메뉴 건너뛰기




Volumn 370, Issue 26, 2014, Pages 2478-2486

Cryptogenic stroke and underlying atrial fibrillation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; APPLICATION SITE INFLAMMATION; APPLICATION SITE IRRITATION; APPLICATION SITE PAIN; ARTICLE; CEREBROVASCULAR ACCIDENT; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; DEVICE INFECTION; DIAGNOSTIC TEST ACCURACY STUDY; DISEASE ASSOCIATION; DISEASE DURATION; ELECTROCARDIOGRAPHY MONITORING; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HUMAN; IMPLANTABLE CARDIAC MONITOR; INTENTION TO TREAT ANALYSIS; LONG TERM CARE; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; MIDDLE AGED; OUTCOME ASSESSMENT; PATIENT ASSESSMENT; PATIENT SAFETY; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; AGED; ATRIAL FIBRILLATION; CLINICAL TRIAL; COMPARATIVE STUDY; COMPLICATION; ELECTROCARDIOGRAPHY; MULTICENTER STUDY; PHYSIOLOGIC MONITORING; PROCEDURES; STROKE;

EID: 84903485570     PISSN: 00284793     EISSN: 15334406     Source Type: Journal    
DOI: 10.1056/NEJMoa1313600     Document Type: Article
Times cited : (1654)

References (34)
  • 1
    • 84872091789 scopus 로고    scopus 로고
    • Heart disease and stroke statistics - 2013 update: A report from the American Heart Association
    • Erratum, Circulation 2013;127(23):e841
    • Go AS, Mozaffarian D, Roger VL, et al. Heart disease and stroke statistics - 2013 update: a report from the American Heart Association. Circulation 2013;127(1):e6-e245. [Erratum, Circulation 2013;127(23):e841.]
    • (2013) Circulation , vol.127 , Issue.1
    • Go, A.S.1    Mozaffarian, D.2    Roger, V.L.3
  • 3
    • 0035210949 scopus 로고    scopus 로고
    • Epidemiology of ischemic stroke subtypes according to TOAST criteria: Incidence, recurrence, and long-term survival in ischemic stroke subtypes: A population-based study
    • Kolominsky-Rabas PL, Weber M, Gefeller O, Neundoerfer B, Heuschmann PU. Epidemiology of ischemic stroke subtypes according to TOAST criteria: incidence, recurrence, and long-term survival in ischemic stroke subtypes: a population-based study. Stroke 2001;32:2735-40. (Pubitemid 33134456)
    • (2001) Stroke , vol.32 , Issue.12 , pp. 2735-2740
    • Kolominsky-Rabas, P.L.1    Weber, M.2    Gefeller, O.3    Neundoerfer, B.4    Heuschmann, P.U.5
  • 4
    • 0043124261 scopus 로고    scopus 로고
    • Differences in vascular risk factors between etiological subtypes of ischemic stroke: Importance of population-based studies
    • DOI 10.1161/01.STR.0000079818.08343.8C
    • Schulz UG, Rothwell PM. Differences in vascular risk factors between etiological subtypes of ischemic stroke: importance of population-based studies. Stroke 2003;34:2050-9. (Pubitemid 36944805)
    • (2003) Stroke , vol.34 , Issue.8 , pp. 2050-2059
    • Schulz, U.G.R.1    Rothwell, P.M.2
  • 7
    • 84876231902 scopus 로고    scopus 로고
    • Guidelines for the early management of patients with acute ischemic stroke: A guideline for healthcare professionals from the American Heart Association/American Stroke Association
    • Jauch EC, Saver JL, Adams HP Jr, et al. Guidelines for the early management of patients with acute ischemic stroke: a guideline for healthcare professionals from the American Heart Association/American Stroke Association. Stroke 2013;44:870-947.
    • (2013) Stroke , vol.44 , pp. 870-947
    • Jauch, E.C.1    Saver, J.L.2    Adams Jr., H.P.3
  • 8
    • 84875508668 scopus 로고    scopus 로고
    • 2012 Focused update of the ESC Guidelines for the management of atrial fibrillation: An update of the 2010 ESC Guidelines for the management of atrial fibrillation - Developed with the special contribution of the European Heart Rhythm Association
    • Camm AJ, Lip GY, De Caterina R, et al. 2012 Focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation - developed with the special contribution of the European Heart Rhythm Association. Europace 2012;14:1385-413.
    • (2012) Europace , vol.14 , pp. 1385-1413
    • Camm, A.J.1    Lip, G.Y.2    De Caterina, R.3
  • 9
    • 84862909359 scopus 로고    scopus 로고
    • Subclinical atrial fibrillation and the risk of stroke
    • Healey JS, Connolly SJ, Gold MR, et al. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med 2012;366:120-9.
