메뉴 건너뛰기




Volumn 7, Issue 7, 2012, Pages

Characterizing tumor response to chemotherapy at various length scales using temporal diffusion spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

BARASERTIB;

EID: 84864253657     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0041714     Document Type: Article
Times cited : (45)

References (37)
  • 1
    • 0024999038 scopus 로고
    • Early detection of regional cerebral ischemia in cats: comparison of diffusion- and T2-weighted MRI and spectroscopy
    • Moseley ME, Cohen Y, Mintorovitch J, Chileuitt L, Shimizu H, et al. (1990) Early detection of regional cerebral ischemia in cats: comparison of diffusion- and T2-weighted MRI and spectroscopy. Magn Reson Med 14: 330-346.
    • (1990) Magn Reson Med , vol.14 , pp. 330-346
    • Moseley, M.E.1    Cohen, Y.2    Mintorovitch, J.3    Chileuitt, L.4    Shimizu, H.5
  • 2
    • 0027980263 scopus 로고
    • Brain parenchyma apparent diffusion coefficient alterations associated with experimental complex partial status epilepticus
    • Righini A, Pierpaoli C, Alger JR, Di Chiro G, (1994) Brain parenchyma apparent diffusion coefficient alterations associated with experimental complex partial status epilepticus. Magn Reson Imaging 12: 865-871.
    • (1994) Magn Reson Imaging , vol.12 , pp. 865-871
    • Righini, A.1    Pierpaoli, C.2    Alger, J.R.3    Di Chiro, G.4
  • 3
    • 0030047282 scopus 로고    scopus 로고
    • Early detection of treatment response by diffusion-weighted 1H-NMR spectroscopy in a murine tumour in vivo
    • Zhao M, Pipe JG, Bonnett J, Evelhoch JL, (1996) Early detection of treatment response by diffusion-weighted 1H-NMR spectroscopy in a murine tumour in vivo. Br J Cancer 73: 61-64.
    • (1996) Br J Cancer , vol.73 , pp. 61-64
    • Zhao, M.1    Pipe, J.G.2    Bonnett, J.3    Evelhoch, J.L.4
  • 6
    • 0036021696 scopus 로고    scopus 로고
    • Differentiation of clinically benign and malignant breast lesions using diffusion-weighted imaging
    • Guo Y, Cai YQ, Cai ZL, Gao YG, An NY, et al. (2002) Differentiation of clinically benign and malignant breast lesions using diffusion-weighted imaging. J Magn Reson Imaging 16: 172-178.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 172-178
    • Guo, Y.1    Cai, Y.Q.2    Cai, Z.L.3    Gao, Y.G.4    An, N.Y.5
  • 7
    • 0030753231 scopus 로고    scopus 로고
    • Monitoring early response of experimental brain tumors to therapy using diffusion magnetic resonance imaging
    • Chenevert TL, McKeever PE, Ross BD, (1997) Monitoring early response of experimental brain tumors to therapy using diffusion magnetic resonance imaging. Clin Cancer Res 3: 1457-1466.
    • (1997) Clin Cancer Res , vol.3 , pp. 1457-1466
    • Chenevert, T.L.1    McKeever, P.E.2    Ross, B.D.3
  • 8
    • 20244364105 scopus 로고    scopus 로고
    • Functional diffusion map: a noninvasive MRI biomarker for early stratification of clinical brain tumor response
    • Moffat BA, Chenevert TL, Lawrence TS, Meyer CR, Johnson TD, et al. (2005) Functional diffusion map: a noninvasive MRI biomarker for early stratification of clinical brain tumor response. Proc Natl Acad Sci U S A 102: 5524-5529.
    • (2005) Proc Natl Acad Sci U S A , vol.102 , pp. 5524-5529
    • Moffat, B.A.1    Chenevert, T.L.2    Lawrence, T.S.3    Meyer, C.R.4    Johnson, T.D.5
  • 9
    • 33646404891 scopus 로고    scopus 로고
    • The functional diffusion map: an imaging biomarker for the early prediction of cancer treatment outcome
    • Moffat BA, Chenevert TL, Meyer CR, McKeever PE, Hall DE, et al. (2006) The functional diffusion map: an imaging biomarker for the early prediction of cancer treatment outcome. Neoplasia 8: 259-267.
