메뉴 건너뛰기




Volumn 10, Issue 20, 2017, Pages 2078-2087

Multicenter Comparison of Novel Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves

Author keywords

ACURATE neo; SAPIEN 3; transcatheter aortic valve replacement; VARC 2

Indexed keywords

ACUTE KIDNEY FAILURE; AGED; ARTICLE; BLEEDING; CEREBROVASCULAR ACCIDENT; COMPARATIVE STUDY; CONTROLLED STUDY; CORONARY ARTERY OBSTRUCTION; DEVICE SAFETY; FEMALE; GERMANY; HEART INFARCTION; HUMAN; KIDNEY FAILURE; MAJOR ADVERSE CARDIAC EVENT; MAJOR CLINICAL STUDY; MALE; MORTALITY RATE; MULTICENTER STUDY; PACEMAKER IMPLANTATION; PARAVALVULAR LEAK; PRIORITY JOURNAL; PROSTHESIS COMPLICATION; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT OUTCOME; VERY ELDERLY; AORTIC VALVE; AORTIC VALVE STENOSIS; CLINICAL TRIAL; DEVICES; DIAGNOSTIC IMAGING; HEART PACING; HEART VALVE PROSTHESIS; KAPLAN MEIER METHOD; MORTALITY; MULTIDETECTOR COMPUTED TOMOGRAPHY; ODDS RATIO; PATHOPHYSIOLOGY; PROCEDURES; PROPENSITY SCORE; PROPORTIONAL HAZARDS MODEL; PROSTHESIS DESIGN; REGISTER; RISK FACTOR; SEVERITY OF ILLNESS INDEX; STATISTICAL MODEL; TIME FACTOR; TRANSLUMINAL VALVULOPLASTY;

EID: 85025830489     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2017.06.026     Document Type: Article
Times cited : (84)