    • (2012) N Engl J Med , vol.366 , pp. 120-129
    • Healey, J.S.1    Connolly, S.J.2    Gold, M.R.3
  • 10
    • 79961119552 scopus 로고    scopus 로고
    • Prolonged rhythm monitoring for the detection of occult paroxysmal atrial fibrillation in ischemic stroke of unknown cause
    • Seet RC, Friedman PA, Rabinstein AA. Prolonged rhythm monitoring for the detection of occult paroxysmal atrial fibrillation in ischemic stroke of unknown cause. Circulation 2011;124:477-86.
    • (2011) Circulation , vol.124 , pp. 477-486
    • Seet, R.C.1    Friedman, P.A.2    Rabinstein, A.A.3
  • 11
    • 33845203083 scopus 로고    scopus 로고
    • Comparison of continuous versus intermittent monitoring of atrial arrhythmias
    • DOI 10.1016/j.hrthm.2006.07.030, PII S1547527106018418
    • Ziegler PD, Koehler JL, Mehra R. Comparison of continuous versus intermittent monitoring of atrial arrhythmias. Heart Rhythm 2006;3:1445-52. (Pubitemid 44849366)
    • (2006) Heart Rhythm , vol.3 , Issue.12 , pp. 1445-1452
    • Ziegler, P.D.1    Koehler, J.L.2    Mehra, R.3
  • 12
    • 84867395471 scopus 로고    scopus 로고
    • Detection of previously undiagnosed atrial fibrillation in patients with stroke risk factors and usefulness of continuous monitoring in primary stroke prevention
    • Ziegler PD, Glotzer TV, Daoud EG, et al. Detection of previously undiagnosed atrial fibrillation in patients with stroke risk factors and usefulness of continuous monitoring in primary stroke prevention. Am J Cardiol 2012;110:1309-14.
    • (2012) Am J Cardiol , vol.110 , pp. 1309-1314
    • Ziegler, P.D.1    Glotzer, T.V.2    Daoud, E.G.3
  • 13
    • 84866734710 scopus 로고    scopus 로고
    • Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke
    • Rizos T, Güntner J, Jenetzky E, et al. Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke. Stroke 2012;43:2689-94.
    • (2012) Stroke , vol.43 , pp. 2689-2694
    • Rizos, T.1    Güntner, J.2    Jenetzky, E.3
  • 14
    • 39349115930 scopus 로고    scopus 로고
    • Serial electrocardiographic assessments significantly improve detection of atrial fibrillation 2.6-fold in patients with acute stroke
    • DOI 10.1161/STROKEAHA.107.492595, PII 0000767020080200000046
    • Douen AG, Pageau N, Medic S. Serial electrocardiographic assessments significantly improve detection of atrial fibrillation 2.6-fold in patients with acute stroke. Stroke 2008;39:480-2. (Pubitemid 351619476)
    • (2008) Stroke , vol.39 , Issue.2 , pp. 480-482
    • Douen, A.G.1    Pageau, N.2    Medic, S.3
  • 15
    • 70449359754 scopus 로고    scopus 로고
    • Delayed detection of atrial fibrillation after ischemic stroke
    • Kamel H, Lees KR, Lyden PD, et al. Delayed detection of atrial fibrillation after ischemic stroke. J Stroke Cerebrovasc Dis 2009;18:453-7.
    • (2009) J Stroke Cerebrovasc Dis , vol.18 , pp. 453-457
    • Kamel, H.1    Lees, K.R.2    Lyden, P.D.3
  • 16
    • 84895064465 scopus 로고    scopus 로고
    • 96 Hours ECG monitoring for patients with ischemic cryptogenic stroke or transient ischaemic attack
    • Manina G, Agnelli G, Becattini C, Zingarini G, Paciaroni M. 96 Hours ECG monitoring for patients with ischemic cryptogenic stroke or transient ischaemic attack. Intern Emerg Med 2014;9:65-7.