    • (2006) Neoplasia , vol.8 , pp. 259-267
    • Moffat, B.A.1    Chenevert, T.L.2    Meyer, C.R.3    McKeever, P.E.4    Hall, D.E.5
  • 10
    • 61349123591 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations
    • Padhani AR, Liu G, Koh DM, Chenevert TL, Thoeny HC, et al. (2009) Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11: 102-125.
    • (2009) Neoplasia , vol.11 , pp. 102-125
    • Padhani, A.R.1    Liu, G.2    Koh, D.M.3    Chenevert, T.L.4    Thoeny, H.C.5
  • 11
    • 33646376290 scopus 로고
    • Spin diffusion measurements - spin echoes in presence of a time-dependent field gradient
    • Stejskal EO, Tanner JE, (1965) Spin diffusion measurements- spin echoes in presence of a time-dependent field gradient. J Chem Phys 42: 288-292.
    • (1965) J Chem Phys , vol.42 , pp. 288-292
    • Stejskal, E.O.1    Tanner, J.E.2
  • 12
    • 0032904225 scopus 로고    scopus 로고
    • Usefulness of diffusion-weighted MRI with echo-planar technique in the evaluation of cellularity in gliomas
    • Sugahara T, Korogi Y, Kochi M, Ikushima I, Shigematu Y, et al. (1999) Usefulness of diffusion-weighted MRI with echo-planar technique in the evaluation of cellularity in gliomas. J Magn Reson Imaging 9: 53-60.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 53-60
    • Sugahara, T.1    Korogi, Y.2    Kochi, M.3    Ikushima, I.4    Shigematu, Y.5
  • 14
    • 0034119889 scopus 로고    scopus 로고
    • Measurement of cell density and necrotic fraction in human melanoma xenografts by diffusion weighted magnetic resonance imaging
    • Lyng H, Haraldseth O, Rofstad EK, (2000) Measurement of cell density and necrotic fraction in human melanoma xenografts by diffusion weighted magnetic resonance imaging. Magn Reson Med 43: 828-836.
    • (2000) Magn Reson Med , vol.43 , pp. 828-836
    • Lyng, H.1    Haraldseth, O.2    Rofstad, E.K.3
  • 15
    • 66249098416 scopus 로고    scopus 로고
    • Sensitivity of MR diffusion measurements to variations in intracellular structure: Effects of nuclear size
    • Xu J, Does MD, Gore JC, (2009) Sensitivity of MR diffusion measurements to variations in intracellular structure: Effects of nuclear size. Magn Reson Med 61: 828-833.
    • (2009) Magn Reson Med , vol.61 , pp. 828-833
    • Xu, J.1    Does, M.D.2    Gore, J.C.3
  • 16
    • 78650457456 scopus 로고    scopus 로고
    • Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy
    • Gore JC, Xu J, Colvin DC, Yankeelov TE, Parsons EC, et al. (2010) Characterization of tissue structure at varying length scales using temporal diffusion spectroscopy. NMR Biomed 23: 745-756.
    • (2010) NMR Biomed , vol.23 , pp. 745-756
    • Gore, J.C.1    Xu, J.2    Colvin, D.C.3    Yankeelov, T.E.4    Parsons, E.C.5
  • 17
    • 30344478262 scopus 로고    scopus 로고
    • Temporal diffusion spectroscopy: theory and implementation in restricted systems using oscillating gradients
    • Parsons EC Jr, Does MD, Gore JC, (2006) Temporal diffusion spectroscopy: theory and implementation in restricted systems using oscillating gradients. Magn Reson Med 55: 75-84.
    • (2006) Magn Reson Med , vol.55 , pp. 75-84
    • Parsons Jr., E.C.1    Does, M.D.2    Gore, J.C.3
  • 18
    • 48649085915 scopus 로고    scopus 로고
    • New insights into tumor microstructure using temporal diffusion spectroscopy
    • Colvin DC, Yankeelov TE, Does MD, Yue Z, Quarles C, et al. (2008) New insights into tumor microstructure using temporal diffusion spectroscopy. Cancer Res 68: 5941-5947.
