메뉴 건너뛰기




Volumn 14, Issue 7, 2017, Pages 1016-1023

Development and validation of a dual sensing scheme to improve accuracy of bradycardia and pause detection in an insertable cardiac monitor

Author keywords

Bradycardia; Diagnosis; Insertable cardiac monitors; Pause

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; BRADYCARDIA; CARDIAC IMPLANT; COHORT ANALYSIS; FAINTNESS; FALSE POSITIVE RESULT; FEMALE; FOLLOW UP; HUMAN; INSERTABLE CARDIAC MONITOR; MAJOR CLINICAL STUDY; MALE; PREDICTIVE VALUE; PRIORITY JOURNAL; R WAVE; R WAVE AMPLITUDE; SENSITIVITY AND SPECIFICITY; T WAVE; TACHYCARDIA; ADVERSE DEVICE EFFECT; AGED; AMBULATORY ELECTROCARDIOGRAPHY; COMPLICATION; DEVICES; DIAGNOSTIC ERROR; DIMENSIONAL MEASUREMENT ACCURACY; ELECTRODE IMPLANT; EQUIPMENT DESIGN; MIDDLE AGED; PREVENTION AND CONTROL; PROCEDURES; UNITED STATES; VALIDATION STUDY;

EID: 85019870398     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2017.03.037     Document Type: Article
Times cited : (17)