    • (2014) Intern Emerg Med , vol.9 , pp. 65-67
    • Manina, G.1    Agnelli, G.2    Becattini, C.3    Zingarini, G.4    Paciaroni, M.5
  • 17
    • 3042639659 scopus 로고    scopus 로고
    • Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack
    • DOI 10.1161/01.STR.0000131269.69502.d9
    • Jabaudon D, Sztajzel J, Sievert K, Landis T, Sztajzel R. Usefulness of ambulatory 7-day ECG monitoring for the detection of atrial fibrillation and flutter after acute stroke and transient ischemic attack. Stroke 2004;35:1647-51. (Pubitemid 38823640)
    • (2004) Stroke , vol.35 , Issue.7 , pp. 1647-1651
    • Jabaudon, D.1    Sztajzel, J.2    Sievert, K.3    Landis, T.4    Sztajzel, R.5
  • 18
    • 84884480310 scopus 로고    scopus 로고
    • Noninvasive cardiac event monitoring to detect atrial fibrillation after ischemic stroke: A randomized, controlled trial
    • Higgins P, MacFarlane PW, Dawson J, McInnes GT, Langhorne P, Lees KR. Noninvasive cardiac event monitoring to detect atrial fibrillation after ischemic stroke: a randomized, controlled trial. Stroke 2013;44:2525-31.
    • (2013) Stroke , vol.44 , pp. 2525-2531
    • Higgins, P.1    MacFarlane, P.W.2    Dawson, J.3    McInnes, G.T.4    Langhorne, P.5    Lees, K.R.6
  • 20
    • 77952990457 scopus 로고    scopus 로고
    • Detection of paroxysmal atrial fibrillation with transtelephonic EKG in TIA or stroke patients
    • Gaillard N, Deltour S, Vilotijevic B, et al. Detection of paroxysmal atrial fibrillation with transtelephonic EKG in TIA or stroke patients. Neurology 2010;74:1666-70.
    • (2010) Neurology , vol.74 , pp. 1666-1670
    • Gaillard, N.1    Deltour, S.2    Vilotijevic, B.3
  • 21
    • 84860202393 scopus 로고    scopus 로고
    • Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening?
    • Roten L, Schilling M, Häberlin A, et al. Is 7-day event triggered ECG recording equivalent to 7-day Holter ECG recording for atrial fibrillation screening? Heart 2012;98:645-9.
    • (2012) Heart , vol.98 , pp. 645-649
    • Roten, L.1    Schilling, M.2    Häberlin, A.3
  • 22
    • 65449189576 scopus 로고    scopus 로고
    • Intermittent atrial fibrillation may account for a large proportion of otherwise cryptogenic stroke: A study of 30-day cardiac event monitors
    • Elijovich L, Josephson SA, Fung GL, Smith WS. Intermittent atrial fibrillation may account for a large proportion of otherwise cryptogenic stroke: a study of 30-day cardiac event monitors. J Stroke Cerebrovasc Dis 2009;18:185-9.
    • (2009) J Stroke Cerebrovasc Dis , vol.18 , pp. 185-189
    • Elijovich, L.1    Josephson, S.A.2    Fung, G.L.3    Smith, W.S.4
  • 23
    • 79955062310 scopus 로고    scopus 로고
    • Predictors of occult paroxysmal atrial fibrillation in cryptogenic strokes detected by long-term non-invasive cardiac monitoring
    • Bhatt A, Majid A, Razak A, Kassab M, Hussain S, Safdar A. Predictors of occult paroxysmal atrial fibrillation in cryptogenic strokes detected by long-term non-invasive cardiac monitoring. Stroke Res Treat 2011;2011:172074.
    • (2011) Stroke Res Treat , vol.2011 , pp. 172074
    • Bhatt, A.1    Majid, A.2    Razak, A.3    Kassab, M.4    Hussain, S.5    Safdar, A.6
  • 24
    • 84866729849 scopus 로고    scopus 로고
    • Detection of paroxysmal atrial fibrillation by 30-day event monitoring in cryptogenic ischemic stroke: The Stroke and Monitoring for PAF in Real Time (SMART) Registry
    • Flint AC, Banki NM, Ren X, Rao VA, Go AS. Detection of paroxysmal atrial fibrillation by 30-day event monitoring in cryptogenic ischemic stroke: the Stroke and Monitoring for PAF in Real Time (SMART) Registry. Stroke 2012;43:2788-90.
    • (2012) Stroke , vol.43 , pp. 2788-2790
    • Flint, A.C.1    Banki, N.M.2    Ren, X.3    Rao, V.A.4    Go, A.S.5
  • 25
    • 84872957222 scopus 로고    scopus 로고
    • Pilot randomized trial of outpatient cardiac monitoring after cryptogenic stroke
    • Kamel H, Navi BB, Elijovich L, et al. Pilot randomized trial of outpatient cardiac monitoring after cryptogenic stroke. Stroke 2013;44:528-30.
    • (2013) Stroke , vol.44 , pp. 528-530
    • Kamel, H.1    Navi, B.B.2    Elijovich, L.3
  • 26
    • 84870926360 scopus 로고    scopus 로고
    • Outpatient cardiac telemetry detects a high rate of atrial fibrillation in cryptogenic stroke
    • Miller DJ, Khan MA, Schultz LR, et al. Outpatient cardiac telemetry detects a high rate of atrial fibrillation in cryptogenic stroke. J Neurol Sci 2013;324:57-61.