    • (2008) Cancer Res , vol.68 , pp. 5941-5947
    • Colvin, D.C.1    Yankeelov, T.E.2    Does, M.D.3    Yue, Z.4    Quarles, C.5
  • 19
    • 79951843510 scopus 로고    scopus 로고
    • Effects of intracellular organelles on the apparent diffusion coefficient of water molecules in cultured human embryonic kidney cells
    • Colvin DC, Jourquin J, Xu J, Does MD, Estrada L, et al. (2011) Effects of intracellular organelles on the apparent diffusion coefficient of water molecules in cultured human embryonic kidney cells. Magn Reson Med 65: 796-801.
    • (2011) Magn Reson Med , vol.65 , pp. 796-801
    • Colvin, D.C.1    Jourquin, J.2    Xu, J.3    Does, M.D.4    Estrada, L.5
  • 20
    • 79952807260 scopus 로고    scopus 로고
    • Influence of cell cycle phase on apparent diffusion coefficient in synchronized cells detected using temporal diffusion spectroscopy
    • Xu J, Xie J, Jourquin J, Colvin DC, Does MD, et al. (2011) Influence of cell cycle phase on apparent diffusion coefficient in synchronized cells detected using temporal diffusion spectroscopy. Magn Reson Med 65: 920-926.
    • (2011) Magn Reson Med , vol.65 , pp. 920-926
    • Xu, J.1    Xie, J.2    Jourquin, J.3    Colvin, D.C.4    Does, M.D.5
  • 21
    • 79952533315 scopus 로고    scopus 로고
    • Earlier detection of tumor treatment response using magnetic resonance diffusion imaging with oscillating gradients
    • Colvin DC, Loveless ME, Does MD, Yue Z, Yankeelov TE, et al. (2011) Earlier detection of tumor treatment response using magnetic resonance diffusion imaging with oscillating gradients. Magn Reson Imaging 29: 315-323.
    • (2011) Magn Reson Imaging , vol.29 , pp. 315-323
    • Colvin, D.C.1    Loveless, M.E.2    Does, M.D.3    Yue, Z.4    Yankeelov, T.E.5
  • 22
    • 34250739960 scopus 로고    scopus 로고
    • AZD1152, a selective inhibitor of Aurora B kinase, inhibits human tumor xenograft growth by inducing apoptosis
    • Wilkinson RW, Odedra R, Heaton SP, Wedge SR, Keen NJ, et al. (2007) AZD1152, a selective inhibitor of Aurora B kinase, inhibits human tumor xenograft growth by inducing apoptosis. Clin Cancer Res 13: 3682-3688.
    • (2007) Clin Cancer Res , vol.13 , pp. 3682-3688
    • Wilkinson, R.W.1    Odedra, R.2    Heaton, S.P.3    Wedge, S.R.4    Keen, N.J.5
  • 23
    • 79952265709 scopus 로고    scopus 로고
    • Imaging colon cancer response following treatment with AZD1152: a preclinical analysis of [18F]fluoro-2-deoxyglucose and 3′-deoxy-3′-[18F]fluorothymidine imaging
    • Moroz MA, Kochetkov T, Cai S, Wu J, Shamis M, et al. (2011) Imaging colon cancer response following treatment with AZD1152: a preclinical analysis of [18F]fluoro-2-deoxyglucose and 3′-deoxy-3′-[18F]fluorothymidine imaging. Clin Cancer Res 17: 1099-1110.
    • (2011) Clin Cancer Res , vol.17 , pp. 1099-1110
    • Moroz, M.A.1    Kochetkov, T.2    Cai, S.3    Wu, J.4    Shamis, M.5
  • 24
    • 84864259535 scopus 로고    scopus 로고
    • Nuclear magnetic resonance methods for the analysis of water diffusion in neural tissue: Yale University
    • Parsons EC, (2002) Nuclear magnetic resonance methods for the analysis of water diffusion in neural tissue: Yale University.
    • (2002)
    • Parsons, E.C.1
  • 25
    • 0031711474 scopus 로고    scopus 로고
    • A motion correction scheme by twin-echo navigation for diffusion-weighted magnetic resonance imaging with multiple RF echo acquisition
    • Mori S, van Zijl PC, (1998) A motion correction scheme by twin-echo navigation for diffusion-weighted magnetic resonance imaging with multiple RF echo acquisition. Magn Reson Med 40: 511-516.
