    • 84890805320 scopus 로고    scopus 로고
    • In vivo investigation of restricted diffusion in the human brain with optimized oscillating diffusion gradient encoding
    • Van AT, Holdsworth SJ, Bammer R,. In vivo investigation of restricted diffusion in the human brain with optimized oscillating diffusion gradient encoding. Magn Reson Med 2014; 71: 83-94.
    • (2014) Magn Reson Med , vol.71 , pp. 83-94
    • Van, A.T.1    Holdsworth, S.J.2    Bammer, R.3
  • 28
    • 0038106387 scopus 로고    scopus 로고
    • Modified oscillating gradient pulses for direct sampling of the diffusion spectrum suitable for imaging sequences
    • Parsons EC, Does MD, Gore JC,. Modified oscillating gradient pulses for direct sampling of the diffusion spectrum suitable for imaging sequences. Magn Reson Imaging 2003; 21: 279-285.
    • (2003) Magn Reson Imaging , vol.21 , pp. 279-285
    • Parsons, E.C.1    Does, M.D.2    Gore, J.C.3
  • 29
    • 84871130663 scopus 로고    scopus 로고
    • Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI
    • Ianuş A, Siow B, Drobnjak I, Zhang H, Alexander DC,. Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI. J Magn Reson 2013; 227: 25-34.
    • (2013) J Magn Reson , vol.227 , pp. 25-34
    • Ianuş, A.1    Siow, B.2    Drobnjak, I.3    Zhang, H.4    Alexander, D.C.5
  • 30
    • 84875366035 scopus 로고    scopus 로고
    • Oscillating and pulsed gradient diffusion magnetic resonance microscopy over an extended b-value range: Implications for the characterization of tissue microstructure
    • Portnoy S, Flint JJ, Blackband SJ, Stanisz GJ,. Oscillating and pulsed gradient diffusion magnetic resonance microscopy over an extended b-value range: implications for the characterization of tissue microstructure. Magn Reson Med 2013; 69: 1131-1145.
    • (2013) Magn Reson Med , vol.69 , pp. 1131-1145
    • Portnoy, S.1    Flint, J.J.2    Blackband, S.J.3    Stanisz, G.J.4
  • 31
    • 0023622508 scopus 로고
    • Reduction of pulsed gradient settling time in the superconducting magnet of a magnetic resonance instrument
    • Jensen DJ, Brey WW, Delayre JL, Narayana PA,. Reduction of pulsed gradient settling time in the superconducting magnet of a magnetic resonance instrument. Med Phys 1987; 14: 859-862.
    • (1987) Med Phys , vol.14 , pp. 859-862
    • Jensen, D.J.1    Brey, W.W.2    Delayre, J.L.3    Narayana, P.A.4
  • 32
    • 0001426032 scopus 로고
    • Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems
    • Jehenson P, Westphal M, Schuff N,. Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradients in NMR systems. J Magn Reson (1969) 1990; 90: 264-278.
    • (1990) J Magn Reson (1969) , vol.90 , pp. 264-278
    • Jehenson, P.1    Westphal, M.2    Schuff, N.3
  • 33
    • 0033050286 scopus 로고    scopus 로고
    • Multi-component apparent diffusion coefficients in human brain
    • Mulkern RV, Gudbjartsson H, Westin C-F, et al. Multi-component apparent diffusion coefficients in human brain. NMR Biomed 1999; 12: 51-62.
    • (1999) NMR Biomed , vol.12 , pp. 51-62
    • Mulkern, R.V.1    Gudbjartsson, H.2    Westin, C.-F.3
  • 34
    • 35248816901 scopus 로고    scopus 로고
    • Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
    • Farrell JAD, Landman BA, Jones CK, Smith SA, Prince JL, van Zijl PCM, Mori S,. Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T. J Magn Reson Imaging 2007; 26: 756-767.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 756-767
    • Farrell, J.A.D.1    Landman, B.A.2    Jones, C.K.3    Smith, S.A.4    Prince, J.L.5    Van Zijl, P.C.M.6    Mori, S.7
  • 35
    • 0141840810 scopus 로고    scopus 로고
    • Effects of barrier-induced nuclear spin magnetization inhomogeneities on diffusion-attenuated MR signal
    • Sukstanskii AL, Ackerman JJH, Yablonskiy DA,. Effects of barrier-induced nuclear spin magnetization inhomogeneities on diffusion-attenuated MR signal. Magn Reson Med 2003; 50: 735-742.
    • (2003) Magn Reson Med , vol.50 , pp. 735-742
    • Sukstanskii, A.L.1    Ackerman, J.J.H.2    Yablonskiy, D.A.3
  • 36
    • 84885627455 scopus 로고    scopus 로고
    • Exact analytical results for ADC with oscillating diffusion sensitizing gradients
    • Sukstanskii AL,. Exact analytical results for ADC with oscillating diffusion sensitizing gradients. J Magn Reson 2013; 234: 135-140.
    • (2013) J Magn Reson , vol.234 , pp. 135-140
    • Sukstanskii, A.L.1
  • 37
    • 84861332834 scopus 로고    scopus 로고
    • NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
    • Zhang H, Schneider T, Wheeler-Kingshott CA, Alexander DC,. NODDI: practical in vivo neurite orientation dispersion and density imaging of the human brain. Neuroimage 2012; 61: 1000-1016.
    • (2012) Neuroimage , vol.61 , pp. 1000-1016
    • Zhang, H.1    Schneider, T.2    Wheeler-Kingshott, C.A.3    Alexander, D.C.4
  • 38
    • 58149210839 scopus 로고
    • Effects of finite gradient-pulse widths in pulsed-field-gradient diffusion measurements
    • Mitra PP, Halperin BI,. Effects of finite gradient-pulse widths in pulsed-field-gradient diffusion measurements. J Magn Reson Ser A 1995; 113: 94-101.
    • (1995) J Magn Reson ser A , vol.113 , pp. 94-101
    • Mitra, P.P.1    Halperin, B.I.2
  • 39
    • 77951974806 scopus 로고    scopus 로고
    • The effect of finite diffusion gradient pulse duration on fibre orientation estimation in diffusion MRI
    • Yeh C-H, Tournier JD, Cho K-H, Lin C-P, Calamante F, Connelly A,. The effect of finite diffusion gradient pulse duration on fibre orientation estimation in diffusion MRI. Neuroimage 2010; 51: 743-751.
    • (2010) Neuroimage , vol.51 , pp. 743-751
    • Yeh, C.-H.1    Tournier, J.D.2    Cho, K.-H.3    Lin, C.-P.4    Calamante, F.5    Connelly, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.