    • (2013) J Neurol Sci , vol.324 , pp. 57-61
    • Miller, D.J.1    Khan, M.A.2    Schultz, L.R.3
  • 27
    • 58149269939 scopus 로고    scopus 로고
    • Atrial fibrillation detected by mobile cardiac outpatient telemetry in cryptogenic TIA or stroke
    • Tayal AH, Tian M, Kelly KM, et al. Atrial fibrillation detected by mobile cardiac outpatient telemetry in cryptogenic TIA or stroke. Neurology 2008;71:1696-701.
    • (2008) Neurology , vol.71 , pp. 1696-1701
    • Tayal, A.H.1    Tian, M.2    Kelly, K.M.3
  • 28
    • 84888993497 scopus 로고    scopus 로고
    • Paroxysmal atrial fibrillation in cryptogenic stroke: A case-control study
    • Rabinstein AA, Fugate JE, Mandrekar J, et al. Paroxysmal atrial fibrillation in cryptogenic stroke: a case-control study. J Stroke Cerebrovasc Dis 2013;22:1405-11.
    • (2013) J Stroke Cerebrovasc Dis , vol.22 , pp. 1405-1411
    • Rabinstein, A.A.1    Fugate, J.E.2    Mandrekar, J.3
  • 29
    • 84878947462 scopus 로고    scopus 로고
    • Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke
    • Cotter PE, Martin PJ, Ring L, Warburton EA, Belham M, Pugh PJ. Incidence of atrial fibrillation detected by implantable loop recorders in unexplained stroke. Neurology 2013;80:1546-50.
    • (2013) Neurology , vol.80 , pp. 1546-1550
    • Cotter, P.E.1    Martin, P.J.2    Ring, L.3    Warburton, E.A.4    Belham, M.5    Pugh, P.J.6
  • 30
    • 79952030675 scopus 로고    scopus 로고
    • Unexpected low prevalence of atrial fibrillation in cryptogenic ischemic stroke: A prospective study
    • Dion F, Saudeau D, Bonnaud I, et al. Unexpected low prevalence of atrial fibrillation in cryptogenic ischemic stroke: a prospective study. J Interv Card Electrophysiol 2010;28:101-7.
    • (2010) J Interv Card Electrophysiol , vol.28 , pp. 101-107
    • Dion, F.1    Saudeau, D.2    Bonnaud, I.3
  • 31
    • 84879923293 scopus 로고    scopus 로고
    • Insertable cardiac event recorder in detection of atrial fibrillation after cryptogenic stroke: An audit report
    • Etgen T, Hochreiter M, Mundel M, Freudenberger T. Insertable cardiac event recorder in detection of atrial fibrillation after cryptogenic stroke: an audit report. Stroke 2013;44:2007-9.
    • (2013) Stroke , vol.44 , pp. 2007-2009
    • Etgen, T.1    Hochreiter, M.2    Mundel, M.3    Freudenberger, T.4
  • 32
    • 84893670659 scopus 로고    scopus 로고
    • Detection of atrial fibrillation after ischemic stroke or transient ischemic attack: A systematic review and meta-analysis
    • Kishore A, Vail A, Majid A, et al. Detection of atrial fibrillation after ischemic stroke or transient ischemic attack: a systematic review and meta-analysis. Stroke 2014;45:520-6.
    • (2014) Stroke , vol.45 , pp. 520-526
    • Kishore, A.1    Vail, A.2    Majid, A.3
  • 33
    • 77955694207 scopus 로고    scopus 로고
    • Cryptogenic Stroke and underlying Atrial Fibrillation (CRYSTAL AF): Design and rationale
    • Sinha AM, Diener HC, Morillo CA, et al. Cryptogenic Stroke and underlying Atrial Fibrillation (CRYSTAL AF): design and rationale. Am Heart J 2010;160(1):36.e1-41.e1.
    • (2010) Am Heart J , vol.160 , Issue.1
    • Sinha, A.M.1    Diener, H.C.2    Morillo, C.A.3
  • 34
    • 77951896083 scopus 로고    scopus 로고
    • Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial
    • Hindricks G, Pokushalov E, Urban L, et al. Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: results of the XPECT trial. Circ Arrhythm Electrophysiol 2010;3:141-7.
    • (2010) Circ Arrhythm Electrophysiol , vol.3 , pp. 141-147
    • Hindricks, G.1    Pokushalov, E.2    Urban, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.