메뉴 건너뛰기




Volumn 15, Issue 8, 2013, Pages 1215-1222

Tachycardia detection performance of implantable loop recorders: Results from a large 'real-life' patient cohort and patients with induced ventricular arrhythmias

Author keywords

Algorithms; Arrhythmia detection; ECG monitoring; Implantable loop recorder; Ventricular fibrillation; Ventricular tachycardia

Indexed keywords

ARTICLE; COMPUTER PROGRAM; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; IMPLANTABLE CARDIAC MONITOR; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; SKIN ELECTRODE; SUPRAVENTRICULAR TACHYCARDIA;

EID: 84880964400     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eut036     Document Type: Article
Times cited : (21)

References (16)
  • 1
  • 4
    • 0141570962 scopus 로고    scopus 로고
    • Comparison of automatic and patient-Activated arrhythmia recordings by implantable loop recorders in the evaluation of syncope
    • Ermis C, Zhu AX, Pham S, Li JM, Guerrero M, Vrudney A et al. Comparison of automatic and patient-Activated arrhythmia recordings by implantable loop recorders in the evaluation of syncope. Am J Cardiol 2003;92:815-9
    • (2003) Am J Cardiol , vol.92 , pp. 815-819
    • Ermis, C.1    Zhu, A.X.2    Pham, S.3    Li, J.M.4    Guerrero, M.5    Vrudney, A.6
  • 5
    • 0037247790 scopus 로고    scopus 로고
    • Cardiac arrhythmias and risk stratification after myocardial infarction: Results of the CARISMA pilot study
    • Huikuri HV, Mahaux V, Bloch-Thomsen PE. Cardiac arrhythmias and risk stratification after myocardial infarction: Results of the CARISMA pilot study. Pacing Clin Electrophysiol 2003;26:416-9
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 416-419
    • Huikuri, H.V.1    Mahaux, V.2    Bloch-Thomsen, P.E.3
  • 6
    • 4143058092 scopus 로고    scopus 로고
    • Detection of asymptomatic arrhythmias in unexplained syncope
    • Krahn AD, Klein GJ, Yee R, Skanes AC. Detection of asymptomatic arrhythmias in unexplained syncope. Am Heart J 2004;148:326-32
    • (2004) Am Heart J , vol.148 , pp. 326-332
    • Krahn, A.D.1    Klein, G.J.2    Yee, R.3    Skanes, A.C.4
  • 7
    • 1942487200 scopus 로고    scopus 로고
    • Arrhythmia detection by patient and autoactivation in implantable loop recorders
    • Ng E, Stafford PJ, Ng GA. Arrhythmia detection by patient and autoactivation in implantable loop recorders. J Interv Card Electrophysiol 2004;10:147-52
    • (2004) J Interv Card Electrophysiol , vol.10 , pp. 147-152
    • Ng, E.1    Stafford, P.J.2    Ng, G.A.3
  • 9
    • 33750975388 scopus 로고    scopus 로고
    • Digital implantable loop recorders in the investigation of syncope in children: Benefits and limitations
    • Kothari DS, Riddell F, Smith W, Voss J, Skinner Jr. Digital implantable loop recorders in the investigation of syncope in children: Benefits and limitations. Heart Rhythm 2006;3:1306-12
    • (2006) Heart Rhythm , vol.3 , pp. 1306-1312
    • Kothari, D.S.1    Riddell, F.2    Smith, W.3    Voss, J.4    Skinner, J.R.5
  • 12
    • 0035936534 scopus 로고    scopus 로고
    • Critical analysis of dual-chamber implantable cardioverter-defibrillator arrhythmia detection: Results and technical considerations
    • Wilkoff BL, Kühlkamp V, Volosin K, Ellenbogen K, Waldecker B, Kacet S et al. Critical analysis of dual-chamber implantable cardioverter- defibrillator arrhythmia detection: Results and technical considerations. Circulation 2001;103:381-6
    • (2001) Circulation , vol.103 , pp. 381-386
    • Wilkoff, B.L.1    Kühlkamp, V.2    Volosin, K.3    Ellenbogen, K.4    Waldecker, B.5    Kacet, S.6
  • 13
    • 79953772902 scopus 로고    scopus 로고
    • Performance of an implantable automatic atrial fibrillation detection device: Impact of software adjustments and relevance of manual episode analysis
    • Eitel C, Husser D, Hindricks G, Frühauf M, Hilbert S, Arya A et al. Performance of an implantable automatic atrial fibrillation detection device: Impact of software adjustments and relevance of manual episode analysis. Europace 2011;13:480-5
    • (2011) Europace , vol.13 , pp. 480-485
    • Eitel, C.1    Husser, D.2    Hindricks, G.3    Frühauf, M.4    Hilbert, S.5    Arya, A.6
  • 14
    • 79952161004 scopus 로고    scopus 로고
    • Effectiveness of remote monitoring in the management of syncope and palpitations
    • Furukawa T, Maggi R, Bertolone C, Ammirati F, Santini M, Ricci R et al. Effectiveness of remote monitoring in the management of syncope and palpitations. Europace 2011;13:431-7
    • (2011) Europace , vol.13 , pp. 431-437
    • Furukawa, T.1    Maggi, R.2    Bertolone, C.3    Ammirati, F.4    Santini, M.5    Ricci, R.6
  • 15
    • 33745685677 scopus 로고    scopus 로고
    • A comparison of EMpiric to Physician-Tailored Programming of Implantable Cardioverter-defibrillators: Results from the prospective randomized multicenter EMPIRIC trial
    • for the EMPIRIC Trial Investigators
    • Wilkoff BL, Ousdigian KT, Sterns LD, Wang ZJ, Wilson RD, Morgan JM, for the EMPIRIC Trial Investigators. A comparison of EMpiric to Physician-Tailored Programming of Implantable Cardioverter-defibrillators: Results from the prospective randomized multicenter EMPIRIC trial. J Am Coll Cardiol 2006;48:330-9
    • (2006) J Am Coll Cardiol , vol.48 , pp. 330-339
    • Wilkoff, B.L.1    Ousdigian, K.T.2    Sterns, L.D.3    Wang, Z.J.4    Wilson, R.D.5    Morgan, J.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.