References (22)
  • 1
    • 84903695761 scopus 로고    scopus 로고
    • The German Aortic Valve Registry (GARY): in-hospital outcome
    • Hamm, C.W., Möllmann, H., Holzhey, D., et al. The German Aortic Valve Registry (GARY): in-hospital outcome. Eur Heart J 35 (2014), 1588–1598.
    • (2014) Eur Heart J , vol.35 , pp. 1588-1598
    • Hamm, C.W.1    Möllmann, H.2    Holzhey, D.3
  • 2
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aortic-valve implantation in high-risk patients
    • Gilard, M., Eltchaninoff, H., Iung, B., et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med 366 (2012), 1705–1715.
    • (2012) N Engl J Med , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3
  • 3
    • 84898644090 scopus 로고    scopus 로고
    • Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial
    • Abdel-Wahab, M., Mehilli, J., Frerker, C., et al. Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA 311 (2014), 1503–1514.
    • (2014) JAMA , vol.311 , pp. 1503-1514
    • Abdel-Wahab, M.1    Mehilli, J.2    Frerker, C.3
  • 4
    • 84939492199 scopus 로고    scopus 로고
    • 1-Year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: results from the CHOICE Randomized Clinical Trial
    • Abdel-Wahab, M., Neumann, F.-J., Mehilli, J., et al. 1-Year outcomes after transcatheter aortic valve replacement with balloon-expandable versus self-expandable valves: results from the CHOICE Randomized Clinical Trial. J Am Coll Cardiol 66 (2015), 791–800.
    • (2015) J Am Coll Cardiol , vol.66 , pp. 791-800
    • Abdel-Wahab, M.1    Neumann, F.-J.2    Mehilli, J.3
  • 5
    • 84991625019 scopus 로고    scopus 로고
    • Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis
    • Kodali, S., Thourani, V.H., White, J., et al. Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis. Eur Heart J 37 (2016), 2252–2262.
    • (2016) Eur Heart J , vol.37 , pp. 2252-2262
    • Kodali, S.1    Thourani, V.H.2    White, J.3
  • 6
    • 84955473073 scopus 로고    scopus 로고
    • Outcomes after transcatheter aortic valve replacement using a novel balloon-expandable transcatheter heart valve: a single-center experience
    • Husser, O., Pellegrini, C., Kessler, T., et al. Outcomes after transcatheter aortic valve replacement using a novel balloon-expandable transcatheter heart valve: a single-center experience. J Am Coll Cardiol Intv 8 (2015), 1809–1816.
    • (2015) J Am Coll Cardiol Intv , vol.8 , pp. 1809-1816
    • Husser, O.1    Pellegrini, C.2    Kessler, T.3
  • 8
    • 84866983406 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document
    • Kappetein, A.P., Head, S.J., Généreux, P., et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Am Coll Cardiol 60 (2012), 1438–1454.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1438-1454
    • Kappetein, A.P.1    Head, S.J.2    Généreux, P.3
  • 9
    • 84870743337 scopus 로고    scopus 로고
    • SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    • Achenbach, S., Delgado, V., Hausleiter, J., Schoenhagen, P., Min, J.K., Leipsic, J.A., SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR). J Cardiovasc Comput Tomogr 6 (2012), 366–380.
    • (2012) J Cardiovasc Comput Tomogr , vol.6 , pp. 366-380
    • Achenbach, S.1    Delgado, V.2    Hausleiter, J.3    Schoenhagen, P.4    Min, J.K.5    Leipsic, J.A.6
  • 10
    • 84880591192 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve
    • Binder, R.K., Rodés-Cabau, J., Wood, D.A., et al. Transcatheter aortic valve replacement with the SAPIEN 3: a new balloon-expandable transcatheter heart valve. J Am Coll Cardiol Intv 6 (2013), 293–300.
    • (2013) J Am Coll Cardiol Intv , vol.6 , pp. 293-300
    • Binder, R.K.1    Rodés-Cabau, J.2    Wood, D.A.3
  • 11
    • 84964273473 scopus 로고    scopus 로고
    • Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve
    • Webb, J., Gerosa, G., Lefèvre, T., et al. Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol 64 (2014), 2235–2243.
    • (2014) J Am Coll Cardiol , vol.64 , pp. 2235-2243
    • Webb, J.1    Gerosa, G.2    Lefèvre, T.3
  • 12
    • 79958747321 scopus 로고    scopus 로고
    • MatchIt: nonparametric preprocessing for parametric casual inference
    • Ho, D., King, G., Imai, K., Stuart, E., MatchIt: nonparametric preprocessing for parametric casual inference. J Stat Softw 42 (2011), 1–28.
    • (2011) J Stat Softw , vol.42 , pp. 1-28
    • Ho, D.1    King, G.2    Imai, K.3    Stuart, E.4
  • 13
    • 84964698835 scopus 로고    scopus 로고
    • Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards SAPIEN valve in the PARTNER trial: characterizing patients and impact on outcomes