References (25)
  • 2
    • 0037420077 scopus 로고    scopus 로고
    • Syncope: is a diagnosis a diagnosis?
    • Benditt, D.G., Brignole, M., Syncope: is a diagnosis a diagnosis?. J Am Coll Cardiol 41 (2003), 791–794.
    • (2003) J Am Coll Cardiol , vol.41 , pp. 791-794
    • Benditt, D.G.1    Brignole, M.2
  • 4
    • 0037247790 scopus 로고    scopus 로고
    • Cardiac arrhythmias and risk stratification after myocardial infarction: results of the CARISMA pilot study
    • Huikuri, H.V., Mahaux, V., Bloch-Thomsen, P.E., Cardiac arrhythmias and risk stratification after myocardial infarction: results of the CARISMA pilot study. Pacing Clin Electrophysiol 26 (2003), 416–419.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 416-419
    • Huikuri, H.V.1    Mahaux, V.2    Bloch-Thomsen, P.E.3
  • 5
    • 2442532587 scopus 로고    scopus 로고
    • Insertable loop recorder use for detection of intermittent arrhythmias
    • Krahn, A.D., Klein, G.J., Skanes, A.C., Yee, R., Insertable loop recorder use for detection of intermittent arrhythmias. Pacing Clin Electrophysiol 27 (2004), 657–664.
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 657-664
    • Krahn, A.D.1    Klein, G.J.2    Skanes, A.C.3    Yee, R.4
  • 6
  • 9
    • 70349782860 scopus 로고    scopus 로고
    • Twenty four-hour Holter monitor follow-up does not provide accurate heart rhythm status after surgical atrial fibrillation ablation therapy: up to 12 months experience with a novel permanently implantable heart rhythm monitor device
    • Hanke, T., Charitos, E.I., Stierle, U., Karluss, A., Kraatz, E., Graf, B., Hagemann, A., Misfeld, M., Sievers, H.H., Twenty four-hour Holter monitor follow-up does not provide accurate heart rhythm status after surgical atrial fibrillation ablation therapy: up to 12 months experience with a novel permanently implantable heart rhythm monitor device. Circulation 120 (2009), S177–S184.
    • (2009) Circulation , vol.120 , pp. S177-S184
    • Hanke, T.1    Charitos, E.I.2    Stierle, U.3    Karluss, A.4    Kraatz, E.5    Graf, B.6    Hagemann, A.7    Misfeld, M.8    Sievers, H.H.9
  • 10
    • 84873463815 scopus 로고    scopus 로고
    • Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): a prospective, multicenter study
    • Verma, A., Champagne, J., Sapp, J., Essebag, V., Novak, P., Skanes, A., Morillo, C.A., Khaykin, Y., Birnie, D., Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): a prospective, multicenter study. JAMA Intern Med 173 (2013), 149–156.
    • (2013) JAMA Intern Med , vol.173 , pp. 149-156
    • Verma, A.1    Champagne, J.2    Sapp, J.3    Essebag, V.4    Novak, P.5    Skanes, A.6    Morillo, C.A.7    Khaykin, Y.8    Birnie, D.9
  • 12
    • 4143058092 scopus 로고    scopus 로고
    • Detection of asymptomatic arrhythmias in unexplained syncope
    • Krahn, A.D., Klein, G.J., Yee, R., Skanes, A.C., Detection of asymptomatic arrhythmias in unexplained syncope. Am Heart J 148 (2004), 326–332.
    • (2004) Am Heart J , vol.148 , pp. 326-332
    • Krahn, A.D.1    Klein, G.J.2    Yee, R.3    Skanes, A.C.4
  • 13
    • 1942487200 scopus 로고    scopus 로고
    • Arrhythmia detection by patient and autoactivation in implantable loop recorders
    • Ng, E., Stafford, P.J., Ng, G.A., Arrhythmia detection by patient and autoactivation in implantable loop recorders. J Interv Card Electrophysiol 10 (2004), 147–152.
    • (2004) J Interv Card Electrophysiol , vol.10 , pp. 147-152
    • Ng, E.1    Stafford, P.J.2    Ng, G.A.3
  • 15
    • 33846889521 scopus 로고    scopus 로고
    • Risk of cellular phone interference with an implantable loop recorder
    • Trigano, A., Blandeau, O., Dale, C., Wong, M.F., Wiart, J., Risk of cellular phone interference with an implantable loop recorder. Int J Cardiol 116 (2007), 126–130.
    • (2007) Int J Cardiol , vol.116 , pp. 126-130
    • Trigano, A.1    Blandeau, O.2    Dale, C.3    Wong, M.F.4    Wiart, J.5
  • 18
    • 50449108320 scopus 로고    scopus 로고
    • Insertable loop recorder R wave sensing performance is improved with dynamic threshold adjustment
    • Cao, J., Lee, B., Abeyratne, A., Gillberg, J.G., Insertable loop recorder R wave sensing performance is improved with dynamic threshold adjustment. Heart Rhythm, 3, 2006, S206.
    • (2006) Heart Rhythm , vol.3 , pp. S206
    • Cao, J.1    Lee, B.2    Abeyratne, A.3    Gillberg, J.G.4
  • 19
    • 79953772902 scopus 로고    scopus 로고
    • Performance of an implantable automatic atrial fibrillation detection device: impact of software adjustments and relevance of manual episode analysis
    • Eitel, C., Husser, D., Hindricks, G., Frühauf, M., Hilbert, S., Arya, A., Gaspar, T., Wetzel, U., Bollmann, A., Piorkowski, C., Performance of an implantable automatic atrial fibrillation detection device: impact of software adjustments and relevance of manual episode analysis. Europace 13 (2011), 480–485.
    • (2011) Europace , vol.13 , pp. 480-485
    • Eitel, C.1    Husser, D.2    Hindricks, G.3    Frühauf, M.4    Hilbert, S.5    Arya, A.6    Gaspar, T.7    Wetzel, U.8    Bollmann, A.9    Piorkowski, C.10
  • 20
    • 84880964400 scopus 로고    scopus 로고
    • Tachycardia detection performance of implantable loop recorders: results from a large “real-life” patient cohort and patients with induced ventricular arrhythmias
    • Volosin, K., Stadler, R.W., Wyszynski, R., Kirchhof, P., Tachycardia detection performance of implantable loop recorders: results from a large “real-life” patient cohort and patients with induced ventricular arrhythmias. Europace 15 (2013), 1215–1222.
    • (2013) Europace , vol.15 , pp. 1215-1222
    • Volosin, K.1    Stadler, R.W.2    Wyszynski, R.3    Kirchhof, P.4
  • 21
    • 84906700706 scopus 로고    scopus 로고
    • P-wave evidence as a method for improving algorithm to detect atrial fibrillation in insertable cardiac monitors
    • Pürerfellner, H., Pokushalov, E., Sarkar, S., Koehler, J., Zhou, R., Urban, L., Hindricks, G., P-wave evidence as a method for improving algorithm to detect atrial fibrillation in insertable cardiac monitors. Heart Rhythm 11 (2014), 1575–1583.
    • (2014) Heart Rhythm , vol.11 , pp. 1575-1583
    • Pürerfellner, H.1    Pokushalov, E.2    Sarkar, S.3    Koehler, J.4    Zhou, R.5    Urban, L.6    Hindricks, G.7
  • 23
    • 84963984133 scopus 로고    scopus 로고
    • Performance of a new AF detection algorithm in a miniaturized insertable cardiac monitor: results from the Reveal LINQ Usability Study
    • Sanders, P., Pürerfellner, H., Pokushalov, E., Sarkar, S., DiBacco, M., Maus, B., Dekker, L.R., Performance of a new AF detection algorithm in a miniaturized insertable cardiac monitor: results from the Reveal LINQ Usability Study. Heart Rhythm 13 (2016), 1425–1430.
    • (2016) Heart Rhythm , vol.13 , pp. 1425-1430
    • Sanders, P.1    Pürerfellner, H.2    Pokushalov, E.3    Sarkar, S.4    DiBacco, M.5    Maus, B.6    Dekker, L.R.7
  • 24
    • 0024205301 scopus 로고
    • Models for longitudinal data: a generalized estimating equation approach
    • Zeger, S.L., Liang, K.Y., Albert, P.S., Models for longitudinal data: a generalized estimating equation approach. Biometrics 44 (1988), 1049–1060.
    • (1988) Biometrics , vol.44 , pp. 1049-1060
    • Zeger, S.L.1    Liang, K.Y.2    Albert, P.S.3
  • 25
    • 84890117399 scopus 로고    scopus 로고
    • Net reclassification indices for evaluating risk-prediction instruments: a critical review
    • Kerr, K.F., Wang, Z., Janes, H., McClelland, R.L., Psaty, B.M., Pepe, M.S., Net reclassification indices for evaluating risk-prediction instruments: a critical review. Epidemiology 25 (2014), 114–121.
    • (2014) Epidemiology , vol.25 , pp. 114-121
    • Kerr, K.F.1    Wang, Z.2    Janes, H.3    McClelland, R.L.4    Psaty, B.M.5    Pepe, M.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.