    • (1998) Magn Reson Med , vol.40 , pp. 511-516
    • Mori, S.1    van Zijl, P.C.2
  • 26
    • 84355163083 scopus 로고    scopus 로고
    • Probing mouse brain microstructure using oscillating gradient diffusion MRI
    • Aggarwal M, Jones MV, Calabresi PA, Mori S, Zhang J, (2012) Probing mouse brain microstructure using oscillating gradient diffusion MRI. Magn Reson Med 67: 98-109.
    • (2012) Magn Reson Med , vol.67 , pp. 98-109
    • Aggarwal, M.1    Jones, M.V.2    Calabresi, P.A.3    Mori, S.4    Zhang, J.5
  • 27
    • 79952535526 scopus 로고    scopus 로고
    • Dependence of temporal diffusion spectra on microstructural properties of biological tissues
    • Xu J, Does MD, Gore JC, (2011) Dependence of temporal diffusion spectra on microstructural properties of biological tissues. Magn Reson Imaging 29: 380-390.
    • (2011) Magn Reson Imaging , vol.29 , pp. 380-390
    • Xu, J.1    Does, M.D.2    Gore, J.C.3
  • 28
    • 0019551312 scopus 로고
    • Analysis of NMR self-diffusion measurements by a density-matrix calculation
    • Stepisnik J, (1981) Analysis of NMR self-diffusion measurements by a density-matrix calculation. Physica B 104: 350-364.
    • (1981) Physica B , vol.104 , pp. 350-364
    • Stepisnik, J.1
  • 30
    • 0347762556 scopus 로고    scopus 로고
    • From polyploidy to aneuploidy, genome instability and cancer
    • Storchova Z, Pellman D, (2004) From polyploidy to aneuploidy, genome instability and cancer. Nat Rev Mol Cell Biol 5: 45-54.
    • (2004) Nat Rev Mol Cell Biol , vol.5 , pp. 45-54
    • Storchova, Z.1    Pellman, D.2
  • 31
    • 84864207441 scopus 로고    scopus 로고
    • Diffusion Tensor Imaging, Using Oscillating Gradients to Probe Short Diffusion Times
    • July; Toronto, Canada
    • Hosey TP, Harding SG, Green HA, Ansorge RE, Carpenter TA. Diffusion Tensor Imaging, Using Oscillating Gradients to Probe Short Diffusion Times, in the Human Brain.; 2003 July; Toronto, Canada.
    • (2003) The Human Brain
    • Hosey, T.P.1    Harding, S.G.2    Green, H.A.3    Ansorge, R.E.4    Carpenter, T.A.5
  • 34
    • 0025944437 scopus 로고
    • A simple method for obtaining cross-term-free images for diffusion anisotropy studies in NMR microimaging
    • Neeman M, Freyer JP, Sillerud LO, (1991) A simple method for obtaining cross-term-free images for diffusion anisotropy studies in NMR microimaging. Magn Reson Med 21: 138-143.
    • (1991) Magn Reson Med , vol.21 , pp. 138-143
    • Neeman, M.1    Freyer, J.P.2    Sillerud, L.O.3
  • 35
    • 0001562705 scopus 로고
    • Measuring diffusion in inhomogeneous systems in imaging mode using antisymmetric sensitizing gradients
    • Hong X, Thomas Dixon W, (1992) Measuring diffusion in inhomogeneous systems in imaging mode using antisymmetric sensitizing gradients. J Magn Reson 99: 561-570.
    • (1992) J Magn Reson , vol.99 , pp. 561-570
    • Hong, X.1    Thomas Dixon, W.2
  • 36
    • 0026098418 scopus 로고
    • The use of gradient flow compensation to separate diffusion and microcirculatory flow in MRI
    • Maki JH, MacFall JR, Johnson GA, (1991) The use of gradient flow compensation to separate diffusion and microcirculatory flow in MRI. Magn Reson Med 17: 95-107.
    • (1991) Magn Reson Med , vol.17 , pp. 95-107
    • Maki, J.H.1    MacFall, J.R.2    Johnson, G.A.3
  • 37
    • 12244265509 scopus 로고    scopus 로고
    • Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
    • Does MD, Parsons EC, Gore JC, (2003) Oscillating gradient measurements of water diffusion in normal and globally ischemic rat brain. Magn Reson Med 49: 206-215.
    • (2003) Magn Reson Med , vol.49 , pp. 206-215
    • Does, M.D.1    Parsons, E.C.2    Gore, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.