    • Kodali, S., Pibarot, P., Douglas, P.S., et al. Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards SAPIEN valve in the PARTNER trial: characterizing patients and impact on outcomes. Eur Heart J 36 (2015), 449–456.
    • (2015) Eur Heart J , vol.36 , pp. 449-456
    • Kodali, S.1    Pibarot, P.2    Douglas, P.S.3
  • 14
    • 84862181480 scopus 로고    scopus 로고
    • Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies
    • Généreux, P., Head, S.J., Van Mieghem, N.M., et al. Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies. J Am Coll Cardiol 59 (2012), 2317–2326.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2317-2326
    • Généreux, P.1    Head, S.J.2    Van Mieghem, N.M.3
  • 15
    • 85031724574 scopus 로고    scopus 로고
    • 30-day registry results using a second-generation TF-TAVI system for the treatment of aortic stenosis
    • May 2016, Paris, France.
    • Möllmann, H., 30-day registry results using a second-generation TF-TAVI system for the treatment of aortic stenosis. Oral Presentation EuroPCR, 2016 May 2016, Paris, France.
    • (2016) Oral Presentation EuroPCR
    • Möllmann, H.1
  • 16
    • 85017528488 scopus 로고    scopus 로고
    • Repositionable versus balloon-expandable devices for transcatheter aortic valve implantation in patients with aortic stenosis
    • Pilgrim, T., Stortecky, S., Nietlispach, F., et al. Repositionable versus balloon-expandable devices for transcatheter aortic valve implantation in patients with aortic stenosis. J Am Heart Assoc, 5, 2016, e004088.
    • (2016) J Am Heart Assoc , vol.5 , pp. e004088
    • Pilgrim, T.1    Stortecky, S.2    Nietlispach, F.3
  • 17
    • 85011279075 scopus 로고    scopus 로고
    • SOURCE 3 Registry: design and 30-Day results of the European Postapproval Registry of the Latest Generation of the SAPIEN 3 Transcatheter Heart Valve
    • Wendler, O., Schymik, G., Treede, H., et al. SOURCE 3 Registry: design and 30-Day results of the European Postapproval Registry of the Latest Generation of the SAPIEN 3 Transcatheter Heart Valve. Circulation 135 (2017), 1123–1132.
    • (2017) Circulation , vol.135 , pp. 1123-1132
    • Wendler, O.1    Schymik, G.2    Treede, H.3
  • 18
    • 84860381746 scopus 로고    scopus 로고
    • Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients
    • Eggebrecht, H., Schmermund, A., Voigtländer, T., Kahlert, P., Erbel, R., Mehta, R.H., Risk of stroke after transcatheter aortic valve implantation (TAVI): a meta-analysis of 10,037 published patients. EuroIntervention 8 (2012), 129–138.
    • (2012) EuroIntervention , vol.8 , pp. 129-138
    • Eggebrecht, H.1    Schmermund, A.2    Voigtländer, T.3    Kahlert, P.4    Erbel, R.5    Mehta, R.H.6
  • 19
    • 84992505808 scopus 로고    scopus 로고
    • Improving outcomes: case-matched comparison of novel second-generation versus first-generation self-expandable transcatheter heart valves
    • Schaefer, A., Treede, H., Schoen, G., et al. Improving outcomes: case-matched comparison of novel second-generation versus first-generation self-expandable transcatheter heart valves. Eur J Cardiothorac Surg 50 (2016), 368–373.
    • (2016) Eur J Cardiothorac Surg , vol.50 , pp. 368-373
    • Schaefer, A.1    Treede, H.2    Schoen, G.3
  • 20
    • 84962068334 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis
    • Thourani, V.H., Kodali, S., Makkar, R.R., et al. Transcatheter aortic valve replacement versus surgical valve replacement in intermediate-risk patients: a propensity score analysis. Lancet 387 (2016), 2218–2225.
    • (2016) Lancet , vol.387 , pp. 2218-2225
    • Thourani, V.H.1    Kodali, S.2    Makkar, R.R.3
  • 21
    • 84904007059 scopus 로고    scopus 로고
    • Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis
    • Siontis, G.C.M., Jüni, P., Pilgrim, T., et al. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. J Am Coll Cardiol 64 (2014), 129–140.
    • (2014) J Am Coll Cardiol , vol.64 , pp. 129-140
    • Siontis, G.C.M.1    Jüni, P.2    Pilgrim, T.3
  • 22
    • 84978394576 scopus 로고    scopus 로고
    • One-year clinical outcomes with SAPIEN 3 transcatheter aortic valve replacement in high-risk and inoperable patients with severe aortic stenosis: clinical perspective
    • Herrmann, H.C., Thourani, V.H., Kodali, S.K., et al. One-year clinical outcomes with SAPIEN 3 transcatheter aortic valve replacement in high-risk and inoperable patients with severe aortic stenosis: clinical perspective. Circulation 134 (2016), 130–140.
    • (2016) Circulation , vol.134 , pp. 130-140
    • Herrmann, H.C.1    Thourani, V.H.2    Kodali, S.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.